COMARK

Comark
C9550 & C9500
Series
Pressure
Meters

Comark™
Kane-May™
C9550 C9550

Typical applications for the C9550 are wide and


varied, ranging from industrial presses to outdoor
process plant.
• Extremely versatile data capability:-
maximum and minimum pressures
are stored in memory for display at
any time
maximum and minimum readings
can be reset to the current reading
as needed
hold function freezes the display;
useful when later records of readings
are needed
held readings can be displayed in any
available scale
previous maximum and minimum
readings can be displayed in
C9550 Pressure Meter Benefits hold mode
• Display decimal point automatically adjusts
• Designed for use with external pressure when scales are changed to give optimum
transducers, C9550 offers safe, accurate resolution
pressure measurement from 0 to 4000 bar
• Accuracy enhanced by two key features:-
• Choice of gauge or absolute pressure
adjustable zero value compensates for
measurement
ambient temperature fluctuations or
• “Hot Swap” function enables the instrument tares non-zero pressure readings
to communicate with and automatically
averaged reading function, selectable
Introduction recognise and adjust to, the transducer
to filter out transient readings
range and available scales
THE COMARK C9550 - • Selectable auto switch off saves battery
• No range adjustments are needed and one
latest model in the C9500 life, with scale and switch off settings
instrument covers every transducer in the
pressure range and sharing retained in memory
whole 0 to 4,000 bar range
the same robust case , dust
and waterproof to IP67 • Battery powered C9550 also powers all
standards. Comark transducers, no separate
transducer power needed
Measuring from external pressure
transducers the C9550 is ideal for • The multiscale C9550 displays pressure
many applications including:- measurements in a choice of 12 scales
(subject to transducer range) to suit
maintenance of plastic injection
every need, with the selected scale held
machines, hydraulic presses
in memory
and other machinery, mobile Front Flush
Diaphragm
Internal

plant, such as diggers, tractors • Readings from the transducers are Transducer
Diaphragm
Transducer

and earthmovers displayed on the large, clear LCD display


and the required scale can be selected at
production engineering the touch of a button
production and processing of • No pressure reaches the C9550 itself, so
food, pharmaceuticals, there can be no possibility of damage to the
chemicals and petrochemicals instrument. Transducers and pressure
installations are also protected, as any over
heating and refrigeration
range pressures are displayed as an
gas production and distribution effective warning
C9500 C9500

C9550 Transducers
Comark pressure transducers for the C9550
are sourced from the highly respected
German manufacturer IMT Industrie-
Messtechnik, originally part of VDO.
Transducers are available to measure
gauge or absolute pressure, with a choice
of measurement range, accuracy and
diaphragm type.
All feature stainless steel construction for high
resistance to corrosive fluids and acceptability
for food industry use. The non-process side is
proof against ingress to IP65.
Each transducer features an intelligent sensor,
which communicates with the C9550,
enabling it to recognise the transducer range
and available scales.
C9500 INTERNAL SENSOR
The following gauge pressure transducers
with internal diaphragm sensors are available PRESSURE METERS
from stock:-
The Comark C9500 internal sensor
models complement the C9550 and
PG 205-1 0 to 2.5 bar feature microprocessor control for
PG 6-1 0 to 6 Bar flexibility, performance and ease of use.
PG 10-1 0 to 10 Bar
Internal sensor pressure meters are ideal
PG 100-1 0 to 100 Bar
for heating, ventilation, air conditioning, • Intrinsically Safe versions to BASEEFA
PG 400-1 0 to 400 Bar
and petrochemical industries, plus EEx ia IIC T4 available
general service and maintenance
Full details of all Comark transducers are given • All generally used pressure scales
applications.
in a separate datasheet , order code C089. available, with selected scale held
In addition they can be used to check the in memory
C9550 Accessories calibration of pressure installations and a
• Carefully selected measurement range
special test kit is available for this.
ADP22 Interface Lead. 1.5m lead to connect on each model to optimise the
C9550 to any Comark transducer. Standard (non-IS) models can be available resolution in each scale
supplied as special versions with silicone
ADP23 Adaptor. Used to connect the G1/2 A • Hold function with held readings,
protection to allow liquid pressure
( 1/2” BSP) male thread of the transducer to a including maximum and minimum,
measurement without sensor corrosion.
G1/4 A ( 1/4” BSP) thread fitting. displayed in any scale
G1/2 -W. Washer type gasket for pressure All C9500 internal sensor instruments are
• Adjustable zero value to compensate
tight connections between a transducer and supplied with 1/8 ” BSP pneumatic
for ambient temperature variations,
its location or an ADP23 adaptor. connectors and Intrinsically Safe versions
with value held in memory
are supplied with a robust carrying case.
G1/4 -W. Washer type gasket for pressure • Averaged reading function filters
tight connections between ADP23 adaptor C9500 Internal Sensor
out transient readings to give a more
and the transducer location. Pressure Meter Benefits
stable displayed reading
G1/2 -OW. Washer type gasket with a built-in • Tough, practical, stylish cases, dust
• Maximum pressure for each
“O” ring. For pressure tight seals where a and waterproof to IP67, BS EN 60529
instrument can be displayed with over-
transducer is moved from one location to and IEC 529 and able to handle the
range indication for additional safety
another to measure different applications. toughest assignments
• Selectable auto switch off
LC95. Carrying case for C9550 to take 1 x • Twin inputs to measure differential or
instrument, 1 x transducer, ADP22 Interface positive/negative (vacuum) gauge • TK2 test kit for pressure calibration
Lead, ADP23 adaptor and operator manuals. pressures available
C9550 TECHNICAL SPECIFICATION C9500 SERIES PRESSURE METERS
Calibrated Accuracy ±0.06% of reading ± 1 digit
AND ACCESSORIES
at +23 °C ORDER CODE DESCRIPTION
Temperature Coefficient <0.01% of reading per ˚C C9550 Pressure meter for external
of Reading change from +23˚C transducers, with operator
manual and transducer range
Response Time 4 readings per second datasheet

