Conventional Fire Alarm Control Panel SFP 512: Product Features

The SFP 512 is a conventional fire alarm control panel that can monitor up to 12 fire detection zones. It has 4 onboard detection lines that can each monitor 32 detectors. The lines can be expanded to 12 total zones using optional expansion modules. The panel complies with European standards and has multilingual support. It provides relay outputs to control alarms and faults, and has an optional extinguishing control module. The compact modular design makes it suitable for small fire detection system installations.

Uploaded by

gradojica
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (1 vote)
673 views2 pages

Conventional Fire Alarm Control Panel SFP 512: Product Features

The SFP 512 is a conventional fire alarm control panel that can monitor up to 12 fire detection zones. It has 4 onboard detection lines that can each monitor 32 detectors. The lines can be expanded to 12 total zones using optional expansion modules. The panel complies with European standards and has multilingual support. It provides relay outputs to control alarms and faults, and has an optional extinguishing control module. The compact modular design makes it suitable for small fire detection system installations.

Uploaded by

gradojica
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Product information

Conventional Fire Alarm


Control Panel
SFP 512

Product features
• 4 Zones Conventional Fire Alarm Control Panel
• Expandable to max. 12 zones
• Complies with EN 54-2 and EN 54-4
• In different languages available
Extension modules
• 4 Zone Detection Module
• 1 Zone Extinguishing Module (EN 12094-1)
• 4 Relay Output Module (5A/230 V)

Description The SFP 512 fire alarm control panel is able to run
The SFP 512 is a microprocessor controlled
Securiton’s new conventional fire alarm control Securiton’s conventional detectors. Each line can
compact modular control unit for fire detection
panel SFP 512 is designed for small installations monitor up to 32 conventional detectors per line.
systems. Easy to use and to install, this panel
of fire detection systems. The SFP 512 fire alarm In case of fire alarm, the 1st and 2nd alarm can be
represents one of the best solutions
control panel complies with the EN 54-2, EN 54-4, distinguished within one detection zone and sepa-
to detect a fire in small installations.
and EN 12094-1 standards. rately indicated. The four relay output module can
The basic unit features four conventional detection be used to activate or deactivate power signals
lines and a full fire alarm control panel functional- with up to 230 V/5A.
ity. The detection zones are expanded to eight or The SFP 512 fire alarm control panel is available
twelve zones, by connecting one or two additional with different front panel operation languages. The
four-zone detection module to the basic SFP 512 technical documentation is included on a CD-ROM
unit. Alternatively, the SFP 512 can drive one extin- in various languages.
guishing zone with a maximum of eight detection
zones at the same time.

Architecture SFP 512

Line 1 SFP-4Z
(Optional)
Line 2
4 Zone
Line 3 Extension Module
Line 4
Fire Alarm
Line 1 SFP 512
Open Collector Output 1
Line 2 SFP-4R
Open Collector Output 2 (Optional)
Line 3 Open Collector Output 3
Basic Unit Relay Card
Line 4 (4 Zones) Open Collector Output 4

Relay Alarm Output


Programmable Input Relay Fault Output

Start SFP-EXT1 Extinguishing


(Optional)

Stop 1 Zone
Extinguishing Module
Evacuation
Low Pressure (Gas loss)
Technical data SFP 512
Dimensions SFP 512
Housing dimensions (W × H × D) 370 mm × 300 mm × 118 mm
Weight 2 kg (without batteries) 370 mm
Protection class IP 31
Ambient operating temperature –10 °C to +50 °C
Mains voltage and consumption 230 VAC , 50 – 60 Hz, < 75 W
Compliance EN 54-2 and EN 54-4

300 mm
Number of detector lines 4/8/12 Zona

Allarme
Guasto/Prova/
Fuori Servizio
Zona

Allarme
Guasto/
Prova/
In tensione

Allarme Incendio

Guasto

Fuori Servizio
Sirene

Guasto

Attive
Zona

Allarme
Guasto/
Prova/
Scarica in corso

Allarme

Evacuazione
Fuori Servizio Fuori Servizio Prova/Off
On/Off Scarica in corso

Number of detectors per line max. 32


F.S. F.S. Prova F.S.
On/Off On/Off On/Off On/Off
(Prova) (Prova) (Prova) On/Off Inibizione
Livello 2 Livello 2 Livello 2 Guasto sistema Livello 2 Livello 2

Guasto alimentazione Giorno/notte


Attiva Codifica Guasti
Accesso livelli 2 o 3
1 2 4
Zona Zona Zona

Allarme Allarme
A
-
B
+
On/Off
Allarme Modo Automatico Off

Relay outputs General alarm and fault,


Guasto/Prova/ Guasto/ Guasto/
Fuori Servizio Prova/ Prova Tacitazione Prova/ Modo Manuale Off
Fuori Servizio Led-buzzer buzzer Ripristino Fuori Servizio

F.S. F.S. F.S.


