This document contains a test paper for an online HVAC training with 35 multiple choice questions covering topics like analog and digital inputs/outputs, common HVAC devices and their functions, DDC controllers and networking. The test paper includes questions about Trend controllers, their specifications, IP addressing and interfacing features. It also contains questions about control system components like VAV, VFD, chillers, cooling towers and their applications in HVAC systems.

Uploaded by

nts
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (3 votes)
481 views

Quiz-Trend Module-1 Online Training

This document contains a test paper for an online HVAC training with 35 multiple choice questions covering topics like analog and digital inputs/outputs, common HVAC devices and their functions, DDC controllers and networking. The test paper includes questions about Trend controllers, their specifications, IP addressing and interfacing features. It also contains questions about control system components like VAV, VFD, chillers, cooling towers and their applications in HVAC systems.

Uploaded by

nts
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 20

Test Paper for Trend Module 1 Online Training

(HVAC Basic & SET)


Name: M.Chaitanya Company Name: METAS
Mob. No. 9030080334 Email Id: [email protected]

1) Which of below are example of analog output:

A AHU run status

B Room Humidity

C AHU Valve Modulation

D Auto Manual Status

2) Which of below devices are used to modulate the AHU speed:

A VAV

B VRV

C VFD

D PHE

3) What protocol does an IQeco controller communicates?

A LON

B MSTP

C Ethernet

D Current Loop

4) Which of the below controller cannot be upgraded to IQ Interfacing feature?

A IQ4E/32/BAC/230

B IQ4E/96/XNC/BAC/230

C IQ4E/64/BAC/230

D IQ4E/96/BAC/230

Page 1 of 20
5) What type of input would a SRMV relay module expect?

A Analogue 0 & 10vdc

B Digital

C Triac

D Any of the above depending on its configuration

6) What will be the output of G6 & G12 respectively:

A 0&0

B 1&1

C 0&1

D 1&0

7) What will be the output of F24?

A 25

B 0

C 27

Page 2 of 20
D 2

Page 3 of 20
8) Refer logic for Question 7; assume K13 value as 15 & W19 value as 0;
now what will be the F24 output?

A 25

B 0

C 27

D 2

9) What is a Trend CNC?

A Computer Numerical Control

B Communications Node Controller

C Controller Number Count

D Configurable Network Computing

10) What is the maximum user configurable address per Trend LAN ?

A 126

B 116

C 256

D 119

11) Can RS485 & RS232 both ports be used for Modbus RS485 integration on
IQ4 controller with IQ Interfacing feature?

A Yes

B No

12) Which of the following Network connections are available for the IQview4?

A RS232 Only

B RS232, Current Loop, Ethernet

C MS/TP, RS485

D B&C

Page 4 of 20
13) What does INC stand for?

A Intermediate Node Communicator

B Internetwork Node Communicator

C Internetwork Node Controller

D None of the above

14) What are the first 6 hex digits in the MAC address for all Trend Ethernet devices

A A00:01:10

B A00.10.70

C A00:10:10

D A00:10:70

15) Which of the following IP addresses would access an IQ4’s WEB Pages

A 128.168.73.21:25

B 128.168.73.21:80

C 128.168.73.21:10024

D 128.168.73.21:2774

16) What is the function code to read holding register in XNC string?

A F03

B F04

C F05

D F06

17) To transfer data from one DDC to another we use_____

A Loop

B Timer

C ICComms

D Counter

Page 5 of 20
18) How many max expansion module can get connected on one TONN8?

A 1

B 2

C 3

D 4

19) How many maximum IQ4 IO modules can get connected to IQ4 controller?

A 10

B 20

C 30

D 40

20) What is the overall maximum range from Base controller to last IO modules
using belden standard cable, when all IQ4 Ios are connected to IQ4E?
A 200 Meter

B 300 Meter

C 800 Meter

D 1.2 Km

21) How many + 24VDC Auxiliary power terminals available in IQ4E controller?

A 1

B 2

C 3

D 4

22) What is the maximum current provided by all 24VDC Auxiliary Terminals?

