CONTENTS
Accessories...........................................................................................................30
3
CURRENT TRANSFORMERS SUMMARY
Range of primary currents
Class 0.2S Class 0.2 Class 0.5S Class 0.5 Class 1
Page no.
Busbar Transformer
dimensions type min max min max min max min max min max
4 www.lumel.com.pl
GENERAL OVERVIEW OF CURRENT TRANSFORMERS
N2
I1 = I2 .
N1
where: I1 - primary current, I2 - secondary current, N1 - number of turns of primary winding, N2 - number of turns of secondary winding, N2/N1 - rated transformation ratio
Current transformers are used mainly in such a way that the cable from the measured shock or bus current passes through the main hole transformer,
which is equivalent to one coil primary winding. In this case, the above equation simplifies to:
I1 = I2 . N2
The task is to reduce the transformer output current for currents of over 120% of measurement range, to protect against destruction of measuring devices connected
to the transformer in case of surges or failures in the primary circuit.
FEATURES:
• Wide range of accuracy classes: 0.2S, 0.2, 0.5S, 0.5, 1
• Wide range of supported primary currents, the dimensions of rails, the length of casing and hole diameters.
• Multiple mounting methods, including wall mounting, DIN rail 35mm, the conductor, a current bar.
• Shields designed to seal connections.
GENERAL SPECIFICATION
Applicable standard: IEC 61869-1/2
Case: 10% glass filled polycarbonate, flame retardant grades classified UL 94V-0
Connection: Two connection on each side. M4 screws with self lifting clamp strap.
Insulation class E (120°C max)
Maximum system voltage: 0.72 kV
Operating frequency: 50/60 Hz
Rated primary rating: 1 A…7500 A
Rated secondary output: 5 A or 1 A (for LCTP 3-phase current transformers only 5 A)
Rated burden: 1, 1.25, 1.5, 2.5, 3.75, 5, 7.5, 10, 12.5, 15, 20, 30, 45, 60, 100 VA
Accuracy class: 0.2, 0.2S, 0.5S – for laboratory and power measurement
0.5 – for accurate measuring
1 – for general measurement, for analog meters
Ambient temperature: -20°C …+45°C
Storage temperature: -50°C…+80°C
Thermal short circuit current (Ith): 40 x In for wound type
60 x In for bus bar type
Dynamic short circuit current (Idyn): 2.5xIth
Instrument security factor (FS): 2.5, 5, 10
In order to fulfill these stipulations it is necessary for the power of a current transformer offered to fully achieve the actual power requirements of the measurement setup.
