Manual OUT50M

The document provides an overview of the ZXMSG 5200 Multiplex Service Gateway OUT50M. The OUT50M is an outdoor cabinet that provides 256 POTS users or 128 ADSL/ADSL2+ connections. It has a compact structure suitable for outdoor use with insulation, low noise, and a speed-adjusted fan. The cabinet contains modules like an 8-slot user access unit, control and switching card, storage batteries, fan unit, power distribution, and environmental monitoring. The OUT50M shelf fits in the cabinet and contains card slots for user, control, power, and monitoring cards to provide telecom services and monitoring functions through the integrated access device.

Uploaded by

Sergio Sanchez
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
65 views

Manual OUT50M

The document provides an overview of the ZXMSG 5200 Multiplex Service Gateway OUT50M. The OUT50M is an outdoor cabinet that provides 256 POTS users or 128 ADSL/ADSL2+ connections. It has a compact structure suitable for outdoor use with insulation, low noise, and a speed-adjusted fan. The cabinet contains modules like an 8-slot user access unit, control and switching card, storage batteries, fan unit, power distribution, and environmental monitoring. The OUT50M shelf fits in the cabinet and contains card slots for user, control, power, and monitoring cards to provide telecom services and monitoring functions through the integrated access device.

Uploaded by

Sergio Sanchez
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 16

ZXMSG 5200

Multiplex Service Gateway


OUT50M

Version 2.0.3

ZTE CORPORATION
NO. 55, Hi-tech Road South, ShenZhen, P.R.China
Postcode: 518057
Tel: (86) 755 26771900
Fax: (86) 755 26770801
URL: http://ensupport.zte.com.cn
E-mail: [email protected]
Contents

Preface..............................................................2
Introduction ......................................................3
Overview....................................................................... 4
Equipment Description .................................................... 5
Features........................................................................ 6
Device Configuration ....................................................... 7
Cabinet Configuration.................................................. 8
OUT50M Shelf Configuration ........................................ 9
Card Configuration.....................................................10
Cabinet Composition ......................................................11
Technical Specifications ..................................................12
Technical Index .............................................................13
Performance Index ........................................................14
Device Interface Index ...............................................15
Reliability Index ........................................................16

Confidential and Proprietary Information of ZTE CORPORATION 2


Introduction

Table of Contents
Overview........................................................................... 1
Equipment Description ........................................................ 1
Features............................................................................ 2
Device Configuration ........................................................... 3
Cabinet Composition ........................................................... 8
Technical Specifications ......................................................10
Technical Index .................................................................12
Performance Index ............................................................12

Overview
OUT50M is SS (soft-switching equipment MGC) access equipment.
OUT50M interacts with SS (or MGCP) through H.248 protocol.
OUT50M, which consists of control panel, media resource board,
test board and a number of user boards, converges a number of
narrow-band telephone access and broadband access. Telephone
service is provided by the SS, and broadband service is provided
by the Internet.
OUT50M can be installed in indoor and outdoor cabinets.
This manual introduces OUT50M OUT50M Outdoor Cabinets (here-
inafter referred to as OUT50M).

Equipment Description
The OUT50M cabinet is designed precisely with compact struc-
ture, light and nice shape, low noise, and good insulation with
speed-adjusted fan. It is suitable for the outdoor environment re-
quirements.
The whole structure includes the roof, the primary device cabin,
the cable distribution cabin, the storage battery cabin, and the
pole-mounted device.
The standard configuration inside the cabinet includes:
� A user access unit, including eight user card slots support-
ing 256 POTS users and/or 256 ADSL users, one main control and

Confidential and Proprietary Information of ZTE CORPORATION 3


ZXMSG 5200 Hardware Installation Manual (OUT50M)

switching card GISB, and one independent power environment


monitoring system
� A group of 24 AH/38 AH storage batteries
� A fan unit
� A power distribution box
� An optical fiber fusion plate (optional)
� An MDF cable distribution module
Figure 1 shows the OUT50M cabinet outline.

FIGURE 1 CABINET OUTLINE

Features
Application The OUT50M is applied in the outdoor environment, providing 256
POTS users or 128 ADSL/ADSL2+ access service.
Structure The overall machine is a riveted and welded cabinet assembled
with three cabinet doors, the MDFs and the rails. The cabinet fea-

4 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 Introduction

tures good airtightness, insulation and a reliable connection way.


