0% found this document useful (0 votes)
144 views

Lumel Current Transformers

This document provides an overview of low-voltage current transformers produced by Lumel, including their specifications, features, and applications. It describes Lumel's various current transformer series for different primary current ranges and busbar/conductor dimensions. These include wound primary series, round conductor series, and various busbar series with primary currents ranging from 1A to 1600A for classes 0.2, 0.5, and 1 accuracy. The document also lists accessories available for the current transformers.

Uploaded by

Mihai Buzz
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
144 views

Lumel Current Transformers

This document provides an overview of low-voltage current transformers produced by Lumel, including their specifications, features, and applications. It describes Lumel's various current transformer series for different primary current ranges and busbar/conductor dimensions. These include wound primary series, round conductor series, and various busbar series with primary currents ranging from 1A to 1600A for classes 0.2, 0.5, and 1 accuracy. The document also lists accessories available for the current transformers.

Uploaded by

Mihai Buzz
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 32

LOW-VOLTAGE

CURRENT TRANSFORMERS

1
ABOUT US

EX
PER
IEN
CE
DE
VE
LO
P ME
NT
PO
WE
R
EN
VIR
ON
ME
NT
PEO
PLE

P LE
P EO
T
EN
O NM
VIR
EN
W ER For over sixty years we have been providing you with all what you need,
PO working in accordance with the highest standards. Every day thousands of our clients
E NT all over the world get our safe and user-friendly products. It wouldn’t be possible
PM
V ELO without power and skills of our best specialists. We remember about every single detail
DE b e c a u s e
C E
R IEN
PE
EX

2 www.lumel.com.pl
CONTENTS

Current transformers summary...................................................................................4


General overview of current transformers..................................................................5
Instrument security factor.............................................................................................7
LCTM - wound primary series..................................................................................11
LCTR - round conductor series................................................................................13
LCTB 45 - busbar series.............................................................................................14
LCTB 50 - busbar series..............................................................................................15
LCTB 62 - busbar series..............................................................................................17
LCTB 74 - busbar series..............................................................................................19
LCTB 86 - busbar series.............................................................................................21
LCTB 100 - busbar series...........................................................................................22
LCTB 104 - busbar series...........................................................................................23
LCTB 140 - busbar series..........................................................................................24
LCTB 225 - busbar series............................................................................................26
LCTS - split core..........................................................................................................27
LCTP - 3-phase current transformers.........................................................................27 NEW

Accessories...........................................................................................................30

 DISPATCH WITHIN 48H:


In Stock check our stock at: www.lumel.com.pl

3
CURRENT TRANSFORMERS SUMMARY
Range of primary currents
Class 0.2S Class 0.2 Class 0.5S Class 0.5 Class 1

Page no.
Busbar Transformer
dimensions type min max min max min max min max min max

Wound primary series


N/A LCTM 62/W(40) 11 - - 1A 30 A - - 1A 30 A 1A 30 A
N/A LCTM 74/W(40) 11 - - 1A 60 A - - 1A 60 A 1A 60 A
Current transformers with window for round cunductor or busbar
Ø 14 LCTR 45/14(40) 13 - - - - - - 80 A 300 A 30 A 300 A
Ø 14 LCTR 50/14(30) 13 - - - - - - 100 A 300 A 40 A 300 A
Ø 14 LCTR 50/14(50) 13 - - - - - - 50 A 300 A 30 A 300 A
Ø 22 LCTR 62/R(40) 13 - - 100 A 600 A - - 75 A 600 A 50 A 600 A
Ø 20 / 20 x 10 LCTB 45/21(40) 14 - - - - - - 80 A 400 A 50 A 400 A
Ø 21 / 20 x 10 LCTB 50/21(30) 15 - - - - - - 80 A 400 A 40 A 400 A
Ø 26 / 30 x 10 LCTB 50/30(30) 15 - - - - - - 100 A 600 A 75 A 600 A
Ø 21 / 20 x 10 LCTB 50/21(50) 15 - - - - - - 50 A 400 A 50 A 400 A
Ø 26 / 30 x 10 LCTB 50/30(50) 15 - - - - - - 100 A 600 A 50 A 600 A
20 x 12 LCTB 62/20(40) 17 100 A 400 A 100 A 400 A 100 A 400 A 75 A 400 A 50 A 400 A
Ø 30 / 30 x 10 LCTB 62/30(40) 17 100 A 800 A 100 A 800 A 100 A 800 A 100 A 800 A 50 A 800 A
Ø 28 / 30 x 10 LCTB 62/30(50) 17 100 A 800 A 100 A 800 A 100 A 800 A 75 A 800 A 40 A 800 A
Ø 31 / 40 x 10 LCTB 62/40(40) 17 200 A 800 A 200 A 800 A 200 A 800 A 200 A 800 A 100 A 800 A
Ø 20 / 20 x 10 LCTB 74/20(45) 19 100 A 400 A 100 A 400 A 100 A 400 A 75 A 400 A 30 A 400 A
Ø 26 / 30 x 15 LCTB 74/30(45) 19 100 A 800 A 100 A 800 A 100 A 800 A 75 A 800 A 30 A 800 A
Ø 35 / 40 x 12 LCTB 74/40(45) 19 200 A 1000 A 200 A 1000 A 200 A 1000 A 100 A 1000 A 40 A 1000 A
Ø 41 / 50 x 12 LCTB 74/50(45) 19 250 A 1000 A 250 A 1000 A 250 A 1000 A 200 A 1000 A 100 A 1000 A
Ø 36 / 40 x 10 LCTB 86/40(45) 21 100 A 1000 A 100 A 1000 A 100 A 1000 A 100 A 1000 A 50 A 1000 A
Ø 46 / 50 x 12 LCTB 86/50(45) 21 300 A 1250 A 300 A 1250 A 300 A 1250 A 120 A 1250 A 100 A 1250 A
Ø 51 / 60 x 12 LCTB 86/60(45) 21 300 A 1600 A 300 A 1600 A 300 A 1600 A 200 A 1600 A 100 A 1600 A
Ø 54 / 60 x 12 LCTB 104/60(45) 23 300 A 1600 A 250 A 1600 A 300 A 1600 A 150 A 1600 A 100 A 1600 A
Ø 65 / 80 x 12 LCTB 104/80(45) 23 750 A 2000 A 400 A 2000 A 750 A 2000 A 250 A 2000A 200 A 2000 A
Ø 72 / 80 x30 LCTB 140/80(45) 24 500 A 2000 A 300 A 2000 A 500 A 2000 A 200 A 2000 A 200 A 2000 A
Ø 86/ 100 x 30 LCTB 140/100H(45) 24 600 A 4000 A 400 A 4000 A 600 A 4000 A 200 A 4000 A 200 A 4000 A
124 x 93 LCTB 225/125(50) 26 1000 A 6000 A 600 A 6000 A 1000 A 6000 A 600 A 6000 A 600 A 6000 A
166 x 65 LCTB 225/167(50) 26 1500 A 7500 A 1000 A 7500 A 1500 A 7500 A 1000 A 7500 A 1000 A 7500 A
Current transformers with vertical window for busbar or round cunductor
41 x 103 LCTB 100/100V(45) 22 1200 A 2500 A 1000 A 2500 A 1200 A 2500 A 400 A 2500 A 400 A 2500 A
38 x 128 LCTB 100/130V(45) 22 NA NA 1500 A 3000 A NA NA 400 A 3000 A 400 A 3000 A
Ø 86 / 100 x 30 LCTB 140/100V(45) 24 600 A 3000 A 400 A 3000 A 600 A 3000 A 200 A 3000 A 200 A 3000 A
70 x 130 LCTB 140/130V(45) 24 NA NA 1000 A 5000 A NA NA 400 A 5000 A 400 A 5000 A
Split core series
23 x 33 LCTS 93/30SC(40) 27 NA NA NA NA NA NA 300 A 400 A 100 A 400 A
85 x 54 LCTS 125/50SC(40) 27 NA NA NA NA NA NA 250 A 1000 A 250 A 1000 A
85 x 125 LCTS 155/80SC(40) 27 NA NA NA NA NA NA 250 A 3000 A 250 A 3000 A
82 x 162 LCTS 195/80SC(64) 27 NA NA NA NA NA NA 500 A 5000 A 500 A 5000 A
3-phase current transformers NEW

20 x 10 LCTP 75/ 15 (60) 28 NA NA NA NA NA NA 150 160 100 160


20 x 10 LCTP 105/ 21 (40) 28 NA NA NA NA NA NA 160 250 100 250
30 x 15 LCTP 140/ 31 (40) 28 NA NA NA NA NA NA 250 630 250 630
N/A LCTP 185/ 27 (45) 29 NA NA NA NA NA NA NA NA 100 500
N/A LCTP 185/ 37 (45) 29 NA NA NA NA NA NA NA NA 300 800

4 www.lumel.com.pl
GENERAL OVERVIEW OF CURRENT TRANSFORMERS

CURRENT TRANSFORMER is used for measurement of electric alternating


currents. When current in a circuit (primary current) is too high to directly apply
to measuring instruments, a current transformer produces a reduced current
(secondary current) accurately proportional to the current in the circuit, which can
be conveniently connected to measuring and recording instruments. A current trans-
former also isolates the measuring instruments from what may be very high voltage
in the monitored circuit.
Relationship between primary and secondary currents is called
rated transformation ratio.