In ascertaining the actual power requirements, consideration is to be made not only of the loss of power of the appliances to be connected up, but also the losses incurred
by the instrument leads.
FEATURES: OUTPUTS:
Class
5A
GENERAL OVERVIEW 5
GENERAL OVERVIEW OF CURRENT TRANSFORMERS
Power requirements for measuring apparatur and relays:
• Analog moving-iron meters 0.7 – 1.5VA
• Rectifier current meters 0.001 – 0.250 VA CONNECTION DIAGRAMM
• Multi-range current meters 0.005 – 5.000 VA OF CURRENT TRANSFORMERS
• Current recorders 0.300-9.000 VA
• Bimmetalic ammeters 2.5 – 3.0 VA
• Power meter 0.2 – 5.0 VA
• Power factor meter 2.0 – 6.0 VA IP
• Meters 0.4 – 1.0 VA
IS
• Relays 0.2 – 6.0 VA P1
• Power transducers 0.5 VA A
• Energy meters 2.5 VA
6 www.lumel.com.pl
LCTM - wound primary series LCTR -round conductor series LCTB - busbar series
Transformer type
LCTR 62/R (40)
Range
[A] Instrument security factor (FS)
1 15 10 5 15 10 5
2.5 15 10 5 15 10 5
5 15 10 5 15 10 5
7.5 15 10 5 15 10 5
10 15 10 5 15 10 5
15 15 10 5 15 10 5
20 15 10 5 15 10 5
25 15 10 5 15 10 5
30 15 10 5 15 10 5 5 5
40 15 10 5 5 5 5 5
50 15 10 5 5 5 5 5 5 5 5 10 5 5 5 5
60 15 10 5 5 5 5 5 5 5 5 10 5 5 5 5
75 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5
80 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5
100 5 5 5 5 5 5 10 5 5 5 5 5 5 5 5 5 5 5 5 5 10 5 5 5 5 10 5 5 5 5 5 15 5 5 5
120 5 5 5 5 5 5 10 5 5 5 5 5 5 5 5 5 5 5 5 5 10 5 5 5 5 10 5 5 5 5 5 15 5 5 5
7
INSTRUMENT SECURITY FACTOR
8
LCTB - busbar series
Transformer type
LCTB 74/20 (45)
LCTB 74/30 (45)
LCTB 74/40 (45)
LCTB 74/50 (45)
LCTB 86/40 (45)
LCTB 86/50 (45)
LCTB 86/60 (45)
Class 0.2S 0.2 0.5S 0.5 1 0.2S 0.2 0.5S 0.5 1 0.2S 0.2 0.5S 0.5 1 0.2S 0.2 0.5S 0.5 1 0.2S 0.2 0.5S 0.5 1 0.2S 0.2 0.5S 0.5 1 0.2S 0.2 0.5S 0.5 1
Range
[A] Instrument security factor (FS)
30 10 10
40 10 10 5
50 10 10 5 5
60 5 5 5 5
75 15 5 10 5 5 5
80 15 5 10 5 5 5
100 5 15 5 10 5 5 15 5 10 5 10 5 5 5 10 5 10 5 5 5
120 5 15 5 10 5 5 15 5 10 5 10 5 5 5 10 5 10 5 10 5 5
125 5 15 5 10 5 5 15 5 10 5 10 5 5 5 10 5 10 5 10 5 5
INSTRUMENT SECURITY FACTOR
150 5 15 5 10 5 5 15 5 5 5 5 5 5 5 10 5 10 5 5 5 5
200 5 10 5 5 5 5 15 5 5 5 5 10 5 5 5 5 5 5 10 5 10 5 5 5 5 5
250 5 10 5 5 5 5 10 5 5 5 5 10 5 5 5 5 10 5 5 5 5 10 5 5 5 5 5 5 5
www.lumel.com.pl
300 5 10 5 5 5 5 10 5 5 5 5 5 5 5 5 5 10 5 5 5 5 10 5 5 5 5 10 5 5 5 5 10 5 5 5
400 5 10 5 5 5 10 10 10 5 5 5 5 5 5 5 5 5 5 5 5 15 10 15 5 5 5 10 5 5 5 5 10 5 5 5