The cabinet integrates all kinds of functional modules, such as the
storage battery, power monomer, optical fiber fusion plate, inte-
grated access unit, environment monitoring unit, and MDF.
112 Test � 112 narrowband testing interface provided by the testing card
TSLC
� ADSL testing interface provided by the ADL/GADL card (An ex-
ternal tester can be connected to perform a test.)
Monitoring The OUT50M cabinet achieves the power failure and monitor the
temperature, humidity, flood, smog and door control through the
self-contained environment monitoring unit and NMS.
The EPM unit is primarily composed of the sensor module and the
EPM device. The sensor module includes all kinds sensor modules,
such as temperature, humidity, flood, smog, and door control. The
sensor module conveys the signals to the EPM device to realize the
environment monitoring function.
The EPM unit collects the information from each sensor and MDF
module and communicates with the integrated access devices
through the serial ports. The integrated access device forwards
the environment power alarm information to the upper-layer
background NM unit at the office-end equipment room to achieve
the environment monitoring function.
Power The power supply equipment consists of power distribution unit
and power monomer. The power monomer supplies the overall
system with the reliable and constant power together with the stor-
age batteries.
The 220 V power cable goes into the cabinet from the bottom of
the cable distribution cabin and into the power monomer; then the
power-monomer-led-out cable supplies the user shelf with power
through the AC power distribution box.
The whole machine has a dedicated anti-lightning relay modules
on the power-incoming terminal. Inside the module, there are
the breaker, power anti-lightning device and wave-filtering de-
vice. The cabinet has the dedicated and reliable grounding chan-
nel, which makes the cabinet anti-lightning more reliable.

Device Configuration
This topic includes the following:
� Cabinet Configuration
� OUT50M Shelf Configuration
� Card Configuration

Cabinet Configuration
The OUT50M cabinet is grey in appearance and 980 mm x 750
mm x 480 mm (Height x Width x Depth) in dimension. The cab-

Confidential and Proprietary Information of ZTE CORPORATION 5


ZXMSG 5200 Hardware Installation Manual (OUT50M)

inet consists of one user access unit, one group of 24 AH/38 AH


storage batteries, one fan unit, one power distribution box, one
optical fiber fusion plate (optional) and the MDF cable distribu-
tion module. One cabinet is installed with one OUT50M shelf. The
OUT50M cabinet configuration is shown in Figure 2.

FIGURE 2 OUT50M CABINET CONFIGURATION

OUT50M Shelf Configuration


Shelf Structure The OUT50M cabinet is configured with 9U-high OUT50M front out-
let shelf. The shelf dimension is 445.5 mm x 352.8 mm x 318.5
mm (Height x Width x Depth). Figure 3 shows the OUT50M shelf
structure.

6 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 Introduction

FIGURE 3 OUT50M SHELF STRUCTURE

Shelf Configura- The shelf is 9 U high. The upper 6 U of the shelf is occupied with
tion each kind of card slot. The lower 3 U of the shelf is for the corre-
sponding extended cards which includes the extended power card,
the extended main control card, the extended user card. Table 4
lists the OUT50M extended cards.

TABLE 4 EXTENDED CARD

Extended Card Description

IEBD
Extended main control card
IEBE

SEB Extended user card (ALC, GADL)

PEB Extended power card

EPEB Extended EPC card

Confidential and Proprietary Information of ZTE CORPORATIO 7


ZXMSG 5200 Hardware Installation Manual (OUT50M)

Figure 4 shows the typical configuration of the OUT50M shelf.

FIGURE 4 OUT50M SHELF CONFIGURATION

The OUT50M shelf has two power slots, two main control card slots
and eight user card slots.
The two slots on the right side of the shelf are for the power card
POWER K. The media resource cards MPR/MPRB can be inserted
in the slots LC5 and LC6. If the testing function is needed, a TSLC
(TSLCD/TSLCE) testing card can be inserted in any of the user slot.
If the EPM function is needed, an EPC card can be inserted in any
of the user slot. If the ODTI card is needed, it can be inserted in
the user card slots LC4, LC5 and LC6.

Card Configuration
Table 5 lists the card types.

