AnD Loadcells PDF
AnD Loadcells PDF
http://www.aandd.jp
Contents
Load Cell Terminology 3
Single Point 4
LCB03/04 Series 5
LCB05 Series 6
LC-4001 7
LC-4101 Series 8
LC-4102 Series 9
LC-4103 Series 10
LC-4204 Series 11
LCB22 Series 12
Beam Type 13
LCM13 Series 14
LCM13-M Series 15
LCM19 Series 16
LCM19-M Series 17
LC-4221 Series 18
LC-5206 Series 19
LC-5223 Series 20
LBP Series 21
Tension Type 22
LC-1205 Series 23
LC-1216 Series 24
LCS15 Series 25
Compression Type 26
LCC07 Series 27
LCC11/N Series 28
LCC12 Series 29
LC2224 Series 30
CP/TP Series 31
C2F1/C2Z1/C2X1 Series 32
CMX/CM Series 33
TM/UM Series 34
Flameproof Type 37
LCB01/02/06 Series 38
LCM17/LCM17-M Series 39
Weighing Platform 41
Equipment 42
Accessories 44
2
Load Cell Terminology
Each country has its own standard for the performance and quality of load cells.
In Japan, there is no standard stipulated uniquely for load cells, although JIS
(Load Cell - Test Method JIS B7602) and JMIF (Japan Measuring Instruments
Federation) prescribe methods for performance tests.
Meanwhile, the OIML (International Organization of Legal Metrology) sets the
international recommendation titled “Metrological Regulation for Load Cells,”
with which each member country tries to make their local regulation consistent.
The terms described below are commonly used by the OIML and its member
countries.
Zero balance
The electrical output when the rated excitation voltage is applied without any load
on the cell. Generally expressed as a percentage of rated output.
Input terminal resistance
Measured while the output terminals are open, with no load on the cell.
Output terminal resistance
Measured while the input terminals are open, with no load on the cell.
Insulation resistance
The direct current resistance between the load cell unit and its circuit.
3
Single Point
Single-point load cells are ideal to be used alone and
for relatively small loading.
They are already adjusted to correct four-corner errors.
Example Applications
●Electronic balances
●Desktop scales
●Small/medium-sized platform scales
●Conveyer scales, etc.
Example of Installation
The LCB04
Corner point
200(MAX)
Base
200(MAX)
Corner line
Platform of platform Corner stopper
Unit = mm
200(MAX) 200(MAX)
4
Single Point
LCB03/04 Series
Single-point Aluminum Load Cell
LCB03M/L Series
Unit = mm Specifications
130 CABLE COLOR CODE
12 106 12 4-M6 RED EXC+ Rated output 2mV/V±10%
WHITE EXC–
GREEN SIG+
Safe load limit 150% of R.C.
BLUE SIG–
YELLOW SHIELD
Combined error 0.02% of R.O.
15 30
(40) Recommended excitation voltage DC5 to 12V
(40) : L Series Maximum excitation voltage DC15V
25 80 25
Zero balance ±5% of R.O.
Input terminal resistance 420±30Ω
22 Output terminal resistance 350±5Ω
Net Weight : 0.23kg Insulation resistance 2000MΩ/DC50V(B/E)
(L Series : 0.3kg)
LCB04M Series Compensated temperature range –10ºC to 40ºC
150
6 18 102 18 6 M6 34mm deep Temperature effect on
Zero balance 0.023% of R.O./10ºC
Span 0.014% of Load/10ºC Typ.
40
ø3.5/1.5m (LCB04)
4-M6 16mm deep 2-M6 16mm deep Maximum platform size 300✕300mm (LCB03)
30
400✕400mm (LCB04)
Dustproof/waterproof IP54
34
30
Net Weight : 0.5kg
LCB04L Series
150
6 20 98 20 6 4-M8 16mm deep
20
40
20
32
Net Weight : 0.5kg
5
Single Point
LCB05 Series
Hermetically Sealed Single-point Stainless Steel Load Cell
Ideal for measurements in harsh environments
Specifications
Rated output 2mV/V+15% –0%
Safe load limit 150% of R.C.
Combined error 0.03% of R.O.
Recommended excitation voltage DC5 to 12V
Maximum excitation voltage DC15V
Zero balance ±5% of R.O.
Input terminal resistance Approximately 390Ω
Output terminal resistance 350±5Ω
Insulation resistance 500MΩ/DC50V
Compensated temperature range –10ºC to 40ºC
Unit = mm CABLE COLOR CODE Temperature effect on
10 150 RED EXC +
LCB05K030/060 Zero balance 0.04% of R.O./10ºC
WHITE EXC –
GREEN SIG + Span 0.014% of Load/10ºC Typ.
BLUE SIG –
40
18
30
19
10 150
LCB05K150
20
40
30
19
32 86
6
Single Point
LC-4001
Single-point Aluminum Load Cell with Ultra-high Sensitivity
Resolution as high as 10mg
Built-in metal overload stopper
Model No. Capacity
LC-4001-G120 122.4g (1.2N)
Specifications
Rated output 0.4079mV/V or greater
Safe load limit 300% of R.C.
Combined error 0.015% of R.O.
Recommended excitation voltage DC5 to 12V
Maximum excitation voltage DC15V
Zero balance 40±25% of R.O.
Input terminal resistance Approximately 400Ω
Output terminal resistance 350±5Ω
Insulation resistance 500MΩ/DC50V
Compensated temperature range –5ºC to 35ºC
Temperature effect on
Zero balance 0.14% of R.O./10ºC
Span 0.02% of Load/10ºC Typ.
Cable diameter/length F.P.C.75mm
Maximum platform size 120✕120mm
Dustproof/waterproof IP22
Depth 8
Approx. 66
Unit = mm
Net Weight : 0.26kg
7
Single Point
LC-4101 Series
Single-point Aluminum Load Cell Ideal for Small
Capacity Weighing
Specifications
Rated output 1.0197mV/V+15% –0%
Safe load limit 300% of R.C.
Combined error 0.015% of R.O.
Recommended excitation voltage DC5 to 12V
Maximum excitation voltage DC15V
Zero balance 20±5% of R.O.
Input terminal resistance Approximately 400Ω
Output terminal resistance 350±5Ω
Insulation resistance 500MΩ/DC50V
Compensated temperature range –10ºC to 40ºC
Temperature effect on
Zero balance 0.04% of R.O./10ºC
Span 0.014% of Load/10ºC Typ.
Cable diameter/length ø4/1.5m
Maximum platform size 300✕300mm
Dustproof/waterproof IP22
CABLE COLOR CODE 6-M4 Depth 10
RED EXC +
WHITE EXC –
GREEN SIG +
BLUE SIG –
YELLOW SHIELD
Approx.1.5m ø4
Unit = mm
Net Weight : 0.12kg
8
Single Point
LC-4102 Series
Single-point Aluminum Load Cell Ideal for Small/Medium
Capacity Weighing
Specifications
Rated output 1.0197mV/V+15% –0%
Safe load limit 300% of R.C.