A 240 mA

B 120 mA

C 130 mA

D 260 mA

Page 6 of 20
23) In below options, which controller is available under Trend Portfolio?

A IQeco34 controller

B IQeco31 controller

C IQeco36 controller

D IQeco39 controller

24) What are the analog inputs acceptable by IQ4 controllers?

A Current input

B Voltage input

C Thermistor input

D All of the above

25) What are the analog outputs provided by IQ4 controllers?

A Current output

B Voltage output

C Both voltage & current output

D None of the above

26) TREND loop network follows which unidirectional path:

A Tx to Rx

B Rx to Tx

C Any of the above two

D None

27) Which are XNC variants controllers are available:

A IQ4E/96/XNC/BAC/230

B IQ4E/96/XNC/BAC/24VAC

C IQ4E/96/XNC/LAN/BAC/230

D All the above

Page 7 of 20
28) The error signal generated in closed loop system is fed to which of the following:

A Controlled Device

B Controlling Device

C Sensor

D None Of The Above

29) CO2 level in a conditioned space has risen above set point. What will you do?

A Increase cooling

B Shut down the AHU fan

C Increase outside air intake into the AHU

D All the above

30) What is the function of condenser in a water cooled chiller

A Cools down the cooling tower

B Cools down refrigerant

C Cools down condenser water

D All the above

31) Cooling tower is used to:

A Reduce the temperature of chilled water

B Cool the refrigerant used in the chiller

C Cool the surrounding air

D Cool the condenser water

32) In Pressure Dependent VAV system

A VAV Outlet Air Flow decreases with increase in demand

B VAV Outlet Air Flow increases with decrease in inlet air pressure

C VAV Outlet Air Flow increases with Increase in inlet air pressure

D VAV Outlet Air Flow do not change with Increase in inlet air pressure

Page 8 of 20
33) What are the address we cannot assigned to Controller and Trend LAN

A 2,4 and 256

B 2,3 and 10

C 0, 13 and 17

D 0, 1 and 2

34) A transducer gives out a signal in the range of 4 to 20mA. Your DDC can accept
only a range of 2 to 10VDC (i.e. a voltage signal). What will you use to convert
current to voltage?

A Connect Resistance in series with input terminals (250 Ohm)

B Connect Resistance in series with input terminals (500 Ohm)

C Connect Resistance in parallel with input terminals (250 Ohm)

D Connect Resistance in parallel with input terminals (500 Ohm)

35) An external device that sends a proportional or continuously changing signal


to the controller is

A Analog Input

B Analog Output

C Digital Input

D Digital Output

36) An external sensor that sends a two-state, on-off, or two-position signal


to a controller is a:

A Analog Input

B Analog Output

C Digital Input

D Digital Output

37) Which of the following is more advantageous for transmission of signals?

A Votage Signal

B Current Signal

C Both Current and Voltage signals have same advantages

D None
Page 9 of 20
38) What is the function of secondary chilled water pumps?

A Transfer water from cooling tower to chiller

B Transfer water from chiller to cooling tower

C Transfer water from load to chiller

D Transfer water from chiller to load

Page 10 of 20
ng

(1 Marks)

(1 Marks)

(1 Marks)

(1 Marks)

Page 11 of 20
(1 Marks)

(5 Marks)

(5 Marks)

Page 12 of 20
Page 13 of 20
(5 Marks)

(1 Marks)

(1 Marks)

(1 Marks)

(1 Marks)

Page 14 of 20
(1 Marks)

(1 Marks)

(1 Marks)

(1 Marks)

(1 Marks)

Page 15 of 20
(1 Marks)

(1 Marks)

(1 Marks)

(1 Marks)

(1 Marks)

Page 16 of 20
(1 Marks)

(1 Marks)

(1 Marks)

(1 Marks)

(1 Marks)

Page 17 of 20
(1 Marks)

(1 Marks)

(1 Marks)

(1 Marks)

(1 Marks)

Page 18 of 20
(1 Marks)

(1 Marks)

(1 Marks)

(1 Marks)

(1 Marks)

Page 19 of 20
(1 Marks)

Page 20 of 20

You might also like