TABLE 5 CARD TYPES

Card Type Name Description

ICS Integrated control and switching card

Enhanced integrated control and


EICS
switching card

Main control and Gigabit control and switching card


GISS
processing card (simplified)

GIS Gigabit control and switching card

Gigabit control and switching type-B


GISB
card

Main control Network address translation module


CNIC
sub-card card

MAPP APP network processor

8 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 Introduction

Card Type Name Description

MPR Packet processing and resource card


VoIP processing
card Type-B packet processing and re-
MPRB
source card

ALC Analog use card

Analog user card RALC Polar-reverse analog user card

FLC Remote user card

16-port integrated voice and data


GILC
user card
Integrated user
line user card
32-port integrated voice and data
GELC
user card

DLCC Digital user card


Digital user card
DLCE Digital user card E

ADL ADSL/ADSL2+ user card

GADL Enhanced ADSL/ADSL2+ user card


Broadband user
card
GVDL 16-port VDSL+ user card

GSDL 16-port SHDSL user card

EPON user card EPOL Single-port remote EPON card

GETI Ethernet switching interface card


Ethernet interface
ETC Ethernet interface card
card
GETC Gigabit Ethernet interface card

ODTI 8-port digital trunk interface card


Trunk interface
card
HDTI 16-port digital trunk interface card

ATM interface
GATI ATM interface card
card

GPON ONU inter-


GPNI GPON ONU interface card
face card

Testing card TSLC User testing card

Power card PPC Power card

POWER K Type-K power card

EPC card EPC EPC card

Confidential and Proprietary Information of ZTE CORPORATION 9


ZXMSG 5200 Hardware Installation Manual (OUT50M)

Card Type Name Description

IEBD
Extended main control card
IEBE

Extended card SEB Extended user card

PEB Extended power card

EPEB Extended EPC card

Cabinet Composition
The OUT50M equipment contains the power supply modules, con-
trol and processing module, test module, the user access module,
monitoring module, temperature control module, and anti-light-
ning module.
Power Supply The 220 V power cable goes into the cabinet from the bottom of
Module the cable distribution cabin. After the power cable goes into the
cabinet, it goes into the power monomer through power allocation
and then the power monomer led-out cable supplies the power to
the user shelf through DC power distribution box.
1. Power Distribution Unit
The AC/DC power distribution unit introduces the AC power
for the outdoor device. The unit includes the air switch,
anti-lightning device, wave-filtering device and ground row.
The AC/DC power unit resides between the AC power and the
power monomer (namely AC/DC translation module). It has
the functions of AC power connection, allocation, switching
control, lightning protection, over-circuit protection, bi-direc-
tional wave-filtering and grounding.
2. Power Monomer
The power monomer is compatible with the 110 V AC/220 V
AC power input modes.
The power monomer, namely AC/DC translation module, works
to supply the outdoor devices with power and translate the 220
V AC power to –48 V DC power, providing the DC power to the
broadband network access devices and auxiliary devices.
The power monomer includes two independent redundant
modules to achieve power backup functions. When one
redundant module is faulty, the another module can continue
to work, translating the AC power to DC power. The AC/DC
translation module is connected to environment monitoring
unit through a serial communication interface, which works to
display the over/under voltage alarm and fault monitoring.
3. The power supply module POWER K is used to provide the sec-
ond-time power and ringing to each user-layer. It outputs four
types of voltages: +5 V, -5 V, -48 V and ringing 75 V AC.
4. Storage Battery
The storage battery provides the device with -48 V power.