Combined error 0.015% of R.O.
Recommended excitation voltage DC5 to 12V
Maximum excitation voltage DC15V
Zero balance 20±5% of R.O.
Input terminal resistance Approximately 400Ω
Output terminal resistance 350±5Ω
Insulation resistance 500MΩ/DC50V
Compensated temperature range –10ºC to 40ºC
Temperature effect on
Zero balance 0.04% of R.O./10ºC
Span 0.014% of Load/10ºC Typ.
Cable diameter/length ø4/1.5m
Maximum platform size 400✕400mm
Dustproof/waterproof IP54
CABLE COLOR CODE
RED EXC +
WHITE EXC –
GREEN SIG +
BLUE SIG –
YELLOW SHIELD
4-M6 Depth 15 2-M6 Depth 15
Rear Protective cover M6 Pierced
Cable
Loading area
Load
Unit = mm
Net Weight : 0.6kg Width of shelf
9
Single Point
LC-4103 Series
Single-point Aluminum Load Cell Ideal for Medium
Capacity Weighing
Specifications
Rated output 1.0197mV/V+15% –0%
Safe load limit 300% of R.C.
Combined error 0.015% of R.O.
Recommended excitation voltage DC5 to 12V
Maximum excitation voltage DC15V
Zero balance 20±5% of R.O.
Input terminal resistance Approximately 400Ω
Output terminal resistance 350±5Ω
Insulation resistance 500MΩ/DC50V
Compensated temperature range –10ºC to 40ºC
Temperature effect on
Zero balance 0.04% of R.O./10ºC
Span 0.014% of Load/10ºC Typ.
Cable diameter/length ø6/2m
Maximum platform size 400✕600mm
Dustproof/waterproof IP54
2-M8 M8 Pierced
Depth 22
Loading area
Protective cover
Load
10
Single Point
LC-4204 Series
Single-point / Multi-point Aluminum Load Cell
Specifications
Rated output 1.5296mV/V±0.2%
Safe load limit 200% of R.C.
Combined error 0.015% of R.O.
Recommended excitation voltage DC5 to 12V
Maximum excitation voltage DC15V
Zero balance 20±5% of R.O.
Input terminal resistance Approximately 400Ω
Output terminal resistance 350±5Ω
Insulation resistance 500MΩ/DC50V
Compensated temperature range –10ºC to 40ºC
Temperature effect on
Zero balance 0.04% of R.O./10ºC
Span 0.014% of Load/10ºC Typ.
Cable diameter/length ø6/5m
Maximum platform size 600✕700mm
Dustproof/waterproof IP54
Loading area
Protective cover
Load
11
Single Point
LCB22 Series
Single-point Aluminum Load Cell with Built-in
Overload Stopper
Extremely durable structure built to withstand excessive loads and impacts
without the need for additional stoppers
Model No. Capacity
LCB22K006 6kg (58.84N)
LCB22K010 10kg (98.07N)
LCB22K015 15kg (147.1N)
LCB22K020 20kg (196.1N)
LCB22K030 30kg (294.2N)
Specifications
Rated output 1.5mV/V±5%
Safe load limit 500% of R.C.
Ultimate safe overload 1000% of R.C.
Combined error 0.02% of R.O.
Recommended excitation voltage DC5 to 12V
Maximum excitation voltage DC15V
Zero balance ±5% of R.O.
Input terminal resistance 1.13kΩ±100Ω
Output terminal resistance 1kΩ ±10Ω
Insulation resistance 2000MΩ/DC50V
Compensated temperature range –10ºC to 40ºC
Temperature effect on
Zero balance 0.014% of R.O./10ºC Typ.
Span 0.011% of Load/10ºC Typ.
Cable diameter/length ø4/1.5m
Maximum platform size 400✕400mm
CABLE COLOR CODE Dustproof/waterproof IP65 *
150
17 126.5 RED EXC + * Although this load cell is rated IP65 it can be
WHITE EXC – submerged up to 1m in water for up to 30 minutes
GREEN SIG + similar to the IP67 rating.
BLUE SIG –
YELLOW SHIELD
31
54
47.3
31 9 20 12.4
160 47
Mounting surface
19
28
Unit = mm
Net Weight : 0.5kg
12
Beam Type
Beam type (multi-point) load cells are suitable
for large capacity weighing, and
ideal for low-profile scales.
Example Applications
●Platform scales
●Hopper scales
●Tank scales
●Conveyer scales, etc.
Example of Installation
The LCM13
Platform
Load cell
Leveling foot
Platform
Socket
Ball
Socket
Load cell
Frame
13
Beam Type
LCM13 Series
Beam Type Stainless Steel Load Cell
Specifications
Rated output 2mV/V±0.1%
Safe load limit 150% of R.C.
Combined error 0.03% of R.O.
LCM13K200
Recommended excitation voltage DC5 to 12V
Maximum excitation voltage DC15V
Zero balance ±1% of R.O.
Input terminal resistance 380±20Ω
Output terminal resistance 350±3.5Ω
Insulation resistance Greater than 5000MΩ
Weighing Module Kit at DC50V
LCZAP1413 / LCZAP1414 / LCZAP1415 Compensated temperature range –10ºC to 40ºC
* See accessories page Swivel Foot LCZAFT01S Temperature effect on
for more details. Zero balance 0.016% of R.O./10ºC Typ.
Span 0.013% of Load/10ºC Typ.
Cable diameter/length ø4/3m
Dustproof/waterproof IP67
LCM13K500
G H I LCM13T001 130 16 25 76 13 32 2-ø14 M12 ø21 32 15 2 58 1
Direction of Load (Positive output) LCM13T1.5
LCM13T002
171 19 38 95 19 38 2-ø21 M20 ø30.2 38 18 2 76 1.5
J
LCM13T003
K
G H I
G H I
Direction of Load (Positive output)
Direction of Load (Positive output)
J
J
K
K
M M
L
14
Beam Type
LCM13-M Series
Stainless Steel Beam Load Cell with Built-in Vibration
Controllers for Lift Prevention
Ideal for tank and hopper scales when corrosion resistance is required
Built-in stopper with pre-adjusted stop cap for easy installation
Model No. Capacity
LCM13K100-M 102.0kg (1kN)
LCM13K200-M 203.9kg (2kN)
LCM13K300-M 305.9kg (3kN)
LCM13K500-M 509.9kg (5kN)
LCM13T001-M 1.020t (10kN)
LCM13T1.5-M 1.530t (15kN)
LCM13T002-M 2.039t (20kN)
LCM13T003-M 3.059t (30kN)
Specifications
Rated output 2mV/V±0.1%
Safe load limit 150% of R.C.
