EZ Intelligent Relay: Product Focus
EZ Intelligent Relay: Product Focus
Product Focus
Easy operation
with maximum benefits
The Eaton EZ intelligent relays provide basic
functions that users could only implement
previously with individually installed and wired
devices. The EZD multi-function displays offer
powerful visualization functions.
2
Eaton’s EZ line really is
easy to use. In associa-
tion with EZD, it offers
everything you need
from a state-of-the-art
automation system:
flexible networking,
local and remote
expansion modules,
visualization, scalability.
Simplicity and
user-friendly operation
EZ and EZD products are
known for their user-friendly
operation and programming.
Every rung or circuit connection
is wired just like you remember:
Contact – Contact – Contact –
Coil – Done! The devices allow
the “wiring” of 128 or 256
rungs or circuit connections.
Series and parallel connections,
which make up a major part
of a control circuit, are easily
created without previous
programming knowledge.
Ready-to-use function blocks
are simply integrated in the
wiring with coils, and contacts
are provided for additional
functions.
3
Technical overview:
The right device for every application
EZ500 intelligent relay EZ700 intelligent relay EZ800 intelligent relay EZD intelligent relay
For controlling small For controlling medium-sized For controlling large-scale For controlling large-scale
applications with up to 12 applications with up to 40 applications with up to 300 applications with powerful
input/output signals input/output signals input/output signals visualization functions
• 4 digital inputs or • 6 digital relay out- • 6 digital relay out- • 4 digital relay out-
optionally puts or optionally puts or optionally puts or optionally
• 1 analog input
• 1 analog input
(10 bit)
(10 bit)
4
EZ800 and EZD
intelligent relays
The EZ800 and EZD intelligent
relays provide expanded
capabilities. Users can network
up to eight modules to easily
support applications with over
300 I/O points. A control
system can be designed by
using a single local program or
by using several programs on
different distributed devices.
Up to 1000 meters can be
covered by the network. The
intelligent relays can also be
easily integrated with higher-
level automation networks
such as PROFIBUS-DP,
CANopen, DeviceNet and
AS-Interface.
5
Communication made easy.
Simple and inexpensive networking.
6
Communication modules
provide automation interaction
Communication
connections to the
production process
give more flexibility
and control.
Commanding, signaling,
monitoring and controlling
on bit level
A network connection is often
worthwhile for simple operating
steps often found in production
processes. The Actuator-Sensor
Interface, or AS-I, can provide
31 slaves simultaneously with
248 binary data items. For
machine building applications,
AS-I is the optimal network
connection choice because
input/output data can be
transferred with a very fast
reaction time of only 5 ms.
As a result, it is possible to
start up several motors
simultaneously in a materials
handling application.
The EZ205-ASI communication
module makes network
connection easy. It can be
connected via the EZ-LINK
connection to all expandable
EZ units. The two-wire AS-I
cable is simply wired to the
module– that's it! Data
exchange is then organized
by a higher level AS-I master.
Transferring complex data of data per station can be connection. If recipes require Connection to world
More powerful fieldbus systems transferred with each scan, different parameter sets to be standard fieldbus systems
like the PROFIBUS-DP are and up to 126 nodes can be transferred to EZ, clock times, Similar to the EZ204-DP,
used for complex automation linked together over a distance counter states, setpoints and the EZ221-CO network
tasks. These may involve of 1200 meters. The EZ204-DP actual values can be controlled communication module for
transporting large data sets, gateway makes EZ intelligent by a suitable master on this CANopen and the EZ222-DN
such as several analog values, relays more flexible and powerful network system. for DeviceNet offer the same
setpoints, counter states or powerful. Entire parameter functions.
timer parameters. With sets of EZ can be read or
PROFIBUS-DP, up to 20 bytes exchanged by a network
7
Stand alone EZ display
with a high degree of protection
EZ intelligent
relay with EZD
display provides
IP65 protection
The EZD-CP4-500 or
EZD-CP4-800 supply
and communication
module can be combined
with an EZD display
and EZ intelligent relay
providing users with
the option of using a
stand-alone display
with IP65 protection
for all EZ500/700 and
EZ800 applications.