500 10 10 10 5 5 5 5 5 5 5 5 5 5 5 5 15 5 15 5 5 5 10 5 5 5 5 10 5 5 5
600 10 10 10 5 5 10 5 10 5 5 5 5 5 5 5 10 5 10 5 5 5 10 5 5 5 10 10 10 5 5
750 10 10 10 5 5 10 5 10 5 5 5 5 5 5 5 10 5 10 5 5 10 10 10 5 5 10 5 10 5 5
800 10 10 10 5 5 5 5 5 5 5 5 5 5 5 5 10 5 10 5 5 10 5 10 5 5 10 5 10 5 5
1000 5 5 5 5 5 5 5 5 5 5 10 5 10 5 5 5 5 5 5 5 10 5 10 5 5
1200 5 5 5 5 5 10 5 10 5 5
1250 5 5 5 5 5 10 5 10 5 5
1500 5 5 5 5 5
1600 5 5 5 5 5
LCTB - busbar series
Transformer type
LCTB104/60 (45)
LCTB 104/80 (45)
LCTB 140/80 (45)
9
INSTRUMENT SECURITY FACTOR
W
NE
LCTP -
10
LCTB - busbar series LCTS - split core series LCTP- busbar series round conduc-
tor series
Transformer type
LCTP 75/15 (60)
LCTP 105/21 (40)
LCTP 140/31 (40)
LCTP 185/27 (45)
LCTP 185/37 (45)
750 10 10 10 10 10 10 10 30 30
800 10 10 10 10 10 10 10 30 30 5
1000 10 10 10 10 10 10 10 10 10 10 10 10 30 30
www.lumel.com.pl
1200 10 10 10 10 10 10 10 10 10 10 10 10 30 30
1250 10 10 10 10 10 10 10 10 10 10 10 10 30 30
1500 10 10 10 10 5 10 10 10 10 5 10 10 10 10 30 30
1600 10 10 10 10 5 10 10 10 10 5 10 10 10 10 30 30
2000 10 10 10 10 5 10 10 10 10 5 10 10 10 10 30 30
2500 10 10 10 10 5 10 10 10 10 5 10 10 30 30
3000 10 10 10 10 5 10 10 10 10 5 10 10 30 30
3200 10 10 10 10 5
4000 10 10 10 10 5 15 10 15 10 10 30 30
5000 15 15 15 5 5 15 10 15 10 10 30 30
6000 15 15 15 5 5 15 10 15 10 10
7500 15 15 15 10 10
WOUND PRIMARY SERIES - LCTM
Width 62 mm 74 mm
DIMENSIONS
LC T M S E R I E S 11
LCTR - ROUND CONDUCTOR SERIES
LCTR 45/14 (40) LCTR 50/14 (30) LCTR 50/14 (50) LCTR 62/R (40)
INPUT: Hole
diameter Ø 14 mm Ø 14 mm Ø 14 mm Ø 22 mm
Depth 40 mm 31 mm 51 mm 40 mm
Width 45 mm 50 mm 50 mm 62 mm
5A Accuracy
class 0.5; 1 0.2; 0.5S; 0.5; 1
DIMENSIONS
12 www.lumel.com.pl
ROUND CONDUCTOR SERIES - LCTR
DIMENSIONS
ORDER
Required data: transformer type/ primary current/ secondary current/ power/ accuracy class
ACCESSORIES:
DIN rail mounting base DISPATCH WITHIN 48H:
Order example: LCTR 50/14 (50) 100/5A, 5VA, cl. 1 - for details see page 25 In Stock check our stock at: www.lumel.com.pl
LC T R S E R I E S 13
LCTB 45 - BUSBAR SERIES
INPUT:
Busbar 20 x 10 mm
Depth 40 mm
Width 45 mm
DIMENSIONS
14 www.lumel.com.pl
BUSBAR SERIES - LCTB 50
LCTB 50/21 (30) LCTB 50/30 (30) LCTB 50/21 (50) LCTB 50/30 (50)
Hole
diameter Ø 21 mm Ø 26 mm Ø 21 mm Ø26 mm INPUT:
Busbar 20 x 10 mm 30 x 10 mm 20 x 10 mm 30 x 10 mm
Depth 31 mm 31 mm 51 mm 51 mm
