INTRODUCTION
Skypatrol offers this information as a service to its customers, to support applications and engineering efforts that use the
products designed by Skypatrol. The information provided is based upon requirements specifically provided to Skypatrol by
the customers and associates. Skypatrol has not undertaken any independent search for additional relevant information,
including any information that may be in the customer’s possession. Furthermore, system validation of this product
designed by Skypatrol within a larger electronic system remains the responsibility of the customer or the customer’s
system integrator. All specifications supplied herein are subject to change.
2
Configuration Utility User Guide
Table of Contents
Contents
Configuration Utility Users Guide ............................................................................................................................................ 2
LEGAL NOTICE .................................................................................................................................................................................. 2
INTRODUCTION ....................................................................................................................................................................... 2
Materials Needed to Perform the Configuration Utility ...................................................................................................... 4
1.1. Windows Based PC ....................................................................................................................................................... 4
1.2. USB Configuration Cable ............................................................................................................................................... 4
1.3. GPS Vehicle Tracking Device ......................................................................................................................................... 4
1.4. Configuration Utility Program ............................................................................................................................................. 5
System Requirements for PC ............................................................................................................................................... 5
2.1. Configuring the Communications Port ............................................................................................................................... 6
2.2 The Program Section ....................................................................................................................................................... 8
Tab “Device” ........................................................................................................................................................................ 8
3.1. Sub-Tab “Software” ...................................................................................................................................................... 8
3.2. Sub-Tab “Hardware” .......................................................................................................................................................... 13
3.3. Sub-Tab “Command List Profile” ................................................................................................................................ 17
Tab “Connectivity”............................................................................................................................................................. 19
4.1. Sub-Tab “General Setting” .......................................................................................................................................... 20
4.2. Sub-Tab “GPRS Server” ............................................................................................................................................... 22
4.3. Sub-Tab “SMS Server” ................................................................................................................................................ 25
4.4. Sub-Tab “USSD Server”............................................................................................................................................... 26
4.5. Sub-Tab “User SMS” ................................................................................................................................................... 27
4.6. Sub-Tab “SMS Forwarding”......................................................................................................................................... 31
Tab “Event” ........................................................................................................................................................................ 31
5.1. Sub-Tab “Event Mask” ................................................................................................................................................ 31
5.2. Sub-Tab “Combination Event” .................................................................................................................................... 32
5.3. Sub-Tab “Device Reaction” ......................................................................................................................................... 33
Tab “I/O Port” .................................................................................................................................................................... 35
Tab “Geo-Fence”................................................................................................................................................................ 40
7.1. Sub-Tab “General”.............................................................................................................................................................. 40
7.2. Sub-Tab “Draw Geo-Fence” ........................................................................................................................................ 41
7.3. Sub-Tab “Geo-Fence Config” ...................................................................................................................................... 42
Tab “Voice” ........................................................................................................................................................................ 42
Tab “Exclusive” .................................................................................................................................................................. 44
9.1 Sub-Tab “G737IC” ........................................................................................................................................................ 45
9.2 Sub-Tab “G79W”.......................................................................................................................................................... 49
Tab “Debug & Upgrade”.......................................................................................................................................................... 51
10.1. Sub-Tab “Command Line”......................................................................................................................................... 52
10.2. Sub-Tab “Printed Log Type"............................................................................................................................................. 52
10.3. Sub-Tab “Firmware Upgrade” ...................................................................................................................................... 53
3
Configuration Utility User Guide
4
Configuration Utility User Guide
When launching the Configuration Utility Program the following window will be displayed.
Please note: if the USB driver has been successfully installed the utility program will launch when
“Auto Conn” is being checked. The USB com port will automatically be recognized and the Utility will read the IMEI
number of the GSM Module inside of the unit. Further, if the SIM Card is also installed in the device, it will also be read
and be displayed at the lower left side of the “device connection” Window as illustrated below.
5
Configuration Utility User Guide
Access Setting
Access Setting
Serial Port: COM Port selection here.
Baud Rate: Default Baud Rate is 9600.
Device Model: The Device Model will automatically be read and displayed
here, configuration items will be dynamically loaded accordingly.
Unit System: Switching between metric and US unit system.
Password: Input new password here, default is 0123456789.
Connect: Establish connection between software and device.
Disconnect: Disconnect device and will release the occupied serial port.
Assistant Assistant
All: Select this to check mark all commands in utility.
Auto Conn: Unselected by default, check to automatically connect.
Device Information Device Name: Model name of the device that is currently connected.
SIM Card: If SIM card is recognized by device then MCC and MNC is
available here.
6
Configuration Utility User Guide
3. Tab “Device”
The First Tab is programming the main device features.
Icon Description
Check box: Is ahead of each command. Please left click on the box in front of the command with your mouse
cursor when needing to “Read” current command settings, or to “Write” new command settings.
On each Sub-Tab there are 3 buttons on the bottom of the page, please note they will only “Read or Write” the
current tab.
7
Configuration Utility User Guide
Command NAM
Example: This is an example of how the NAM command is used to change the device name in the report message
to USER (SMS) and the data string to the SERVER.
Default name is the unit connected like the G6S. You can change the name of the device if needed.
Command OPW
The default OEM password “0123456789” is used for connecting the device with the configuration tool. If a user wants to
change the OEM password every time a device connects with the configuration tool it will ask for the password, which can be
entered into the password window. Changing the default password will keep the device secure from someone
attempting to change device settings without proper authorization.
8
Configuration Utility User Guide
Command TZN
This command is used for setting the time zone location for the device during installation.
Example:TZN;8:00
Device TIM:14.11.17-01:19:44
Time
SMS G6S V2.13
LTM 2014-11-17 09:19:44
GPS 0.70/63/10/13
N23.164524
E113.428784
SPD:0km/h 0
GSM -52dBm
Ext_Pwr=13.84V
BAT=3.02V
#2
Command STO
This command is used for enabling the Daylight Savings Feature for use with the device.
