This document lists error codes and descriptions for the Encore 500 S and Encore 700 S dispensers. It includes over 100 error codes ranging from minor to supermajor issues covering things like communication failures, configuration errors, sensor errors, and more. The errors are organized by code number and include a description and severity level for each one.
Copyright
© © All Rights Reserved
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
1K views

Error CodesEnc

This document lists error codes and descriptions for the Encore 500 S and Encore 700 S dispensers. It includes over 100 error codes ranging from minor to supermajor issues covering things like communication failures, configuration errors, sensor errors, and more. The errors are organized by code number and include a description and severity level for each one.
Copyright
© © All Rights Reserved
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 7

Error Codes Encore 500 S, Encore 700 S

E1 W&M RAM Database Corrupted SUPERMAJOR

E2 Application RAM Database corrupted SUPERMAJOR

E3 LON Configuration Error SUPERMAJOR

E4 One or more tasks not started SUPERMAJOR

E5 Encore 500: Soft Coldstart by Jumper Encore CNG: Soft Coldstart with Manager Keypad (CC59,
FC1)

E6 NV Data Mismatch SUPERMAJOR

E7 Ecal Board Memory Error

E8 Database not compatible with previous version SUPERMAJOR

E9 Hardware Coldstart

E10 New Software Version detected and Security Switch not open

E12 Restore Calibration Factors from Door Node SUPERMAJOR

11 Two-Wire Communications break INFO

16 Preset Underrun

20 Pulser Disconnected / SIP Magnet Dropout

24 Volume Unit Type Not Set

25 Two-Wire/Standalone

26 Invalid Calibration Factor

27 Two-Wire ID Side A Changed MEDIUM

28 Two-Wire ID Side B Changed

29 “Valve Stuck” / Initital Dispenser or Maximum No Flow Timeout

30 VaporVac Catastrophic Error

31 DEF Freeze Warning

32 Maximum Authorize Time Expired Maximum Fill Time Expired

33 Stop Button Activated


35 Configuration Data Error

36 Unit type changed

37 Pin Code 1 Changed

38 Pin Code 2 Changed

40 Master Reset Jumper On

41 Side Exists Option Changed

42 Valve Not Open

44 Pump Handle on at Power Up

45 Minor Preset Overrun Error

46 Minimum Preset Limit MEDIUM

50 POS Communications Lost (Disconnected)

99 W&M Database CRC Incorrect

100 Application Flash Hash Invalid

4307 Blend Ratios Not Programmed

4308 No Blend Table

4311 Low Porduct Low Flow

4312 High Product Low Flow

4313 Low Product No Flow

4314 High Product No Flow

4315 High Product Contaminated by Low

4316 Low Product Contaminated by High

4320 Valve Configured for but Not Responding

4321 Valve Stuck

4322 Valve Board Not Connected

5037 Encore 500 Programming Entry Successful From Keypad Encore CNG: Totalizer corrupted
5038 Programming Entry Failure from Keypad

