0% found this document useful (0 votes)
51 views

DesignRIPEND PDF

This document provides specifications for various reverse osmosis membrane systems including: - Average and maximum flux rates for different membrane types and applications - Expected flux decline and salt passage increase percentages over time - Feed and reject flow rates for membrane elements of varying sizes - Typical operating pressures and pressure limits - Saturation limits for scaling potential under different water qualities It notes the performance estimates are based on nominal membrane performance with feed water of acceptable quality and no guarantees are made unless stated in a separate warranty document.

Uploaded by

jegadish
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
51 views

DesignRIPEND PDF

This document provides specifications for various reverse osmosis membrane systems including: - Average and maximum flux rates for different membrane types and applications - Expected flux decline and salt passage increase percentages over time - Feed and reject flow rates for membrane elements of varying sizes - Typical operating pressures and pressure limits - Saturation limits for scaling potential under different water qualities It notes the performance estimates are based on nominal membrane performance with feed water of acceptable quality and no guarantees are made unless stated in a separate warranty document.

Uploaded by

jegadish
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Designed for RIPEND

Brackish Muni Muni


Brackish Brackish Brackish Sea Sea
Well Sea Well Teritary Teritary RIP
Parameter Unit Level Well High- Surface Surface Surface Surface
Non- Conv. Waste Waste
Fouling Conv. MF/UF Conv. MF/UF
Fouling Conv. MF/UF
System lmh Typical 12 22.1 20.4 27.2 17.0 13.6 17.0 17.0 20.4 35.6
Average flux lmh Aggressive 28 28.9 27.2 30.6 20.4 17.0 20.4 20.4 23.8 42.4

Max lmh Typical 45.8 32.3 31 35.6 42.4 34.0 42.4 25.5 27.2 56.0
Element flux

Flux decline % Typical 5 7 7 7 5 7 5 15 12 3


(per year)

Salt Passage Typical 7 7 10 7 7 10 7 12 10 5


Increase % (per year)

Beta Typical 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.5
Standard element

Beta Typical 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.3 1.3 2.2
Full fit element

Feed
(Maximum per vessel)
2.5" m3/h Typical 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4
4.0" m3/h Typical 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6
8.0" m3/h Typical 17.0 17.0 17.0 17.0 17.0 17.0 17.0 17.0 17.0 17.0
8.0" (34 mil) m3/h Typical 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3
16.0" m3/h Typical 68.1 68.1 68.1 68.1 68.1 68.1 68.1 68.1 68.1 68.1

Reject
(Minimum per vessel)
2.5" m3/h Typical 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.2
4.0" m3/h Typical 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.8 0.7 0.5
8.0" m3/h Typical 2.7 2.7 2.7 2.7 2.7 2.7 2.7 3.2 2.7 1.4
16.0" m3/h Typical 10.9 10.9 10.9 10.9 10.9 10.9 11.0 12.8 10.9 7.3
4.0" full fit m3/h Typical 1.4 1.4 1.4 1.4 1.4 1.4 1.4 2.1 1.4 1.4
8.0" full fit m3/h Typical 5.7 5.7 5.7 5.7 5.7 5.7 6.8 7.9 5.7 4.5

Pressure drop
6-M vessel bar Typical 1.72 1.72 1.72 1.72 1.72 1.72 1.72 1.72 1.72 1.72
6-M vessel bar Maximum 3.45 3.45 3.45 3.45 3.45 3.45 3.45 3.45 3.45 3.45
Element bar Typical 1.03 1.03 1.03 1.03 1.03 1.03 1.03 1.03 1.03 1.03
Element bar Maximum 1.03 1.03 1.03 1.03 1.03 1.03 1.03 1.03 1.03 1.03

Saturation limits with


Anti scalant
LSI (< 10000 ppm TDS) Typical 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8
CaSO4 (%) Typical 400 400 400 400 400 400 400 400 400 400
SrSO4 (%) Typical 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200
BaSO4 (%) Typical 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000
Ca3(PO4)2 SI Typical 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4
SiO2 (%) Typical 140 140 140 140 140 140 140 140 140 140
CaF2 (%) Typical 50000 50000 50000 50000 50000 50000 50000 50000 50000 50000
CCPP (mg/l) Typical 850 850 850 850 850 850 850 850 850 850

Product performance calculations are based on nominal element performance when operated on a feed water of acceptable quality. The results shown on the printouts produced by this program are
estimates of product performance. No guarantee of product or system performance is expressed or implied unless provided in a separate warranty statement signed by an authorized Hydranautics
representative. Calculations for chemical consumption are provided for convenience and are based on various assumptions concerning water quality and composition. As the actual amount of
chemical needed for pH adjustment is feedwater dependent and not membrane dependent, Hydranautics does not warrant chemical consumption. If a product or system warranty is required, please
contact your Hydranautics representative. Non-standard or extended warranties may result in different pricing than previously quoted.