Command DST
These commands are used to adjust the time information. Example: in report message, e.g.
Daylight Savings Time: It is the practice of advancing clocks during the lighter months so that evenings have
more daylight and mornings have less. Typically clocks are adjusted forward one hour near the start of spring and are
adjusted backward in autumn.
In the case of the United States where a one-hour shift occurs at 02:00 local time, in spring the clock jumps
forward from the last moment of 01:59 standard time to 03:00 DST and that day has 23 hours, whereas in
autumn the clock jumps backward from the last moment of 01:59 DST to 01:00 standard time, repeating that
hour, and that day has 25 hours. A digital display of local time does not read 02:00 exactly at the shift to
summertime, but instead jumps from 01:59:59.9 forward to 03:00:00.0. In the European Union, on the other
hand, since the shift occurs at 01:00 UTC, the autumn shift happens an hour later than the spring shift, local
time.
9
Configuration Utility User Guide
Command MGE
This command works with the odometer counter feature. The device will accumulate distance based on GPS
signal and the motion sensor status. (This will also avoid GPS drifting when the vehicle is stopped). This is set to
off by default. Selecting yes will enable this feature.)
Command BTN
[ G7F ]
You can use the button to “Dial or Answer a CALL”. Or use it as SOS button
Command SOS
[ G737IC ]
This command is used to enable the button on the G737IC as SOS or power. If it is set for No then this
button will be used to power the device ON and OFF. If the button is used for SOS then it can only be
used for SOS.
[ G7S, G7F ]
This command is used for models (G737IC, G7S, and G7F) which have a physical button to trigger an
“SOS” event.
Command BUZ
[ G77,G79,G7S,G7F ]
This command is used to turn the buzzer sound in the device on or off.
Command ETO
10
Configuration Utility User Guide
This command is used when attaching the engine running hour counter feature; the device will accumulate engine
hours based on a digital input pulse.
Command MGS
Enter the initial value of the odometer in meters. The device will accumulate distance in meters based on the initial
entered value. The incremental value can be queried at any time thereafter.
Command ETS
This command will specify which one of two digital inputs for the device as “Engine Starts” signal input, only if the
input is triggered will the device start to accumulate data based on a pre-set engine hour, and this command is also for
querying current engine hours, similar to the example of the command for the MGS above.
Please note: only two inputs are available here, IN3 or IN4. The user can select any one of these inputs
whichever he is going to use as engine sensing wire, and please set them as digital by command AIM first.
IN3: High level active (>5V) IN4: High level active (>19V)
Command SPO
This command is used to set a trigger condition for an over speed event.
Disable: Disable the over speed event detection.
Enter the Speed Range: Only current speed entering pre-set speed range to trigger an event.
Leave the Speed Range: Only current speed leaving pre-set speed range to trigger an event.
Enter or Leave the Speed Range: Current speed leaving or entering pre-set speed range will trigger an event.
10
Configuration Utility User Guide
Command SPS
Command PPS0
This command will set the GSM module for power saving mode, when “yes” is selected, the device will go into power
saving mode according to the below setting:
Unregister threshold: Device cannot register to a GSM network over 5 minutes will go to power saving mode.
No data transmission threshold: Device is registered to a GSM network but has not had any data transmit activity for
over 5 minutes and will then go into to power saving mode.
Awake interval: The device will wake up from sleep at such interval.
Note: The GSM module only wakes up when the interval timer is up, or a certain event is triggered (precondition happens
when the last GPRS connectivity is valid before device enters power saving, otherwise it will not wake up instantly).
Command PPS1
This command is to used set the GPS module for power saving mode, definition is similar to GSM module.
GPS un-fixed threshold: Is the value that the GPS module will use to actively attempt to acquire satellite position before
the module will shut down.
Awake interval: Is the value that can be set so that GPS module wakes up from sleep periodically.
Note: If the device goes to “parking” status with GPS fix, the GPS module will sleep instantly, if device goes into
“parking” without GPS fix, it will wait for “GPS un-fixed threshold” to sleep.
11
Configuration Utility User Guide
Command PPS2
[ G737IC ]
This command is used to set a the power save mode of the RF Module for the G737IC.
To enable the power save mode for the RF module select the Yes radio button and set the working time and sleeping
time.
Working Time: is the value in seconds the RF module will work or turned ON.
Sleeping Time: Is the value in seconds the RF module will not work or sleep.
Command PVM
G6S/G3S
This command is used to setup 3 possible work shifts of “Private Hour Periods”
Disable: If you disable this feature, the packet to the SERVER will readjust according to regular setting.
Full manual: The digital input channel must be specified for this mode, if digital input is triggered (Example: a switch
button is connected), the device will switch to private hour mode, it will report packet without current GPS/GSM
position to a SERVER.
Half manual: Digital input channel must be specified for this mode, if digital input is triggered (Example: when a
switch button is connected and pressed on), and current time is inside private hour, the device will switch to private
hour mode, it will report data string without current GPS/GSM position to SERVER, otherwise it reports as usual.
Automatically: Regardless of digital input, device will go to private mode only referring private hour period setting,
during private hour period device will report data string without GPS/GSM position to SERVER.
Private activity monitoring: The device will go to private activity monitoring mode only referring private hour
period setting, during private hour period device will force to report packet with GPS/GSM position and device
status to SERVER. It is to monitor after hour movement of the equipment (vehicles).
According to above “private hour period on working day” setting, private hours will be:
Saturday and Sunday: Whole day.
12
Configuration Utility User Guide
Monday to Friday: During 00:00 to 09:00, 12:00 to 13:30, and 17:00 to 23:59.
Command POB
[G6S]
This command is used to toggle a digital output when private hour mode is activated, for a Definition of “mode” please
refer command DIM in tab “I/O Port”.
Digital output channel: Specifies which output port.