N2
I1 = I2 .
N1
where: I1 - primary current, I2 - secondary current, N1 - number of turns of primary winding, N2 - number of turns of secondary winding, N2/N1 - rated transformation ratio
Current transformers are used mainly in such a way that the cable from the measured shock or bus current passes through the main hole transformer,
which is equivalent to one coil primary winding. In this case, the above equation simplifies to:

I1 = I2 . N2
The task is to reduce the transformer output current for currents of over 120% of measurement range, to protect against destruction of measuring devices connected
to the transformer in case of surges or failures in the primary circuit.

FEATURES:
• Wide range of accuracy classes: 0.2S, 0.2, 0.5S, 0.5, 1
• Wide range of supported primary currents, the dimensions of rails, the length of casing and hole diameters.
• Multiple mounting methods, including wall mounting, DIN rail 35mm, the conductor, a current bar.
• Shields designed to seal connections.

GENERAL SPECIFICATION
Applicable standard: IEC 61869-1/2
Case: 10% glass filled polycarbonate, flame retardant grades classified UL 94V-0
Connection: Two connection on each side. M4 screws with self lifting clamp strap.
Insulation class E (120°C max)
Maximum system voltage: 0.72 kV
Operating frequency: 50/60 Hz
Rated primary rating: 1 A…7500 A
Rated secondary output: 5 A or 1 A (for LCTP 3-phase current transformers only 5 A)
Rated burden: 1, 1.25, 1.5, 2.5, 3.75, 5, 7.5, 10, 12.5, 15, 20, 30, 45, 60, 100 VA
Accuracy class: 0.2, 0.2S, 0.5S – for laboratory and power measurement
0.5 – for accurate measuring
1 – for general measurement, for analog meters
Ambient temperature: -20°C …+45°C
Storage temperature: -50°C…+80°C
Thermal short circuit current (Ith): 40 x In for wound type
60 x In for bus bar type
Dynamic short circuit current (Idyn): 2.5xIth
Instrument security factor (FS): 2.5, 5, 10

DEMAND FOR POWER MEASURING DEVICES:


CT users expect these devices fulfill two basic conditions:
• a high degree of accuracy in the nominal current,
• security functions with overloads.

In order to fulfill these stipulations it is necessary for the power of a current transformer offered to fully achieve the actual power requirements of the measurement setup.
In ascertaining the actual power requirements, consideration is to be made not only of the loss of power of the appliances to be connected up, but also the losses incurred
by the instrument leads.
FEATURES: OUTPUTS:
Class
5A

GENERAL OVERVIEW 5
GENERAL OVERVIEW OF CURRENT TRANSFORMERS
Power requirements for measuring apparatur and relays:
• Analog moving-iron meters 0.7 – 1.5VA
• Rectifier current meters 0.001 – 0.250 VA CONNECTION DIAGRAMM
• Multi-range current meters 0.005 – 5.000 VA OF CURRENT TRANSFORMERS
• Current recorders 0.300-9.000 VA
• Bimmetalic ammeters 2.5 – 3.0 VA
• Power meter 0.2 – 5.0 VA
• Power factor meter 2.0 – 6.0 VA IP
• Meters 0.4 – 1.0 VA
IS
• Relays 0.2 – 6.0 VA P1
• Power transducers 0.5 VA A
• Energy meters 2.5 VA

Internal losses of copper wiring: P2


Where:
I – Secondary nominal current,
I2 x 2 L L – Distance in [m],
P= [VA] qCU – wire cross-section in [mm2].
qCU x 56

Table for values appertaining to 5 A


qcu 1m 2m 3m 4m 5m 6m 7m 8m 9m 10 m
2.5 mm2 0.36 0.71 1.07 1.43 1.78 2.14 2.50 2.86 3.21 3.57
4.0 mm2 0.22 0.45 0.67 0.89 1.12 1.34 1.56 1.79 2.01 2.24
6.0 mm2 0.15 0.30 0.45 0.60 0.74 0.89 1.04 1.19 1.34 1.49
10.0 mm2 0.09 0.18 0.27 0.36 0.44 0.54 0.63 0.71 0.80 0.89

Table for values appertaining to 1 A


qcu 10 m 20 m 30 m 40 m 50 m 60 m 70 m 80 m 90 m 100 m
1.0 mm2 0.36 0.71 1.07 1.43 1.78 2.14 2.50 2.86 3.21 3.57
2.5 mm2 0.14 0.29 0.43 0.57 0.72 0.86 1.00 1.14 1.29 1.43
4.0 mm2 0.09 0.18 0.27 0.36 0.45 0.54 0.63 0.71 0.80 0.89
6.0 mm2 0.06 0.12 0.18 0.24 0.30 0.36 0.42 0.48 0.54 0.60
10.0 mm2 0.04 0.07 0.11 0.14 0.18 0.21 0.25 0.29 0.32 0.36

6 www.lumel.com.pl
LCTM - wound primary series LCTR -round conductor series LCTB - busbar series

Transformer type
LCTR 62/R (40)

LCTM 74W (45)

LCTM 62/W (40)


LCTR 45/14 (40)
LCTR 50/14 (30)
LCTR 50/14 (50)
LCTB 45/21 (40)
LCTB 50/21 (30)
LCTB 50/30 (30)
LCTB 50/21 (50)
LCTB 50/30 (50)
LCTB 62/20 (40)
LCTB 62/40 (40)
LCTB 62/30 (50)

LCTB 62/30 (40)


Class 0.2 0.5 1 0.2 0.5 1 0.5 1 0.5 1 0.5 1 0.2 0.5S 0.5 1 0.5 1 0.5 1 0.5 1 0.5 1 0.5 1 0.2S 0.2 0.5S 0.5 1 0.2S 0.2 0.5S 0.5 1 0.2S 0.2 0.5S 0.5 1 0.2S 0.2 0.5S 0.5 1

Range
[A] Instrument security factor (FS)
1 15 10 5 15 10 5
2.5 15 10 5 15 10 5
5 15 10 5 15 10 5
7.5 15 10 5 15 10 5
10 15 10 5 15 10 5
15 15 10 5 15 10 5
20 15 10 5 15 10 5
25 15 10 5 15 10 5
30 15 10 5 15 10 5 5 5
40 15 10 5 5 5 5 5
50 15 10 5 5 5 5 5 5 5 5 10 5 5 5 5
60 15 10 5 5 5 5 5 5 5 5 10 5 5 5 5
75 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5
80 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5
100 5 5 5 5 5 5 10 5 5 5 5 5 5 5 5 5 5 5 5 5 10 5 5 5 5 10 5 5 5 5 5 15 5 5 5
120 5 5 5 5 5 5 10 5 5 5 5 5 5 5 5 5 5 5 5 5 10 5 5 5 5 10 5 5 5 5 5 15 5 5 5

INSTRUMENT SECURITY VIEW


125 5 5 5 5 5 5 10 5 5 5 5 5 5 5 5 5 5 5 5 5 10 5 5 5 5 10 5 5 5 5 5 15 5 5 5
150 5 5 5 5 5 5 10 5 5 5 5 5 5 5 5 5 5 5 5 5 5 10 5 5 5 5 10 5 5 5 5 5 10 5 5 5
200 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 10 5 5 5 5 10 5 5 5 5 10 5 5 5
250 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 10 5 5 5 5 10 5 5 5 5 10 5 5 5
300 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 10 5 5 5 5 10 5 5 5 5 10 5 5 5
400 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 10 5 5 5 5 10 5 5 5 5 10 5 5 5
500 5 5 5 5 5 5 5 10 5 10 5 5 5 5 5 5 5 10 10 10 5 5
600 5 5 5 5 5 5 5 10 5 10 5 5 5 5 5 5 5 10 10 10 5 5
750 10 5 10 5 5 5 5 5 5 5 10 10 10 5 5
800 10 5 10 5 5 5 5 5 5 5 10 10 10 5 5

7
INSTRUMENT SECURITY FACTOR
8
LCTB - busbar series

Transformer type
LCTB 74/20 (45)
LCTB 74/30 (45)
LCTB 74/40 (45)
LCTB 74/50 (45)
LCTB 86/40 (45)
LCTB 86/50 (45)
LCTB 86/60 (45)

Class 0.2S 0.2 0.5S 0.5 1 0.2S 0.2 0.5S 0.5 1 0.2S 0.2 0.5S 0.5 1 0.2S 0.2 0.5S 0.5 1 0.2S 0.2 0.5S 0.5 1 0.2S 0.2 0.5S 0.5 1 0.2S 0.2 0.5S 0.5 1
Range
[A] Instrument security factor (FS)
30 10 10
40 10 10 5
50 10 10 5 5
60 5 5 5 5
75 15 5 10 5 5 5
80 15 5 10 5 5 5
100 5 15 5 10 5 5 15 5 10 5 10 5 5 5 10 5 10 5 5 5
120 5 15 5 10 5 5 15 5 10 5 10 5 5 5 10 5 10 5 10 5 5
125 5 15 5 10 5 5 15 5 10 5 10 5 5 5 10 5 10 5 10 5 5
INSTRUMENT SECURITY FACTOR