Width 50 mm 50 mm 50 mm 50 mm
Primary
OUTPUTS:
current 40 A...400 A 75 A...600 A 50 A...400 A 50 A... 600 A
Secondary
current 1 A, 5 A 5A
Accuracy 0.5; 1
class
DIMENSIONS
LC T B S E R I E S 15
LCTB 50 - BUSBAR SERIES
DIMENSIONS
ORDER
Required data: transformer type/ primary current/ secondary current/ power/ accuracy class
ACCESSORIES:
DIN rail mounting base
DISPATCH WITHIN 48H:
Order example: LCTB 50/21 (50) 100/5A, 5VA, cl. 1 - for details see page 25 In Stock check our stock at: www.lumel.com.pl
16 www.lumel.com.pl
BUSBAR SERIES - LCTB 62
LCTB 62/20 (40) LCTB 62/30 (40) LCTB 62/30 (50) LCTB 62/40 (40)
Hole - Ø 30 mm Ø 28 mm Ø 31 mm
diameter INPUT:
30x10 mm, 40x10 mm,
Busbar 20x12 mm 30x10 mm
2x25 x10 mm 2 x 30 x 10 mm
Depth 40 mm 40 mm 50 mm 40 mm
Width 62 mm 62 mm 62 mm 62 mm
Secondary
current 1 A, 5 A 5A
Accuracy 0.2S; 0.2; 0.5S; 0.5; 1
class
DIMENSIONS
750 A - - - - - 10 VA 10 VA 10 VA 15 VA 15 VA
800 A - - - - - 10 VA 10 VA 10 VA 15 VA 15 VA
LC T B S E R I E S 17
LCTB 62 - BUSBAR SERIES
DIMENSIONS
Accuracy class 0.2S 0.2 0.5S 0.5 1 0.2S 0.2 0.5S 0.5 1
Rated primary current Transformer burden
40 A - - - - 1 VA - - - - -
50 A - - - - 2.5 VA - - - - -
60 A - - - - 2.5 VA - - - - -
75 A - - - 2.5 VA 2.5 VA - - - - -
80 A - - - 2.5 VA 3.75 VA - - - - -
100 A 1.25 VA 1.25 VA 1.25 VA 5 VA 5 VA - - - - 1 VA
120 A 1.25 VA 1.25 VA 1.25 VA 5 VA 5 VA - - - - 1.5 VA
125 A 1.25 VA 1.25 VA 1.25 VA 5 VA 5 VA - - - - 1.5 VA
150 A 2 VA 2 VA 2 VA 5 VA 7.5 VA - - - 2.5 VA
200 A 5 VA 3.75 VA 5 VA 10 VA 15 VA 1 VA 1 VA 1 VA 1.5 VA 3.75 VA
250 A 5 VA 5 VA 5 VA 15 VA 15 VA 1.5 VA 1.5 VA 1.5 VA 2.5 VA 5 VA
300 A 5 VA 5 VA 5 VA 15 VA 15 VA 1.5 VA 1.5 VA 1.5 VA 5 VA 5 VA
400 A 10 VA 6.25VA 10 VA 15 VA 30 VA 2.5 VA 2.5 VA 2.5 VA 5 VA 5 VA
500 A 5 VA 7.5 VA 5 VA 15 VA 30 VA 3.75 VA 5 VA 3.75 VA 5 VA 5 VA 7.5 VA
600 A 6.25 VA 10 VA 6.25 VA 20 VA 30 VA 5 VA 7.5 VA 5 VA 7.5 VA 10 VA
750 A 6.25 VA 10 VA 6.25 VA 20 VA 30 VA 5 VA 10 VA 5 VA 10 VA 10 VA
800 A 6.25 VA 10 VA 6.25 VA 20 VA 30 VA 5 VA 10 VA 5 VA 10 VA 10 VA
ORDER
Required data: transformer type/ primary current/ secondary current/ power/ accuracy class
ACCESSORIES:
DIN rail mounting base
DISPATCH WITHIN 48H:
Order example: LCTB 62/40 (40) 100/5A, 1VA, cl. 1 - for details see page 25 In Stock check our stock at: www.lumel.com.pl
18 www.lumel.com.pl
BUSBAR SERIES - LCTB 74
LCTB 74/20 (45) LCTB 74/30 (45) LCTB 74/40 (45) LCTB 74/50 (45)
Hole Ø 20 mm Ø26 mm Ø35 mm Ø 41 mm INPUT:
diameter
30x15 mm, 40x12 mm, 50x12 mm,
Busbar 20x10 mm
2x20x10 mm 2x30 x15 mm 2 x40x10 mm
Depth 45 mm 45 mm 45 mm 45 mm
Width 74 mm 74 mm 74 mm 74 mm
OUTPUTS:
Prąd 30 A...400 A 30 A...800 A 40 A...1000 A 100 A...1000 A
pierwotny
Secondary
5A
current 1 A, 5 A
DIMENSIONS
LC T B S E R I E S 19
LCTB 74 - BUSBAR SERIES
DIMENSIONS
ORDER
Required data: transformer type/ primary current/ secondary current/ power/ accuracy class
ACCESSORIES:
DIN rail mounting base
DISPATCH WITHIN 48H:
Order example: LCTB 74/50 (45) 100/5A, 1.5VA, cl. 1 In Stock check our stock at: www.lumel.com.pl
order code: LH000-0904-130-124
20 www.lumel.com.pl
BUSBAR SERIES - LCTB 86
LCTB 86/40 (45) LCTB 86/50 (45) LCTB 86/60 (45) INPUT:
Hole diameter Ø 36 mm Ø 46 mm Ø 51 mm
DIMENSIONS
Transformer
type LCTB 86/40 (45) LCTB 86/50 (45) LCTB 86/60 (45)
Accuracy class 0.2S 0.2 0.5S 0.5 1 0.2S 0.2 0.5S 0.5 1 0.2S 0.2 0.5S 0.5 1
Rated primary
class Transformer burden
50 A - - - - 1.5 VA - - - - - - - - - -
60 A - - - - 1.5 VA - - - - - - - - - -
75 A - - - - 2.5 VA - - - - - - - - - -
80 A - - - - 2.5 VA - - - - - - - - - -
100 A 1.5 VA 1.5 VA 1.5 VA 1.5 VA 3.75 VA - - - - 1.5 VA - - - - 1 VA
120 A 1.5 VA 1.5 VA 1.5 VA 2.5 VA 5 VA - - - 1.5 VA 2.5 VA - - - - 1.5 VA
125 A 1.5 VA 1.5 VA 1.5 VA 2.5 VA 5 VA - - - 1.5 VA 2.5 VA - - - - 2.5 VA
150 A 2.5 VA 2.5 VA 2.5 VA 3.75 VA 5 VA - - - 2.5 VA 5 VA - - - - 2.5 VA
200 A 2.5 VA 2.5 VA 2.5 VA 5 VA 7.5 VA - - - 5 VA 7.5 VA - - - 1.5 VA 3.75 VA
250 A 3.75 VA 3.75 VA 3.75 VA 7.5 VA 12.5 VA - - - 7.5 VA 10 VA - - - 2.5 VA 5 VA
300 A 5 VA 5 VA 5 VA 10 VA 15 VA 5 VA 1.5 VA 5 VA 7.5 VA 10 VA 1.5 VA 1.5 VA 1.5 VA 5 VA 7.5 VA
400 A 7.5 VA 7.5 VA 7.5 VA 15 VA 20 VA 7.5 VA 2.5VA 7.5 VA 15 VA 15 VA 2.5 VA 2.5 VA 2.5 VA 10 VA 1 2.5 VA
500 A 10 VA 10 VA 10 VA 20 VA 30 VA 7.5 VA 5 VA 7.5 VA 15 VA 20 VA 2.5 VA 3.75 VA 2.5 VA 10 VA 12.5 VA
600 A 15 VA 15 VA 15 VA 30 VA 30 VA 10 VA 7.5 VA 10 VA 15 VA 20 VA 5 VA 5 VA 5 VA 15 VA 15 VA
750 A 15 VA 15 VA 15 VA 30 VA 30 VA 7.5 VA 10 VA 7.5 VA 15 VA 20 VA 5 VA 10 VA 5 VA 15 VA 20 VA
800 A 15 VA 15 VA 15 VA 30 VA 30 VA 10 VA 12.5 VA 10 VA 20 VA 30 VA 7.5 VA 12.5 VA 7.5 VA 20 VA 20 VA
1000 A 15 VA 15 VA 15 VA 30 VA 30 VA 12.5 VA 20 VA 12.5 VA 30 VA 30 VA 10 VA 15 VA 10 VA 20 VA 20 VA
1200 A - - - - - 12.5 VA 20 VA 12.5 VA 30 VA 30 VA 10 VA 15 VA 10 VA 20 VA 20 VA
1250 A - - - - - 12.5 VA 20 VA 12.5 VA 30 VA 30 VA 10 VA 15 VA 10 VA 20 VA 20 VA
