INTRODUCTION
Tools and equipment which is not check before it will use it may cause an accident in a
food processing area. With regular inspection you can make sure your equipment is in
good condition and it will function well. A trained technician can determine if small
repairs will make a big difference and can suggest repairs to help your equipment run
more efficiently. An equipment inspector may point out details your team might tend
to overlook.
Most importantly, regular checking of the equipment may ensure the safety of
your workers. They will also think and function efficiently. Also, if the tools and
equipment is in good condition a food processing industry may produce a good quality
products and productive workers.
The lesson deals with how to pre-operational check the different basic
equipment used in Food (Fish) Processing. This includes the procedures in pre-
operational check of the equipment in food processing.
LEARNING COMPETENCY:
Select and Prepare Equipment for use (TLE_AFFP10-OE-Ic-1)
DURATION
This module will be covered for one-week discussion.
LEARNING OBJECTIVES:
At the end of this module you are expected to:
1. identify the faulty and damage machine/equipment according to workplace
requirements;
2. carry out the routine of pre-operational checks of the tools and equipment in
food processing; and
3. arrange steps in cleaning of equipment.
Republic of the Philippines
Department of Education
Region III - - Central Luzon
Schools Division OF CITY OF MEYCAUAYAN
MEYCAUAYAN NATIONAL HIGH SCHOOL
Camalig, City of Meycauayan, Bulacan
_____________________________________________________________________________________________
_________________________________
CONTENT:
Pre-Assessment:
1. What type of water is used in calibrating the refractometer?
a. Distilled water b. Lukewarm water c. Sea water d. Water from the faucet
3. How many drops of sap or syrup sample are needed in testing the refractometer?
a. four b. one to two c. three d. two to three
b. Check its accuracy by dipping in hot foods if the mercury rises to desired
temperature.
c. Confirm that the prism is clean and free from scratches.
d. Check for any cracks, leaks, or breakage.
10. What is the first step you should when defrosting the refrigerator?
a. Turn on the freezing unit.
b. Refill the ice cube tray.
c. Turn off the freezing unit.
d. Wash the ice cube tray.
Republic of the Philippines
Department of Education
Region III - - Central Luzon
Schools Division OF CITY OF MEYCAUAYAN
MEYCAUAYAN NATIONAL HIGH SCHOOL
Camalig, City of Meycauayan, Bulacan
Keypoints
Engage Motivation
Directions. Observe the pictures below. Draw a thumbs up sign if the picture
shows right using of the equipment and thumbs down if not.
1. 2.
3. 4.
Discover
Equipment, standard tools and devices need to be checked and procedures for used
reviewed based on the manufacturer ‘s specifications. The table below is a list of
standard measuring devices and equipment, and their procedures on for use.
EQUIPMENT, TOOLS/ PRE- OPERATIONAL PROCEDURE FOR USE
DEVICES CHECK
A. Standard Measuring Device
1. Thermometer Check its accuracy by Dip thermometer in
dipping in hot foods if the boiling liquids. Record the
3
Republic of the Philippines
Department of Education
Region III - - Central Luzon
Schools Division OF CITY OF MEYCAUAYAN
MEYCAUAYAN NATIONAL HIGH SCHOOL
Camalig, City of Meycauayan, Bulacan
4
Republic of the Philippines
Department of Education
Region III - - Central Luzon
Schools Division OF CITY OF MEYCAUAYAN
MEYCAUAYAN NATIONAL HIGH SCHOOL
Camalig, City of Meycauayan, Bulacan
1. Refrigerator/Freezer
A. What to Check
5
Republic of the Philippines
Department of Education
Region III - - Central Luzon
Schools Division OF CITY OF MEYCAUAYAN
MEYCAUAYAN NATIONAL HIGH SCHOOL
Camalig, City of Meycauayan, Bulacan
Practice Drills
Activity 1
Directions. Matching type. Connect the devices in Column A with its Pre-
operational check in column B. Write your answer on the space provided before
each number.
Column A Column B
Activity 2
Directions. Read the procedure of the tools and equipment then identify what
device is being use in each procedure. Write your answer inside the box.
1. Pour liquid until the desired level of measuring cup. Have the
measuring lines at eye level to be sure of exact measurement.
Activity 3
Directions. Write a sentence that describes the picture on how to use refrigerator.
Write your answer inside the box after each picture.
6
Republic of the Philippines
Department of Education
Region III - - Central Luzon
Schools Division OF CITY OF MEYCAUAYAN
MEYCAUAYAN NATIONAL HIGH SCHOOL
Camalig, City of Meycauayan, Bulacan
1.
2.
3.
4.
5.
Activity 4:
Directions. Read the steps in defrosting of refrigerator then arrange it in proper
order. Use letter a-f in arranging. Write your answer inside the circle before each
number.
7
Republic of the Philippines
Department of Education
Region III - - Central Luzon
Schools Division OF CITY OF MEYCAUAYAN
MEYCAUAYAN NATIONAL HIGH SCHOOL
Camalig, City of Meycauayan, Bulacan
1. Wash the refrigerator and the drip pan. Never try to speed up defrosting by
prying off ice.
4. Refill the ice cube pan with warm water not hot water, and place it on the
bottom shelf of the freezing unit
5. Keep the drip tray in place to catch the melting ice.
6. Wash and refill the ice cube tray.
Summary:
Every equipment must be check before it will be used to avoid any kind of
accidents. Here are some devices commonly used in food processing that must be
check regularly.
Device Pre-operational Check
1. Thermometer Check its accuracy by dipping in hot
foods if the mercury rises to desired
temperature.
2.Salinometer Check the accuracy by measuring 200
salinometer brine solution. Check if the
salinometer records the reading
correctly.
5.Graduated cylinders and Beaker Check for any cracks, leaks, or breakage
6. Measuring cups for dry ingredients Check for any cracks, leaks, or breakage
7. Measuring Cup for Liquid Ingredients Check for any cracks, leaks, or breakage
8
Republic of the Philippines
Department of Education
Region III - - Central Luzon
Schools Division OF CITY OF MEYCAUAYAN
MEYCAUAYAN NATIONAL HIGH SCHOOL
Camalig, City of Meycauayan, Bulacan
Post-Assessment:
Directions. Fill in the blanks with correct answer. Write your answer on the blanks.
3. Put ___________ drops of sap or syrup sample are needed in testing the
refractometer.
5. A ______________ device must check the prism if it is clean and free form
scratches.
10. __________ the freezing unit is the first step you should when defrosting the
refrigerator.
REFERENCES:
Prepared:
MYRA T. DE JESUS
Teacher II
Evaluated:
9
Republic of the Philippines
Department of Education
Region III - - Central Luzon
Schools Division OF CITY OF MEYCAUAYAN
MEYCAUAYAN NATIONAL HIGH SCHOOL
Camalig, City of Meycauayan, Bulacan
EVANGELINE F. CORAŇES
Head Teacher IV, TLE Department
Approved:
BENITA P. ESPE
Assistant Principal II, Junior High School
Noted:
ROSALINA G. SANTOS, EdD
Principal IV
10