150 5 15 5 10 5 5 15 5 5 5 5 5 5 5 10 5 10 5 5 5 5
200 5 10 5 5 5 5 15 5 5 5 5 10 5 5 5 5 5 5 10 5 10 5 5 5 5 5
250 5 10 5 5 5 5 10 5 5 5 5 10 5 5 5 5 10 5 5 5 5 10 5 5 5 5 5 5 5

www.lumel.com.pl
300 5 10 5 5 5 5 10 5 5 5 5 5 5 5 5 5 10 5 5 5 5 10 5 5 5 5 10 5 5 5 5 10 5 5 5
400 5 10 5 5 5 10 10 10 5 5 5 5 5 5 5 5 5 5 5 5 15 10 15 5 5 5 10 5 5 5 5 10 5 5 5
500 10 10 10 5 5 5 5 5 5 5 5 5 5 5 5 15 5 15 5 5 5 10 5 5 5 5 10 5 5 5
600 10 10 10 5 5 10 5 10 5 5 5 5 5 5 5 10 5 10 5 5 5 10 5 5 5 10 10 10 5 5
750 10 10 10 5 5 10 5 10 5 5 5 5 5 5 5 10 5 10 5 5 10 10 10 5 5 10 5 10 5 5
800 10 10 10 5 5 5 5 5 5 5 5 5 5 5 5 10 5 10 5 5 10 5 10 5 5 10 5 10 5 5
1000 5 5 5 5 5 5 5 5 5 5 10 5 10 5 5 5 5 5 5 5 10 5 10 5 5
1200 5 5 5 5 5 10 5 10 5 5
1250 5 5 5 5 5 10 5 10 5 5
1500 5 5 5 5 5
1600 5 5 5 5 5
LCTB - busbar series

Transformer type
LCTB104/60 (45)
LCTB 104/80 (45)
LCTB 140/80 (45)

LCTB 100/100V (45)


LCTB 100/130V (45)
LCTB 140/100V (45)
LCTB 140/130V (45)

LCTB 140/100H (45)


Class 0.2S 0.2 0.5S 0.5 1 0.2 0.5 1 0.2S 0.2 0.5S 0.5 1 0.2S 0.2 0.5S 0.5 1 0.2S 0.2 0.5S 0.5 1 0.2S 0.2 0.5S 0.5 1 0.2S 0.2 0.5S 0.5 1 0.2 0.5 1
Range
[A] Instrument security factor (FS)
100 10
120 10
125 10
150 10 5
200 10 5 5 10 5 10 5 10 5
250 15 5 5 10 5 5 5 10 5 10 5
300 15 15 15 5 5 10 5 15 5 5 10 5 10 5
400 10 5 10 5 15 15 15 5 5 10 5 5 15 5 5 15 10 5 15 10 5 10 10
500 10 5 10 5 15 10 15 5 5 10 5 5 15 15 15 5 5 15 10 5 15 10 5 10 10
600 10 5 10 5 15 10 15 5 5 10 5 5 15 10 15 5 5 15 15 15 5 5 15 15 15 5 5 10 10
750 10 5 10 5 15 10 15 5 5 10 10 10 5 5 15 10 15 5 5 15 15 15 5 5 15 15 15 5 5 10 10
800 10 5 10 5 15 10 15 5 5 10 5 10 5 5 15 10 15 5 5 10 10 10 5 5 10 10 10 5 5 10 10
1000 10 5 5 5 5 10 5 10 5 5 10 5 10 5 5 10 10 10 5 5 10 5 10 5 5 10 5 10 5 5 10 10 10

INSTRUMENT SECURITY VIEW


1200 10 10 10 5 5 5 5 10 5 10 5 5 5 5 5 5 5 10 10 10 5 5 5 5 5 5 5 5 5 5 5 5 10 10 10
1250 10 10 10 5 5 5 5 10 5 10 5 5 5 5 5 5 5 10 5 10 5 5 5 5 5 5 5 5 5 5 5 5 10 10 10
1500 10 10 10 5 5 10 5 5 10 5 10 5 5 5 5 5 5 5 10 5 10 5 5 5 5 5 5 5 5 5 5 5 5 10 10 10
1600 10 10 10 5 5 10 5 5 10 5 10 5 5 5 5 5 5 5 10 5 10 5 5 5 5 5 5 5 5 5 5 5 5 10 10 10
2000 10 10 10 5 5 10 5 5 5 5 5 5 5 10 5 10 5 5 5 5 5 5 5 5 5 5 5 5 10 10 10
2500 10 10 10 10 5 10 10 5 5 5 5 5 5 5 5 5 5 5 10 10 10
3000 10 10 10 5 5 5 5 5 5 5 5 5 5 10 10 10
3200 10 10 10 5 5 5 5 5 10 10 10
4000 5 5 5 5 5 15 10 10
5000 15 15 15

9
INSTRUMENT SECURITY FACTOR
W
NE

LCTP -

10
LCTB - busbar series LCTS - split core series LCTP- busbar series round conduc-
tor series

Transformer type
LCTP 75/15 (60)
LCTP 105/21 (40)
LCTP 140/31 (40)
LCTP 185/27 (45)
LCTP 185/37 (45)

LCTS 93/30SC (40)

LCTB 225/125 (50)


LCTB 225/167 (50)
LCTS 125/50SC (40)
LCTS 155/80SC (40)
LCTS 195/80SC (64)
Class 0.2S 0.2 0.5S 0.5 1 0.2S 0.2 0.5S 0.5 1 0.5 1 3 0.5 1 0.5 1 0.5 1 0.5 1 0.5 1 0.5 1 1 1
Range [A] Instrument security factor (FS)
100 10 10 5 5 5
125 5 5
150 10 10 5 5 5 10
160 5 5 5 5
200 10 10 5 5 10
250 10 10 10 10 10 10 5 5 5 5 5
300 10 10 10 10 10 10 10 5 5 5 5
400 10 10 10 10 10 10 10 5 5 5 5
500 10 10 10 10 30 30 5 5 5 5
600 10 10 10 10 10 10 10 30 30 5 5 5
630 5 5
INSTRUMENT SECURITY FACTOR

750 10 10 10 10 10 10 10 30 30
800 10 10 10 10 10 10 10 30 30 5
1000 10 10 10 10 10 10 10 10 10 10 10 10 30 30

www.lumel.com.pl
1200 10 10 10 10 10 10 10 10 10 10 10 10 30 30
1250 10 10 10 10 10 10 10 10 10 10 10 10 30 30
1500 10 10 10 10 5 10 10 10 10 5 10 10 10 10 30 30
1600 10 10 10 10 5 10 10 10 10 5 10 10 10 10 30 30
2000 10 10 10 10 5 10 10 10 10 5 10 10 10 10 30 30
2500 10 10 10 10 5 10 10 10 10 5 10 10 30 30
3000 10 10 10 10 5 10 10 10 10 5 10 10 30 30
3200 10 10 10 10 5
4000 10 10 10 10 5 15 10 15 10 10 30 30
5000 15 15 15 5 5 15 10 15 10 10 30 30
6000 15 15 15 5 5 15 10 15 10 10
7500 15 15 15 10 10
WOUND PRIMARY SERIES - LCTM

LCTM 62/W (40) LCTM 74/W (45) INPUT:


Depth 40 mm 45 mm

Width 62 mm 74 mm

Primary current 1 A...30 A 1 A...60 A


OUTPUTS:
Secondary current 1 A, 5 A
5A
Accuracy class 0.2; 0.5; 1

DIMENSIONS

LCTM 62/W (40) LCTM 74/W (45)

Transformer type LCTM 62/W (40) LCTM 74/W (45)


Accuracy class 0.2 0.5 1 0.2 0.5 1
Rated primary current Transformer burden
1A 1 VA 2.5 VA 5 VA 1.5 VA 5 VA 10 VA
2.5 A 1 VA 2.5 VA 5 VA 1.5 VA 5 VA 10 VA
5A 1 VA 2.5 VA 5 VA 1.5 VA 5 VA 10 VA
7.5 A 1 VA 2.5 VA 5 VA 1.5 VA 5 VA 10 VA
10 A 1 VA 2.5 VA 5 VA 1.5 VA 5 VA 10 VA
15 A 1 VA 2.5 VA 5 VA 1.5 VA 5 VA 10 VA
20 A 1 VA 2.5 VA 5 VA 1.5 VA 5 VA 10 VA
25 A 1 VA 2.5 VA 5 VA 1.5 VA 5 VA 10 VA
30 A 1 VA 2.5 VA 5 VA 1.5 VA 5 VA 10 VA
40 A - - - 1.5 VA 5 VA 10 VA
50 A - - - 1.5 VA 5 VA 10 VA
60 A - - - 1.5 VA 5 VA 10 VA
ORDER ACCESSORIES:
Required data: transformer type/primary current/secondary current/power/accuracy class DIN rail mounting base
Order example: LCTM 62/W (40) 25/5A, 5VA, cl. 1 order code: LH000-0904-130-124

LC T M S E R I E S 11
LCTR - ROUND CONDUCTOR SERIES

LCTR 45/14 (40) LCTR 50/14 (30) LCTR 50/14 (50) LCTR 62/R (40)

INPUT: Hole
diameter Ø 14 mm Ø 14 mm Ø 14 mm Ø 22 mm

Depth 40 mm 31 mm 51 mm 40 mm

Width 45 mm 50 mm 50 mm 62 mm

Primary 30 A...300 A 40 A...300 A 30 A...300 A 50 A...600 A


current
OUTPUTS: Secondary
current 1 A, 5 A

5A Accuracy
class 0.5; 1 0.2; 0.5S; 0.5; 1

DIMENSIONS

LCTR 45/14 (40) LCTR 50/14 (30)

Transformer type LCTR 45/14 (40) LCTR 50/14 (30)


Accuracy class 0.5 1 0.5 1
Rated primary current Transformer burden
30 A - 1 VA - -
40 A - 1 VA - 1 VA
50 A - 1.5 VA - 1.5 VA
60 A - 1.5 VA - 1.5 VA
75 A - 2.5 VA - 1.5 VA
80 A 1 VA 2.5 VA - 1.5 VA
100 A 1.5 VA 3.75 VA 2.5 VA 3.75 VA
120 A 1.5 VA 3.75 VA 2.5 VA 3.75 VA
125 A 2.5 VA 3.75 VA 2.5 VA 3.75 VA
150 A 2.5 VA 5 VA 3.75 VA 5 VA
200 A 3.75 VA 7.5 VA 3.75 VA 5 VA
250 A 5 VA 7.5 VA 5 VA 7.5 VA
300 A 5 VA 10 VA 7.5 VA 7.5 VA

