PCB Checklist
PCB Checklist
______________________________________________________
1. Does the facility use or have in storage for reuse any PCB transformers
or PCB contaminated transformers? _____Yes _____No
_________________________________________________________________________
_________________________________________________________________________
761.30(a)(1)(i)
3. Are there any PCB transformers in use or in storage for reuse that pose
an exposure risk to food or feed? _____Yes _____No
If yes, describe:_________________________________________________
1
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
761.30(a)(1)(vi)(A)
4. Have all PCB transformers in use or in storage for reuse been registered
with the EPA by December 28, 1998? _____Yes _____No
(If yes to either of the above, obtain a copy of the registration form and
the return receipt signed by EPA. The facility must retain a copy of this
material as required by §761.30(a)(1)(vi))(C))
____________________________________________________________________________
2
____________________________________________________________________________
____________________________________________________________________________
____________________________________________________________________________
761.30(a)(1)(vii)
9. Were PCB transformers located in or near a commercial building
registered with the building(s) owner(s)? _____Yes _____No
_________________________________________________________________________
_________________________________________________________________________
761.30(a)(1)(xv)
11. For any transformer(s)located in or near commercial buildings assumed to
contain less than 500 ppm of PCBs that were tested and found to contain
500 ppm or greater of PCBs, did the facility initiate the following:
________________________________________________________________________
________________________________________________________________________
3
c. retrofill and reclassify or remove the above transformers within 18
months of discovery if enhanced electrical protection was not
provided?
_____Yes _____No _____N/A
12. List each building (name and address) and building owner with whom
registration occurred:
_________________________________________________________________________
_________________________________________________________________________
_________________________________________________________________________
_________________________________________________________________________
_________________________________________________________________________
________________________________________________________________________
________________________________________________________________________
761.30(a)(l)(vii)
14. Did registration with the building owner(s) include provision of the
following:
761.30(a)(l)(iii)
15. Has the facility installed any PCB transformers which were placed in
storage for reuse or which were moved from another location in or near
commercial buildings since October 1, 1985? _____Yes _____No
If yes, list locations and dates of installations and volume of each PCB
transformer installed:
4
_________________________________________________________________________
_________________________________________________________________________
_________________________________________________________________________
________________________________________________________________________
761.30(a)(1)(viii)
16. Are any combustible materials stored within:
If any are answered yes, take photographs and list the locations, type of
situation, type of combustibles and any relevant comments:
_____________________________________________________________________________
_____________________________________________________________________________
_____________________________________________________________________________
_____________________________________________________________________________
761.30(a)(l)(ix)
17. Are visual inspections of each in use or stored for reuse PCB
transformer for leaks performed at least once every three months since
August 1981? _____Yes _____No
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
761.30(a)(1)(xii)
5
18. Are inspection logs available? _____Yes _____No
If yes, obtain copies.
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
761.30(a)(l)(x)
19. Have arrangements been made to repair or replace leaking (i.e. PCB oil
running off or about to run off the external surface) PCB transformers?
_____N/A _____Yes _____No
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
761.30(a)(1)(x)
20. Was clean-up of released PCBs resulting from a leaking PCB transformer
initiated within 48 hours of its discovery? _____N/A _____Yes _____No
__________________________________________________________________
__________________________________________________________________
761.30(a)(1)(x)
6
21. Was an active leak of PCBs from a PCB transformer adequately contained
after its discovery? _____N/A _____Yes _____No
761.30(a)(1)(x)
22. Are daily inspections performed of actively leaking PCB transformers to
verify proper containment? _____N/A _____Yes _____No
761.30(a)(1)(xi)
23. Were any fire-related incidents involving a PCB transformer reported to
the National Response Center? _____N/A _____Yes _____No
761.30(a)(l)(xii)
24. Are inspection logs maintained for these daily inspections?
_____N/A _____Yes _____No
761.30(a)(1)(xii)
25. Are inspection and maintenance records maintained at least 3 years after
disposal of the PCB transformer? _____N/A _____Yes _____No
761.30(a)(1)(xii)
26. Do inspection/maintenance records include:
761.30(a)(l)(xiii)
27. If annual inspections are performed of in use or stored for reuse PCB
transformers:
7
Obtain dimensions.