Interval: Interval between each output the interval time is in Seconds and rage is 0-65535.
Command ECL0
[G6S]
eCall is a European initiative intended to bring rapid assistance to motorists involved in a collision anywhere in
the European Union. The eCall initiative aims to deploy a device installed in all vehicles that will automatically
dial 112 in the event of a serious road accident, and wirelessly send airbag deployment and impact sensor
information, as well as GPS coordinates to local emergency agencies.
This command is usedfor setting the ecall phone number of the agency to be contacted in the event an
emergency has happened.
Note: This information cannot change.
Command ECL1
[G6S]
This command is used for setting the vehicle identification number “VIN” of the vehicle that the unit is installed
in.
Command ECL2
[G6S]
This command is used for various inputs or events to trigger an automated eCall.
13
Configuration Utility User Guide
Command STP
This command is used to set criteria for parking status after device stops.
Threshold: If device’s stop duration over is this value, it will go from stop status to parking status.
Command PTH
This command is used to set threshold value for power supply event.
External power threshold: If the external power supply voltage drops to below 8 volts and last for 10 seconds, a power supply
event is triggered.
Backup battery threshold: If backup battery voltage drops to below 2.5 volts and last for 10 seconds, a power supply event is
triggered.
14
Configuration Utility User Guide
Command BMO
This command will turn on or off the harsh driving behaviors detection feature.
Command BMS
This command is to set the acceleration magnitude value threshold for harsh behavior, these values must be carefully
calibrate according to your practice, and otherwise please keep the factory default settings.
Note: We strongly recommend not changing the Motion Status Acceleration Magnitude and Move to
stop threshold. These figures had been adopted after extensive testing.
Command AMO
This command will turn On or Off the accident event detection function.
Command AMS
This command sets the acceleration magnitude value threshold for harsh behavior. These values must be carefully
calibrated, otherwise please keep the factory default setting. Also the device is able to identify front/rear collision in the event
report if an accident has occurred.
15
Configuration Utility User Guide
Command BDS
[G6S/G3S/G3A]
This command is used to adjust the accelerate meter according to practical device installation direction, on the device
sticker notice the default installation direction (left) must point to the engine, which means the left side of the device
must point to the direction the vehicle is heading. If your installation requires another side point for vehicle heading
please change the default setting here accordingly.
Command AGP
This command is used to toggle A-GPS feature for GPS module, if enabled it helps GPS to fix faster, and please note this
feature requires GPRS connectivity and will consume GPRS data flow.
Command ILO
This command can enable the vehicle idle status detection feature.
16
Configuration Utility User Guide
Command ILS
This command is used to set criteria for idle status detection, the device will refer to “ACC status & motion status &
GPS speed” to decide if the vehicle is under idle or not.
Enter idle threshold: Threshold to enter idle status, if ACC is ON, the motion sensor status is moving, and GPS speed is
0, above status duration over 30 seconds, the vehicle will be considered as idle.
Quit idle threshold: Threshold to quit from idle status, i.e. if the vehicle is under idle already, and ACC goes to
OFF or there is GPS speed, above status duration over 30 seconds, the vehicle will be considered quitting idle
Command GPO
This command used is to toggle the GPS and GSM module, please note if “No” is selected, GSM/GPS/RF Module
connectivity will be disabled.
Command HOP
This command is used to set criteria of discarding GPS position according to HOP value.
Example: The device will not report the packet to the server if the HDOP value is higher than 3.00 automatically, it will
only send the GPS Data as this with All zeros GPS:V;0;N0.000000;E0.000000;0;0;0;0.00;0.00
Command JAM
This command enables GSM module Anti-Jamming detection feature. The mobile phone jammer is an instrument
used to prevent a device from receiving signals from base stations, if “Yes” is selected when a jamming happens the
devices will report a GSM jamming event.
17
Configuration Utility User Guide
Command JMP
GSM RSSI threshold: GSM signal strength threshold to decide being jammed or not, range “20 to 50”.
Enter jamming counter: device will compare current RSSI with “RSSI threshold”, if bigger than “RSSI threshold”,
counter will accumulate 1, otherwise not. When the counter value over “enter jamming counter”, device considers
itself being jammed, range “5 to 600”.
Leave jamming counter: device will compare current RSSI with “RSSI threshold”, if small than “RSSI threshold”,
counter will accumulate 1, otherwise not. When the counter value over “Leave jamming counter”, device considers
itself not being jammed, with a range of “30 to 250”.
Command TOW
Command EPM
[G6S]
Data type:
“Disable” :Serial port of device will be disabled.
“Transparent mode 0”: data from device to peripheral will be raw, data from peripheral to device will be stuffing with
protocol.
“Transparent mode 1 interval”:data from device to peripheral will be raw, data from peripheral to device will be stuffing with
protocol, “interval” is the interval time to buffer serial port data on device.
“GARMIN” this mode is for GARMIN PND
“External GPS input source” device will use external GPS input as source instead of its original
“MDT Mode”
“iData RS Mode”
18
Configuration Utility User Guide
Command ITS
[G6S]
The command is used to set up a serial port command for serial device in the event of trigger.
Even ID: select the input to trigger the command
Interval: this is the interval set to send the command to the serial device.
Times: how many times you want to send the command.
Format: HEX or ASCII
Serial Port Command: input the command in HEX or ASCII format based on your selection in the
format.
Command PKI
[G6S]
Command EPT
This command is used to set only enabled serial port periodically by referring to ACC status.
[G6S]
ACC ON interval: if ACC is ON, the device will extract data from the serial port every 30 seconds, serial data between
intervals is not accepted by device.
ACC OFF interval: if ACC is OFF, the device will extract data from the serial port every 3600 seconds, serial data
between intervals is not accepted by device.
Command EPS
19
Configuration Utility User Guide
[G6S]
This command is for the configuration of the serial port baud rate to communication with peripheral device.
Command YCF
This command is used to ask the device to execute commands from a command list profile that you can create and
save to the device.