 DISPATCH WITHIN 48H:


In Stock check our stock at: www.lumel.com.pl

12 www.lumel.com.pl
ROUND CONDUCTOR SERIES - LCTR

DIMENSIONS

LCTR 50/14 (50) LCTR 62/R (40)

Transformer type LCTR 50/14 (50) LCTR 62/R (40)


Accuracy class 0.5 1 0.2 0.5S 0.5 1
Rated primary current Transformer burden
30 A - 1 VA - - - -
40 A - 1 VA - - - -
50 A 1.5 VA 1.5 VA - - - 1.5 VA
60 A 1.5 VA 1.5 VA - - - 2.5 VA
75 A 2.5 VA 5 VA - - 1.5 VA 2.5 VA
80 A 2.5 VA 5 VA - - 2.5 VA 2.5 VA
100 A 3.75 VA 5 VA 1.5 VA - 2.5 VA 5 VA
120 A 3.75 VA 5 VA 1.5 VA - 3.75 VA 5 VA
125 A 3.75 VA 5 VA 1.5 VA - 3.75 VA 5 VA
150 A 5 VA 7.5 VA 2.5 VA 2.5 VA 5 VA 5 VA 7.5 VA
200 A 7.5 VA 10 VA 5 VA 5 VA 5 VA 7.5 VA 5 VA 10 VA
250 A 10 VA 12.5 VA 5 VA 5 VA 10 VA 15 VA
300 A 10 VA 12.5 VA 5 VA 5 VA 10 VA 15 VA
400 A - - 7.5 VA 7.5 VA 15 VA 15 VA
500 A - - 10 VA - 15 VA 15 VA
600 A - - 10 VA - 15 VA 15 VA

ORDER
Required data: transformer type/ primary current/ secondary current/ power/ accuracy class
ACCESSORIES:
DIN rail mounting base  DISPATCH WITHIN 48H:
Order example: LCTR 50/14 (50) 100/5A, 5VA, cl. 1 - for details see page 25 In Stock check our stock at: www.lumel.com.pl

LC T R S E R I E S 13
LCTB 45 - BUSBAR SERIES

LCTB 45/21 (40)


Hole diameter Ø 20 mm

INPUT:
Busbar 20 x 10 mm

Depth 40 mm
Width 45 mm

Primary current 50 A...400 A


OUTPUTS:
Secondary current 1 A, 5 A
5A
Accuracy class 0,5; 1

DIMENSIONS

LCTB 45/21 (40)

Transformer type LCTB 45/21 (40)


Accuracy class 0.5 1
Rated primary current Transformer burden
50 A - 1.5 VA
60 A - 1.5 VA
75 A - 2.5 VA
80 A 1 VA 2.5 VA
100 A 1.5 VA 3.75 VA
ORDER
Required data: transformer type/ primary current/ secondary current/ power/ accuracy class
120 A 1.5 VA 3.75 VA Order example: LCTB 45/21 (40) 100/5A, 3.75VA, cl. 1
125 A 2.5 VA 3.75 VA
150 A 2.5 VA 5 VA ACCESSORIES:
200 A 3.75 VA 5 VA
DIN rail mounting base
order code: LH000-0904-130-002
250 A 3.75 VA 5 VA
300 A 5 VA 5 VA
 DISPATCH WITHIN 48H:
400 A 5 VA 5 VA In Stock check our stock at: www.lumel.com.pl

14 www.lumel.com.pl
BUSBAR SERIES - LCTB 50

LCTB 50/21 (30) LCTB 50/30 (30) LCTB 50/21 (50) LCTB 50/30 (50)
Hole
diameter Ø 21 mm Ø 26 mm Ø 21 mm Ø26 mm INPUT:
Busbar 20 x 10 mm 30 x 10 mm 20 x 10 mm 30 x 10 mm

Depth 31 mm 31 mm 51 mm 51 mm

Width 50 mm 50 mm 50 mm 50 mm
Primary
OUTPUTS:
current 40 A...400 A 75 A...600 A 50 A...400 A 50 A... 600 A

Secondary
current 1 A, 5 A 5A
Accuracy 0.5; 1
class

DIMENSIONS

LCTB 50/21 (30) LCTB 50/30 (30)

Transformer type LCTB 50/21 (30) LCTB 50/30 (30)


Accuracy class 0.5 1 0.5 1
Rated primary current Transformer burden
40 A - 1 VA - -
50 A - 1 VA - -
60 A - 1 VA - -
75 A - 1.5 VA - 1 VA
80 A 1 VA 2.5 VA - 1.5 VA
100 A 1.5 VA 2.5 VA 1 VA 2.5 VA
120 A 2.5 VA 2.5 VA 1 VA 2.5 VA
125 A 2.5 VA 3.75 VA 1 VA 2.5 VA
150 A 2.5 VA 5 VA 2.5 VA 3.75 VA
200 A 3.75 VA 5 VA 2.5 VA 5 VA
250 A 5 VA 5 VA 5 VA 5 VA
300 A 5 VA 7.5 VA 5 VA 5 VA
400 A 5 VA 7.5 VA 5 VA 5 VA 6.25 VA
500 A - - 5 VA 6.25 VA
600 A - - 5 VA 7.5 VA

 DISPATCH WITHIN 48H:


In Stock check our stock at: www.lumel.com.pl

LC T B S E R I E S 15
LCTB 50 - BUSBAR SERIES

DIMENSIONS

LCTB50/21 (50) LCTB 50/30 (50)

Transformer type LCTB 50/21 (50) LCTB 50/30 (50)


Accuracy class 0.5 1 0.5 1
Rated primary current Transformer burden
50 A 1 VA 2.5 VA - 1.5 VA
60 A 1 VA 2.5 VA - 1.5 VA
75 A 1.5 VA 2.5 VA - 2.5 VA
80 A 2.5 VA 5 VA - 2.5 VA
100 A 2.5 VA 5 VA 2.5 VA 5 VA
120 A 3.75 VA 5 VA 2.5 VA 5 VA
125 A 5 VA 5 VA 2.5 VA 5 VA
150 A 5 VA 10 VA 5 VA 5 VA
200 A 7.5 VA 10 VA 5 VA 7.5 VA
250 A 7.5 VA 10 VA 5 VA 10 VA
300 A 7.5 VA 12.5 VA 5 VA 10 VA
400 A 10 VA 15 VA 10 VA 12.5 VA
500 A - - 10 VA 12.5 VA
600 A - - 10 VA 15 VA

ORDER
Required data: transformer type/ primary current/ secondary current/ power/ accuracy class
ACCESSORIES:
DIN rail mounting base
 DISPATCH WITHIN 48H:
Order example: LCTB 50/21 (50) 100/5A, 5VA, cl. 1 - for details see page 25 In Stock check our stock at: www.lumel.com.pl

16 www.lumel.com.pl
BUSBAR SERIES - LCTB 62
LCTB 62/20 (40) LCTB 62/30 (40) LCTB 62/30 (50) LCTB 62/40 (40)
Hole - Ø 30 mm Ø 28 mm Ø 31 mm
diameter INPUT:
30x10 mm, 40x10 mm,
Busbar 20x12 mm 30x10 mm
2x25 x10 mm 2 x 30 x 10 mm
Depth 40 mm 40 mm 50 mm 40 mm

Width 62 mm 62 mm 62 mm 62 mm

Primary 50 A...400 A 50 A...800 A 40 A...800 A 100 A...800 A OUTPUTS:


current

Secondary
current 1 A, 5 A 5A
Accuracy 0.2S; 0.2; 0.5S; 0.5; 1
class

DIMENSIONS

LCTB 62/20 (40) LCTB 62/30 (40)

Transformer type LCTB 62/20 (40) LCTB 62/30 (40)


Accuracy class 0.2S 0.2 0.5S 0.5 1 0.2S 0.2 0.5S 0.5 1
Rated primary current Transformer burden
50 A - - - - 1.5 VA - - - - 1.5 VA
60 A - - - - 2.5 VA - - - - 1.5 VA
75 A - - - 1.5 VA 3.75 VA - - - - 1.5 VA
80 A - - - 2.5 VA 3.75 VA - - - - 2 VA
100 A 1.5 VA 1.5 VA 1.5 VA 2.5 VA 5 VA 1 VA 1 VA 1 VA 1.5 VA 2.5 VA
120 A 1.5 VA 1.5 VA 1.5 VA 3.75 VA 5 VA 1 VA 1 VA 1 VA 2.5 VA 3.75 VA
125 A 1.5 VA 1.5 VA 1.5 VA 3.75 VA 5 VA 1 VA 1 VA 1 VA 2.5 VA 3.75 VA
150 A 2 VA 2.5 VA 2.0 VA 5 VA 7.5 VA 2.5 VA 1.5 VA 2.5 VA 3.75 VA 5 VA
200 A 3.75 VA 5 VA 3.75 VA 7.5 VA 10 VA 5 VA 2.5 VA 5 VA 5 VA 7.5 VA
250 A 3.75 VA 5 VA 3.75 VA 10 VA 15 VA 5 VA 3.75 VA 5 VA 5 VA 10 VA
300 A 3.75 VA 5 VA 3.75 VA 10 VA 15 VA 5 VA 3.75 VA 5 VA 5 VA 10 VA
400 A 5 VA 7.5 VA 5 VA 15 VA 15 VA 5 VA 5 VA 5 VA 7.5 VA 12.5 VA
500 A - - - - - 5 VA 7.5 VA 5 VA 10 VA 12.5 VA
600 A - - - - - 10 VA 7.5 VA 10 VA 15 VA 15 VA