761.30(a)(l)(xiv)
28. Were weekly inspections performed and records maintained at least 3
years where a PCB transformer in use or stored for reuse posed an
exposure risk to food or feed prior to October 1, 1985?
_____N/A _____Yes _____No
a. Dielectric fluid containing more than 500 ppm PCB was used?
_____N/A _____Yes _____No
If any are answered yes, obtain copies of appropriate records that are
available.
761.30(a)(2)(v)
30. If there was testing of a transformer(s) for reclassification
purposes, did such testing occur after a minimum of 3 months of in-
service use subsequent to last servicing and did temperature of
dielectric fluid reach 50o C or more?
_____N/A _____Yes _____No
761.40(a)
31. Are all PCB transformers in use or in storage for reuse properly
marked with a ML label? _____Yes _____No
8
________________________________________________________________________
________________________________________________________________________
________________________________________________________________________
761.40(j)
32. Are all vault/room doors, fences, hallways or other accessways to PCB
transformers properly marked with a ML label? _____Yes _____No
_________________________________________________________________________
_________________________________________________________________________
_________________________________________________________________________
_________________________________________________________________________
761.30(a)(l)(xv)
33. Does the facility have any mineral oil transformers assumed to contain
less than 500 ppm of PCBs that were tested and found to contain 500 ppm
or greater of PCBs? _____Yes _____No
b. Marked the vault door, machinery room door, fence, hallway or other
means of access to PCB transformers with a PCB ML label within seven
(7) days after discovery? _____Yes _____No
34. Does the facility use or have in storage for reuse any large PCB
capacitors? _____Yes _____No
9
b. Total number of PCB large low voltage capacitors in service: _______
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
761.2(a)(4)
36. Has the facility assumed that any capacitor manufactured prior to July 2,
1979 or any capacitor whose date of manufacture is unknown and whose PCB
concentration is not established contains 500 ppm PCB?
_____Yes _____No _____N/A
761.30(l)(1)(i)
37. After October 1, 1988, did the facility have any PCB Large High or Low
Voltage Capacitors in use or in storage for reuse that pose an exposure
risk to food or feed? _____Yes _____No
761.30(l)(1)(ii)
38. After October 1, 1988, did the facility have any PCB Large High or Low
Voltage Capacitors in use in an area other than a restricted-access
electrical substation or a contained and restricted-access indoor
installation? _____Yes _____No
761.40(c)(2)(ii)
39. Are all PCB large high voltage capacitors individually marked with
an ML label unless they are installed in a protected location such
as on a power pole, a structure, or behind a fence, in which case
the pole, structure or fence must be properly labelled?
_____Yes _____No
10
If no, describe circumstances:
_________________________________________________________________________
_________________________________________________________________________
_________________________________________________________________________
_________________________________________________________________________
761.40(k)(1)
40. Are all PCB large low voltage capacitors individually marked with an ML
mark unless they are installed in a protected location such as on a
power pole, structure, or behind a fence, in which case the pole
structure or fence is labelled by April 26, 1999?
_____N/A _____Yes _____No
761.40(k)(2)
41. Is all equipment containing a PCB large high or low voltage capacitor
labelled with an ML mark by April 26, 1999?
_____N/A _____Yes _____No
42. Does the facility use or have in storage for reuse any PCB voltage
regulators that contain three (3) lbs or more of dielectric fluid?
_____Yes _____No
761.40(l)(1)
43. Are all PCB voltage regulators individually marked with an ML label?
_____Yes _____No
761.40(l)(2)
44. Are locations of PCB voltage regulators such as vault doors, machinery
room doors, fences, hallways or other means of access marked with an ML
label? _____Yes _____No _____N/A
761.30(h)(1)(ii)(B)
11
45. Are fire related incidents involving voltage regulators reported to the National Response
Center? _____Yes _____No _____N/A
761.30(h)(1)(ii)(C)
46. Are inspections of PCB voltage regulators performed in a fashion similar
to those required for PCB transformers (i.e., same frequency, scope, provisions when leaks occur,
documentation, etc.)? _____Yes _____No
761.30(h)(1)(ii)(D)
47. Does facility owning PCB voltage regulators comply with the recordkeeping and reporting
requirements applicable to PCB transformers (§761.180)?