1 2 3 4
1 & 2 Plug & play display to be mounted up to protected to IP65. The display 1, 3 & 4
Plug & play technology allows five meters away from the includes a backlight that offers EZD provides HMI-Control
users to connect an EZD intelligent relay. optimum legibility. When an EZD display is directly
display (EZD-80 or EZD-80-B) No software or drivers are Two EZ-CP4 modules are connected to an EZD-CP8 with
to an EZ intelligent relay via an needed for the connection - available: EZD-CP4-500 is used optional input/output modules,
EZD-CP4 supply and EZD-CP4 is a genuine plug & with all EZ500/700s and the the EZD becomes a compact
communication module. play device. I/O wiring can be EZD-CP4-800 is used with all HMI control device. It combines
The EZD-CP4 module is kept in the control panel and EZ800 and EZD-CP8 devices. the functionality of an EZ800
factory shipped with five the EZD-CP4 simply snaps to with powerful visualization
meters of serial connection the EZD display. When properly functions. The two modules
cable that can be cut to any mounted, the display is are simply plugged together.
required length allowing the
8
More input/output
Central and
Decentralized
Expansion
Made Easy
The EZ700, EZ800
and EZD accommodate
I/O expansion locally
or remotely using a
variety of different
configurations.
1 2 3
1 2 3
By connecting an EZ618-AC-RE, Alternatively, a connection can The EZ202-RE expansion
EZ618-DC-RE or EZ620-DC-TE be set up using the EZ200-EZ module provides two additional
expansion module, users can coupling module and a 2-wire relay outputs that can be
create an intelligent relay with cable allowing an expansion connected directly using the
24 inputs and up to 16 outputs. module to be remotely mounted EZ-LINK connector.
These three expansion modules up to 30 meters away.
are simply fitted onto the EZ
controller and directly connected
using the EZ-LINK interface
connector.
9
EZ512-AC-RC EZ512-DC-TCX EZ512-DA-RC
CX
X
X
-RC
-RC
-RC
-RC
-R
-R
-RC
-RC
-RC
A-R
-AC
-DC
-DA
-DC
-AB
-AC
Type
-DC
-AB
-AC
2-D
512
512
512
512
512
512
512
512
512
251
EZ
EZ
EZ
EZ
EZ
EZ
EZ
EZ
EZ
EZ
Supply voltage 24 V AC 100 - 240 V AC 12 V DC 24 V DC
Heat dissipation 5 VA 5 VA 2W 2W
Inputs, digital 8 8 8 8 8 8 8 8 8 8
Outputs, analog 0 - 10 V - - - - - - - - - -
LCD display / keypad Yes / Yes -/- Yes / Yes Yes / Yes -/- Yes / Yes -/- Yes / Yes Yes / Yes -/-
7-day / year time switch Yes / Yes Yes / Yes -/- Yes / Yes Yes / Yes Yes / Yes Yes / Yes -/- Yes / Yes Yes / Yes
Short-circuit proof with power factor 0.7... 0.7 Line protection B16, 900 A
Degree of protection IP 20
Dimensions (W x H x D) mm 71.5 x 90 x 58 mm
[1] Relay = 8 A (10 A to UL) with resistive load, 3 A with inductive load/transistor outputs = 0.5 A / 24 V DC, max 4 outputs switchable in parallel.
[2] With backlight in continuous operation - 10 °C ... 0 °C.
[3] In stand-alone operation the EZD-...CP8-... CPU slices can also be mounted on a DIN 50022 top-hat rail, 35 mm or as screw mounting with EZB4-101-GF1 fixing brackets.
