The Design Is Adequate
The Design Is Adequate
CLIENT : DESIGN BY :
JOB NO. : DATE : REVIEW BY :
Column Deformation Compatibility Design using Finite Element Method
ANALYSIS
DETERMINE JOINT DEFLECTIONS AND SECTION FORCES
Fy = 50 ksi E = 29000 ksi G= 11154 ksi
A= 17.6 in2 I= 341 in4
JOINT DEFLECTIONS UNDER D ONLY THE DESIGN COLUMN SECTION FORCES UNDER D ONLY
Note X (in) Y (in) q (deg) Note V (k) P (k) M (ft-k)
N1 0 0 0.496192 N2 -33.09 0.000 225.24
N2 0 0.0000 -1.007175 N3 33.09 0.000 238.00
N3 4.2 0.0000 -0.932621
N4 4.2 0.0000 0.457379
P r 8 M rx M ry P r 0.2
, for
c
P 9 M M P 1.00 < 1.0 [Satisfactory]
cx cy c
Pr M ry
M rx , for P r 0.2
2 P M cx M cy Pc
c
Where KLx = 14 ft, for x-x axial load. KLy = 14 ft, for y-y axial load.
(KL / r)max = 65 < 200 [Satisfactory]
Pr = 42.00 kips
Mrx = 251.30 ft-kips
Mry = 0.00
Pc = f P n = 0.9 x 643.43 = 579.09 kips, (AISC 360 Chapter E)
> Pr [Satisfactory]
Mcx = f Mn = 0.9 x 289.99 = 260.99 ft-kips, (AISC 360 Chapter F)
> Mrx [Satisfactory]
Mcy = f Mn = 0.9 x 145.833 72.92 ft-kips, (AISC 360 Chapter F)
> Mry [Satisfactory]
Note: The governing case is always that only the design story column has Story Drift and other stories no drift, since the other
story at same direction drifts, including PD effects, will reduce the section forces of design story column. The opposite story
drifts are not Expected Deformation, because Expected Deformation can not be developed from Linear Modes Analysis
after CQC or SRSS.
PROJECT : PAGE :
CLIENT : DESIGN BY :
JOB NO. : DATE : REVIEW BY :
Tube / Pipe Column Design Based on AISC Manual 13th Edition (AISC 360-05)
STRONG AXIS BENDING ? (1=Yes, 0=No) => 1 yes, strong axis, x-x, bending.
UNIFORM LATERAL LOAD, ASD w= k / ft
CONCENTRATED LATERAL LOAD, ASD F= kips at ft from bottom
ANALYSIS
CHECK COMBINED COMPRESSION AND BENDING CAPACITY (AISC 360-05, H1)
P r 8 M rx M ry Pr
, for 0.2
P c 9 M cx M cy Pc
0.00 < 1.0 [Satisfactory]
P r M rx M ry P r 0.2
, for
2 P M M Pc
c cx cy
Where KLx = 14 ft, for x-x axial load. KLy = 14 ft, for y-y axial load.
(KL / r)max = 36 < 200 [Satisfactory]
Pr = 0 kips
Mrx = 0.00
Mry = 0.00
Pc = P n / W c = 881 / 1.67 = 527.812 kips, (AISC 360-05 Chapter E)
> Pr [Satisfactory]
Mcx = Mn / Wb = 343.467 / 1.67 = 205.669 ft-kips, (AISC 360-05 Chapter F)
> Mrx [Satisfactory]
Mcy = Mn / Wb = 343.467 / 1.67 = 205.669 ft-kips, (AISC 360-05 Chapter F)
> Mry [Satisfactory]
STRONG AXIS BENDING ? (1=Yes, 0=No) => 1 yes, strong axis, x-x, bending.
UNIFORM LATERAL LOAD, ASD w= k / ft
CONCENTRATED LATERAL LOAD, ASD F= kips at ft from bottom
ANALYSIS
CHECK COMBINED COMPRESSION AND BENDING CAPACITY (AISC 360-05, H1)
P r 8 M rx M ry P r 0.2
, for
c
P 9 M
cx M cy P c
0.00 < 1.0 [Satisfactory]
P r M rx M ry
, for P r 0.2
2 P M cx M cy Pc
c
Where KLx = 14 ft, for x-x axial load. KLy = 14 ft, for y-y axial load.