_____Yes _____No
48. Does the facility have any heat transfer or hydraulic systems?
_____Yes _____No
If yes, how many systems and what was the basis of determination:
_________________________________________________________________________
_________________________________________________________________________
_________________________________________________________________________
12
PCB CONTAMINATED POROUS SURFACES
50. Does the facility have a continued use of any PCB contaminated porous
surface (porous surface includes concrete, wood, and coated metal surfaces; contaminated
2
means >10 ug/100cm )? _____Yes _____No
761.30(p)(1)(i)
51. Was the source of PCB contamination removed or contained to prevent further release to
the porous surface(s) in use? _____Yes _____No
761.30(p)(1)(ii)
52. Was the surface(s) properly cleaned if accessible?
_____Yes _____No _____N/A
761.30(p)(1)(iii)
53. Was the surface(s) properly coated and marked with an ML label?
_____Yes _____No
Note: there are other authorized uses of PCB but they are not covered by this checklist
54. Does the facility store for reuse, in an area not meeting the
requirements of §761.65 (Storage for Disposal), any PCB Article?
_____Yes _____No
13
761.35(a)(1)
56. Has the facility complied with all use and marking requirements
applicable to the PCB Articles in storage for reuse (see questions above
pertaining to §761.30 and §761.40)? _____Yes _____No
761.35(a)(2)
57. Has the facility maintained records on its PCB Articles in storage for
reuse which indicate when they were removed from use, the projected
location and future use of the Articles and repair or servicing dates, if
applicable? _____Yes _____No
Pertinent Comments:
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
__________________________________________________________________
Transformer Observations
Table 1
14
_______________________________________________________________________________
_______________________
_______________________________________________________________________________
_______________________
_______________________________________________________________________________
_______________________
_______________________________________________________________________________
_______________________
_______________________________________________________________________________
_______________________
_______________________________________________________________________________
_______________________
_______________________________________________________________________________
_______________________
_______________________________________________________________________________
_______________________
_______________________________________________________________________________
_______________________
* Minor Leak - oil on outer surface but not about to run off
Moderate Leak - oil about to run off of outer surface
15
Major Leak - oil running off article onto surface below
Take photographs of leak and collect sample if PCB concentration is unknown
Capacitor Observations
Table 2
_______________________________________________________________________________
_______________________
_______________________________________________________________________________
_______________________
_______________________________________________________________________________
_______________________
_______________________________________________________________________________
_______________________
_______________________________________________________________________________
_______________________
_______________________________________________________________________________
_______________________
_______________________________________________________________________________
_______________________
16
_______________________________________________________________________________
_______________________
_______________________________________________________________________________
_______________________
_______________________________________________________________________________
_______________________
761.65(a)(1)
1. Were any PCB Articles, PCB Containers or other PCB items in storage for
disposal for more than one (1) year from the date in which the item was
removed from service for disposal? _____Yes _____No
761.65(a)(2)
If yes, did the facility obtain a one (1) year extension from EPA?
_____Yes _____No
761.65(b)(l)(i)
2. Does the storage facility have an adequate roof and walls to prevent rain
water from reaching the stored PCBs or PCB Items? _____Yes _____No
761.65(b)(l)(ii)
3. Does the storage facility have an adequate floor with continuous curbing
at least six inches high? _____Yes _____No
5. List below the internal volume of the largest PCB Article or Container in
the storage area (1) and the figure representing 25 percent of the total
internal volume of all the PCB Articles or Containers in the storage area
(2):
(1)____________________________
(2)____________________________
17
761.65(b)(1)(ii)
6. Does the floor and curbing provide a containment volume equal to at least
two times the internal volume of the largest PCB Article or Container
stored therein or 25 percent of the total internal volume of all the PCB
Articles or Containers stored therein, whichever is greater?