10 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 Introduction

The connection of the storage battery unit and the power


monomer can provide the backup DC power to the integrated
access outdoor device. When the power supply is faulty and
the AC power cannot supply the power properly, the system
can switch to the storage battery automatically to achieve the
backup power supply function. The power monomer has the
storage battery monitoring unit to monitor the recharging and
discharging of the battery.
Control and The control and switching cards ICS/GIS/GISB are the core pro-
Processing Module cessing cards of the system. They work to scan the circuit status
of the downstream user interface cards and manage them. The
control and switching card provides maximally 16 K x 16 K TDM
switching, supports E1 upstream, FE/GE Ethernet upstream and
EPON/GPON upstream, and makes exchanges between the down-
stream user card slot and one user test card slot and other shelf 8
MHW or 16 MHW. Meanwhile, the control and switching card is ca-
pable of converging and exchanging the Ethernet bus, processing
the Ethernet layer-2 protocol, and extending the IP layer-3 proto-
col.
Test Module The test module uses the user test card TSLC to perform the inter-
nal/external line test, the user telephone function, and the plug-in
monitoring function.
User Access OUT50M supports the NGN POTS users and broadband users. The
Module OUT50M cabinet can be configured with the built-in MDF and in-
stalled with the internal line module and the external line module.
Through the external line module, the cabinet connects the user
cables.
Monitoring Module The monitoring module has the following functions:
� Environment alarm monitoring including temperature, humid-
ity, smog, door control and flood
� 28-port digital input monitoring
� 16-port digital input control
� 5-port analog input monitoring
� 3-port RS232 serial communication
Temperature The OUT50M cabinet adopts the natural convection for insulation.
Control Module The air inlet is installed between the device cabin and the battery
cabin. The whole roof is used for outlet. The insulation method
guarantees the cabinet to work in a high temperature of 55 ℃.
Anti-Lightning The anti-lightning function is achieved through the AC/DC power
Module distribution unit. The AC/DC power distribution unit introduces the
AC power for the outdoor device. The unit includes the air switch,
anti-lightning device, wave-filtering device and ground row. It has
the functions of switching control, lightning protection, over-circuit
protection, bi-directional wave-filtering and grounding.
The protector module located inside the cable distribution module
has the anti-lightning function as well. The protector unit and the
user card protect the layer-2 user terminal. The protector unit
uses the polymeric (or ceramic) PTC and semiconductor discharge
tube and is designed with integrated over-voltage/over-circuit pro-
tection. It has the anti-lightning and over-voltage alarm function.
� Power and battery: the primary power and the two-time power
pass the anti-lightning module guarantee. The battery passes
the primary power anti-lightning module guarantee. The anti-

Confidential and Proprietary Information of ZTE CORPORATION 11


ZXMSG 5200 Hardware Installation Manual (OUT50M)

lightning complies with the Q/ZX23.021-2005 Communication


Equipment Project Reliability Regulation.
� The power distribution box is designed with the anti-lightning
module and filter, which guarantees the cabinet AC power
safety.
� Cable distribution: The external and internal lines are equipped
with protector unit. The protector is free from lightning, over-
voltage, over-circuit and achieve self-protection through the
cabinet grounding.
� User circuit interface part: The circuit interface is equipped
with the special anti-overvoltage and anti-overcurrent devices
to protect the internal circuit.
� The cabinet has a dedicated and reliable grounding channel,
which makes the cabinet lightning protection more reliable.

Technical Specifications
Syntax The OUT50M device complies with the following technical specifi-
cations, as shown in Table 6.

TABLE 6 TECHNICAL SPECIFICATIONS

Technical
Name
Specifications

Telephone switching equipment general specifica-


YDN 065-1997
tion of MPT

Synchronous optical transmission network technol-


YDN 099-1998
ogy system

YDN 108-1998 V5.2 interface conformance testing specification

Local telephone network management technique re-


YDN 033-1997
quirements

YDN 034.2-1997 ISDN user – Network Interface Specification

SDH transmission network management technology


YDN 086-1998
system

Automatically switched telephone (digital) network


YDN 088-1998
technology system

Telecom switching equipment over-voltage


YD/T 950-1998 over-current protection technical requirements and
test method

Allocation of transmission performance index in ac-


YD/T1007-1999
cess network

YD/T1033-2000 Index series of transmission performance

12 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 Introduction

Technical
Name
Specifications

Technology requirement and test method of stand


YD/T1011-1999 alone synchronization equipment in digital synchro-
nization network

Digital synchronization network node clock series


YD/T1012-1999
and the timing characteristics

YD/T1061-2000 The LAPS specification of IP over SDH same as X.85

YD/T1022-1999 SDH equipment functional requirements

Gigabit Ethernet switch equipment technical speci-


YD/T1099-2001
fications

YD/T1141-2001 Gigabit Ethernet switch test method

Access networks technical requirements - Ethernet-


YD/T1160-2001
based broadband access technologies

Technical requirements of SDH-based multi-service


YD/T1238-2002
transmission node

Technical requirements and test methods of 2048


GB-T 6879-1995
kbit/s 30-way Pulse Code Modulation MUX

Telephone switching equipment general specifica-


GF002-9002
tion of MPT

Application environmental conditions of electrical


GB4798.1-86
and electronic products (storage)

Application environmental conditions of electrical


GB4798.2-84
and electronic products (transport)