(KL / r)max = 65 < 200 [Satisfactory]
Pr = 0 kips
Mrx = 0.00
Mry = 0.00
Pc = Pn / W c = 643 / 1.67 = 385.288 kips, (AISC 360-05 Chapter E)
> Pr [Satisfactory]
Mcx = Mn / Wb = 289.986 / 1.67 = 173.644 ft-kips, (AISC 360-05 Chapter F)
> Mrx [Satisfactory]
Mcy = Mn / Wb = 145.833 / 1.67 = 87.3253 ft-kips, (AISC 360-05 Chapter F)
> Mry [Satisfactory]
ANALYSIS
CHECK LIMITING WIDTH-THICKNESS RATIOS FOR WEB (AISC 365-05 Table B4.1)
hc / tw = 21.05 < lr = 137.27
< lp = 90.55
Compact Web
where E= 29000 ksi
lr = 5.7 (E / Fy)0.5 = 137.27
lp = (hc / hp) (E / Fy)0.5 / (0.54 Mp / My -0.09)2 = 87.60 ,for Af,top ≠ Af,bot
lp = 3.76 (E / Fy)0.5 = 90.55 ,for Af,top = Af,bot
hc = 8.84 in hp = 9.20 in
Mp = 310.8 ft-kips My = 277.9 ft-kips
CHECK LIMITING WIDTH-THICKNESS RATIOS FOR FLANGES (AISC 365-05 Table B4.1)
0.5 bf,top / tf,top = 7.43 < lr = 25.09
< lp = 9.15
Compact Flanges
where lr = 1.0 (kc E / FL)0.5 = 25.09
lp = 0.38 (E / Fy)0.5 = 9.15
kc = Min [0.76 , Max (0.35 , 4 / (h / tw)0.5 )] = 0.76
Sxt = 67 in3 Sxc = 67 in3
FL = 35 ksi, (AISC 360-05 Table note B4.1 & Eq F4-6)
DETERMINE CRITERIA FOR ALLOWABLE FLEXURAL STRENGTH (AISC 365-05 Table F1.1)
Chapter F Sections
Required Conditions F2 F3 F4 F5
Double Symmetric x x
Compact Web x x x
Noncompact Web
Slender Web Mallowable = Mn / W b = 173.6 ft-kips
Compact Flanges x ( from following analysis)
Noncompact Flanges
Slender Flanges
Applicable Section ok
E 9.07 ft
L p 1.76r y
Fy
2
E Jc 0.7 F y S x h 0 E
L r 1.95r ts 1 1 6.76
E r ts 36.58 ft
0.7 F y S x h0 Jc 0.7 Fy
where ry = 2.57 in Sx = 67 in3
h0 = 9.52 in Iy = 116 in4
(cont'd)
Cw = Iy h02 / 4 = 2628.28 , (AISC 365-05 F2.2)
J = [tw d (tw2 + d2)] / 12 = 37.2053 in4, (not applicable if taken web only, EIT Manual page 26)
(Use J= 2.48 in4 )
rts =[( Iy Cw)0.5/ Sx)]0.5 = 2.88 in
c= 1.0 Cb = 1.0 , (AISC Manual 13th Table 3-1, page 3-10)
2
C b 2E Jc L b
F cr 2
1 0.078 119.864 ksi
Lb S x h 0 r ts
r ts
M p , for L b L p
Lb L p
M n, F 2 Min C b M p M p 0.7 F y S x
, M p , for L p L b L r
290.0 ft-kips
L
r L p
Min F S
cr x , M p , for L r L b
pf
M p M p 0.7 F y S x , for Noncompact Flanges
rf pf
M n, F 3 323.4 ft-kips
0.9 E k c S x
, for Slender Flanges
2
where l = bf / (2 tf) = 7.43
lpf = lp = 9.15 lrf = lr = 25.09
E 6.42 ft
L p 1.1r t
Fy
2
E J S h
L r 1.95r t 1 1 6.76 F L xc 0 36.96 ft
FL S xc h 0 E J
Mp
, for h c / t w pw
M yc
R pc 1.11844
Min M p M p 1 pw , M p , for h c / t w pw
M yc M yc rw pw M yc
2
C b 2E 1 0.078 J L b
F cr 2 121.731 ksi, (for Iyc / Iy = 0.50 > 0.23, AISC 360-05 F4-5 )
Lb S xc h 0 r t
rt
R pc M yc , for L b L p
Lb L p
M n, F 4.2 Min C b R pc M yc R pc M yc F L S xc , R pc M yc , for L p L b L r
281.9633 ft-kips
L r L p
Min F S
cr xc , R pc M yc , for L r L b
(cont'd)
R pc M yc , for Compact Flanges
pf
R pc M yc R pc M yc F L S xc , for Noncompact Flanges