Command YSF
This command is used to import command list files for the device to execute automatically when certain conditions are
satisfied. There are 5 command list profile slots available and by default they are empty, you must create a note pad
.txt file with commands and load that file to the device by assigning a profile number to it, and then these profiles will
be available for command FRL to call.
Command YGF
This command will save individually created list profiles from the device to your computer. The file format will
be saved as .txt.
20
Configuration Utility User Guide
Command FRL
This command is specify certain conditions for a device to execute a created command list profile, if multiple
conditions are selected then AND logic is implemented.
Example: If a ACC “ON to OFF” event and a Digital input IN1 “High level or null” are selected and only if both are
triggered, the device will execute commands automatically in command list profile number 5.
Note: If multiple conditions are selected at the same time, the device only if executes a command list profile
when multiple conditions are satisfied simultaneously.
21
Configuration Utility User Guide
Command FRS
This command is used to specify certain conditions for a device to execute a created command list profile, the
difference between command FRL is this command is using OR logic for selected conditions.
Example: If a ACC “ON to OFF” event and a Digital input IN1 “High level or null” are selected and any one of
them is triggered, the device will execute commands automatically in command list profile number 5.
Command SCF
This command is used to save global setting of device as a configuration profile, there are 3 profile slots
available, which means you can configure the device according to different application and switch between
them easily.
Command RCF
This command is used to switch between pre-saved configuration profiles. There are 3 profile slots available.
22
Configuration Utility User Guide
4. Tab “Connectivity”
The Second Tab is for programming the “Connectivity”
Command DNU
[G6S,G3S,G3A,G77,G79,G7S,G7F]
[ G737IC]
[ 2P ]
This command will set the report interval mode switching condition, it is valid for SMS and GPRS fixed time reports.
You will notice that for a SMS report (command SSP, command USP) and a GPRS server report (command SVP) they
have 2 report intervals, “static” and “dynamic” mode.
Example: Suppose we select ACC OFF and International Roaming. This means that the device will change its upload
mode to “dynamic” when anyone of the features are selected. If we select ACC OFF the device will always change its
upload mode to that setting based on the setting to be on or off. If the ACC OFF is off it will be sending a slower rate
and when ACC OFF is on then the data will be sending at a higher rate.
Note: Multiple conditions are supported, and the device will change to “dynamic” mode when any one of them is
satisfied.
23
Configuration Utility User Guide
Command ADM
ADM for G3S,G6S
The device has been designed to adjust the string length based on your own settings. The field has several options
for sending different types of data from the device to the SERVER and USER. There are 8 profiles (ADM0 to ADM7)
available in the dropdown tab. and can be selected to use which profile is created for any report to the SERVER and
USER.
0 (SMS Server) :Selecting this profile will send the string data to the SMS Server.
1(GPRS Server) Note: This is the default profile used by the device sending data to the GPRS Server.
Profiles 2 thru 7 are also sending data to the GPRS Server.
Example: Select the profile you would like to customize for sending preferred data string to the Server. Make selections
by checking or unchecking the box next to the field of choice for the selected profile and “Write” it to the unit.
Select another profile and make your choice of data to send to the Server and “Write” the profile to the device.
You can now select between profiles you have created and “Write” the one you select to the unit.
Command SDM0
This command is to further customize main data type “System Data”, selected sub-data type will be carried.
24
Configuration Utility User Guide
Command SDM1
This command is used to further customize the main data type “GPS Data”, selected sub-data type will be carried.
Command SDM2
This command is used to further customize t h e main data type “GSM Data”, selected sub-data type that will be
carried, please note multiple base station info must be selected in continuous number order from the first base
station info..
Command SDM3
SDM3 for G6S,G3S
This command will further customize main data type “COT Data”, selected sub-data type will be carried.
Command SDM4
SDM4 for G6S,G3S
This command will further customize main data type “ADC Data”, selected sub-data type will be carried.
25
Configuration Utility User Guide
Command SDM5
This command will further customize main data type “Device Status Data”, selected sub-data type will be carried.
Command HBI
This command will set a keep connection live short message interval with GPRS SERVER using TCP/IP and UDP.
Normally most of the GSM server providers have different settings in their network that can drop the connection for
a device that is not connected for a set period of time that is not sending data to the SERVER and will drop the
session. Please set this number according to your network provider’s connection preferences.
Command HTM
This command is used for setting a device self-test “healthy check” message over GPS and SMS to the SERVER. This
can check the device GPS, GSM, Heartbeat Sensor, CPU, and other internal components to ensure the device is
functioning properly.
Command DIS
This command will send a report based on certain travel distance and/or certain degree of angle.
Example: The device will send a report when every 1KM of distance is travelled, and also report if the vehicle heading
has changed over 10 degrees or more based on the input settings. Setting the “Fixed Distance” and “Turning Angle”
to 0 will turn off this function. Setting the “Turning Angle” to 20 will send less data to the SERVER and a lower
number will send more data.
26
Configuration Utility User Guide
Command EFM
This command can record offline data and report its behavior to the SERVER.
The device has a 4Mbit flash memory internal storage for offline data when GPRS is offline.
Enable offline data buffer: If set to “yes” the device will save data to flash memory when GPRS is offline, and report
it to SERVER when GPRS comes back online.
Priority: Specify offline data to report priority when the GPRS comes back online, “offline data prior” means
reporting all offline data to the SERVER as soon as possible, while “real time data prior” means reporting offline
data when device is idle (between real time report interval).
Erase Flash: If “yes” is selected and you click on the “write” button, the flash memory will be formatted.
Command APL
This command is used to specify SIM card according to your location, device has storage various mobile networks
APN information around the world to automatically fulfill APN information once a SIM card is inserted.
: It is for you to review all the supported networks for each country and add more based on your
requirement.
Command APN
This command is for you to input your APN information and also a Name and Password here if required for your
carrier provider.