Permissible horizontal force Maximum 6kN (611kg)
LCM13K100-M ~ T1.5-M
Maximum 12kN (1223kg)
LCM13T002-M ~ T003-M
Permissible lifting force Maximum 20kN (2039kg)
LCM13K100-M ~ T1.5-M
Maximum 30kN (3059kg)
LCM13T002-M ~ T003-M
CABLE COLOR CODE B Combined error 0.03% of R.O.
RED EXC + N F E Additional : 4 washers
M L Use washers to secure
Recommended excitation voltage DC5 to 12V
WHITE EXC –
GREEN SIG + the base. Maximum excitation voltage DC15V
BLUE SIG –
H
4–ø18 4–ø14
at DC50V
(for lower base installation) (for upper plate installation)
Compensated temperature range –10ºC to 40ºC
G Temperature effect on
Zero balance 0.016% of R.O./10ºC Typ.
J
Dustproof/waterproof IP67
I
P O K
15
Beam Type
LCM19 Series
Beam Load Cells for Tank and Floor Scales
Specifications
Rated output 2.0394mV/V±0.1%
Safe load limit 150% of R.C.
Combined error 0.03% of R.O.
Recommended excitation voltage DC5 to 12V
Maximum excitation voltage DC15V
Zero balance ±1% of R.O.
Input terminal resistance 380±20Ω
Output terminal resistance 350±3.5Ω
Insulation resistance Greater than 5000MΩ
at DC50V
Compensated temperature range –10ºC to 40ºC
Temperature effect on
Zero balance 0.011% of R.O./10ºC Typ.
Span 0.013% of Load/10ºC Typ.
Weighing Module Kit Cable diameter/length ø4/3m
LCZAP1413 / LCZAP1414 / LCZAP1415
Dustproof/waterproof IP67
* See accessories page Swivel Foot LCZAFT01S
for more details.
G H I
Direction of load
J
K
M
L
Mounting surface
16
Beam Type
LCM19-M Series
Beam Load Cell with Built-in Vibration Controllers
for Lift Prevention
Excellent for tank and hopper scales
Built-in stopper with pre-adjusted stop cap for easy installation
Model No. Capacity
LCM19K500-M 509.9kg (5kN)
LCM19T001-M 1.020t (10kN)
LCM19T1.5-M 1.530t (15kN)
LCM19T002-M 2.039t (20kN)
Specifications
Rated output 2.0394mV/V±0.1%
Safe load limit 150% of R.C.
Permissible horizontal force Maximum 6kN (611kg)
LCM19K500-M ~ T1.5-M
Maximum 12kN (1223kg)
LCM19T002-M
Permissible lifting force Maximum 20kN (2039kg)
LCM19K500M ~ T1.5-M
Maximum 30kN (3059kg)
LCM19T002-M
Combined error 0.03% of R.O.
Recommended excitation voltage DC5 to 12V
Maximum excitation voltage DC15V
Zero balance ±1% of R.O.
Input terminal resistance 380±20Ω
Output terminal resistance 350±3.5Ω
Insulation resistance Greater than 5000MΩ
B at DC50V
CABLE COLOR CODE N F E Additional : 4 washers
RED EXC + Compensated temperature range –10ºC to 40ºC
M L Use washers to secure
WHITE EXC – the base. Temperature effect on
GREEN SIG +
H
Dustproof/waterproof IP67
H
4–ø18 4–ø14
(for lower base installation) (for upper plate installation)
G
J
A
I
P O K
17
Beam Type
LC-4221 Series
Hermetically Sealed, Beam Type Stainless Steel Load Cell
Ideal for measurements in harsh environments
Specifications
Rated output 2.0394mV/V±0.2%
Safe load limit 200% of R.C.
Combined error 0.05% of R.O.
Recommended excitation voltage DC5 to 12V
Maximum excitation voltage DC15V
Zero balance ±1% of R.O.
Input terminal resistance Approximately 400Ω
Output terminal resistance 350±3.5Ω
Insulation resistance Greater than 5000MΩ
at DC50V
Compensated temperature range –10ºC to 60ºC
Temperature effect on
Zero balance 0.07% of R.O./10ºC
CABLE COLOR CODE 120
Span 0.02% of Load/10ºC Typ.
RED EXC + Cable diameter/length ø6/5m
WHITE EXC – A B C D
GREEN SIG + Dustproof/waterproof IP67
BLUE SIG –
YELLOW SHIELD
ø38
ø26
F
Two face
2-E
width 12
20
12 60 36 24
10 3
20
20
M8(only K010-K050)
Unit = mm
Net Weight : 0.8kg
Model No. A B C D E F
LC4221-K010/020/050 27 18 65 10 ø6.6 ø8.1
LC4221-K100/200/300 25 20 65 10 ø8.4 ø10.1
18
Beam Type
LC-5206 Series
Beam Type Tool Steel Load Cell
Specifications
Rated output 2.0394mV/V±0.2%
Safe load limit 200% of R.C.
Combined error 0.02% of R.O.
Recommended excitation voltage DC5 to 12V
Maximum excitation voltage DC15V
Zero balance ±1% of R.O.
Input terminal resistance Approximately 400Ω
Output terminal resistance 350±3.5Ω
Insulation resistance Greater than 5000MΩ
at DC50V
Compensated temperature range –10ºC to 60ºC
Temperature effect on
Zero balance 0.07% of R.O./10ºC
Span 0.02% of Load/10ºC Typ.
Cable diameter/length ø6/3m (K300/K500)
CABLE COLOR CODE ø6/5m (T001/T002)
RED EXC + Dustproof/waterproof IP67
WHITE EXC –
GREEN SIG +
BLUE SIG –
YELLOW SHIELD
19
Beam Type
LC-5223 Series
Beam Type Tool Steel Load Cell
Specifications
Rated output 2.0394mV/V±0.2%
Safe load limit 150% of R.C.
Combined error 0.03% of R.O.
Recommended excitation voltage DC5 to 12V
Maximum excitation voltage DC15V
Zero balance ±1% of R.O.
Input terminal resistance Approximately 400Ω
Output terminal resistance 350±3.5Ω
Insulation resistance 5000MΩ/DC50V
Compensated temperature range –10ºC to 60ºC
Temperature effect on
Zero balance 0.07% of R.O./10ºC
Span 0.02% of Load/10ºC
CABLE COLOR CODE Cable diameter/length ø4/3m
RED EXC + Dustproof/waterproof IP67
WHITE EXC –
GREEN SIG +
BLUE SIG –
YELLOW SHIELD
Spacer
20
Beam Type
LBP Series
Hermetically Sealed Beam Type Load Cell
Specifications
Rated output 2.0394mV/V+0.2% –0%
Safe load limit 150% of R.C.
Combined error 0.04% of R.O.
Recommended excitation voltage DC5 to 12V
CABLE COLOR CODE Metal bellows
Cable out location for (positive-bellows-protection)
Maximum excitation voltage DC20V
RED EXC + 200L to 10L J Drill(✕2) I Zero balance ±1% of R.O.