10
EZ719-AC-RCX EZ721-DC-TC
Expandable (EZ2…EZ6…)
X
X
X
X
-RC
-RC
-RC
-RC
-TC
-TC
-RC
-RC
-RC
-RC
-TC
-TC
-DC
-DC
-DA
-DC
-AB
-AC
-DC
-DC
-DA
-AB
-AC
-DC
721
512
719
719
719
719
721
512
719
719
719
719
EZ
EZ
EZ
EZ
EZ
EZ
EZ
EZ
EZ
EZ
EZ
EZ
24 V AC 100 - 240 V AC 12 V DC 24 V CD
7 VA 10 VA 3.5 W 3.5 W
8 8 12 12 12 12 12 12 12 12 12 12
2 2 4 4 - - 4 4 4 4 4 4
4T 4T 6R 6R 6R 6R 6R 6R 6R 6R 6R 8T
- - - - - - - - - - - -
Yes / Yes -/- Yes / Yes -/- Yes / Yes -/- Yes / Yes -/- Yes / Yes -/- Yes / Yes -/-
Yes / Yes Yes / Yes Yes / Yes Yes / Yes Yes / Yes Yes / Yes Yes / Yes Yes / Yes Yes / Yes Yes / Yes Yes / Yes Yes / Yes
IP 20
- 25 °C ... + 55 °C
- 40 °C ... + 70 °C
107.5 x 90 x 58 mm
11
EZ819-AC-RC EZ822-DC-TC EZD-80-B EZD-CP4
X
-RC
-RC
-RC
-TC
-TC
-RC
-RC
-RC
-TC
-TC
-DC
-DC
-AC
-DC
-DC
Type
-DC
-DC
-AC
-DC
-DC
821
822
819
819
820
821
822
819
819
820
EZ
EZ
EZ
EZ
EZ
EZ
EZ
EZ
EZ
EZ
Supply voltage 100 - 240 V AC 24 V DC
Inputs, digital 12 12 12 12 12 12 12 12 12 12
Outputs, analog 0 - 10 V - - - - 1 1 - - 1 1
LCD display / keypad Yes / Yes -/- Yes / Yes -/- Yes / Yes -/- Yes / Yes -/- Yes / Yes -/-
7-day / year time switch Yes / Yes Yes / Yes Yes / Yes Yes / Yes Yes / Yes Yes / Yes Yes / Yes Yes / Yes Yes / Yes Yes / Yes
Short-circuit proof with power factor 0.7... 0.7 Line protection 816, 900 A - - - -
Degree of protection IP 20
Dimensions (W x H x D) mm 107.5 x 90 x 72 mm
[1] Relay = 8 A (10 A to UL) with resistive load, 3 A with inductive load/transistor outputs = 0.5 A / 24 V DC, max 4 outputs switchable in parallel.
[2] With backlight in continuous operation - 10 °C ... 0 °C.
[3] In stand-alone operation the EZD-...CP8-... CPU slices can also be mounted on a DIN 50022 top-hat rail, 35 mm or as screw mounting with EZB4-101-GF1 fixing brackets.
12
EZD-CP8-NT EZD-R16 EZD-TA17
EZD
Power supply/
Display Power supply / CPU Inputs / outputs
Coupling
ME
NT
500
800
ME
NT
16
P8-
7
P8-
0-B
16
16
A1
C-R
A1
0
P8-
P8-
P4-
P4-
D-8
D-R
C-C
D-T
C-C
D-8
D-T
D-R
D-A
D-C
D-C
D-C
D-C
EZ
EZ
D-A
EZ
D-A
EZ
EZ
EZ
EZ
EZ
EZ
EZ
EZ
EZ
EZ
Supply via ...-CP… 24 V DC 100 - 240 V AC Supply via …-CP8-..