27
Configuration Utility User Guide
Command SVR
This command is used to setup periodical report to host SERVER, if “disable” is selected device will not report
periodically to SERVER.
IP/Domain: IP address or Domain name is inputted here
TCP port: Specifies SERVER TCP port number.
UDP port: Specifies SERVER UDP port number.
Mode: Specifies data transfer protocol, “TCP command & UDP data” means only command interaction will use TCP,
regular data report will stick with UDP to save on data flow.
ACK packet request from server: “No” device will not require the ACK packet response from server to deliver the
next position packet, “Enable for UDP” when using UDP the device will require ACK packet response from server to
deliver to the next position packet, and “Enable for UDP and TCP” when using UDP or TCP the device will require an
ACK packet response from server to deliver the next position packet.
Command SVT
This command will set a timeout value to the backup SERVER when using ACK is enabled.
Command BSV
This command is used to setup the backup SERVER when the main host SERVER is unavailable.
Command BDU
This command sends the number of records you want to send in 1 packet. Normally if you want real time tracking
you need to select 1. If you want the device to send more data packets to the server increase the value.
28
Configuration Utility User Guide
Command BDU1
This command sends how many records do you want to send in 1 packet. Normally if you want real time tracking
you need to select 1. If you want the device to send more data packets to the server increase the value.
Command SVP0
This command will set periodical “static” report to SERVER, device is able to switch between “static” mode and
“dynamic” mode according to vehicle status change (Please refer command DNU for supported conditions).
Interval: Device will report position interval based on this value.
Unit: Report time unit.
Report mode: “Disable” means that the device will not report to the SERVER. “GPS prior” means that the device will
prefer to report a GPS position when GSM and GPS position information both available. “GPS & LBS” means device
will report GSM and GPS position both to SERVER.
Data format: “Disable” means the device will not generate any data. “HEX” means that the device will generate data
that is coded with HEX. “ASCII” means device will generate data that coded with ASCII.
Command SVP1
This command is used to set a periodical “dynamic” report to SERVER, when the selected conditions in command
DNU are satisfied, t h e device will report according this setting, and otherwise it will stick with “static” mode.
Interval: Device will report position interval based on this value.
Unit: Report time unit.
Report mode: “Disable” means that the device will not report to SERVER. “GPS prior” means that the device will
prefer to report GPS position when GSM and GPS position information both available. “GPS & LBS” means that the
device will report GSM and GPS position both to SERVER.
Data format: “Disable” means the device will not generate any data. “HEX” means the device will generate data that
is coded with HEX. “ASCII” means the device will generate data that is coded with ASCII.
29
Configuration Utility User Guide
Command SSN
This command is used to set a phone number that has Administrator authority, please have the country code
ahead.
Command SSP0
This command is used to set a periodical “static” report to Administrator phone number, the device is able to switch
between “static” mode and “dynamic” mode according to vehicle status change (Please refer command DNU for
supported conditions).
Interval: Device will report position interval based on this value.
Unit: Report time unit.
Report mode: “Disable” means the device will not report to an Administrator phone number. “GPS prior” means
device will prefer to report GPS position when the GSM and GPS position information are both available.
“Periodical voice call” means the device will proactively call an administrator phone number periodically, and if
you pick up the call you can voice monitor the vehicle (microphone installation is required).
Data format: “Disable” means the device will not generate any data. “ASCII” means the device will generate
data that is coded with ASCII.
*
data report:
GS06,351535053545232,063247171114,,SYS:G6S;V2.13;v1.05,GPS:A;11;N23.164530;E113.428680;0;0;28;0.7
0,COT:,ADC:14.23;0.09,DTT:0;E1;0;0;0;1#
Command SSP1
30
Configuration Utility User Guide
This command is used to set periodical “dynamic” reports to an Administrator phone number, when the selected
conditions in a command DNU is satisfied, the device will report according to this setting, and otherwise it will
stick with “static” mode.
Data format: “Disable” means the device will not generate any data. “ASCII” means the device will generate
data that is coded with ASCII.
Command ACM
This command is used to customize command accessibility for an administrator phone number.
Please note that when using this configuration software it is under OEM (OEM>Administrator>User) authority.
Selected commands are open OEM commands for administrator (SMS Server phone number) to use.
31
Configuration Utility User Guide
Command SUR
This command is used to set USSD server address.
Command SUP1
This command is used to set device report interval to host server.
32
Configuration Utility User Guide
Command SUP2
33
Configuration Utility User Guide
Command PIN
This command will set the PIN number for accessibility of the SIM card. Its default is 1234 normally you do not need
to specify it.
Command SIM
Command BLS
This command is a feature that can call a USSD number and you will receive back information on account balance for
prepaid SIM cards.
USSD Command: A protocol used by GSM cellular telephones to communicate with the service provider's computers.
Interval: Here you can set this for you to receive a message every 1 Day or every 5 Days.
Unit: Here you have 3 selections Day/Week/Month and works in conjunction with the interval setting.
Low Balance Threshold: Here you can set the amount of currency to a low balance for notification.
34
Configuration Utility User Guide
Command URL
This command is used to set Google map hyperlink in the report message to USER phone number.
Mode: “GPS” means map API is able to parse according to the GPS position, and “GSM” means map API is able to
parse according to GSM position.
URL: GPS or GSM location parser hyperlink, e.g.: http://maps.google.com/maps?q=%n,%e&t=m&z=16
Command SCN
This command is used to set the server center number, normally leave it as default or consult your network
provider for this information.
Command UCM
This command is used to customize the command accessibility for USER phone number.
Please note that when using this configuration software it is under OEM (OEM>Administrator>User) authority. Selected
commands are open for USER phone number to use.
35
Configuration Utility User Guide
Command UNO0
This command is used to set a USER0 phone number, please have country code available.
Command UPW0
This command is used to set a USER0 command password, default is 1234, it means when you try to send a command
the device must be carrying the right password in command, otherwise the device will not accept.