_____Yes _____No
761.65(b)(l)(iii)
7. Are there any drain valves, floor drains, sewer lines, or other openings
that would allow liquids to flow from the curbed storage area?
_____Yes _____No
__________________________________________________________________________
__________________________________________________________________________
_______________________________________________________________________
761.65(b)(l)(iv)
8. Are the storage area floor and curbing constructed of continuous smooth
and impervious materials, such as Portland cement, concrete or steel, to
prevent or minimize penetration of PCBs? _____Yes _____No
_________________________________________________________________________
_________________________________________________________________________
_________________________________________________________________________
761.65(b)(l)(v)
9. Is the storage area located at a site that is below the 100-year
flood water elevation? _____Yes _____No _____Unknown
If no, provide documentation that the storage area is above the 100-year
flood water elevation. If unknown, obtain as much information as possible
so that determination can be made in the Region.
761.65(c)(5)
18
10. Are PCB Articles and PCB Containers in storage for disposal checked
for leaks at least once every 30 days? _____Yes _____No
761.65(c)(5)
11. Are records available which document when inspections of the
storage facility are performed, by whom and the results of such
inspections? _____Yes _____No
12. Are there any leaking PCB Articles or PCB containers in storage
for disposal? _____Yes _____No
761.65(c)(5)
13. Have the contents of leaking PCB Articles or PCB Containers in
storage for disposal been transferred to properly marked
non-leaking containers? _____N/A _____Yes _____No
_________________________________________________________________________
_________________________________________________________________________
_________________________________________________________________________
761.65(c)(5)
14. Have spilled or leaked materials from PCB Articles or PCB
Containers in storage for disposal been immediately cleaned up
using absorbents or other adequate means?
_____N/A _____Yes _____No
_________________________________________________________________________
_________________________________________________________________________
_________________________________________________________________________
_________________________________________________________________________
761.65(c)(6)
19
15. Are all containers used for the storage of liquid or non-liquid PCB
waste in accordance with DOT regulations (49 CFR §171-180)?
_____N/A _____Yes _____No
761.65(c)(7)(ii)
16. Has an SPCC plan been prepared and implemented in cases where PCB
liquids are stored in containers (incl. tanks) that are larger than
those specified in the DOT regulations (i.e. 55 gal drums)?
_____N/A _____Yes _____No
761.65(c)(8)
17. Are PCB Articles and PCB Containers dated as to when they were
placed in storage? _____Yes _____No
761.65(c)(8)
18. Is storage managed so that the PCB Articles and PCB Containers can
be located by the date they entered storage? _____Yes _____No
761.65(c)(8)
19. Are records available which indicate the date and quantity of each
batch of PCBs either added to or removed from large (> 55 gallon)
containers in storage? _____N/A _____Yes _____No
20. Does the facility store any bulk PCB remediation waste or PCB bulk
product waste at the clean-up site or site of generation?
_____Yes _____No
761.65(c)(9)
a. Has the waste been stored for 180 days or less?
_____Yes _____No
761.40(a)(10)
20
21. Is each storage area and the PCB Items stored therein for disposal
properly marked with a ML label? _____Yes _____No
_________________________________________________________________________
_________________________________________________________________________
_________________________________________________________________________
_________________________________________________________________________
22. Does the facility utilize a temporary storage area for PCB Items?
_____Yes _____No
If yes, list types of PCB Items in temporary storage and answer the
following questions:
_________________________________________________________________________
_________________________________________________________________________
_________________________________________________________________________
_________________________________________________________________________
761.65(c)(l)
23. Have any PCB Items been in temporary storage in excess of 30 days?
_____Yes _____No
______________________________________________________________________
761.65(c)(1)
24. Is there a notation on PCB Items in temporary storage indicating
when the item was removed from service? _____Yes _____No
761.65(c)(l)(ii)
25. Are there any leaking PCB Articles or PCB Equipment in temporary
storage which have not been placed in a non-leaking container that
contains a sufficient amount of sorbent material?