750 A - - - - - 10 VA 10 VA 10 VA 15 VA 15 VA
800 A - - - - - 10 VA 10 VA 10 VA 15 VA 15 VA

 DISPATCH WITHIN 48H:


In Stock check our stock at: www.lumel.com.pl

LC T B S E R I E S 17
LCTB 62 - BUSBAR SERIES

DIMENSIONS

LCTB 62/30 (50) LCTB 62/40 (40)

Transformer type LCTB 62/30 (50) LCTB 62/40 (40)

Accuracy class 0.2S 0.2 0.5S 0.5 1 0.2S 0.2 0.5S 0.5 1
Rated primary current Transformer burden
40 A - - - - 1 VA - - - - -
50 A - - - - 2.5 VA - - - - -
60 A - - - - 2.5 VA - - - - -
75 A - - - 2.5 VA 2.5 VA - - - - -
80 A - - - 2.5 VA 3.75 VA - - - - -
100 A 1.25 VA 1.25 VA 1.25 VA 5 VA 5 VA - - - - 1 VA
120 A 1.25 VA 1.25 VA 1.25 VA 5 VA 5 VA - - - - 1.5 VA
125 A 1.25 VA 1.25 VA 1.25 VA 5 VA 5 VA - - - - 1.5 VA
150 A 2 VA 2 VA 2 VA 5 VA 7.5 VA - - - 2.5 VA
200 A 5 VA 3.75 VA 5 VA 10 VA 15 VA 1 VA 1 VA 1 VA 1.5 VA 3.75 VA
250 A 5 VA 5 VA 5 VA 15 VA 15 VA 1.5 VA 1.5 VA 1.5 VA 2.5 VA 5 VA
300 A 5 VA 5 VA 5 VA 15 VA 15 VA 1.5 VA 1.5 VA 1.5 VA 5 VA 5 VA
400 A 10 VA 6.25VA 10 VA 15 VA 30 VA 2.5 VA 2.5 VA 2.5 VA 5 VA 5 VA
500 A 5 VA 7.5 VA 5 VA 15 VA 30 VA 3.75 VA 5 VA 3.75 VA 5 VA 5 VA 7.5 VA
600 A 6.25 VA 10 VA 6.25 VA 20 VA 30 VA 5 VA 7.5 VA 5 VA 7.5 VA 10 VA
750 A 6.25 VA 10 VA 6.25 VA 20 VA 30 VA 5 VA 10 VA 5 VA 10 VA 10 VA
800 A 6.25 VA 10 VA 6.25 VA 20 VA 30 VA 5 VA 10 VA 5 VA 10 VA 10 VA

ORDER
Required data: transformer type/ primary current/ secondary current/ power/ accuracy class
ACCESSORIES:
DIN rail mounting base
 DISPATCH WITHIN 48H:
Order example: LCTB 62/40 (40) 100/5A, 1VA, cl. 1 - for details see page 25 In Stock check our stock at: www.lumel.com.pl

18 www.lumel.com.pl
BUSBAR SERIES - LCTB 74
LCTB 74/20 (45) LCTB 74/30 (45) LCTB 74/40 (45) LCTB 74/50 (45)
Hole Ø 20 mm Ø26 mm Ø35 mm Ø 41 mm INPUT:
diameter
30x15 mm, 40x12 mm, 50x12 mm,
Busbar 20x10 mm
2x20x10 mm 2x30 x15 mm 2 x40x10 mm
Depth 45 mm 45 mm 45 mm 45 mm

Width 74 mm 74 mm 74 mm 74 mm
OUTPUTS:
Prąd 30 A...400 A 30 A...800 A 40 A...1000 A 100 A...1000 A
pierwotny

Secondary
5A
current 1 A, 5 A

Accuracy 0.2S; 0.2; 0.5S; 0.5; 1


class

DIMENSIONS

LCTB 74/20 (45) LCTB 74/30 (45)

Transformer type LCTB 74/20 (45) LCTB 74/30 (45)


Accuracy class 0.2S 0.2 0.5S 0.5 1 0.2S 0.2 0.5S 0.5 1
Rated primary current Transformer burden
30 A - - - - 1.5 VA - - - - 1 VA
40 A - - - - 1.5 VA - - - - 1.5 VA
50 A - - - - 2.5 VA - - - - 1.5 VA
60 A - - - - 3.75 VA - - - - 2.5 VA
75 A - - - 1.5 VA 5 VA - - - 1.5 VA 2.5 VA
80 A - - - 1.5 VA 5 VA - - - 1.5 VA 3.75 VA
100 A 1.5 VA 1.5 VA 1.5 VA 5 VA 7.5 VA 1.5 VA 1.5 VA 1.5 VA 2.5 VA 5 VA
120 A 1.5 VA 1.5 VA 1.5 VA 5 VA 10 VA 1.5 VA 1.5 VA 1.5 VA 2.5 VA 5 VA
125 A 1.5 VA 1.5 VA 1.5 VA 5 VA 10 VA 1.5 VA 1.5 VA 1.5 VA 2.5 VA 5 VA
150 A 2.5 VA 2.5 VA 2.5 VA 7.5 VA 12.5 VA 1.5 VA 1.5 VA 1.5 VA 5 VA 7.5 VA
200 A 5 VA 5 VA 5 VA 10 VA 15 VA 2.5 VA 2.5 VA 2.5 VA 10 VA 15 VA
250 A 5 VA 5 VA 5 VA 10 VA 15 VA 2.5 VA 2.5 VA 2.5 VA 10 VA 15 VA
300 A 5 VA 7.5 VA 5 VA 15 VA 15 VA 2.5 VA 5 VA 2.5 VA 10 VA 15 VA
400 A 5 VA 10 VA 5 VA 15 VA 20 VA 5 VA 7.5VA 5 VA 15 VA 20 VA
500 A - - - - - 5 VA 10 VA 5 VA 15 VA 20 VA
600 A - - - - - 5 VA 15 VA 5 VA 15 VA 20 VA
750 A - - - - - 7.5 VA 20 VA 7.5 VA 20 VA 30 VA
800 A - - - - - 10 VA 30 VA 10 VA 30 VA 30 VA

LC T B S E R I E S 19
LCTB 74 - BUSBAR SERIES
DIMENSIONS

LCTB 74/40 (45) LCTB 74/50 (45)

Transformer type LCTB 74/40 (45) LCTB 74/50 (45)


Accuracy class 0.2S 0.2 0.5S 0.5 1 0.2S 0.2 0.5S 0.5 1
Rated primary current Transformer burden
40 A - - - - 1 VA - - - - -
50 A - - - - 1 VA - - - - -
60 A - - - - 1 VA - - - - -
75 A - - - - 1.5 VA - - - - -
80 A - - - - 1.5 VA - - - - -
100 A - - - 1.5 VA 2.5 VA - - - - 1.5 VA
120 A - - - 1.5 VA 2.5 VA - - - - 1.5 VA
125 A - - - 1.5 VA 2.5 VA - - - - 1.5 VA
150 A - - - 2.5 VA 3.75 VA - - - - 2.5 VA
200 A 2.5 VA 2.5 VA 2.5 VA 3.75 VA 5 VA - - - 1.5 VA 3.75 VA
250 A 5 VA 2.5 VA 5 VA 5 VA 7.5 VA 1.5 VA 1.5 VA 1.5 VA 2.5 VA 5 VA
300 A 5 VA 2.5 VA 5 VA 5 VA 7.5 VA 1.5 VA 1.5 VA 1.5 VA 5 VA 7.5 VA
400 A 5 VA 5 VA 5 VA 5 VA 7.5 VA 12.5 VA 2.5 VA 2.5VA 2.5 VA 5 VA 7.5 VA
500 A 5 VA 7.5 VA 5 VA 10 VA 15 VA 5 VA 5 VA 5 VA 7.5 VA 10 VA
600 A 5 VA 10 VA 5 VA 15 VA 20 VA 5 VA 5 VA 7.5 VA 5 VA 10 VA 12.5 VA
750 A 5 VA 10 VA 5 VA 15 VA 20 VA 5 VA 10 VA 5 VA 12.5 VA 15 VA
800 A 7.5 VA 15 VA 7.5 VA 15 VA 20 VA 5 VA 10 VA 5 VA 12.5 VA 15 VA
1000 A 10 VA 15 VA 10 VA 15 VA 20 VA 5 VA 10 VA 5 VA 12.5 VA 15 VA

ORDER
Required data: transformer type/ primary current/ secondary current/ power/ accuracy class
ACCESSORIES:
DIN rail mounting base
 DISPATCH WITHIN 48H:
Order example: LCTB 74/50 (45) 100/5A, 1.5VA, cl. 1 In Stock check our stock at: www.lumel.com.pl
order code: LH000-0904-130-124

20 www.lumel.com.pl
BUSBAR SERIES - LCTB 86

LCTB 86/40 (45) LCTB 86/50 (45) LCTB 86/60 (45) INPUT:
Hole diameter Ø 36 mm Ø 46 mm Ø 51 mm

40 x 10 mm, 50 x 12 mm, 60 x 12 mm,


Busbar 2 x 40 x 15 mm 2 x 50 x 15 mm
2 x 30 x 15 mm
Depth 45 mm 45 mm 45 mm
Width 86 mm 86 mm 86 mm
OUTPUTS:
Primary current 50 A...1000 A 100 A...1250 A 100 A...1600 A
Secondary current 1 A, 5 A
5A
Accuracy class 0.2S; 0.2; 0.5S; 0.5; 1