Example: 1234, VER to query information of device.
Command USP0;0
This command is used to set a periodical “static” report to a USER0 phone number, the device is able to switch between
“static” mode and “dynamic” mode according to the vehicle status change (Please refer command DNU for supported
conditions).
36
Configuration Utility User Guide
Command USP0;1
This command is used to set a periodical “dynamic” report to USER0 phone number, when the selected conditions in
command DNU is satisfied, the device will report according to this setting, and otherwise it will stick with “static” mode.
Interval: Device will report position interval based on this value.
Unit: Report time unit.
Report mode: “Disable” means the device will not report to a USER0 phone number. “GPS prior” means the device will
prefer to report GPS position when GSM and GPS position information are both available. “Periodical voice call” means
the device will proactively call an administrator phone number periodically, and if you pick up the call you can voice
monitor the vehicle (microphone installation is required).
Data format: “Disable” means device will not generate any data. “ASCII” means device will generate data that coded
with ASCII. “URL” means device will report position by using map hyperlink in message.
Command UNO1
This command is to set USER1 phone number, please have country code ahead.
Command UPW1
This command is used to set a USER1 command password, default is 1234, it means when you try to send command to the
device must be carrying the right password in command, otherwise device will not accept.
E.g.: 1234,VER to query version information of device.
30
Configuration Utility User Guide
Command USP10
This command is used to set a periodical “static” report to USER1 phone number, device is able to switch between “static”
mode and “dynamic” mode according to vehicle status change (Please refer command DNU for supported conditions).
Interval: The device will report position interval based on this value.
Unit: Report time unit.
Report mode: “Disable” means that the device will not report to USER1 phone number. “GPS prior” means the device
will prefer to report GPS position when GSM and GPS position information both available. “Periodical voice call” means
device will proactive to call administrator phone number periodically, and if you pick up the call you can voice
monitoring the vehicle (microphone installation is required).
Data format: “Disable” means device will not generate any data. “ASCII” means device will generated data that coded
with ASCII. “URL” means device will report position by using map hyperlink in message.
Command USP11
This command is to set periodical “dynamic” report to USER0 phone number, when the selected conditions in command
DNU is satisfied, device will report according this setting, and otherwise it will stick with “static” mode. Interval: Device will
report position interval based on this value.
Unit: Report time unit.
Report mode: “Disable” means device will not report to USER0 phone number. “GPS prior” means device will prefer to
report GPS position when GSM and GPS position information both available. “Periodical voice call” means device will
proactive to call administrator phone number periodically, and if you pick up the call you can voice monitoring the
vehicle (microphone installation is required).
Data format: “Disable” means device will not generate any data. “ASCII” means device will generate data that coded
with ASCII. “URL” means that the device will report position by using a map hyperlink in message.
30
Configuration Utility User Guide
Command SMT
This command can setup automatic forwarding from a specific number. Up to 3 phone numbers are supported, the device will
forward the message that it receives from these 3 phone numbers to User0/User1/Administrator/GPRS Server.
30
Configuration Utility User Guide
5. Tab “Event”
The Third Tab is programming the “Event”
Command ESM
This command is used to set events for the device to detect, it shows all the events (including single event and combination
event) that are supported with the device, a selected event means that the device will monitor and respond according to
setting when an event happens. Most of the events have two statuses,
31
Configuration Utility User Guide
Example: TOW event. This means that device has 1 status bit flag for TOW, let us suppose for this bit “1”=under TOW,
“0”=Normal (Quit TOW), then:
Status 0 = if “1” change to “0”, device will report/trigger output for this change. Status 1 = if “0” change to “1”, device will
report/trigger output for this change. Same manner for the rest of events.
Thee above setting means that the device will report to USER/Administrator/SERVER (GPRS) or trigger output when the
vehicle is entering TOW status, but will ignore (not report/trigger any) when the vehicle is leaving TOW status.
Event report clear type: “automatically” means after the report times are finished, then the device will automatically reset an
event report bit flag to 0.
“Manually” means the opposite way that you need to send a command to reset event report bit flag to 0.
32
Configuration Utility User Guide
This command is used to define a combination event, it is able to bind multiple single events (up to 5 single events and
please note that status0 and status1 from identical event cannot be selected simultaneously) as a combination event,
and only if all single event flags are active then combination event is active, i.e. It is using “AND gate” logic.
Example: the above setting will cause Comb1 will activate only if vehicle is over speeding and crossing pre-set GEO-
fence.
33
Configuration Utility User Guide
Command EUP
This command is used to specify the output wave shape, and it corresponds with “Trigger I/O port action” from command
EUP above.
Digital output channel ID: Specify which output port.
Status 0 output mode: Specify wave shape when event is under status 0.
Status 1 output mode: Specify wave shape when event is under status 1.
After event clearance output mode: Specify wave shape when event report bit flag is reset.
Command EUC
34
Configuration Utility User Guide
Command EOB
This command is used to specify output wave shape, and it is corresponding with “Trigger I/O port action” from command
EUP above.
Digital output channel ID: Specify which output port.
Status 0 output mode: Specify wave shape when event is under status 0.
Status 1 output mode: Specify wave shape when event is under status 1.
After event clearance output mode: Specify wave shape when event report bit flag is reset.
35
Configuration Utility User Guide
Command ENM
By default Customization
G6S V1.00 G6S V1.00
LTM 2013-02-28 23:51:09 LTM 2013-02-28 23:51:09
GPS 1.55/0.50/3/4 GPS 1.55/0.50/3/4
N23.164302 N23.164302
E113.428456 E113.428456
SPD:0km/h 0 SPD:0km/h 0
ETD:28/ACC ON ETD:28/ACC OFF
GSM -52dBm GSM -52dBm
Ext_Pwr=12.13V Ext_Pwr=12.13V
BAT=3.96V BAT=3.96V
#28 #29
36
Configuration Utility User Guide
Command AIM
Command AIR
Command DOM
This command is used for configuration of digital output wave shape. Channel ID: Specify which output port.