5039 Entry into Zmodem Serial Access Successful

5047 Pulser: Reverse Flow Detected

5049 Unauthorized Flow Detected

505 Pulser: Invalid Pulser/Pulser Pattern Invalid

5054 SIP Pulser Calibration Switch Open

5056 Security Switch On

5062 Date/Time Changed

5065 STP Board 1 Disconnected

5066 STP 1 Configured for but not detected

5067 STP 2 Configured for but not detected

5068 STP 3 Configured for but not detected

5069 STP 4 Configured for but not detected

5070 Vapor Recovery Option Enabled but Vapor Recovery Board Not Detected

5072 VaporVac Board Not Detected But Option Enabled

5074 Vapor Reccovery Motor Not Responding

5075 Two-Wire Communications Port Framing Error

5076 Two-Wire Communications Port Parity Error

5077 Two-Wire Communications Port Overrun Error

5078 Two-Wire Communication port UART error-Break error

5081 Air Sensor Not Connected But Option Enabled

5091 ATC Configured but No Communication to ATC Hub(s)

5092 ATC Node detected, but option not set

5098 ATC T-Meter Not Connected

5100 ATC Number of meters exeeds number of probes


5101 No Pulse Train Detected from T-Meters

5111 Display Board Communication Failure

5113 Display Board Not Preset

5115 Door Node Download Error

5116 Door Node NV Data Download Incomplete

5118 PPU Board Communication Failure

5120 PPU Board Pump Handle Not Connected Correctly

5121 PPU Grade Select Button Not Collected

5122 PPU Board Grade Select Button Stuck

5124 Density, Transaction or Preset Display Communications Failure

5130 Display Board Errors

5131 PPP Keypad Option Set but Not Present

5134 Density Display Communication Failure

5135 Preset Display Communication Failure

5136 Transaction Display Communication Failure

5137 Stop Button Not Detected but Option Enabled

5139 Stop Button Stuck

5140 Push to Start Not Detected But Option Enabled

5142 Push to Start Button Stuck

5174 Totalizer Node Communications Failure

5175 Totalizer Node Connected but Option Not Enabled

5183 Totalizer Present but No Return Pulse Detected

5230 Totalizer per Nozzle Corrupted

5239 Database Init Forced

5240 Database Read Failure


5241 Database Write Failure

5254 Real-Time Clock – Invalid Data Field

5300 PPU Value Changed

5378 Door Node Configuration Not Received by Customer Interface

5412 Customer Interface Configuration Error

5413 Zero Price on PPU

5414 PPU Type Mismatch/PPU Type Changed

5415 PPU Board Pump Handle Not Connected Correctly

5416 Display Type Changed While Dispenser Running

5535 Undefined Error

5600 Fuel Density not Set with VRC or ATC Enabled

5601 ATC Temperature Reading Out of Range

5602 Door Node Software Updated bu Security Switch Not On

5603 ATC Node Software Updated bu Security Switch Not On

5604 ATC Probe Short Circuit

5606 ATC Node Subscription Failure

5607 Door Node Subscription Failure

5608 Totalizer Node Subscription Failure

5612 Door Open

5613 Pump Node Udpate with Data from Door Node

5616 Pump and Door Node Match

5617 Door Closed

5801 CNG: Over Pressure Signal Detected

5802 CNG: External Shock Sensor Active

5804 CNG: No Flow Detected


5805 CNG: Pressure Too High

5806 CNG: Maximum Flow Rate Detected

5807 CNG: Maximum Mass Exceeded

5808 CNG: Calculated Delta Pressure Is Negative Value

5809 CNG: Maximum Pressure Limit Reached

5810 CNG: Temperature Out of Range

5811 CNG: Temperature Sensor Short Ciruit

5812 CNG: Temperature Sensor Disconnected

5813 CNG: Pressure Out of Range

5814 CNG: Pressure Sensor Short Circuit

5815 CNG: Pressure Sensor Disconne+B121cted

5816 CNG: CNG Board Communications Failure

6002 IS Hub 1 Disconncted

6003 IS Interface Disconnected

6042 Vapour Recovery Monitoring System Stop (Vaporix Stop)

6043 Vapor Recovery Alarm Side A

6044 Vapor Recovery Alarm Side B

6047 Vapour Recovery Board Dectected But Option Disabled

6048 Vapour Recovery Service Terminal Connected

6081 Exceeded Maximum Flow Rate

6088 SIP/IS Pulser: Communications Lost With Pulser Device

6089 SIP/IS Pulser: Pulser Enable State Error

6090 SIP/IS Pulser: Too Many Pulsers Enabled

6350 PPU Change Grade 1, Level 1

6351 PPU Change Grade 1, Level 2


6352 PPU Change Grade 2, Level 1

6353 PPU Change Grade 2, Level 2

6354 PPU Change Grade 2, Level 1

6355 PPU Change Grade 2, Level 2

6356 PPU Change Grade 2, Level 1

6357 PPU Change Grade 2, Level 2

6358 PPU Change Grade 2, Level 1

6359 PPU Change Grade 2, Level 2

6360 PPU Change Grade 2, Level 1

6361 PPU Change Grade 2, Level 2

8022 Encrypted Pulser: Encryption Failure on Enable

8025 Encrypted Pulser: Serial Number Mismatch MEDIUM

8040 Encrypted Pulser: Clock or Data Communication Interrupted

8041 Encrypted Pulser: Missing Data MAJOR

8042 Encrypted Pulser: Missing Clock MAJOR

8043 Encrypted Pulser: Missing Power MAJOR

8044 Encrypted Pulser: Invalid Data Packets (Checksum)

8045 Encrypted Pulser: Lift-off Detection MAJOR

8046 Encrypted Pulser: Tamper Event MAJOR

8047 Encrypted Pulser: Pulser Power Loss MAJOR

8048 Encrypted Pulser: Watchdog Event MAJOR

8049 Encrypted Pulser: Software Fault MAJOR

8050 Encrypted Pulser: Sensor Failure MAJOR

65535 Undefined Error