_____Yes _____No
21
761.65(c)(l)(iv)
26. Has an SPCC plan been prepared for a temporary storage area where
PCB Containers containing liquid PCBs at a concentration 50ppm are
being stored? _____N/A _____Yes _____No
761.65(c)(1)(iv)
27. Are PCB containers containing liquid PCBs at a concentration
50 ppm in temporary storage authorized by DOT regulations (49 CFR
§171-180)? _____N/A _____Yes _____No
761.65(c)(3)
28. Is the temporary storage area properly marked with an ML label?
_____Yes _____No
29. Does the facility store any PCB items on pallets next to a
designated storage area? _____Yes _____No
_________________________________________________________________________
_________________________________________________________________________
_________________________________________________________________________
_________________________________________________________________________
_________________________________________________________________________
761.65(c)(2)
30. Does the storage facility have immediately available unfilled
storage equal to 10 percent of the volume of PCB large, high voltage
capacitors and PCB contaminated electrical equipment stored outside the
facility? _____Yes _____No
761.65(c)(2)
31. Are the capacitors or other electrical equipment stored outside the
facility checked for leaks at least weekly? _____Yes _____No
32. Is the facility a commercial storage facility (i.e., accepts PCB wastes
from other facilities)? _____Yes _____No
22
If yes, answer the following:
If yes, obtain evidence, including proof that it has met financial responsibility requirements and
has an acceptable closure plan.
Pertinent Comments:________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
23
PCB ITEMS IN STORAGE FOR DISPOSAL ( 50 ppm)
Table 3
24
ITEM ITEM RECORD PCB ML ITEM REMARKS
DESCRIPTION DATED? DATE LABEL? LEAKING?
(Y) (N) (Y) (N) (Y) (N)
1. Is the facility a commercial facility (i.e., accepts PCB wastes from other facilities)?
_____Yes _____No
761.1(a)(5)
25
4. Does it appear as though the facility is diluting any of its PCB waste prior to disposal?
_____Yes _____No _____N/A
5. Check which of the following types of PCB waste the facility handles
(state whether waste is cleaned up/decontaminated, processed, or
disposed of):
___________________________________________________________
___________________________________________________________
___________________________________________________________
26
k. Other (describe) __________________________________________
*
- means waste containing PCB as a result of a spill, release, or
other unauthorized disposal. It includes bulk PCB remediation waste (i.e.,
soil, sediment, sludge), non-porous surfaces, porous surfaces, and
liquids
**
- means waste derived from manufactured products containing PCBs in a non-
liquid state. It includes demolition debris, material from shredding operations
(i.e., fluff), coatings, insulation and fluorescent light ballasts containing PCB
contaminated potting material
If yes, for each specific type of PCB remediation waste, describe its PCB concentration, the
clean-up procedure employed and the level of clean-up achieved (state if it’s self-
implementing).
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
27
7. Does the facility perform decontamination activities on any PCB waste materials, other
than PCB remediation waste, including water, organic liquids, non-porous surfaces (either
coated or uncoated) or concrete? _____Yes _____No
If yes, describe the PCB concentration of the waste, decontamination procedure employed and the
level of decontamination achieved (state if it’s self implementing).
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
8. For each PCB waste identified in question 5 as being disposed of at the facility,
indicate below its PCB concentration and the method and location of its disposal.
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
28
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
9. For any mixed media or multi-phase waste, does the facility use the media having the highest PCB
concentration to determine the appropriate method of disposal? _____Yes _____No
_____N/A
761.50(a)
10. Indicate below if any of the following disposal prohibitions were observed at the
facility?
761.60
11. Describe below any other disposal of PCB items that was not in accordance with the following
disposal matrix.
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
29
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
30
Large Undrained PCB X X (under
Capacitors certain
condi-
tions
PCB Remediation X X X
Waste - Liquid (<500
(not decontaminated) ppm)
PCB Remediation X X X
Waste - Non-Liquid
(not decontaminated)
Non-Liquid PCB- X X X X X
Bulk Product Waste
Non-Liquid PCB- X X
Soil, Rags, Debris
Non-Liquid PCB- X X X
Sludges, Sediment
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
31
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
32
IV. RECORDKEEPING AND REPORTS RELATED TO USE, STORAGE AND DISPOSAL
OF PCB
Note: If the facility is a disposer or commercial storer of PCB waste skip to question 12
761.180(a)
1. Does the facility have in use, or in storage for future use or disposal, the
following:
761.180(a)
2. Has the facility developed and maintained all annual records and the annual document
log as of July 1, 1991, and each year thereafter? ______Yes ______No
a. Are the annual records and the annual document log prepared on a calendar year
basis? ______Yes ______No
33
b. Has the facility retained the annual records and the annual document logs
for at least three (3) years after it no longer used or stored PCBs or PCB Items?