WHITE EXC –
GREEN SIG + Input terminal resistance 420±40Ω
BLUE SIG –
H
øQ
øP
øF
YELLOW SHIELD
H
+ Polarity
K (L)
A
Unit = mm
Model No. A B C D E øF øG H I J K L M N øP øQ Net Weight (kg)
LBP-10L ~ 100L 125 72 35 8 10 20 42 12 8 Reamer 8.5 Drill(✕2) 53 20 35 15 42 38.5 0.9
LBP-200L ~ 500L 200 120 45 15 20 30 52 14 12 Reamer 14 Drill(✕2) 80 40 40 25 52 50.5 2
LBP-1 210 125 50 15 20 40 52 15 16 Reamer 18 Drill(✕2) 90 40 40 30 68 65 2.8
20 Drill
LBP-2 215 125 50 20 20 43 58 16 ø26 Spotface 22 Drill(✕2) 95 40 50 34 68 65 4
3 Depth
26 Drill
LBP-5 300 135 120 20 25 61 72 20 ø32 Spotface 22 Drill(✕2) 170 50 60 50 92 90 8
3 Depth
20 Reamer
LBP-10 300 118 135 22 25 68 82 25 ø38+0.1
+0.2
Spotface 32 Drill(✕2) 187 52 70 56 108 90 12
10 Depth
21
Tension Type
Tension type load cells are ideal for tensile
measurements (compression measurements are also possible).
Installation is easy (although safety precautions must be observed).
The structure is less susceptible to biased loading.
Example Applications
●Hopper scales
●Tension measurements, etc.
The LC-1205
Load cell
Rod-end bearing
Joint
22
Tension Type
LC-1205 Series
S-Type Tool Steel Load Cell
Specifications
Rated output 2.0394mV/V±0.5%
1.5296mV/V±0.5% (K020/K050)
Safe load limit 200% of R.C.
250% of R.C. (K020/K050)
Combined error 0.02% of R.O.
Recommended excitation voltage DC5 to12V
Maximum excitation voltage DC15V
Rod-end bearings are sold separately.
Zero balance ±2% of R.O.
Input terminal resistance Approximately 400Ω
Output terminal resistance 350±3.5Ω
Insulation resistance 5000MΩ/DC50V
Compensated temperature range –10ºC to 60ºC
CABLE COLOR CODE (Tension)
RED EXC + Temperature effect on
WHITE EXC – Zero balance 0.07% of R.O./10ºC
GREEN SIG +
BLUE SIG – Span 0.02% of Load/10ºC Typ.
YELLOW SHIELD Cable diameter/length ø6/3m
CABLE COLOR CODE (Compression) ø6/5m (T001A/T002/T005)
RED EXC + Dustproof/waterproof IP54
WHITE EXC –
GREEN SIG –
BLUE SIG +
YELLOW SHIELD
23
Tension Type
LC-1216 Series
Hermetically Sealed Tool Steel Load Cell
Ideal for measurements in harsh environments
Specifications
Rated output 2.0394mV/V±0.5%
Safe load limit 200% of R.C.
Combined error 0.05% of R.O.
Recommended excitation voltage DC5 to 12V
Maximum excitation voltage DC15V
Zero balance ±2% of R.O.
Input terminal resistance Approximately 400Ω
Output terminal resistance 350±3.5Ω
Insulation resistance 5000MΩ/DC50V
Compensated temperature range –10ºC to 60ºC
Temperature effect on
Zero balance 0.07% of R.O./10ºC
Span 0.02% of Load/10ºC Typ.
CABLE COLOR CODE (Tension) Cable diameter/length ø6/3m
RED EXC + ø6/5m (T001A/T002A/T005)
WHITE EXC – Dustproof/waterproof IP67
GREEN SIG +
BLUE SIG –
YELLOW SHIELD
24
Tension Type
LCS15 Series
S-Type Stainless Steel Load Cell
Specifications
Rated output 2mV/V±0.1%
Safe load limit 150% of R.C.
Combined error 0.03% of R.O.
Recommended excitation voltage DC5 to12V
Maximum excitation voltage DC15V
Zero balance ±1% of R.O.
Input terminal resistance 380±20Ω
Output terminal resistance 350±3.5Ω
Insulation resistance 5000MΩ/DC50V
Compensated temperature range –10ºC to 40ºC
Temperature effect on
Zero balance 0.016% of R.O./10ºC
Span 0.013% of Load/10ºC Typ.
Cable diameter/length ø5/4.5m
Dustproof/waterproof IP67
Protective tube
25
Compression Type
Compression type load cells are used for compression
measurements and are suitable for large capacity
weighing.
Example Applications
●Truck scales
●Weigh bridges
●Hopper scales
●Tank scales
●Compression measurements, etc.
Example of Installation
Truck scale
Stopper
Maximum clearance : 5mm
Recommended clearance : 2 to 3mm
Reinforced plate
Use steel conduit
Shunt wire and flexible tube for
load cell cable
Base plate
Mutual level error : within 3mm
Self level : within 1/500
26
Compression Type
LCC07 Series
Hermetically Sealed Stainless Steel Load Cell
Equipped with a transverse load stopper
Specifications
Rated output 2mV/V±0.1%
Safe load limit 150% of R.C.
Combined error 0.03% of R.O.
Recommended excitation voltage DC5 to 12V
Maximum excitation voltage DC15V
Zero balance ±1% of R.O.
Input terminal resistance 780±20Ω
Output terminal resistance 700±10Ω
Insulation resistance 500MΩ/DC50V
Compensated temperature range –10ºC to 40ºC
Temperature effect on
Zero balance 0.04% of R.O./10ºC
CABLE COLOR CODE Span 0.014% of Load/10ºC Typ.
100±1 8-ø12
RED EXC + Cable diameter/length ø5.6/5m
WHITE EXC – 77
Dustproof/waterproof IP67
GREEN SIG +
BLUE SIG –
YELLOW SHIELD
100±1
77
SUS Ball
16
R1/4-19
95
ø78
12
Unit = mm
Net Weight : 4kg
27
Compression Type
LCC11/N Series
Hermetically Sealed Stainless Steel Load Cell
with Very Large Weighing Capacity
High resistance to adverse environmental conditions and corrosion (IP68)
Available with or without mounting kit
Model No. Capacity
LCC11T010/LCC11T010N 10.20t (100kN)
LCC11T020/LCC11T020N 20.39t (200kN)
LCC11T030/LCC11T030N 30.59t (300kN)
Specifications
Rated output 2mV/V±0.1%
Safe load limit 200% of R.C.
Combined error 0.016% of R.O.
Recommended excitation voltage DC5 to 12V
Maximum excitation voltage DC15V
Zero balance ±1% of R.O.
Input terminal resistance 800±80Ω
Output terminal resistance 2200±10Ω
Insulation resistance 5000MΩ/DC50V
Compensated temperature range –20ºC to 60ºC
Temperature effect on
Zero balance 0.019% of R.O./10ºC Typ.
