Comark C9550 Pressure Meter
Comark C9550 Pressure Meter
Comark
C9550 & C9500
Series
Pressure
Meters
Comark™
Kane-May™
C9550 C9550
plant, such as diggers, tractors • Readings from the transducers are Transducer
Diaphragm
Transducer
C9550 Transducers
Comark pressure transducers for the C9550
are sourced from the highly respected
German manufacturer IMT Industrie-
Messtechnik, originally part of VDO.
Transducers are available to measure
gauge or absolute pressure, with a choice
of measurement range, accuracy and
diaphragm type.
All feature stainless steel construction for high
resistance to corrosive fluids and acceptability
for food industry use. The non-process side is
proof against ingress to IP65.
Each transducer features an intelligent sensor,
which communicates with the C9550,
enabling it to recognise the transducer range
and available scales.
C9500 INTERNAL SENSOR
The following gauge pressure transducers
with internal diaphragm sensors are available PRESSURE METERS
from stock:-
The Comark C9500 internal sensor
models complement the C9550 and
PG 205-1 0 to 2.5 bar feature microprocessor control for
PG 6-1 0 to 6 Bar flexibility, performance and ease of use.
PG 10-1 0 to 10 Bar
Internal sensor pressure meters are ideal
PG 100-1 0 to 100 Bar
for heating, ventilation, air conditioning, • Intrinsically Safe versions to BASEEFA
PG 400-1 0 to 400 Bar
and petrochemical industries, plus EEx ia IIC T4 available
general service and maintenance
Full details of all Comark transducers are given • All generally used pressure scales
applications.
in a separate datasheet , order code C089. available, with selected scale held
In addition they can be used to check the in memory
C9550 Accessories calibration of pressure installations and a
• Carefully selected measurement range
special test kit is available for this.
ADP22 Interface Lead. 1.5m lead to connect on each model to optimise the
C9550 to any Comark transducer. Standard (non-IS) models can be available resolution in each scale
supplied as special versions with silicone
ADP23 Adaptor. Used to connect the G1/2 A • Hold function with held readings,
protection to allow liquid pressure
( 1/2” BSP) male thread of the transducer to a including maximum and minimum,
measurement without sensor corrosion.
G1/4 A ( 1/4” BSP) thread fitting. displayed in any scale
G1/2 -W. Washer type gasket for pressure All C9500 internal sensor instruments are
• Adjustable zero value to compensate
tight connections between a transducer and supplied with 1/8 ” BSP pneumatic
for ambient temperature variations,
its location or an ADP23 adaptor. connectors and Intrinsically Safe versions
with value held in memory
are supplied with a robust carrying case.
G1/4 -W. Washer type gasket for pressure • Averaged reading function filters
tight connections between ADP23 adaptor C9500 Internal Sensor
out transient readings to give a more
and the transducer location. Pressure Meter Benefits
stable displayed reading
G1/2 -OW. Washer type gasket with a built-in • Tough, practical, stylish cases, dust
• Maximum pressure for each
“O” ring. For pressure tight seals where a and waterproof to IP67, BS EN 60529
instrument can be displayed with over-
transducer is moved from one location to and IEC 529 and able to handle the
range indication for additional safety
another to measure different applications. toughest assignments
• Selectable auto switch off
LC95. Carrying case for C9550 to take 1 x • Twin inputs to measure differential or
instrument, 1 x transducer, ADP22 Interface positive/negative (vacuum) gauge • TK2 test kit for pressure calibration
Lead, ADP23 adaptor and operator manuals. pressures available
C9550 TECHNICAL SPECIFICATION C9500 SERIES PRESSURE METERS
Calibrated Accuracy ±0.06% of reading ± 1 digit
AND ACCESSORIES
at +23 °C ORDER CODE DESCRIPTION
Temperature Coefficient <0.01% of reading per ˚C C9550 Pressure meter for external
of Reading change from +23˚C transducers, with operator
manual and transducer range
Response Time 4 readings per second datasheet
EMC Tested to EN61326-1 Light Industrial KMP15 Binder connector - for in-line
Criteria A performance measurements with
internal sensor models
Tested to EN61326-1 Heavy Industrial
Criteria B performance TCP1 Tyre connector for use with
internal sensor models
TK2 Pressure test kit with tubing,
hand pump, scale conversion
chart and carrying case
C9500 INTERNAL SENSOR MODELS
TECHNICAL SPECIFICATIONS WARRANTY
All Comark instruments have a minimum one year warranty unless
SCALE Standard C9551 C9553 C9555 C9557
otherwise stated. The warranty period for temperature probes is for six
Intrinsically Safe C9501/IS C9503/IS C9505/IS C9507/IS months and all other probes and electrodes are unwarranted because
For Liquids† C9551/SIL C9553/SIL C9555/SIL C9557/SIL the conditions of use are beyond our control.
PSI Range 0 to ± 2 0 to ± 5 0 to ± 30 0 to ± 100
The Comark warranty covers manufacturing defects and component
Resolution 0.001 0.001 0.01 0.1
failure and applies worldwide. The warranty does not affect your
mbar Range 0 to ± 140 0 to ± 350 0 to ± 2000 0 to ± 6900 statutory rights.
Resolution 0.1 0.1 1 1
In line with our policy of continuous development we reserve the right
inH2O Range 0 to ± 55 0 to ± 140 0 to ± 830 0 to ± 2750 to alter any product specifications without notice.
Resolution 0.01 0.1 0.1 1
Comark Limited has an accredited UKAS calibration laboratory for
inHg Range 0 to ± 4 0 to ± 9.999 0 to ± 61 0 to ± 200 temperature measurement. UKAS certificates can be provided for any
Resolution 0.001 0.001 0.01 0.1
Comark, Kane-May or other temperature measurement instrument.
mmHg Range 0 to ± 99.99 0 to ± 260 0 to ± 1500 0 to ± 5200
Resolution 0.01 0.1 1 1
Torr Range 0 to ± 99.99 0 to ± 260 0 to ± 1500 0 to ± 5200
Resolution 0.01 0.1 1 1
Pa Range 0 to ± 9999 - - -
Resolution 1 - - -
KPa Range - 0 to ± 35 0 to ± 200 0 to ± 690
Resolution - 0.01 0.1 0.1
mmH2O Range 0 to ± 1400 0 to ± 3500 - -
Resolution 1 1 - -
Distributed by:
cmH2O Range - - 0 to ± 2100 0 to ± 7000
Resolution - - 1 1
Kgcm-2 Range - - 0 to ±2.1 0 to ±7.0
Resolution - - 0.001 0.001
Maximum Over/ 6 PSI/ 15 PSI/ 90 PSI/ 200PSI/
Under Pressure 400mbar 1000mbar 6200mbar 13700mbar
Accuracy at +23˚C ± 0.2% of full scale
Repeatability at +23˚C ± 0.1% of full scale
Mean Temperature
Coefficient of Reading Better than 0.1% per ˚C
J32007
Operating Range
Temperature 0 to +50˚C
Humidity 10 to 90% RH non condensing
C090/2/EN © Comark Limited