Mode: Rising edge. Duration: 10000ms
It means it is going to take 10 seconds to rise from low level to high level, could be like:
37
Configuration Utility User Guide
Mode: Square wave 1 to Square wave 4, they are having same parameter, e.g.:
Command DOP
38
Configuration Utility User Guide
Command DIM
This command is used to set the wave shape trigger conditions of digital inputs. Mode:
“Level”:
It means any input level switching will trigger input (IN) event.
“Frequency meter”:
“Lower limit” and “upper limit” are used to specify input frequency range, outside range will trigger input (IN) event.
“Pulse meter”:
“Initial meter value” means that the device will accumulate a pulse number based on this value. “Meter value threshold”
means surpassing this value will trigger input (IN) event.
“Low level”:
“Duration” means the input is switching from high level to low level, and keeps low levels over this duration will trigger
input (IN) event.
Example: DIM is set as above, and let us suppose IN3 is connecting with a high level signal at the beginning. IN3
“status0: high level to low level” event will be triggered if:
Signal high level goes to low level and last over 10000ms (10 seconds).
“High level”:
“Duration” means input switching from low level to high level, and keeping a high level over this duration will trigger
input (IN) event.
Example: DIM is set as above, and let us suppose IN1 is connecting with a high level signal at the beginning. IN1
“status0: low level to high level” event will be triggered if:
Signal high level goes to low level, then low level goes back to high level again and last over 5000ms (5 seconds).
“Rising edge”:
“Initial meter value” means that the device will accumulate rising edge number based on this value. “Meter value
threshold” means surpassing this value will trigger input (IN) event.
“Failing edge”:
39
Configuration Utility User Guide
“Initial meter value” means that the device will accumulate failing edge number based on this value. “Meter value
threshold” means surpassing this value will trigger input (IN) event.
“Edge”:
“Initial meter value” means device will accumulate rising and failing edge number based on this value. “Meter value
threshold” means surpassing this value will trigger input (IN) event.
Note:
IN1 & IN2 are low level (GND) active.
IN3 & IN4 are high level active, IN1 >6V, IN4 >19V.
Command ADS
Command ATH
Command IBO
[G6S]
40
Configuration Utility User Guide
Command IBP
[G6S]
Command TMP
[G6S]
This command is to set temperature range event, only valid when command IBO set as “Temperature sensor”.
Lower limit & Upper limit: Set temperature range, outside this range will trigger 1-WIRE temperature event report.
Duration time: Temperature outside this range over this duration will trigger event.
Command IBE
[G6S]
Command IBS
[G6S]
41
Configuration Utility User Guide
Command IBI
[G6S]
This command is used to save the iButton ID as legal iButton, up to 16 IDs is supported.
Command IBC
[G6S]
42
Configuration Utility User Guide
7.Tab “Geo-Fence”
The fifth tab is for programming the Geo-Fence
7.1.Sub-Tab “General”
General: is the first sub tab for programming the device.
Command GOF
This command is for setting the Geo-fence mask. The device supports up to 156 Geo-fences by default only the first
16 are enabled. Check mark the All box then write to the device will enable all 156 Geo-fences for you to setup and
use, or select them individually.
Note: The first 28 can use the Polygonal, Rectangular, and Circular Geo-fences. The Next 29 to 156 can only use
the Circular Geo-fences and you can set them up more than 100 meters.
40
Configuration Utility User Guide
Command UFM
This command is used to open a Geo-fence for a USER to use, checked box means it is open to USER0 and USER1.
41
Configuration Utility User Guide
42
Configuration Utility User Guide
This command is used to set the time range restriction for Geo-fence event detecting on daily basis.
Example: For Geo-fence number 1, it is only valid during 08:00 to 12:00, 13:00 to 18:00, 1900 to 22:00 on Monday to Friday
Command GFS
This command is used to set speed range restriction for Geo-fence detecting.
Type: “Invalid” means this feature is disabled. “Inside range” means if the vehicle inside the speed range Geo-fence number
1 event will be triggered. “Outside range” means if the vehicle outside of speed range Geo-fence number 1 an event will be
triggered.
Min Speed” & “Max speed: Define speed range.
43
Configuration Utility User Guide
8. Tab “Voice”
VOICE SECTION:
Command PWL
This command is used to modify the phone number list that authorized to use voice related features of device, 16 phone
numbers are supported, and please note that microphone and speaker installation is needed.
Command MWL
This command is to specify which phone number from above command PWL to have authorization of voice monitoring,
which means when phone number 1 “123456” from PWL calls, device will pick it up and enable microphone of device
(Speaker disabled), and you can hear from vehicle.
Command HWL
This command is to specify which phone number from above command PWL to have authorization of hotline, which means
when phone number 2 “1234567” from PWL calls, device will pick it up, and enable microphone & speaker of device for
conversation.
44
Configuration Utility User Guide
Command QWL
This command is used to specify which phone number from the above command PWL will have the authorization of an
inquiry position, which means when phone number 3 “12345678” from PWL calls, the device will not pick it up, but will
reply with a message with the current position.
Command SWL
This command is to specify which phone number from above command PWL to have authorization of SOS, which means
when the Panic button is pressed, the device will call phone number 4 “12345678” from PWL automatically.
Command VOE
G6S/G3S
G77/G79
G7S/G7F
45
Configuration Utility User Guide
Command AGN
G6S/G3S/G7S/G7F
G77/G79
This is for setting up values for microphone gain and speaker gain.
46
Configuration Utility User Guide
9. Tab “Exclusive”
EXCLUSIVE SECTION:
Command TAG
This command is to bind Tag with G737IC, G737IC has capacity to bind up to 250 Tags in total.
Tag ID: Select Tag ID slot to bind a Tag, range from 0 – 124.