Span 0.010% of Load/10ºC Typ.
Cable diameter/length ø8/12m
CABLE COLOR CODE Dustproof/waterproof IP68 (100h at 1.5m immersion)
200±1
RED EXC +
140
WHITE EXC – 8-ø20
GREEN SIG + (Upper/lower shared)
BLUE SIG –
YELLOW SHIELD
150±1
100
Load
Ground terminal M4
12 84 28
ø72 47 42
36 12
Four-conductor
shielded cable Upper dust cover
199±1
103
Under boots
PT-1/2
108
100
12 36
ø72 ø99
ø94
Unit = mm
Load Net Weight : 7.5kg
28
Compression Type
LCC12 Series
Hermetically Sealed Stainless Steel Weighing Module
with Very Large Weighing Capacity
High resistance to adverse environmental conditions and corrosion (IP68)
Equipped with mount assembly (transverse movement control + lift-off prevention)
Model No. Capacity
LCC12T010 10.20t (100kN)
LCC12T020 20.39t (200kN)
LCC12T030 30.59t (300kN)
Specifications
Rated output 2mV/V±0.1%
Safe load limit 150% of R.C.
Combined error 0.03% of R.O.
Recommended excitation voltage DC5 to 12V
Maximum excitation voltage DC15V
Zero balance ±1% of R.O.
Input terminal resistance 800±80Ω
Output terminal resistance 2200±10Ω
Insulation resistance 5000MΩ/DC50V
Compensated temperature range –20ºC to 60ºC
Temperature effect on
Zero balance 0.019% of R.O./10ºC Typ.
Span 0.010% of Load/10ºC Typ.
Cable diameter/length ø8/12m
Dustproof/waterproof IP68 (100h at 1.5m immersion)
YELLOW SHIELD
270±2.2
Four-
18
Ground conductor
terminal shielded
M4 cable
225±1
PT-1/2
127
18
300±2.2
29
Compression Type
LC-2224 Series
Column Type Load Cell Ideal for Truck Scales and Hoppers
Specifications
Rated output 2mV/V±0.1%
Safe load limit 200% of R.C.
Combined error 0.02% of R.O.
Recommended excitation voltage DC5 to 12V
Maximum excitation voltage DC15V
Zero balance ±1% of R.O.
Input terminal resistance 410±30Ω
Output terminal resistance 355±3.5Ω
Insulation resistance 5000MΩ/DC50V
Compensated temperature range –20ºC to 60ºC
Temperature effect on
Zero balance 0.009% of R.O./10ºC
Span 0.012% of Load/10ºC Typ.
Cable diameter/length ø8/10m
CABLE COLOR CODE Dustproof/waterproof IP67
RED EXC +
WHITE EXC –
GREEN SIG +
BLUE SIG –
YELLOW SHIELD
The top and bottom plate
dimensions are the same.
30
Compression Type
Specifications
Rated output 3.0592mV/V±0.1%
Safe load limit 150% of R.C.
500% of R.C.(20L to 100L)
Combined error 0.05% of R.O.
Recommended excitation voltage DC5 to 12V
Maximum excitation voltage DC20V
Zero balance ±1% of R.O.
Input terminal resistance 350±3.5Ω
Output terminal resistance 350±5Ω
Insulation resistance 5000MΩ/DC50V
Compensated temperature range –10ºC to 75ºC
Temperature effect on
Zero balance 0.03% of R.O./10ºC
Span 0.03% of Load/10ºC
Cable diameter/length ø9.7/3m
Dustproof/waterproof IP67
CP
CABLE COLOR CODE For the 200L model and higher, we can also manufacture two-bridge, low-temperature, and
high-temperature models. Unit = mm
36
RED EXC +
WHITE EXC – Spherical
Model No. øA B C øD E F (G) Radius øI J Net Weight (kg)
GREEN SIG + H
BLUE SIG – TP-20L ~ 100L
75
J TP-20
165 290 78 145 15 28 194 200 58 M50✕2 Depth 65 27.0
(E)
CP-20
H (sp
TP-30
herica
CP-30
42
l radiu
TP-50
s)
J 232 452 145 195 30 48 263 300 82 M76✕3 Depth 115 88.0
CP-50
C
øD TP-100
310 610 180 262 30 70 343 300 108 M100✕3 Depth 150 200.0
1.5
CP-100
31
Compression Type
C2F1/C2Z1/C2X1 Series
Hermetically Sealed Compression Load Cell
Ideal for measurements in harsh environments
(F)
CABLE COLOR CODE
RED EXC +
WHITE EXC –
GREEN SIG +
36
BLUE SIG –
YELLOW SHIELD
Unit = mm
75
(16)
ical radius
C2X1-200 214 230 300 130 4-M16 Depth 25 245 180 30 95 100 2 34
P.C.D.
L
D
4-E C2X1-300 214 320 600 130 4-M24 Depth 35 245 180 30 120 150 2 50
øG
C2X1-500 316 400 800 200 6-M30 Depth 50 349 260 30 170 200 2 140
32
Compression Type
CMX/CM Series
Hermetically Sealed Compression Load Cells
Miniature size and waterproof light weight construction
Specifications
Rated output 2.0394mV/V±0.4% (CMX)
2.0394mV/V±0.5% (CM)
Safe load limit 150% of R.C.
Combined error 0.2% of R.O. (CMX)
CABLE COLOR CODE
ø62 Unit = mm 0.25% of R.O. (CM)
RED EXC + CMX ø12
Recommended excitation voltage DC5 to 12V
3
GREEN SIG +
25
22
19
83
Output terminal resistance 350±5Ω
Insulation resistance 1000MΩ/DC50V
Compensated temperature range –10ºC to 60ºC
20
Temperature effect on
Zero balance 0.1% of R.O./10ºC
P.C.D.42
40
CM ø114
ø25
(47)
(16)
PT 1/2 14 threads per inch
5
ø8.6 Cable
spheric
50
ø22
20
al radius
100
P.C.D. 90
M8✕4, 15 Depth
33
Compression Type
TM/UM Series
Hermetically Sealed Load Cells for Multiple Applications
Tension-TM, Tension and Compression-UM
TM (-A) Specifications
UM Rated output 2.0394mV/V±0.5%
Safe load limit 150% of R.C.
Combined error 0.2% of R.O.
Recommended excitation voltage DC5 to 12V
TM
Maximum excitation voltage DC18V
Zero balance ±10% of R.O.