DIMENSIONS

LCTB 86/40 (45) LCTB 86/50 (45) LCTB 86/60 (45)

Transformer
type LCTB 86/40 (45) LCTB 86/50 (45) LCTB 86/60 (45)

Accuracy class 0.2S 0.2 0.5S 0.5 1 0.2S 0.2 0.5S 0.5 1 0.2S 0.2 0.5S 0.5 1

Rated primary
class Transformer burden

50 A - - - - 1.5 VA - - - - - - - - - -
60 A - - - - 1.5 VA - - - - - - - - - -
75 A - - - - 2.5 VA - - - - - - - - - -
80 A - - - - 2.5 VA - - - - - - - - - -
100 A 1.5 VA 1.5 VA 1.5 VA 1.5 VA 3.75 VA - - - - 1.5 VA - - - - 1 VA
120 A 1.5 VA 1.5 VA 1.5 VA 2.5 VA 5 VA - - - 1.5 VA 2.5 VA - - - - 1.5 VA
125 A 1.5 VA 1.5 VA 1.5 VA 2.5 VA 5 VA - - - 1.5 VA 2.5 VA - - - - 2.5 VA
150 A 2.5 VA 2.5 VA 2.5 VA 3.75 VA 5 VA - - - 2.5 VA 5 VA - - - - 2.5 VA
200 A 2.5 VA 2.5 VA 2.5 VA 5 VA 7.5 VA - - - 5 VA 7.5 VA - - - 1.5 VA 3.75 VA
250 A 3.75 VA 3.75 VA 3.75 VA 7.5 VA 12.5 VA - - - 7.5 VA 10 VA - - - 2.5 VA 5 VA
300 A 5 VA 5 VA 5 VA 10 VA 15 VA 5 VA 1.5 VA 5 VA 7.5 VA 10 VA 1.5 VA 1.5 VA 1.5 VA 5 VA 7.5 VA
400 A 7.5 VA 7.5 VA 7.5 VA 15 VA 20 VA 7.5 VA 2.5VA 7.5 VA 15 VA 15 VA 2.5 VA 2.5 VA 2.5 VA 10 VA 1 2.5 VA
500 A 10 VA 10 VA 10 VA 20 VA 30 VA 7.5 VA 5 VA 7.5 VA 15 VA 20 VA 2.5 VA 3.75 VA 2.5 VA 10 VA 12.5 VA
600 A 15 VA 15 VA 15 VA 30 VA 30 VA 10 VA 7.5 VA 10 VA 15 VA 20 VA 5 VA 5 VA 5 VA 15 VA 15 VA
750 A 15 VA 15 VA 15 VA 30 VA 30 VA 7.5 VA 10 VA 7.5 VA 15 VA 20 VA 5 VA 10 VA 5 VA 15 VA 20 VA
800 A 15 VA 15 VA 15 VA 30 VA 30 VA 10 VA 12.5 VA 10 VA 20 VA 30 VA 7.5 VA 12.5 VA 7.5 VA 20 VA 20 VA
1000 A 15 VA 15 VA 15 VA 30 VA 30 VA 12.5 VA 20 VA 12.5 VA 30 VA 30 VA 10 VA 15 VA 10 VA 20 VA 20 VA
1200 A - - - - - 12.5 VA 20 VA 12.5 VA 30 VA 30 VA 10 VA 15 VA 10 VA 20 VA 20 VA
1250 A - - - - - 12.5 VA 20 VA 12.5 VA 30 VA 30 VA 10 VA 15 VA 10 VA 20 VA 20 VA
1500 A - - - - - - - - - - 10 VA 15 VA 10 VA 20 VA 20 VA
1600 A - - - - - - - - - - 10 VA 15 VA 10 VA 20 VA 20 VA
ORDER ACCESSORIES:
Required data: transformer type/ primary current/ secondary current/ power/ accuracy class DIN rail mounting base  DISPATCH WITHIN 48H:
Order example: LCTB 86/50 (45) 100/5A, 1.5VA, cl. 1 order code: LH000-0904-130-124 In Stock check our stock at: www.lumel.com.pl

LC T B S E R I E S 21
LCTB 100 - BUSBAR SERIES

INPUT:
LCTB 100/100V (45) LCTB 100/130V (45)
Busbar 41 x 103 mm 38 x 128 mm

Depth 45 mm 45 mm
Width 100 mm 100 mm
OUTPUTS: Primary current 400 A...2500 A 400 A...3000 A
Secondary current 1 A, 5 A
5A Accuracy class 0.2S; 0.2; 0.5S; 0.5; 1 0.2; 0.5; 1

DIMENSIONS

LCTB 100/100V (45) LCTB 100/130V (45)

Transformer type LCTB 100/100V (45) LCTB 100/130V (45)


Accuracy class 0.2S 0.2 0.5S 0.5 1 0.2 0.5 1
Rated primary current Transformer burden
400 A - - - 2.5 VA 5 VA - 2.5 VA 5 VA
500 A - - - 2.5 VA 5 VA - 2.5 VA 5 VA
600 A - - - 2.5 VA 5 VA - 2.5 VA 5 VA
750 A - - - 2.5 VA 5 VA - 2.5 VA 7.5 VA
800 A - - - 5 VA 10 VA - 5 VA 7.5 VA
1000 A - 5 VA - 10 VA 15 VA - 10 VA 10 VA
1200 A 5 VA 5 VA 5 VA 10 VA 15 VA - 10 VA 15 VA
1250 A 5 VA 5 VA 5 VA 10 VA 15 VA - 10 VA 15 VA
1500 A 5 VA 5 VA 5 VA 15 VA 30 VA 5 VA 15 VA 30 VA
1600 A 7.5 VA 10 VA 7.5 VA 15 VA 30 VA 5 VA 15 VA 30 VA
2000 A 7.5 VA 10 VA 7.5 VA 15 VA 30 VA 5 VA 15 VA 30 VA
2500 A 10 VA 10 VA 10 VA 15 VA 20 VA 5 VA 15 VA 30 VA
3000 A - - - - - 5 VA 10 VA 12.5 VA

ORDER ACCESSORIES:
Required data: transformer type/ primary current/ secondary current/ power/ accuracy class DIN rail mounting base
Order example: LCTB 100/130V (45) 400/5A, 2.5VA, cl. 1 order code: LH000-0904-130-124

22 www.lumel.com.pl
BUSBAR SERIES - LCTB 104

LCTB 104/60 (45) LCTB 104/80 (45)


INPUT:
Hole diameter Ø 54 mm Ø 65 mm

60 x 12 mm, 2 x 50 x 15mm, 80 x 12 mm, 2 x 60 x 15 mm,


Busbar
2 x 40 x 20 mm 2 x 50 x 25 mm
Depth 45 mm 45 mm
Width 104 mm 104 mm
OUTPUTS:
Primary current 100 A...1600 A 200 A...2000 A

Secondary current 1 A, 5 A 5A
Accuracy class 0.2S; 0.2; 0.5S; 0.5; 1

DIMENSIONS

LCTB 104/60 (45) LCTB 104/80 (45)

Transformer type LCTB 104/60 (45) LCTB 104/80 (45)


Accuracy class 0.2S 0.2 0.5S 0.5 1 0.2S 0.2 0.5S 0.5 1
Rated primary current Transformer burden
100 A - - - - 1.5 VA - - - - -
120 A - - - - 2.5 VA - - - - -
125 A - - - - 2.5 VA - - - - -
150 A - - - 2.5 VA 5 VA - - - - -
200 A - - - 5 VA 10 VA - - - - 1.5 VA
250 A - 1.5 VA - 7.5 VA 12.5 VA - - - 1.5 VA 2.5 VA
300 A 1.5 VA 2.5 VA 1.5 VA 10 VA 15 VA - - - 2.5 VA 7.5 VA
400 A 2.5 VA 3.75 VA 2.5 VA 5 VA 10 VA 15 VA - 1.5 VA - 5 VA 10 VA
500 A 3.75 VA 7.5 VA 3.75 VA 15 VA 20 VA - 1.5 VA - 5 VA 10 VA
600 A 5 VA 10 VA 5 VA 15 VA 30 VA - 2.5 VA - 7.5 VA 12.5 VA
750 A 5 VA 15 VA 5 VA 20 VA 30 VA 5 VA 5 VA 5 VA 10 VA 15 VA
800 A 7.5 VA 15 VA 7.5 VA 30 VA 30 VA 5 VA 7.5 VA 5 VA 10 VA 15 VA
1000 A 10 VA 20 VA 10 VA 30 VA 45 VA 7.5 VA 12.5VA 7.5 VA 20 VA 20 VA
1200 A 10 VA 30 VA 10 VA 30 VA 45 VA 10 VA 15 VA 10 VA 20 VA 30 VA
1250 A 10 VA 30 VA 10 VA 30 VA 45 VA 10 VA 15 VA 10 VA 20 VA 30 VA
1500 A 10 VA 30 VA 10 VA 30 VA 45 VA 10 VA 15 VA 10 VA 20 VA 30 VA
1600 A 10 VA 30 VA 10 VA 30 VA 45 VA 10 VA 15 VA 10 VA 20 VA 30 VA
2000 A - - - - - 10 VA 15 VA 10 VA 20 VA 30 VA

ORDER
Required data: transformer type/ primary current/ secondary current/ power/ accuracy class
ACCESSORIES:
DIN rail mounting base  DISPATCH WITHIN 48H:
Order example: LCTB 104/60 (45) 100/5A, 1.5VA, cl. 1 order code: LH000-0904-130-124 In Stock check our stock at: www.lumel.com.pl

