Glomax Discover and Explorer: State-Of-The-Art Multimode Readers For Luminescence, Fluorescence and Absorbance Detection
Glomax Discover and Explorer: State-Of-The-Art Multimode Readers For Luminescence, Fluorescence and Absorbance Detection
and Explorer
State-of-the-art multimode readers
for luminescence, fluorescence and
absorbance detection.
Easy-To-Use Integrated Assays Flexible
The intuitive touchscreen display, Optimized, preloaded Promega Select the detection modules you
preloaded protocols and automatic protocols are part of the GloMax® need. Place on a bench top or
instrument gain adjustments make Systems Software, minimizing time integrate into a larger automated
it simple to produce your data and spent optimizing instrument settings. platform for higher throughput.
analyze results.
OVERVIEW
VIDEO
Purchase the instrument and modules you need now. Upgrade your
system later as your laboratory needs change.
GloMax® Explorer
Model GM3500 ✔ ✔ ✔ Upgrade Upgrade
GloMax® Discover
Model GM3000 ✔ ✔ ✔ ✔
Unpack, Plug In and
Start Generating Data
Automatic Instrument
Adjustments
No manual gain adjustment for luminescence reads.
Optimized settings are set automatically.
Reporting
Preloaded software provides many of the required
technical elements of a part 11 compliant system
when used with the appropriate laboratory workflow.
Data Analysis
Easily measure and analyze your results using the
intuitive, preloaded SMART Protocols software.
Easy to Use for Your
Application
Automatic Filter Slides
• Multiple reads without user intervention
• Easily perform BRET and FRET studies
• Customize filters for your needs
Flexible Interface
• Select a preloaded protocol or customize your own
Integrated Filter Slides
• Set up a plate map
• View data in a heat map display
• Easily export your results to a variety of locations
Cytotoxicity 125
Percent Vehicle Control (Viability)
Percent Activity
1,500 HER4
100 75 IGF1R
Viability InsR
1,000
(CellTiter-Glo®) 50
KDR
50
500 PDGFRα
25
PDGFRβ
0 0 0
12143MA
–4 –3 –2 –1 0 1 2 3 4
11976MA
Multiplexed cytotoxicity and viability assays performed on digitonin- Receptor tyrosine kinase inhibition was assessed following incubation with
treated K562 cells. gefitinib, a selective inhibitor of EGFR, using the ADP-GloTM Kinase Assay.
State-of-the-Art Sensitivity
1 x 107 14
Luminescence (RLU)
12
8 x 106
10
mBRET Ratio
6 x 106
8
4 x 106 IC50 = 1.9µM
6
2 x 106 4
0 2
–11 –10 –9 –8 –7 –6 –5
0
11936MA
12753MB
Log[Control Ab, Anti-CD20], g/ml
Nutlin-3 (µM)
ADCC Bioassay Target cells were incubated with a series of concentrations of A dose-response curve showing the disruption of the p53 and MDM2
Control Ab, Anti-CD20, followed by addition of ADCC Bioassay Effector Cells. interaction using the inhibitor Nutlin-3 in a NanoBRET™ assay.
Flexible
Workflow
Use on a bench top or integrate into
your automated workflow for higher
throughput and walk-away operation.
Automation Ready
Controlable by third-party scheduling
software with liquid handling and plate
stackers. The software is SiLA compat-
ible, making integration device control
simple as standards evolve.
Luminescence
• Low-noise PMT ensures collected light is not compromised
• 10 to 1,000 times more sensitive than competitor instruments
• No need to dilute samples or manage gain settings
• 2 to 3 logs more usable data than competing instruments
• Filtered luminescence readout for BRET or multi-wavelength distinction (for GloMax® Discover only)
or total luminescence
• Lower cross talk for more usable data
• Five filters included for BRET and filtered luminescence assays such as NanoBRET™, Renilla/YFP BRET
and Chroma-Glo™ (for GloMax® Discover only)
• Or, customize all 5 luminescence filters to your needs (for GloMax® Discover only)
Fluorescence
• Uses powerful wavelength-matched, light-emitting diodes (LED) as excitation sources
• LEDs closely match excitation profiles of commonly used fluorescent molecules to ensure high sensitivity
• Reduces nonspecific light leakage, a common problem when using broad-spectrum light sources
• Five excitation and emission filters included for common fluorescence assays; plus 1 customizable excitation and
emission position
• Or, customize two fluorescence excitation positions or all 6 emission positions to your needs
Detector PIN-photodiode
Light Source Wavelength-matched LED
Read Position Top reading
Wavelengths selection Filter module with 5 standard excitation and emission filters. Empty filter
positions are available for custom excitation and emission wavelengths.
Wavelengths included UV (Ex: 365nm, Em: 415–445nm) Blue (Ex: 475nm, Em: 500–550nm)
Green (Ex: 525nm, Em: 580–640nm) Red (Ex: 625nm, Em: 660–720nm)
AFC (Ex: 405nm, Em: 495–505nm)
Detection Limit 2fmol fluorescein/200μl
Linear Dynamic Range >6 logs (assay dependent)
GloMax Systems Specifications
®
Absorbance
• GloMax® Discover comes factory installed with 9 UV-Visible filters for common colorimetric assays
• GloMax® Explorer GM3500 comes factory installed with 5 Visible Absorbance filters
• Ideal for ELISA, protein and nucleic acid assays
PROMEGA CORPORATION • 2800 WOODS HOLLOW ROAD • MADISON, WI 53711-5399 USA • TELEPHONE 608-274-4330
www.promega.com • © 2015 PROMEGA CORPORATION • ALL RIGHTS RESERVED • PRICES AND SPECIFICATIONS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE • PUBLISHED IN USA 3/15 • 16342722 • PART BR261