Input terminal resistance 425±50Ω
TM UM Output terminal resistance 350±5Ω
CABLE COLOR CODE CABLE COLOR CODE
RED EXC + RED EXC + Insulation resistance 1000MΩ/DC50V
WHITE EXC – WHITE EXC – Compensated temperature range –10ºC to 60ºC
GREEN SIG – GREEN SIG +
Temperature effect on
BLUE SIG + BLUE SIG –
YELLOW SHIELD YELLOW SHIELD Zero balance 0.1% of R.O./10ºC
øA (62) Span 0.1% of Load/10ºC
øG Cable diameter/length ø5/3m
1.6 Slot Dustproof/waterproof IP67
UM (-A) Specifications
Rated output 2.0394mV/V±1% (Tension)
D
(ø12)
E
34
Button Load Cell
LCC21 Series
Stainless Steel Compact Compression Load Cell
Can be used for load distribution and press pressure measurement
Specifications
Rated output 1mV/V or more
Safe load limit 150% of R.C.
Combined error 0.5% of R.O.
Recommended excitation voltage DC5V
Maximum excitation voltage DC5V
Zero balance ±100% of R.O.
LCC21N100/N200 Input terminal resistance 1kΩ ±0.1kΩ
LCC21N500/KN001 Output terminal resistance 1kΩ ±0.01kΩ
Insulation resistance 500MΩ/DC50V
Compensated temperature range 0ºC to 70ºC
Standard attachment holder
Permissible temperature range –10ºC to 80ºC
Temperature effect on
Zero balance 0.5% of R.O./10ºC Typ.
Span 0.5% of Load/10ºC Typ.
Cable diameter/length ø2mm/2m
CABLE COLOR CODE Dustproof/waterproof IP64
Stainless steel load cell Attachment holder
RED EXC + Include standard attachment holder 1 piece
WHITE EXC – G
B
GREEN SIG + A H 2-ø3.5 Resonance frequency
ø2
BLUE SIG –
LCC21N100 LCC21N200 LCC21N500 LCC21KN001
YELLOW SHIELD
45kHz 55kHz 30kHz 35kHz
Force direction
J
I
C
D
E
Stainless steel
F
35
Button Load Cell
LCCA21 Series
Stainless Steel Compact Compression Load Cell
Can be used for load distribution and press pressure measurement
Specifications
Safe load limit 150% of R.C.
Combined error 0.5% of R.O.
Supply voltage DC5V±0.25V less than 16mA
Load resistance more than 5kΩ
Output voltage 1V to 4V *1
Zero voltage 1V±0.04V
Span voltage 2V±0.01V (1V to 3V)
Insulation resistance 500MΩ/DC50V
between signal wires and load cell
Compensated temperature range 0ºC to 70ºC
Permissible temperature range –10ºC to 80ºC
Temperature effect on
Zero balance 0.6% of R.O./10ºC Typ.
Span 0.6% of Load/10ºC Typ.
Stainless Attachment holder G
CABLE COLOR CODE B Frequency characteristics 100Hz (–3dB)
A H 2-ø3.5
RED Power + steel
load cell Cable diameter/length
WHITE Power –
GREEN Output From load cell to amplifier ø2mm/2m
Force direction
J
I
Attachment surface
Include standard attachment holder 1 piece and
Amplifier 99 amplifier case holder 1 set
32
Resonance frequency
LCCA21N100 LCCA21N200 LCCA21N500 LCCA21KN001
45kHz 55kHz 30kHz 35kHz
Nickel plating *1
13
2-ø3.5
36
Flameproof Type
Flameproof load cell series with TIIS certificates
In factories and locations where explosive fumes, oils, and other dangerous flammable items are handled,
products with flameproof constructions must be used to prevent fires from electrical sparks and heat.
A&D load cells have passed type approval of electrical equipment for use in explosive atmospheres
by the Technology Institution of Industrial Safety (TIIS).
2. Temperature class in TIIS Temperature class Maximum surface temperature of flameproof equipment Temperature class Ignition temperature of gases and vapors
In the past, ignition temperatures were classified T1 Items of 450°C or less G1 Items exceeding 450°C
by the gas or vapor ignition temperature, T2 Items of 300°C or less G2 Items exceeding 300°C
but international standards now classify them T3 Items of 200°C or less G3 Items exceeding 200°C
by the maximum surface temperature of the T4 Items of 135°C or less G4 Items exceeding 135°C
flameproof equipment and are noted in the T5 Items of 100°C or less G5 Items exceeding 100°C
T6 Items of 85°C or less G6 Items exceeding 85°C
following manner.
3. Typical explosion classes and ignition temperatures ●Classification by location of use in TIIS
Ignition
temperatures Locations (zones) that require flameproof measures are
G1 G2 G3 G3
Explosion
classes classified from 0 to 2 by the degree of hazardous
Acetone Ethanol Gasoline Acetaldehyde atmosphere. It is necessary to select the equipment
Ammonia Butanol Hexane Ethyl ether
according to these location classes.
Ethane Butane Pentane
1 Toluene Carbon dioxide Zone 0: A location where a dangerous atmosphere is
Acetic acid continually present or present for a long period
Methane
under normal conditions.
Propane
Coal gas Ethylene Isoprene Zone 1: A location where a dangerous atmosphere
2
Ethylene oxide Hydrogen sulfide may be generated under normal conditions.
3 Hydrogen Acetylene
Zone 2: A location where a dangerous atmosphere
may be generated under abnormal conditions.
37
Flameproof Type
LCB01/02/06 Series
Flameproof Single-point Load Cells
Flameproof class TIIS ExdIIBT4 compliant
Specifications
Rated output 0.3059mV/V±10% (LCB01/02)
LCB01/02 Series 0.55mV/V±10% (LCB06)
Safe load limit 150% of R.C.
Combined error 0.03% of R.O.
Recommended excitation voltage DC5 to 12V
Maximum excitation voltage DC15V
Zero balance 20±5% of R.O.
Input terminal resistance 418±20Ω (LCB01/02)
410±20Ω (LCB06)
Output terminal resistance 348.5±5Ω (LCB01/02)
350±5Ω (LCB06)
Insulation resistance 5000MΩ/DC50V
Compensated temperature range –10ºC to 40ºC
Temperature effect on
Zero balance 0.05% of R.O./10ºC
Span 0.03% of Load/10ºC Typ.
Maximum platform size 400✕400mm (LCB01)
400✕600mm (LCB02)
LCM06 Series 600✕700mm (LCB06)
Cable diameter/length ø7/6m
Dustproof/waterproof IP54
52~56 287
LCB01/02 Series LCB06 Series
24 40 165 40 18
13
A
Double-sided
C
width 24
ø57
150
124
D
E
B
44
75
ø38
22
H
I
G
130.6
106
82.3
40.3
J K J L N
22
O M M
Earth terminal M4 100
LCB06 Series Net Weight : 10kg
LCM17/LCM17-M Series
Flameproof Beam Type Stainless Steel Beam Load Cells
Flameproof class TIIS ExdIIBT4 compliant
Specifications
Rated output 1.0mV/V±0.1%
LCM17-M Series
(0.5mV/V±0.1% for 1kN)
Load limit 150% of R.C.
Combined error 0.03% of R.O.
Recommended excitation voltage DC5 to 12V
Maximum excitation voltage DC15V
Zero balance ±2% of R.O.