On/Off (Prova) On/Off (Prova) On/Off (Prova) On/Off On/Off
Livello 2 Livello 2 Livello 2 Livello 2 Livello 2 Livello 2

SFP - 4Z/I SFP 512/I SFP-EXT1/I

switch over contacts 1 A/30 VDC


Open collector outputs 4 outputs 100 mA/50 VDC
Output «24 VDC Supply» Power output protected with polyswitch,
24 VDC 400 mA
118 mm
Input 1 monitored input
Sounders line output 1 monitored output, 24 VDC, max. 450 mA
Maximum battery dimension 2 lead-acid batteries, 12 V/7.2 Ah
Colour Black RAL 7035
Technical data extinguishing module EXT-1
Type of actuator: Solenoid; Internal power supply 24 V per 30 s; Imax = 600 mA
External power supply 24 V per 30 s; Imax = 2 A
Type of actuator: Pyroelectric; Internal power supply 1 A per 2 s
External power supply 1 A per 2 s
Sounders line output 1 monitored output, 24 VDC, max. 450 mA
Compliance EN 12094-1
Technical data 4 relay module
Smoke Detector Heat Detector
Relay outputs 4 potential free, switch over contacts, 230 VAC /5A SSD 521 UTD 521
Product summary SFP 512
Fire alarm panel (without batteries) Part No.
SFP 512 I Small Fire Panel, 4 Zones, Italian Version, EN 54 VE610001
SFP 512 E Small Fire Panel, 4 Zones, English Version, EN 54 VE610002
SFP 512 S Small Fire Panel, 4 Zones, Spanish Version, EN 54 VE610003
SFP 512 P Small Fire Panel, 4 Zones, Portuguese Version, EN 54 VE610004
Extension modules 4 Zone Detection Module SFP-4Z
SFP-4R 4 Relay Output Module VE610021
SFP-4Z I Extension Board, 4 Zones, Italian Version VE610011
SFP-4Z E Extension Board, 4 Zones, English Version VE610012
SFP-4Z S Extension Board, 4 Zones, Spanish Version VE610013
SFP-4Z P Extension Board, 4 Zones, Portuguese Version VE610014
SFP-EXT1 I Extinguishing Zone Board, Italian Version VE610031
SFP-EXT1 E Extinguishing Zone Board, English Version VE610032
SFP-EXT1 S Extinguishing Zone Board, Spanish Version VE610033
SFP-EXT1 P Extinguishing Zone Board, Portuguese Version VE610034
Conventional detectors
SSD 521 Scattered Light Smoke Detector 5000545-0001
UTD 521 Universal Temperature Detector, Class A1 5100153-0001
UTD 521-2 Universal Temperature Detector, Class A2 5100153-0002
UTD 521-3 Universal Temperature Detector, Class B 5100153-0003
FT 513 Manual Call Point, red, IP 44, surface mount 6200072
Detector sockets (for all SSD and UTD detectors)
USB 501-1 Surface mounting socket 5000547-0001
USB 501-2 Socket for flush mounting in hollow or lowered ceilings 5000547-0002
USB 501-3 Mounting socket for humid areas 5000547-0003
USB 501-4 Socket for flush mounting in concrete ceilings 5000547-0004
Specifications subject to change without notice. Delivery subject to availability.

Securiton AG Representative Office Asia


Alarm- and Security Systems No 19A, Long Rahim Kajai 13
International Operations Taman Dr Ismail
4.2003

Alpenstrasse 20, CH-3052 Zollikofen/Bern MY-60 000 Kuala Lumpur


Tel. +41 31 910 11 22, Fax +41 31 911 25 32 Tel. +60 3 7725 1699, Fax +60 3 7725 1677
813842

www.securiton.ch, [email protected] [email protected]


A company of the Swiss Securitas Group

You might also like