______Yes ______No
______________________________________________________________________
_________________________________________________________________
_________________________________________________________________
34
a. The name, address, and EPA identification number of the facility?
______Yes ______No
761.180(a)(2)(ii)(A)
b. The first date it was removed from service for disposal? ______Yes
______No
761.180(a)(2)(ii)(B)
a. The serial number (if available) or other means of identifying each PCB
Article? ______Yes ______No
35
b. The weight in kilograms of the PCB waste in each PCB Article? ______Yes
______No
761.180(a)(2)(ii)(C)
d. The first date material was placed in each PCB Container? ______Yes
______No
e. The date each container was placed in transport for off-site storage or
disposal? ______Yes ______No
761.180(a)(2)(ii)(D)
36
PCB Article Containers _____N/A
c. The total weight in kilograms of the contents of each PCB Article Container?
______Yes ______No
d. The first date a PCB Article was placed into each container? ______Yes
______No
e. The date the container was placed in transport for off-site storage or
disposal? ______Yes ______No
761.180(a)(2)(iii)
7. Does the facility's annual document log contain the total numbers and total weights
(kg.) for the following items:
37
______Yes ______No _____N/A
g. Total weight of bulk PCB waste that was placed into storage for disposal or
disposed during the calendar year? ______Yes ______No
_____N/A
d. Total weight (kg) of PCBs and PCB Items in PCB Containers? ______Yes
______No _____N/A
761.180(a)(2)(vii)
38
9. For any PCBs or PCB Items received from or shipped to another facility owned or operated
by the same generator, does the annual document log contain the same information as asked in
Question No. 6?
______Yes ______No _____N/A
761.180(a)(2)(viii)
10. Does the facility's annual document log contain a record of each telephone call (or
other means of verification) made to each commercial storer or disposer to confirm
receipt of PCB waste transported by an independent transporter?
______Yes ______No _____N/A
761.180(a)(2)(ix)
11. Does the facility’s annual document log contain the name, address and telephone number
of the person to whom a PCB item containing >50ppm PCB, excluding small capacitors, has
been distributed in commerce for reuse along with date of transfer and the serial or internal
identification number of the item? _____Yes _____No _____N/A
12. Has the facility developed and maintained all annual records and the annual document
log as of July 1, 1991, and each year thereafter? ______Yes ______No
a. Are the annual records and the annual document log prepared on a
calendar year basis? ______Yes ______No
b. Has the facility retained the annual records and the annual document logs
for at least three (3) years after it no longer used or stored PCBs or PCB Items?
______Yes ______No
39
c. Has the facility prepared and submitted to the EPA Regional
Administrator annual reports by July 15th for each preceding calendar year?
______Yes ______No
____________________________________________________________
_______________________________________________________
_______________________________________________________
40
______Yes ______No
761.180(b)(2)(ii)(A)
16. Does the written annual document log contain the following
information from each manifest and for unmanifested waste that may be stored or disposed of
at the facility:
761.180(b)(2)(ii)(B)
a. The serial number (if available) or other means of identifying each PCB Article
(not in a PCB Container or PCB Article Container)?
______Yes ______No
41
b. The weight in kilograms of the PCB waste in each PCB Article? ______Yes
______No
761.180(b)(2)(ii)(C)
d. The first date material (PCB Waste) placed in each PCB Container was removed
from service for disposal? ______Yes ______No
42
g. The date of disposal, if known? ______Yes ______No
761.180(b)(2)(ii)(D)
c. The total weight in kilograms of the contents (PCB Waste)of each PCB Article
Container? ______Yes ______No
d. The first date a PCB Article placed into each container was removed from
service for disposal? ______Yes ______No
f. The date the container was placed in transport for off-site storage or disposal?