M n, F 5.3 rf pf 310.833 ft-kips
0.9 E k c S xc
, for Slender Flanges
2
M p
, for h c / t w pw
M yt
R pt 1.11844
Min M p M p 1 pw , M
p
for h c / t w pw
,
M yt M yt rw pw M yt
F y , for L b L p
L b L p
Min C b F y 0.3F y
, F y ,
for L p L b L r
L r L p
F cr , F 5.2 42.6577 ksi
C b 2E
Min 2
, F y , for L r L b
Lb
r
t
Section Left 0.00 S 0.00 S 0.00 S 0.00 S 0.00 S Point 0.17 S 0.33 S 0.50 S 0.67 S 0.83 S Right
Distance 0 0.00 0.00 0.00 0.00 0.00 0.00 2.33 4.67 7.00 9.33 11.67 14.00
d (in) 10 10 10 10 10 10 10 10 10 10 10 10 10
y (in) 5 5 5 5 5 5 5 5 5 5 5 5 5
I (in4) 336 336 336 336 336 336 336 336 336 336 336 336 336
Wt (plf) 59.4 59.4 59.4 59.4 59.4 59.4 59.4 59.4 59.4 59.4 59.4 59.4 59.4
V (kips) 0.42 0.42 0.42 0.42 0.42 0.42 0.00 -0.28 -0.14 0.00 0.14 0.28 0.42
M (ft-k) 0 0 0 0 0 0 0 1 1 1 1 1 0
(cont'd)
Moments
0
-50
-100
-150
-200
Length
-75.50
-76.00
-76.50
-77.00
-77.50
Length
5w L 4 0.06415 Pb
L 2 b 2
3/ 2
DL 0.01 in ( L / 31891 )
384 EI EIL (for camber, self Wt included.)
5w L 4 0.06415 Pb
L 2 b 2
3/ 2
LL 0.00 #DIV/0!
384 EI EIL
w= 1/4 in
wmin = 3/16 in, < w
wmax = 5/16 in, > w
W= 2.0
Vmax = 0.42 kips
Q = Af(d - y - 0.5 tf,top) = 33 in3
vmax = Vmax Q / I = 0.04 kips / in
A= 24 in B
0.6 F EXX 0.707 w A 2202 in. o.c.
v max
USE 1/4 in - 24 in @ 2202 in o.c.
DESIGN STIFFENERS
1. BEARING STIFFENERS ARE REQUIRED AT EACH END SUPPORT. (AISC 360-05, J10.8)
2. CHECK LOCAL WEB YIELDING FOR THE CONCENTRATED LOAD. (AISC 360-05, J10.2)
R=P= 0.00 kips
N= 0 in, bearing length, point.
k = tf,top + w = 0.93 in
W= 1.5
R
, for c d
t w N 5k
0.00 < Fy / W [Satisfactory]
R
, for c d
t w N 2.5 k
(cont'd)
3. CHECK WEB CRIPPLING FOR THE CONCENTRATED LOAD. (AISC 360-05, J10.3)
W= 2.0
1.5
2 N t w EF ywt f , for c 0.5 d
0.80t w13 d
t f tw
Rn / 1 / 108.11 > P [Satisfactory]
1.5
0.40t 2w13 N t w EF ywt f , for c 0.5 d
d t f tw
(Note : If item 2, local web yielding is Satisfactory, this item does not need to be checked.)
4. CHECK SIDESWAY WEB BUCKING FOR THE CONCENTRATED LOAD. (AISC 360-05, J10.4)
dc = d - 2k = 8.34 in
Cr = 960000 ksi
(dc / tw ) / (l / bf) = 1.19
W= 1.76
3
C r t wt f 0.4 d c / t w , for d c / t w 1.7
3
h 2 l / b f l/b f
C r t 3wt f
3
Rn / 1 / 10.4 d c / t w , for 1.7 d c / t w 2.3 239.31 > P [Satisfactory]
h
2 l /b f l /b f
dc /tw
P , for l / 2.3
bf
(Note : If item 2, local web yielding is Satisfactory, this item does not need to be checked.)
tw = 1/3 in , bst = 4 in
R= 0.4 kips
Wc = 1.67 , (AISC 365-05 E1)
Kl/r= 0.75 h / ( I / Aeff)0.5 = 3.6
Cc = 4.71 (E/ Fy)0.5 = 113
2E 21968.64 ksi
Fe
kl / r 2
Fy kl
0.658 F e F y , for Cc
r
R n / c A g / c 138.1 kips, (AISC 360-05 E2)
kl
0.877 F e , for r Cc > R [Satisfactory]
Techincal Reference:
1. AISC: "Steel Construction Manual 13th Edition", American Institute of Steel Construction, 2005.