Input terminal resistance 390±30Ω
Output terminal resistance 350±5Ω
Insulation resistance Greater than 5000MΩ
LCM17 Series
CABLE COLOR CODE at DC50V
Double-sided width 24
A
B RED EXC +
Compensated temperature range –10ºC to 40ºC
C D E F M WHITE EXC –
GREEN SIG + Temperature effect on
BLUE SIG – Zero balance 0.028% of R.O./10ºC
YELLOW SHIELD
Span 0.011% of Load/10ºC Typ.
G
H
LCM17K200E
6
LCM17K300E (256) 170 56 25 76 13 43 32 43 41 94 M12 ø21 ø14 20.5 88 54 2.8 Female screw G1/2(PF1/2)
(Normal diameter of
H
LCM17K100E-M
øR
LCM17K200E-M
A
LCM17K300E-M 118 238 124 90 42 140 180 17 24 16 25 125 15 56 54 157 54.5 38 324 8.7
Q
LCM17K500E-M
I
LCM17T001E-M P O K
LCM17T002E-M 132 274 124 90 42 172 180 17 24 16 25 125 15 60 54 193 57 43 360 11.2
Unit = mm Net Weight = kg
39
Flameproof Type Equipment
41
Equipment
dustproof/waterproof (IP67).
Up to 4 connections possible.
40
200
166
184
Equipped with load cell
40
sensitivity adjustment trimmer.
For load cell cable diameters
30
between 4 to 12mm.
2-
ø8
166
67
Net Weight =1.5kg
Unit = mm
2-ø8
25
3
42
Equipment
B
Applicable range chart
E
Model No. CP/CP-FP Model M16
D
LCZAP0405 200L~1 6-øJ F E D
LCZAP0411 10
15
H
* Intended load cells for CP/CP-FP
X-Load Direction
A
I
Model No. A B C D E F G H (I) J K L
LCZAP0405 154 170 300 11.5 77 200 100 15 124 8 25 250
LCZAP0408 213 200 315 12.5 105 185 130 23 167 12 40 265
H
LCZAP0411 303 230 330 17.5 125 170 160 30 243 14 55 280 L
4-ø
(sold separately)
Load cell
LCM13K100 LCM13T002 LCM13T005
G
LCM13K200
Intended LCM13K300 LCM13T003
LCM13K500
load cells LCM13T001 LCM19T002
LCM13T1.5
LCM19K500
LCM19T001
B
F
LCM19T1.5
Max. horizontal force 6kN 12kN 20kN
L
C
E
4-
H D H
Net Weight 3.4kg 6.0kg 12.0kg
øG
C
* Net weight does not include load cell
Model No. A B C D E F øG H I J K L
LCZAP1413 97 168 100 70 15 136 14 15 20 23 50 70
LCZAP1414 116 212 120 84 18 175 14 18 24 26 60 84 I J
A
LCZAP1415 121 227 150 100 18 190 14 25 24 29 75 114
LCM19K500
LCM19T001
LCM19T1.5
20
10
ø58
20 to 25
LCM13K500
LCM13T001
20
43
Accessories
Mounting Fixtures
Rod-end bearings
Order No. Intended load cells Remarks
LCB-A6 LC1205-K020/K050/K100, LC1216-K100, LC1122-K050/K100 M6✕1
LCB-A12 LC1205-K200/K500, LC1216-K200/K500, LC1122-K250/K500 M12✕1.75
LCB-A18 LC1205-T001A, LC1216-T001A M18✕1.5
LCB-18 LC1205-T002 M18✕1.5
LCB-24-2T LC1216-T002A M24✕2
LCB-24-5T LC1205-T005, LC1216-T005 M24✕2
Mounting illustration
Mounting illustration Mounting illustration
LC-1205 LC-1216
Approximately
Approximately
Approximately
Approximately
Unit = mm Unit = mm
Model No. Rod-end bearings A B C øDH7 E F Model No. Rod-end bearings A B C øDH7 E F
LC1205-K020/K050/K100 LCB-A6 116 134 18 6 7 9 LC1216-K100 LCB-A6 160 178 18 6 7 9
LC1205-K200/K500 LCB-A12 152 182 30 12 12 16 LC1216-K200/K500 LCB-A12 194 224 30 12 12 16
LC1205-T001A LCB-A18 194 236 42 18 17 23 LC1216-T001A LCB-A18 270 312 42 18 17 23
LC1205-T002 LCB-18 214 257 43 18 16.3 20 (LC1216-T002) LCB-18 285 328 43 18 16.3 20
LC1205-T005 LCB-24-5T 268 338 70 25 25.3 35 LC1216-T002A LCB-24-2T 320 376 56 25 22 31
LC1216-T005 LCB-24-5T 342 412 70 25 25.3 35
Mass: 85g
)
(69)
.81
54±0.5
23
(Sø
33±0.3
M12✕1.75
0
LCZARE18S 23−0.13
42±0.5
Applicable load cell: LCS15T001 16.5±0.3
(ø21.9)
Mass: 258g
5)
(93)
1.7
ø3
72±0.5
(S
44±0.7
M18✕1.5
0
LCZARE24S 56±0.5
31−0.13
22±0.3
Applicable load cell: LCS15T002
Static radial load rating: 17.4kN
Static fracture load: 69.62kN
ø25 H7
(ø29.6)
Mass: 730g
)
.86
(122)
2
ø4
94±0.5
(S
57±0.7
M24✕2.0
*When using a stainless steel rod end bearing,
set the normal load to 1/2 of the rated capacity.
*One stainless steel nut (Type 1) is included as standard.
44
Accessories
Compression fixtures
Intended load cells Components - Single convex Components - Double convex
Bearing plate Mounting plate Load button Bolt Button-hole plate Load button Bolt
LC1205-K020/K050/K100 LCBP-1 LCMP-1 LCLB-1 M6 LCBHP-1 LCLB-1 M6
LC1205-K200/K500 LCBP-1 LCMP-2 LCLB-2 M6 LCBHP-1 LCLB-2 M6
LC1205-T001A/T002 LCBP-2 LCMP-4 LCLB-4 M10 LCBHP-2 LCLB-4 M10
LC1205-T005 LCBP-2 LCMP-5 LCLB-5 M10 LCBHP-3 LCLB-5 M10
*A bolt is included to attach the load cell
Single convex Double convex to the mounting plate.
E
E
H
A
Load cell LC-1205
Load button (LCLB)
D
D
Button-hole plate (LCBHP)
C
B
C
B
8-øF 8-øF
B B
C C
Unit = mm Unit = mm
Compression fixtures
Intended load cells Components - Single convex Components - Double convex
Bearing plate Mounting plate Load button Bolt Button-hole plate Load button Bolt
LC1216-K100 LCBP-1 LCMP-1 LCLB-1 M6 LCBHP-1 LCLB-1 M6
LC1216-K200/K500 LCBP-1 LCMP-2 LCLB-2 M6 LCBHP-1 LCLB-2 M6
LC1216-T001A/(T002) LCBP-2 LCMP-4 LCLB-4 M10 LCBHP-2 LCLB-4 M10
LC1216-T002A/T005 LCBP-2 LCMP-5 LCLB-5 M10 LCBHP-3 LCLB-5 M10
*A bolt is included to attach the load cell
Single convex Double convex to the mounting plate.