LC T B S E R I E S 23
LCTB 140 - BUSBAR SERIES
LCTB 140/80 (45) LCTB 140/100H (45) LCTB 140/100V (45) LCTB 140/130V (45)
Hole diameter Ø 72 mm Ø 86 mm Ø86 mm -
INPUT: 100 x 30 mm, 100 x 30 mm,
Busbar 80 x 30 mm, 2 x 80 x 25 mm, 2 x 80 x 25 mm, 70 x 130 mm
2 x 60 x 25 mm 2 x 70 x 30 mm 2 x 70 x 30 mm
Depth 45 mm 45 mm 45 mm 45 mm
Width 140 mm 140 mm 140 mm 140 mm

Primary current 200 A...2000 A 200 A...4000 A 200 A...3000 A 400 A...5000 A
OUTPUTS:
Secondary 1 A, 5 A
current
5A
Accuracy class 0,2S; 0,2; 0.5S; 0,5; 1 0,2; 0,5; 1

DIMENSIONS

LCTB 140/80 (45) LCTB 140/100H (45)

Transformer type LCTB 140/80 (45) LCTB 140/100H (45)

Accuracy class 0.2S 0.2 0.5S 0.5 1 0.2S 0.2 0.5S 0.5 1

Rated primary current Transformer burden


200 A - - - 2.5 VA 5 VA - - - 1.5 VA 3.75 VA
250 A - - - 5 VA 10 VA - - - 2.5 VA 5 VA
300 A - 1.5 VA - 7.5 VA 15 VA - - - 3.75VA 7.5 VA
400 A - 2.5 VA - 10 VA 20 VA - 1.5 VA - 7.5 VA 10 VA
500 A 2.5 VA 5 VA 2.5 VA 15 VA 30 VA - 2.5 VA - 10 VA 12.5VA
600 A 3.75VA 7.5 VA 3.75 VA 15 VA 30 VA 2.5 VA 3.75 VA 2.5 VA 10 VA 15 VA
750 A 5 VA 10 VA 5 VA 15 VA 45 VA 5 VA 5 VA 5 VA 15 VA 20 VA
800 A 5 VA 10 VA 5 VA 15 VA 45 VA 5 VA 5 VA 5 VA 15 VA 20 VA
1000 A 10 VA 15 VA 10 VA 30 VA 60 VA 5 VA 10 VA 5 VA 15 VA 20 VA
1200 A 12.5 VA 15 VA 12.5 VA 30 VA 60 VA 10 VA 15 VA 10 VA 15 VA 30 VA
1250 A 12.5 VA 30 VA 12.5 VA 60 VA 60 VA 10 VA 15 VA 10 VA 15 VA 30 VA
1500 A 15 VA 30 VA 15 VA 60 VA 60 VA 15 VA 20VA 15 VA 20 VA 30 VA
1600 A 15 VA 30 VA 15 VA 60 VA 60 VA 15 VA 20 VA 15 VA 20 VA 45 VA
2000 A 15 VA 30 VA 15 VA 60 VA 60 VA 15 VA 30 VA 15 VA 45 VA 45 VA
2500 A - - - - - 15 VA 30 VA 15 VA 45 VA 45 VA
3000 A - - - - - 15 VA 30 VA 15 VA 60 VA 60 VA
4000 A - - - - - 15 VA 30 VA 15 VA 60 VA 60 VA

 DISPATCH WITHIN 48H:


In Stock check our stock at: www.lumel.com.pl

24 www.lumel.com.pl
BUSBAR SERIES - LCTB 140

DIMENSIONS
LCTB 140/100V (45) LCTB 140/130V (45)

Transformer type LCTB 140/100V (45) LCTB 140/130V (45)

Accuracy class 0.2S 0.2 0.5S 0.5 1 0.2 0.5 1

Rated primary current Transformer burden


200 A - - - 1.5 VA 3.75 VA - - -
250 A - - - 2.5 VA 5 VA - - -
300 A - - - 3.75 VA 7.5 VA - - -
400 A - 1.5 VA - 10 VA 10 VA - 3.75 VA 5 VA
500 A - 2.5 VA - 10 VA 12.5 VA - 3.75 VA 5VA
600 A 2.5VA 3.75 VA 2.5 VA 12.5 VA 15 VA - 3.75 VA 5 VA
750 A 5 VA 5 VA 5 VA 15 VA 20 VA - 5 VA 7.5 VA
800 A 5 VA 5 VA 5 VA 15 VA 20 VA - 5 VA 7.5 VA
1000 A 5 VA 10 VA 5 VA 15 VA 20 VA 5 VA 10 VA 10 VA
1200 A 10 VA 15 VA 10 VA 15 VA 30 VA 7.5 VA 10 VA 15 VA
1250 A 10 VA 15 VA 10 VA 15 VA 30 VA 7.5 VA 10 VA 15 VA
1500 A 15VA 20 VA 15 VA 30 VA 30 VA 10VA 15 VA 15 VA
1600 A 15VA 20 VA 15 VA 45 VA 45 VA 10 VA 15 VA 15 VA
2000 A 15VA 30 VA 15 VA 45 VA 45 VA 15 VA 20 VA 20 VA
2500 A 15VA 30 VA 15 VA 45 VA 45VA 15 VA 20 VA 20 VA
3000 A 15VA 30 VA 15 VA 60 VA 60 VA 15 VA 20 VA 20 VA
4000 A - - - - - 15 VA 20 VA 20 VA
5000 A - - - - - 15 VA 20 VA 20 VA

ORDER
Required data: transformer type/ primary current/ secondary current/ power/ accuracy class
Order example: LCTB 140/100H (45) 200/5A, 3.75VA, cl. 1

LC T B S E R I E S 25
LCTB 225 - BUSBAR SERIES
LCTB 225/125 (50) LCTB 225/167 (50)
INPUT:
Busbar 124 x 93 mm 166 x 65 mm

Depth 50 mm 50 mm

Width 225 mm 225 mm

OUTPUTS: Primary current 600 A...6000 A 1000 A...7500 A

Secondary current 1 A, 5 A
5A Accuracy class 0.2S; 0.2; 0.5S; 0.5; 1

DIMENSIONS

LCTB 225/125 (50) LCTB 225/167 (50)

Transformer type LCTB 225/125 (50) LCTB 225/167 (50)


Accuracy class 0.2S 0.2 0.5S 0.5 1 0.2S 0.2 0.5S 0.5 1
Rated primary current Transformer burden
600 A - 5 VA - 5 VA 10 VA - - - - -
750 A - 5 VA - 10 VA 10 VA - - - - -
800 A - 5 VA - 10 VA 10 VA - - - - -
1000 A 5 VA 10 VA 5 VA 10 VA 15 VA - 3.75 VA - 5 VA 10 VA
1200 A 5 VA 10 VA 5 VA 10 VA 15 VA - 5 VA - 10 VA 15 VA
1250 A 5 VA 10 VA 5 VA 10 VA 15 VA - 5 VA - 10 VA 15 VA
1500 A 7.5 VA 10 VA 7.5 VA 15 VA 30 VA 5 VA 10 VA 5 VA 15 VA 30 VA
1600 A 7.5 VA 10 VA 7.5 VA 15 VA 30 VA 5 VA 10 VA 5 VA 15 VA 30 VA
2000 A 10 VA 10 VA 10 VA 15 VA 30 VA 7.5 VA 10 VA 7.5 VA 30 VA 30 VA
2500 A 10 VA 15 VA 10 VA 30 VA 30 VA 10 VA 15 VA 10 VA 30 VA 45 VA
3000 A 10 VA 15 VA 10 VA 30 VA 60 VA 10 VA 15 VA 10 VA 30 VA 45 VA
4000 A 15 VA 30 VA 15 VA 45 VA 60 VA 10 VA 15 VA 10 VA 30 VA 45 VA
5000 A 15VA 30 VA 15 VA 100 VA 100 VA 15VA 20 VA 15 VA 30 VA 45 VA
6000 A 15 VA 60 VA 15 VA 100 VA 100 VA 15 VA 20 VA 15 VA 30 VA 45 VA
7500 A - - - - - 15 VA 20 VA 15 VA 30 VA 45 VA

ORDER
Required data: transformer type/ primary current/ secondary current/ power/ accuracy class
Order example: LCTB 225/125 (50) 600/5A, 10VA, cl. 1

26 www.lumel.com.pl
SPLIT CORE SERIES - LCTS

LCTS 93/30SC (40) LCTS 125/50SC (40) LCTS 155/80SC (40) LCTS 195/80SC (64)
Window INPUT:
23 x 33 mm 85 x 54 mm 85 x 125 mm 82 x 162 mm
dimensions
Depth 40 mm 40 mm 40 mm 64 mm
Width 93 mm 125 mm 155 mm 195 mm
Primary 100 A...400 A 250 A...1000 A 250 A...3000 A 500 A...5000 A
current
OUTPUTS:
Secondary 1 A, 5 A
current
Accuracy
5A
0,5; 1
class

DIMENSIONS

LCTS 93/30SC (40) LCTS 125/50SC, 155/80SC, 195/80SC


Side view (dimensions in mm)
Type a’ b’ c’ d’ e’
side view

125/50SC (40) 60 50 40 65 80
155/80SC (40) 60 50 40 65 80
195/80SC (64) 84 74 64 80 100

Front view (dimensions in mm)


front view

Type a b c d e
125/50SC (40) 54 158 85 106 125
155/80SC (40) 85 198 125 136 155
195/80SC (64) 80 245 160 179 195

Transformer type LCTS 93/30SC (40) LCTS 125/50SC (40) LCTS 155/80SC (40) LCTS 195/80SC (64)
Accuracy class 0.5 1 0.5 1 0.5 1 0.5 1