1500 A - - - - - - - - - - 10 VA 15 VA 10 VA 20 VA 20 VA
1600 A - - - - - - - - - - 10 VA 15 VA 10 VA 20 VA 20 VA
ORDER ACCESSORIES:
Required data: transformer type/ primary current/ secondary current/ power/ accuracy class DIN rail mounting base DISPATCH WITHIN 48H:
Order example: LCTB 86/50 (45) 100/5A, 1.5VA, cl. 1 order code: LH000-0904-130-124 In Stock check our stock at: www.lumel.com.pl
LC T B S E R I E S 21
LCTB 100 - BUSBAR SERIES
INPUT:
LCTB 100/100V (45) LCTB 100/130V (45)
Busbar 41 x 103 mm 38 x 128 mm
Depth 45 mm 45 mm
Width 100 mm 100 mm
OUTPUTS: Primary current 400 A...2500 A 400 A...3000 A
Secondary current 1 A, 5 A
5A Accuracy class 0.2S; 0.2; 0.5S; 0.5; 1 0.2; 0.5; 1
DIMENSIONS
ORDER ACCESSORIES:
Required data: transformer type/ primary current/ secondary current/ power/ accuracy class DIN rail mounting base
Order example: LCTB 100/130V (45) 400/5A, 2.5VA, cl. 1 order code: LH000-0904-130-124
22 www.lumel.com.pl
BUSBAR SERIES - LCTB 104
Secondary current 1 A, 5 A 5A
Accuracy class 0.2S; 0.2; 0.5S; 0.5; 1
DIMENSIONS
ORDER
Required data: transformer type/ primary current/ secondary current/ power/ accuracy class
ACCESSORIES:
DIN rail mounting base DISPATCH WITHIN 48H:
Order example: LCTB 104/60 (45) 100/5A, 1.5VA, cl. 1 order code: LH000-0904-130-124 In Stock check our stock at: www.lumel.com.pl
LC T B S E R I E S 23
LCTB 140 - BUSBAR SERIES
LCTB 140/80 (45) LCTB 140/100H (45) LCTB 140/100V (45) LCTB 140/130V (45)
Hole diameter Ø 72 mm Ø 86 mm Ø86 mm -
INPUT: 100 x 30 mm, 100 x 30 mm,
Busbar 80 x 30 mm, 2 x 80 x 25 mm, 2 x 80 x 25 mm, 70 x 130 mm
2 x 60 x 25 mm 2 x 70 x 30 mm 2 x 70 x 30 mm
Depth 45 mm 45 mm 45 mm 45 mm
Width 140 mm 140 mm 140 mm 140 mm
Primary current 200 A...2000 A 200 A...4000 A 200 A...3000 A 400 A...5000 A
OUTPUTS:
Secondary 1 A, 5 A
current
5A
Accuracy class 0,2S; 0,2; 0.5S; 0,5; 1 0,2; 0,5; 1
DIMENSIONS
Accuracy class 0.2S 0.2 0.5S 0.5 1 0.2S 0.2 0.5S 0.5 1
24 www.lumel.com.pl
BUSBAR SERIES - LCTB 140
DIMENSIONS
LCTB 140/100V (45) LCTB 140/130V (45)
ORDER
Required data: transformer type/ primary current/ secondary current/ power/ accuracy class
Order example: LCTB 140/100H (45) 200/5A, 3.75VA, cl. 1
LC T B S E R I E S 25
LCTB 225 - BUSBAR SERIES
LCTB 225/125 (50) LCTB 225/167 (50)
INPUT:
Busbar 124 x 93 mm 166 x 65 mm
Depth 50 mm 50 mm
Secondary current 1 A, 5 A
5A Accuracy class 0.2S; 0.2; 0.5S; 0.5; 1
DIMENSIONS
ORDER
Required data: transformer type/ primary current/ secondary current/ power/ accuracy class