- - - - - - - - 12 12 12 12 12
- - - - - - - - - 4 4 4 4
- - - - - - - - 4R 4R 4R 4R 4R
- - - - - - - - - - 1 - 1
Yes / Yes Yes / Yes -/- -/- -/- -/- -/- -/- -/- -/- -/- -/- -/-
-/- -/- -/- -/- Yes / Yes Yes / Yes Yes / Yes Yes / Yes -/- -/- -/- -/- -/-
- - - - - - - - 8A 8A 8A 0.5 A 0.5 A
0.2 - 2.5 mm2 (AWG 22-12), flexible 0.2 - 2.5 mm2 (AWG 22-12), flexible
IP 65 IP 20
Clearly legible at
- 5 °C ...+ 50 °C [2]" - 25 °C ... + 55 °C
- 40 °C ... + 70 °C
13
EZ618-DC-RE EZ202-RE EZ204-DP EZ205-ASI
ASI 221598
-RE
-RE
-TE
DN 233540
CO 233539
DP 212316
RE 232186
EASY202-
EASY618-
EASY618-
EASY620-
EASY200-
EASY204-
EASY205-
EASY221-
EASY222-
I
-DN
-CO
-DP
-RE
-EZ
-AS
212314
232112
212313
212315
AC-RE
DC-RE
DC-TE
EASY
-DC
-AC
-DC
200
202
204
221
222
205
Type
620
618
618
EZ
EZ
EZ
EZ
EZ
EZ
EZ
EZ
EZ
Heat dissipation 1W 10 VA 4W 1W 2W 1W 1W 1W
Inputs, digital - 12 12 12 - - - - -
Outputs. anllog 0 - 10 V - - - - - - - - -
Short-circuit proof with power factor 0.7... Line protection B16, 900 A - - - - -
Connection cables 0.2 - 4.0 mm2 (AWG 22-12), solid 0.2 - 4.0 mm2 (AWG 22-12),
0.2 - 2.5 mm2 (AWG 22-12), flexible solid 0.2 - 2.5 mm2 (AWG 22-12), flexible
Degree of protection IP 20 IP 20
RFI suppression EN 55011, EN 55022 Class B, IEC 61000-6-1, 2, 3, 4 EN 55011, EN 55022 Class B, IEC 61000-6-1, 2, 3, 4
Certification, standards EN 50178, IEC/EN 60947, UL, CSA EN 50178, IEC/EN 60947, UL, CSA
14
EZ221-CO EZ222-DN EZ200-POW EZ400-POW
Switched-mode
Accessories
power supply units
Application
EASY200-
EASY400-
W
W
229424
212319
-PO
-PO
POW
POW
Type
200
400
EZ
EZ
Supply voltage 100 - 240 V AC
Degree of protection IP 20
15
EZSoft the user-friendly
circuit diagram editor
EZSoft makes things particularly The integrated offline simulation
easy for users. The graphical tool allows users to test the
editor shows the circuit diagram functionality of the circuit
immediately in the display format diagram before commissioning,
required. Selection menus and without the need for a con-
drag & drop functions simplify nected device. The comment
circuit diagram creation. Simply function for contacts, coils and
select contacts and coils and function blocks helps provide a
connect with the mouse – clear overview of the circuit
that's it! diagram. A cover sheet with a
In addition to the editing customized company logo and
functions, the scaled software different text fields, as well as
packages EZSoftBasic and the cross-reference list with
EZSoft are available for comments, can turn printouts
straightforward circuit diagram into the perfect documentation
input. All software includes for applications.
user-friendly menus and Help
screens. EZ is maintenance-free
EZSoft offers the following The finished program is
display formats for viewing, stored in EZ's non-volatile
editing and printing out your memory until modified.
program: Additional auxiliary power or
batteries are not required. The
• IEC format, with contact intelligent relays are entirely
and coil symbols using maintenance-free.
international standards
Circuit diagrams and parameters
• EZ circuit diagram, same as are saved in the event of a
what is seen when program- power failure. If a power failure
ming from the EZ front panel occurs, the EZ controller
• ANSI format, in compliance stores switch positions and
with American standards values such as operating
hours, meters, counters and
EZSoft supports users who are
timing relays. When power is
configuring, programming and
restored the values are
defining parameters for EZ
restored. This retentive feature
intelligent relays and creating
for the different function
visualization functions for EZD
blocks and data is available on
displays. When intelligent relays
all EZ intelligent relay models.
are connected to EZ-NET, all
connected devices can be
accessed and their programs
loaded from a single intelligent
relay.
16
17
Eaton’s electrical business is a global leader in
electrical control, power distribution, and industrial
automation products and services. Through advanced
product development, world-class manufacturing
methods, and global engineering services and
support, Eaton’s electrical business provides
customer-driven solutions under brand names such
as Cutler-Hammer , Powerware, Durant , Heinemann ,
® ® ® ®