Rated primary current Transformer burden


100 A - 1.5 VA - - - - - -
150 A - 1.75 VA - - - - - -
200 A - 2.5 VA - - - - - -
250 A - 3.75 VA 1 VA 2.5 VA 1 VA 2.5 VA - -
300 A 2.5 VA 5 VA 2.5 VA 3.75 VA 1.5 VA 3.75 VA - -
400 A 3.75 VA 6.25 VA 2.5 VA 3.75 VA 2.5 VA 3.75 VA - -
500 A - - 3.75 VA 5 VA 3.75 VA 5 VA 1.25 VA 5 VA
600 A - - 5 VA 7.5 VA 5 VA 7.5 VA 1.25 VA 5 VA
750 A - - 7.5 VA 10 VA 7.5 VA 10 VA 5 VA 10 VA
800 A - - 7.5 VA 10 VA 7.5 VA 10 VA 7.5 VA 10 VA
1000 A - - 10 VA 15 VA 10 VA 15 VA 10 VA 20 VA
1200 A - - - - 15 VA 30 VA 15 VA 20 VA
1250 A - - - - 15 VA 30 VA 15 VA 20 VA
1500 A - - - - 20 VA 45 VA 20 VA 30 VA
1600 A - - - - 20 VA 45 VA 20 VA 30 VA
2000 A - - - - 20 VA 45 VA 25 VA 30 VA
2500 A - - - - 25 VA 45 VA 25 VA 30 VA
3000 A - - - - 30 VA 45 VA 30 VA 45 VA
4000 A - - - - - - 30 VA 45 VA
5000 A - - - - - - 30 VA 45 VA

ORDER
Required data: transformer type/ primary current/ secondary current/ power/ accuracy class  DISPATCH WITHIN 48H:
Order example: LCTS 93/30SC (40) 100/5A, 1.5VA, cl. 1 In Stock check our stock at: www.lumel.com.pl

LC T S S E R I E S 27
LCTP - 3-PHASE BUSBAR SERIES

NEW INPUT:
LCTP 75/15 (60) LCTP 105/21 (40) LCTP 140/31 (40)
Busbar 14 x 24 mm 20 x 24 mm 31 x 36 mm
150 A
Depth 60 mm 40 mm 40 mm
630 A Width 76.5 mm 105 mm 140 mm
Primary current 100…160 A 100…250 A 250…630 A

OUTPUT: Secondary current 5A

Accuracy class 0.5; 1


5A

DIMENSIONS

LCTP 75/15 (60) LCTP 105/21 (40) LCTP 140/31 (40)

Transformer type LCTP 75/15 (60) LCTP 105/21 (40) LCTP 140/31 (40)
Accuracy class 05 1 0.5 1 0.5 1

Rated primary current Transformer burden


100 A - 1.5 VA - 1.5 VA - -
125 A - 1.5 VA - 1.5 VA - -
150 A 1.5 VA 1.5 VA - 1.5 VA - -
160 A 1.5 VA 1.5 VA 1.5 VA 1.5 VA - -
200 A - - 1.5 VA 1.5 VA - -
250 A - - 1.5 VA 1.5 VA 1.5 VA 1.5 VA
300 A - - - - 2.5 VA 2.5 VA
400 A - - - - 2.5 VA 2.5 VA
500 A - - - - 2.5 VA 2.5 VA
600 A - - - - 2.5 VA 2.5 VA
630 A - - - - 2.5 VA 2.5 VA

ORDER
Required data: transformer type/ primary current/ secondary current/ power/ accuracy class
Order example: LCTP140/31 (40) 600/5A; 2.5 VA; cl. 1

28 www.lumel.com.pl
3-PHASE ROUND CONDUCTOR SERIES- LCTP

LCTP 185/27 (45) LCTP 185/37 (45) INPUT: NEW


Hole diameter Ø 27 mm Ø 37 mm 100 A
Depth 45 mm 45 mm
800 A
Width 185 mm 185 mm

Primary current 100…500 A 300…800 A


OUTPUT:
Secondary current 5A
Accuracy class 1 5A

DIMENSIONS
LCTP 185/27 (45) LCTP 185/37 (45)

Transformer type LCTP 185/27 (45) LCTP 185/37 (45)


Accuracy class 1 1
Rated primary current Transformer burden
100 A 1.5 VA -
150 A 1.5 VA -
200 A 2.5 VA -
250 A 2.5 VA -
300 A 5 VA 2.5 VA
400 A 5 VA 5 VA
500 A 5 VA 5 VA
600 A - 5 VA ORDER
800 A - 5 VA Required data: transformer type/ primary current/ secondary current/ power/ accuracy class
Order example: LCTP 185/27 (45) 100/5 A, 1.5 VA, cl. 1

LC T P S E R I E S 29
ACCESSORIES

Terminal
Terminal Cap

Thread Cutting
Screw

Core Swivel

Shoe for Self


Tapping Screw
DIN Rail Plate

Case
Wall Mounting Clamp

DIN Rail Mounting Base: Accessories


(additional accessories - have to be order separatly)
Description View
Order code Transformer type View Thread cutting screw
4 x 35mm
LCTR 50 (30), Thread cutting screw
LH000-0904-130-123 4 x 45mm
LCTB 50 (30)
Thread cutting screw
4 x 75mm
LH000-0904-130-002 LCTR 45, LCTB 45
Wall mounting clamp
LCTM 62W, LCTM 74W
LCTR 62,
LCTB 62 (40),
LH000-0904-130-124
LCTB 74, LCTB 86, Swivel
LCTB 100,
LCTB 104
Shoe for self tapping
M4 screw

Nut of M4 screw
(only for transformers
of LCTS type)

Locking pin

Thread cutting screw


M4 x 45 mm

30 www.lumel.com.pl
ACCESSORIES
Busbar mounting kit:
(delivered with each current transformer)

Kit order code Description No of pcs. Transformer type


LH000-0904-130-140 Wall mounting clamp 2 LCTR 45, LCTB 45, LCTM 62W, LCTM 74W
Thread cutting screw 4 x 35mm 2
Wall mounting clamp 2
LH000-0904-130-141 LCTR 50, LCTB 50
Swivel 2
Shoe for self tapping M4 screw 2
Thread cutting screw 4 x 45mm 2
Wall mounting clamp 2 LCTR 62, LCTB 62,
LH000-0904-130-142
Swivel 2 LCTB 74, LCTB 86

Shoe for self tapping M4 screw 2


Thread cutting screw 4 x 35mm 6
LCTB 100/100 V,
LH000-0904-130-147 Wall mounting clamp 2
LCTB 100/130 V
Shoe for self tapping M4 screw 6
Thread cutting screw 4 x 45mm 4
Wall mounting clamp 2
LH000-0904-130-143 LCTB 104
Swivel 4
Shoe for self tapping M4 screw 4
Thread cutting screw 4 x 75mm 4
Wall mounting clamp 2 LCTB 140/80,
LH000-0904-130-144 LCTB 140/100H,
Swivel 4 LCTB 140/100V
Shoe for self tapping M4 screw 4
Thread cutting screw 4 x 75mm 1
Thread cutting screw 4 x 45mm 5
LH000-0904-130-145 LCTB 140/130 V
Wall mounting clamp 2
Shoe for self tapping M4 screw 6
Thread cutting screw 4 x 75mm 6
LH000-0904-130-146 Wall mounting clamp 2 LCTB 225
Shoe for self tapping M4 screw 6
Thread cutting screw M4 x 45mm 4
Wall mounting clamp 2
LH000-0904-130-623 Shoe for self tapping M4 screw 4 LCTS 93/30SC
Locking pin 1
Nut of M4 screw 4
Thread cutting screw M4 x 45 mm 6
Wall mounting clamp 2
LH000-0904-130-624 Shoe for self tapping M4 screw 6 LCTS 125/50SC
Locking pin 1
Nut of M4 screw 6
Thread cutting screw M4 x 45 mm 8
Wall mounting clamp 2
LH000-0904-130-625 Shoe for self tapping M4 screw 8 LCTS 155/80SC
Locking pin 1
Nut of M4 screw 8
Thread cutting screw M4 x 45 mm 6
Wall mounting clamp 2
LH000-0904-130-656 LCTP
Shoe for self tapping M4 screw 6
Nut of M4 screw 6

ACC E S S O R I E S 31
We are one of leading European manufacturers
of electrical devices for automation and high pressure
aluminium castings. We have been on the market since 1953.
We have achieved our high position on the market due
to continuous development policy, competence of our employees
and modern equipment for research, design and production.

LUMEL S.A. is focused on 4 main activity fields:

• production of automatic devices for measurement, conversion,


control and recording, transmission and visualization
of various industrial processes;
• production and machining of high pressure castings
and manufacturing of moulds and tools;
• design and manufacturing of control and measuring systems,
• SMT assembly, precision engineering and production
of plastics parts.

We provide comprehensive solutions for various branches


of industry: power industry, chemical industry, metallurgy,
food industry,light industry, automotive industry,
white industry and mining.
We have been working according to: ISO 9001:2008,
ISO 14001:2004 and ISO/TS 16949.
7
201
uary
febr

LUMEL S.A. Please contact our distributor:


ul. Sulechowska 1, 65-022 Zielona Góra, POLAND
tel.: +48 68 45 75 100, fax +48 68 45 75 508
www.lumel.com.pl

Export department:
tel.: (+48 68) 45 75 139, 45 75 233, 45 75 321, 45 75 386
fax.: (+48 68) 32 54 091
e-mail: [email protected]

32 www.lumel.com.pl

You might also like