Order example: LCTB 225/125 (50) 600/5A, 10VA, cl. 1
26 www.lumel.com.pl
SPLIT CORE SERIES - LCTS
LCTS 93/30SC (40) LCTS 125/50SC (40) LCTS 155/80SC (40) LCTS 195/80SC (64)
Window INPUT:
23 x 33 mm 85 x 54 mm 85 x 125 mm 82 x 162 mm
dimensions
Depth 40 mm 40 mm 40 mm 64 mm
Width 93 mm 125 mm 155 mm 195 mm
Primary 100 A...400 A 250 A...1000 A 250 A...3000 A 500 A...5000 A
current
OUTPUTS:
Secondary 1 A, 5 A
current
Accuracy
5A
0,5; 1
class
DIMENSIONS
125/50SC (40) 60 50 40 65 80
155/80SC (40) 60 50 40 65 80
195/80SC (64) 84 74 64 80 100
Type a b c d e
125/50SC (40) 54 158 85 106 125
155/80SC (40) 85 198 125 136 155
195/80SC (64) 80 245 160 179 195
Transformer type LCTS 93/30SC (40) LCTS 125/50SC (40) LCTS 155/80SC (40) LCTS 195/80SC (64)
Accuracy class 0.5 1 0.5 1 0.5 1 0.5 1
ORDER
Required data: transformer type/ primary current/ secondary current/ power/ accuracy class DISPATCH WITHIN 48H:
Order example: LCTS 93/30SC (40) 100/5A, 1.5VA, cl. 1 In Stock check our stock at: www.lumel.com.pl
LC T S S E R I E S 27
LCTP - 3-PHASE BUSBAR SERIES
NEW INPUT:
LCTP 75/15 (60) LCTP 105/21 (40) LCTP 140/31 (40)
Busbar 14 x 24 mm 20 x 24 mm 31 x 36 mm
150 A
Depth 60 mm 40 mm 40 mm
630 A Width 76.5 mm 105 mm 140 mm
Primary current 100…160 A 100…250 A 250…630 A
DIMENSIONS
Transformer type LCTP 75/15 (60) LCTP 105/21 (40) LCTP 140/31 (40)
Accuracy class 05 1 0.5 1 0.5 1
ORDER
Required data: transformer type/ primary current/ secondary current/ power/ accuracy class
Order example: LCTP140/31 (40) 600/5A; 2.5 VA; cl. 1
28 www.lumel.com.pl
3-PHASE ROUND CONDUCTOR SERIES- LCTP
DIMENSIONS
LCTP 185/27 (45) LCTP 185/37 (45)
LC T P S E R I E S 29
ACCESSORIES
Terminal
Terminal Cap
Thread Cutting
Screw
Core Swivel
Case
Wall Mounting Clamp
Nut of M4 screw
(only for transformers
of LCTS type)
Locking pin
30 www.lumel.com.pl
ACCESSORIES
Busbar mounting kit:
(delivered with each current transformer)
ACC E S S O R I E S 31
We are one of leading European manufacturers
of electrical devices for automation and high pressure
aluminium castings. We have been on the market since 1953.
We have achieved our high position on the market due
to continuous development policy, competence of our employees
and modern equipment for research, design and production.
Export department:
tel.: (+48 68) 45 75 139, 45 75 233, 45 75 321, 45 75 386
fax.: (+48 68) 32 54 091
e-mail: [email protected]
32 www.lumel.com.pl