J J
O ring
(Attachment of LCBHP)
A
H
H
A
C
B
8-øF 8-øF
B B
C C
Unit = mm Unit = mm
45
Accessories
Mounting Fixtures
Universal shackle
For TP For TM
E D
C
øEH7
øA
Min B
(C)
A±1.0
D hexagonal nut øF
øHH7 G
F
øB
Unit = mm Unit = mm
Intended load cells Model No. øA B C D hexagonal nut E F G øHH7 Net Weight (kg) Intended load cells Model No. øA øB C D øEH7 øF Net Weight (kg)
TP-20L ~ 100L S-1 89 183 209 M10✕1.25 26 14 10.5 10 0.2 TM-50L-A
0
TP-200L ~ 1 S-2 89 195 229 M12✕1.25 34 16 13.3 12 0.3 TM-100L-A SM-1 138 30 12+0.1 16–0.1 12 50 0.2
TP-2 ~ 5 S-3A 89 280 342 M24✕2 62 28 19.3 22 1.4 TM-200L-A
TP-10 S-4 125 461 561 M39✕2 100 43 39 40 9 TM-500L ~ 1 SM-2A 170 38 15 21 16 62 0.4
0
TP-20 S-5 165 622 742 M50✕2 120 53 49 50 17 TM-2 SM-2 170 39 15.25+0.13 19–0.13 16 62 0.4
Note: The Min B dimension is the attachment minimum dimension when Note: When the TM series is used, we recommend use of a universal
the shackle is screwed in completely. The attachment is attached in shackle (for tension) to prevent bending load on the load cell.
the range of B to B+0.2 mm. (The shackle screw is rotated back
about half a turn to line up with the shackle position.)
46
Bearing plate (BP), mounting plate (MP), expansion assembly and mounting plate (EA)
Use the bearing plate and mounting plate If you anticipate bending load on the load cell from heat expansion,
when attaching the load cell. use the EA.
Mounting illustration - Bearing plate, Mounting plate Mounting illustration - Expansion assembly (EA), Mounting plate
C 4-øF
C 4-øF D Mounting plate (MP)
D Bearing plate (BP)
E
G
(K)
(K)
A
A
øL
M
E
D
Mounting plate (MP)
G
C
4-øF D
C
Expansion assembly (EA)
4-øF
20 100
10
20 100
10
Weld
50 Weld
50
Unit = mm Unit = mm
Note: The BP-100, MP-100, and EA-100 and higher have handles attached
to their plates.
Intended Bearing Plate and Mounting Plate Dimensions Expansion Assembly (EA) and Mounting Plate Dimensions
load cells Model No. A C D E øF G K Net Weight (kg) Model No. A C D E øF G øL K M ±N Net Weight (kg)
CP-20L ~ 100L BP-1, MP-1 152 100 77 15 8 15 122 3 EA-1, MP-1 177 100 77 15 8 15 60 122 25 ±8 4
CP-200L ~ 1 BP-1, MP-1 154 100 77 15 8 15 124 3 EA-1, MP-1 179 100 77 15 8 15 60 124 25 ±8 4
CP-2 ~ 5 BP-2, MP-2 213 130 105 23 12 23 167 6 EA-2, MP-2 248 130 105 23 12 23 90 167 35 ±8 8
CP-10 BP-10, MP-10 303 160 125 30 14 30 243 12 EA-10, MP-10 348 160 125 30 14 30 110 243 45 ±10 16
CP-20 BP-20, MP-20 378 200 150 30 14 30 318 18 EA-20, MP-20 443 200 150 30 14 30 130 318 65 ±10 26
CP-30 BP-30, MP-30 480 240 180 40 19 40 400 36 EA-30, MP-30 545 240 180 40 19 40 160 400 65 ±15 46
CP-50 BP-100, MP-110 620 260 200 60 23 60 500 65 EA-100, MP-110 710 260 200 60 23 60 210 500 90 ±15 96
CP-100 BP-210, MP-210 800 360 280 60 27 60 680 130 EA-200, MP-210 905 360 280 60 27 60 300 680 105 ±15 180
C2Z1-500L ~ 2 131 130 105 23 12 23 85 6 166 130 105 23 12 23 90 85 35 ±8 8
BP-2, MP-2 EA-2, MP-2
C2F1-500L ~ 2 151 130 105 23 12 23 105 6 186 130 105 23 12 23 90 105 35 ±8 8
C2Z1-5, 10 170 160 125 30 14 30 110 12 215 160 125 30 14 30 110 110 45 ±10 16
BP-10, MP-10 EA-10, MP-10
C2F1-5, 10 160 160 125 30 14 30 100 12 205 160 125 30 14 30 110 100 45 ±10 16
C2Z1-20 205 200 150 30 14 30 145 18 270 200 150 30 14 30 130 145 65 ±10 26
BP-20, MP-20 EA-20, MP-20
C2F1-20 180 200 150 30 14 30 120 18 245 200 150 30 14 30 130 120 65 ±10 26
C2X1-30, 50 BP-50, MP-50 240 220 160 40 19 40 160 30 EA-50, MP-50 305 220 160 40 19 40 160 160 65 ±15 40
C2X1-100 BP-100, MP-100 310 260 200 60 23 60 190 64 EA-100, MP-100 400 260 200 60 23 60 210 190 90 ±15 86
360 (EA) 280 (EA)
C2X1-200 BP-200, MP-200 390 280 200 80 27 80 230 100 EA-200, MP-200 475 80 27 60 300 230 105 ±15 170
280 (MP) 200 (MP)
400 (EA) 320 (EA)
C2X1-300 BP-300, MP-300 500 280 200 80 35 100 320 110 EA-300, MP-300 585 80 35 60 350 320 125 ±15 222
280 (MP) 200 (MP)
500 (EA) 400 (EA)
C2X1-500 BP-500, MP-500 630 380 280 100 40 130 400 260 EA-500, MP-500 745 100 40 80 430 400 165 ±15 457
380 (MP) 280 (MP)
CMX-50L ~ 2 BP-2-A, MP-2-A 55 130 105 15 12 15 25 4 EA-2, MP-2-A 98 130 105 15 12 23 90 25 35 ±8 7
CMX-5 ~ 20 BP-10, MP-10-A 110 160 125 30 14 30 50 12 EA-10, MP-10-A 155 160 125 30 14 30 110 50 45 ±10 16
N : Permitted movement range
47
Appearance and/or specifications subject to change for improvement without notice.
✽ Load Cells-ADCC-03-ZW3-16103