______Yes ______No
17. Does the facility use EPA's "PCB VOLUNTARY FORM FOR THE ANNUAL REPORT" to document the
annual report? ______Yes ______No
43
761.180(b)(3)(i) & (ii)
18. Does the facility's annual report contain the following information:
a. The name, address, and EPA identification number of the facility? ______Yes
______No
e. Remaining in storage for disposal at the facility at the end of the calendar
year? ______Yes ______No
(Refer to EPA's "PCB Voluntary Form For The Annual Report" as a guide to answering this question)
44
Pertinent Comments
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
45
SUBPART K - PCB WASTE DISPOSAL RECORDS AND REPORTS
(40 CFR Part 761.202-761.218)
761.205(c)(2)
20. Is the facility exempt from the EPA notification requirements because it is only a generator
of PCB waste through its use, owning, servicing or processing of PCBs or PCB items but does
not own or operate a designated storage for disposal area subject to the requirements of
§761.65(b) or §761.65(c)(7)? _____Yes _____No
761.202(c)
21. Has the facility engaged in PCB waste handling activities on or prior to February 5, 1990?
_____Yes _____No
761.202
22. Has the facility applied for an EPA identification number?
_____Yes _____No
46
If yes, what was the date of the application and has the ID number been officially issued?
____________________________________________________________________________
____________________________________________________________________________
____________________________________________________________________________
761.205(b)
If the facility has a RCRA ID number, did it notify EPA of its PCB waste activities by April 4, 1990?
_____Yes _____No
761.205(c)(2)(iii)
23. Has the generator submitted separate notifications to EPA for each PCB storage area it
owns or operates on different sites or properties? _____Yes _____No _____N/A
761.205(f)
24. Has the facility resubmitted a notification form within 30 days from the time that its waste
handling activities changed?
_____Yes _____No _____N/A
25. If the facility did not engage in PCB waste activities until after February 5, 1990
and has not yet received an EPA identification number or if the facility engaged in PCB waste
activities on or before February 5, 1990 but has not applied for an EPA identification number
have any of the following occurred:
761.202(b)(c)&(d)
47
a. The facility is a generator of PCB waste and processed, stored, transported or
offered for transport or disposed of such PCB waste after June 4, 1990? _____Yes
_____No
761.202(b)(c)&(d)
b. The facility is not a generator of PCB waste but has engaged in transporting,
commercial storage or disposal of such PCB waste after June 4, 1990? _____Yes _____No
761.202(b)(c)&)d)
c. The facility is a generator that offered PCB waste to transporters, commercial
storers, or disposers who have not received an EPA identification number? _____Yes
_____No
761.202(b)(c)&(d)
d. The facility is not a generator of PCB waste but has delivered such waste to a
transporter, commercial storer or a disposer that have not received an EPA identification
number? _____Yes _____No
761.207(a)
26. Has the generator prepared a manifest whenever it ships PCB waste, including drained
PCB contaminated transformers off-site?
_____Yes _____No _____N/A
761.207(a)
27. Was the manifest prepared on EPA Form 8700-22 with a continuation sheet if necessary?
_____Yes _____No
____________________________________________________________________________
48
____________________________________________________________________________
761.207(a)(1)
a. For each bulk load of PCBs, its identification, the earliest date of removal from
service for disposal and its weight in kilograms?
_____Yes _____No _____N/A
761.207(a)(2)
b. For each PCB container or article container, an identification number, type of PCB
waste, earliest date of removal from service for disposal and its weight in kilograms?
_____Yes _____No _____N/A
761.207(a)(3)
c. For each PCB article, its serial number or other identification, date of removal from
service for disposal and weight in kilograms of its PCB waste? _____Yes _____No
_____N/A
761.207(g)
d. An approved off-site commercial storage or disposal facility for PCB waste? _____Yes
_____No
761.209(a)
29. Did the generator of PCB waste, transporter or the storage or disposal facility retain on
file copies of the appropriate manifests?