Operating Range -20 to +50˚C CRS/1 Protective rubber boot for


all C9500 pressure meters
Environmental Rating IP67
ADP22 1.5m interface lead for C9550
Power Source 9V PP3 6F22 - MN1604 UCAR9V
ADP23 Adaptor for C9550 transducers,
Battery Life 140 hours (using MN1604) G1/2 A ( 1/2"BSP) to G1/4 A ( 1/4"BSP)
threads
Disconnected Transducer
Indication -00- G1/2-W G1/2 A ( 1/2"BSP) washer type gasket
for C9550 transducers
Over Pressure
Indication -02- G1/4-W G1/4 A ( 1/4"BSP) washer type gasket
for ADP23 adaptor
Over 9999 Reading Indication Lowest 4 digits blink
G1/2-OW G1/2 A ( 1/2"BSP) washer type gasket
Connections 8 way Lumberg socket KFV81 with a built-in “O” ring, for repeated
Mating plug, Lumberg SV81 connection of C9550 transducers to
Dimensions different points
Height 173mm LC95 Carrying case for C9550
Width 70/83mm to take 1 x instrument,
1 x transducer, ADP22 interface
Depth 32mm lead, ADP23 adaptor and
Weight 255 gms including battery operator manuals

EMC Tested to EN61326-1 Light Industrial KMP15 Binder connector - for in-line
Criteria A performance measurements with
internal sensor models
Tested to EN61326-1 Heavy Industrial
Criteria B performance TCP1 Tyre connector for use with
internal sensor models
TK2 Pressure test kit with tubing,
hand pump, scale conversion
chart and carrying case
C9500 INTERNAL SENSOR MODELS
TECHNICAL SPECIFICATIONS WARRANTY
All Comark instruments have a minimum one year warranty unless
SCALE Standard C9551 C9553 C9555 C9557
otherwise stated. The warranty period for temperature probes is for six
Intrinsically Safe C9501/IS C9503/IS C9505/IS C9507/IS months and all other probes and electrodes are unwarranted because
For Liquids† C9551/SIL C9553/SIL C9555/SIL C9557/SIL the conditions of use are beyond our control.
PSI Range 0 to ± 2 0 to ± 5 0 to ± 30 0 to ± 100
The Comark warranty covers manufacturing defects and component
Resolution 0.001 0.001 0.01 0.1
failure and applies worldwide. The warranty does not affect your
mbar Range 0 to ± 140 0 to ± 350 0 to ± 2000 0 to ± 6900 statutory rights.
Resolution 0.1 0.1 1 1
In line with our policy of continuous development we reserve the right
inH2O Range 0 to ± 55 0 to ± 140 0 to ± 830 0 to ± 2750 to alter any product specifications without notice.
Resolution 0.01 0.1 0.1 1
Comark Limited has an accredited UKAS calibration laboratory for
inHg Range 0 to ± 4 0 to ± 9.999 0 to ± 61 0 to ± 200 temperature measurement. UKAS certificates can be provided for any
Resolution 0.001 0.001 0.01 0.1
Comark, Kane-May or other temperature measurement instrument.
mmHg Range 0 to ± 99.99 0 to ± 260 0 to ± 1500 0 to ± 5200
Resolution 0.01 0.1 1 1
Torr Range 0 to ± 99.99 0 to ± 260 0 to ± 1500 0 to ± 5200
Resolution 0.01 0.1 1 1
Pa Range 0 to ± 9999 - - -
Resolution 1 - - -
KPa Range - 0 to ± 35 0 to ± 200 0 to ± 690
Resolution - 0.01 0.1 0.1
mmH2O Range 0 to ± 1400 0 to ± 3500 - -
Resolution 1 1 - -
Distributed by:
cmH2O Range - - 0 to ± 2100 0 to ± 7000
Resolution - - 1 1
Kgcm-2 Range - - 0 to ±2.1 0 to ±7.0
Resolution - - 0.001 0.001
Maximum Over/ 6 PSI/ 15 PSI/ 90 PSI/ 200PSI/
Under Pressure 400mbar 1000mbar 6200mbar 13700mbar
Accuracy at +23˚C ± 0.2% of full scale
Repeatability at +23˚C ± 0.1% of full scale
Mean Temperature
Coefficient of Reading Better than 0.1% per ˚C
J32007

Operating Range
Temperature 0 to +50˚C
Humidity 10 to 90% RH non condensing
C090/2/EN © Comark Limited

Environmental Rating IP67, BS EN 60529, IEC 529


Protection Levels
(IS Models only) EEx ia IIC T4 BASEEFA Certificate Ex 95C2454*
1 8"
Connections / BSP female Comark Limited Gunnels Wood Road, Stevenage, Hertfordshire SG1 2TA England
Battery 9V PP3 6F22 - MN1604 UCAR9V Tel: 01438 (+44 1438) 367367 Fax: 01438 (+44 1438) 367400
Email enquiries UK and Ireland: [email protected]
Battery Life 90 hours (MN1604) Email enquiries International: [email protected]
Comark Instruments Inc. 9710 SW Sunshine Court, Beaverton, OR 97005, USA.
Tel: (503) 643 5204 Fax: (503) 644 5859 Email: [email protected]
† Any standard model can be ordered with silicone protection for use with liquids. Add /SIL to order code.
* Certification applicable at atmospheric pressure. Website: www.comarkltd.com a VIDA GROUP company