GIB-Z35-93 Component derate criterion

General outline of reliability in equipment develop-


GJB450-88
ment and production

Reliability prediction handbook of electronic equip-


GJB-299A-91
ment

ANSI/IEEE Std
1998 Edition MAC network bridge
802.1D

Series digital interface physical / electrical charac-


ITU-T G.703
teristics

All synchronization frame of primary rate and sec-


ITU-T G.704
ondary group series grade

ITU-T G.960 Digital section for ISDN basic access

Digital transmission system on metallic local lines


ITU-T G.961
for ISDN basic rate access

ITU-T G.962 Digital Section for ISDN primary rate access

Confidential and Proprietary Information of ZTE CORPORATION 13


ZXMSG 5200 Hardware Installation Manual (OUT50M)

Technical
Name
Specifications

ISDN basic access userThe first tier network inter-


ITU-T I.430
face specification

ISDN primary rate access user The first tier network


ITU-T I.431
interface specification

Technical Index
Equipment Size � Dimension
and Weight
Cabinet dimension: 980 mm x 750 mm x 480 mm (Height x
Width x Depth
� Weight
� Net weight: 96 kg (without storage battery)
� 128 kg (with 24 AH storage battery in full equipment)
� 140 kg (with 38 AH storage battery in full equipment)
Working � Humidity: 5% - 95%
Environment
� Temperature: -15 ℃ – 45 ℃
� Atmospheric pressure
Working: 1.08×105 - 5.1×104 Pa
Storage: 1.08×105 – 1.2×104 Pa
� Solar radiation ≤ 1120 W/m2
� Wind-resistant capability: 60 m/s
� Earthquake-resistant capability: 7 degree
Air pollution requirements
Avoid the product from being exposed to corrosive gases such
as hydrogen sulfide, sulphur dioxide, nitrogen oxides and
smog.
� Electromagnetic interference: field density ≤ 140 dBµV/m, fre-
quency range: 0.01 MHz - 110000 MHz
� Anti-rain and anti-dust: In compliance with IEC IP 5.5 level,
the primary parts surface is processed by a special technique
and has strong corrosion resistance.
Power Supply Input working voltage: 220 V AC ± 20, 110 V AC ± 20, frequency
Requirements fluctuation range: ≤5%, line voltage wave aberration 5%.
Power 200 W
Consumption

Performance Index
This topic includes the following:

14 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 Introduction

� Device Interface Index


� Reliability Index

Device Interface Index


Syntax The following table provides the device interface indexes.

TABLE 7 INTERFACE INDEX

Interface Regulation

ITU-T K.41 Resistibility of internal interface of telecom-


munication centers to surge overvoltages

ITU-T K.20 Resistibility of telecommunication switching


equipment to overvoltages and overcurrents

POTS ITU-T K.30 Positive Temperature Coefficient (PTC)

YDN065—1997 Telephone switching equipment general


specification of MPT

YD/T751—95 PSTN office digital telephone switching


equipment testing method

YDN 065—1997 Telephone switching equipment general


specification of MPT
ISDN
YDN034-1997 ISDN user network interface specifica-
tions

2/4 audio
ITU-T G.712
line

SHDSL in-
ITU-T G.991.2
terface

ITU-T G.992.1 G.dmt ITU-T G.992.2 G.lite TU-T


ADSL inter-
G.992.3 TU-T G.992.4 TU-T G.992.5 ANSI American Na-
face
tional

E1 interface ITU-T G.703 ITU-T G.704

ATM inter-
ITU-T G.707 SDH-frame
face

Ethernet in- IEEE 802.3iIEEE 802.3xIEEE 802.3uIEEE 802.3zIEEE Std


terface 802.3abIEEE 802.1QIEEE 802.3ah

IMA inter-
AF-PHY-0086.000AF-PHY-0086.001
face

ITU-T G.707 SDH-frame ITU-T G.958 Automatic Laser


STM-1 Shutdown ITU-T G.783 RSOH+MSOH handling ITU-T
I.432.1

Confidential and Proprietary Information of ZTE CORPORATION 15


ZXMSG 5200 Hardware Installation Manual (OUT50M)

Reliability Index
Syntax The reliability index is listed as follows:
� System cold start time: ≤3.5 minutes
� Annual faulty time: ≤5.3 minutes
� System usability: ≥ 99.999%
� System MTBF: 69000 hours

16 Confidential and Proprietary Information of ZTE CORPORATION