_____Yes _____No
761.209(a)
30. Were the manifests properly signed? _____yes _____no
761.208(a)(4)
49
31. Did the generator receive the hand signed manifest within 35 days after the PCB waste was
accepted by the transporter?
_____Yes _____No _____N/A
761.208(a)(4)
If yes, did the generator confirm by telephone or other means (if shipped by an independent
transporter) within a day after receiving the hand-signed manifest that the commercial storer or
disposer actually received the manifested waste? _____Yes _____No _____N/A
761.208(a)(4)
If no, did the generator telephone or communicate by other means first with the commercial storer or
disposer and then, if necessary, with the transporter to determine the status of the PCB waste?
_____Yes _____No _____N/A
761.208(a)(4)
32. If the generator has not received a hand-signed manifest from an EPA approved facility
within 10 days from the date of the telephone call to the transporter, did it submit an
exception report to the EPA Regional Administrator? _____Yes _____No _____N/A
761.211(a)
33. Is there evidence to indicate that either a transporter or a commercial storer or disposer
accepted a shipment of PCB waste after April 4, 1990 without a properly signed manifest?
_____Yes _____No _____N/A
761.211(c)
If yes, describe and state whether an "Unmanifested Waste Report"
was submitted to the EPA Regional Administrator within 15 days after the unmanifested PCB waste was
received.
____________________________________________________________________________
____________________________________________________________________________
50
____________________________________________________________________________
____________________________________________________________________________
761.210(a)
34. Is there evidence to indicate that a significant discrepancy regarding the amount of PCB
waste stated on the manifest occurred?
_____Yes _____No _____N/A
761.210(b)
If yes, describe the discrepancy and attempts to reconcile it, and state whether a letter was
submitted to the EPA Regional Administrator if it is was not resolved within 15 days after the PCB
waste was received
____________________________________________________________________________
____________________________________________________________________________
____________________________________________________________________________
____________________________________________________________________________
____________________________________________________________________________
Answer questions 35 and 36 if
the facility is a disposer of PCB waste
761.215(c)(1)&(2)
35. Does the disposer submit to the EPA Regional Administer, no later than 45 days from the
end of the one (1) year storage for disposal date a One-year Exception Report if it receives
PCB or PCB items more than 9 months after they were removed from service for disposal and, it
51
could not dispose of the affected PCBs or PCB items within 1 year of the date of
removal from service for disposal? _____Yes _____No
761.218(a)&(b)
36. Does the disposer prepare a Certificate of Disposal for each shipment of PCB waste that it
accepts and does it send a copy to the generator identified on the manifest within 30 days
of the date that disposal of the PCB waste was completed? _____Yes _____No
761.215(d)(1)&(2)
37. Does the generator or commercial storer submit to the EPA Regional Administrator, no
later than 45 days, a One-year Exception Report if it transferred PCB or PCB items to the
disposer within 9 months after they were removed from service for disposal and it either has
not received, within 13 months after removal from service for disposal, a Certificate
of Disposal confirming the disposal of the affected PCBs or PCB items or it receives a
Certificate of Disposal confirming disposal more than 1 year after the date of removal from
service? _____Yes _____No
Pertinent Comments
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
52
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
53
Addendum to PCB Checklist
The following items are not addressed in the checklists but, if the situation warrants, they should be
addressed in the inspection report.
761.20(a)
1. Were any PCBs being used in other than a totally enclosed manner?
761.20(b)
2. Were PCBs being manufactured without an exception?
761.20(c)
3. Were PCBs being processed or distributed in commerce without an exception?
4. Does the facility have any waste oil? If so, collect a sample of it for PCB analysis. Also,
determine whether any waste oil containing detectable concentrations of PCBs are being used as a
sealant, coating or dust control agent.
54
5. If the facility used PCBs in a hydraulic or heat transfer system, collect samples of sludges from
drainage systems near the hydraulic or heat transfer system.
6. If there were any spills or uncontrolled discharges of PCBs in excess of 50 ppm at the facility
were they cleaned up in accordance with spill cleanup policy contained in 40 CFR 761.125?
55