Specify Tag type: Specify the Tag type here to bind here, home tag or prison tag, each type has 125 slots capacity.
Clear Tag serial number: Unbind specific Tag from G737IC according to selection slot of “Tag ID”.
Enable Tag entering and leaving event report: Toggle event report when G737IC seeing/no seeing Tag in range.
Tag Serial number: Enter serial number of Tag to bind it with G737IC.
Example: Home tag with serial number 01.02.03.04.05 will be bind with G737IC in slot #1, G737IC will report when
Tag is entering/leaving its signal range.
Command CTA
This command will clear all Tag data settings from the G737IC
47
Configuration Utility User Guide
Command SCS
This command is used to set an error timeout for switching between 2 SIM cards.
Timeout: If the current SIM card has communication error over this period, device will switch to another SIM card
automatically.
Example: If the current SIM card is working abnormally over 5 minutes, G737IC will switch to another SIM card.
Command DSS
Command MTC
48
Configuration Utility User Guide
Command LCM
If set as “GSM Status indicator” and lock status, SYS LED: Charging, SYS LED blinks every 1 second Charging, SYS LED ON
constantly
Discharging, SYS LED blinks every 5 seconds
Discharging and voltage low: SYS LED blinks every 5 seconds twice quickly in a row Discharging and voltage under: SYS LED
blinks every 5 seconds 3 times quickly in a row
Command LCK
Command FOC
49
Configuration Utility User Guide
Command CFO
Command PMC
Command TBT
If G737IC misses 5 packets from Tag constantly Tag leaving event will be triggered.
50
Configuration Utility User Guide
Command TTC
Command CTG
This is a “read” only command that is used to check how many pair slots remain available.
Tag type: Specify which Tag type to check.
Next valid Tag slot number: Here shows the next valid slot to save Tag serial number, in ascending numerical order.
Remaining Tag slot counter: Here shows how many available slots in total for each kind of Tag.
Example: For home tag the next valid slot number 10 is valid to save Tag serial number, 114 slots in total remaining.
Command WTP
51
Configuration Utility User Guide
Command BME
This command is used to toggle motion detection and body gesture detection features.
Enable 3 axis sensor for motion detection: “Yes” means motion detecting is enabled, “No” means motion detecting is
disabled.
Enable body gesture detection: “Yes” means body gesture detecting is enabled, “No” means body gesture detecting is
disabled.
Command BMT
This command is used to set up criteria of motion and body gesture detection.
Stop/Moving shift acceleration magnitude: Acceleration threshold for motion detection.
Stop/Moving shift duration threshold: Duration threshold for gesture detection.
Standing/Lie down shift acceleration magnitude: Acceleration threshold for gesture detection.
Standing/Lie down shift duration threshold: Duration threshold for gesture detection.
50
Configuration Utility User Guide
Command SPC
This command is to select data source the speed data in packet
Source: “Automatically” means OBDII speed is preferred, if invalid switch to GPS speed automatically, “OBDII”
means force to use OBDII regardless of its validity, “GPS” means force to use GPS regardless of its validity.
Command OBP
This command is to setup OBDII report data type from vehicle OBD interface, up to 16 customize PIDs are
supported.
OBPx: Specify mode and PID according to protocol SAE standard J/1979.
Fuel coefficient: Specify the current fuel type for proper calibration of fuel consumption reading.
OBP16 is used to set the oil L/Gallon mass transfer coefficient, that is, per liter or gallon of fuel quality. Range: 0-
4294967295, g. Settings can be queried by the FUC command after l or Gallon of fuel consumed. For example: 90#
the density of gasoline is 0.722kg/L, then the setting should be OBP16;722 93# the density of gasoline is 0.725kg/L,
then the setting should be OBP16;725 93# the density of gasoline is 0.737kg/L, the density setting should be
OBP16;737 diesel is the 0.835kg/L, the density setting is for OBP16;# diesel is the 0.840kg/L, the setting should be
OBP16; # Diesel oil density is 0.843kg/L, then the setting should be OBP16;843Example: OBP0 set as 010C device
will extract “Engine RPM” from OBDII interface (if supported) and carry it on packet to server, same manner on
others setting:
010A is “Fuel pressure”, 03 is “DTC error code”, 012F is “Fuel level input”, Octane 98# fuel coefficient is 11025.
50
Configuration Utility User Guide
Command OBA
Service mileage:
Command FCI
50
Configuration Utility User Guide
This command is used to set the fuel consumption initial value before installing the device, afterwards the device will
accumulate mileage based on this preset value and report to the server.
Parameter: If you current fuel consumption is 150L, using Octane 98#, the value to fill here should be 150*11025 = 11653750
Range: 0-4294967295g
Command MGC
50
Configuration Utility User Guide
Command BMC
Command PSS
Command LED
Command GFS
51
Configuration Utility User Guide
The command line terminal is used to manually input any command from the skypatrol protocol. You can read back
current command settings and you also have the ability to make command changes here in the terminal for the device.
Example: In the screen above the user typed command VOE in the terminal and after pressing enter the value stored in that
register will display on the screen. The command APN here was initially set to APN:sl1.korem2m.com and was changed by
inputting preferred changes with the command name first then semicolon to separate the individual changes
APN;skypatrol;guest;guest.
52
Configuration Utility User Guide
With this utility you have the ability to read various data strings directly from the connected unit and also save it to a log file
for later viewing.
Printed Log Type (UGP): This mode is to print real time packet in the debug window.
NULL: This is zero for no log.
GSM (AT+): The GSM module communicates with AT protocol command string.
GPS (NMEA): This item reads the GPS NMEA protocol command string.
Tracker: This item reads directly from the MCU of the tracker.
Read:
Write: Click on write to activate selected drop down setting.
Exit: Click to exit the debug mode you are currently working with.
Save: Click on save to write the data to a log file and save on the computer.
53
Configuration Utility User Guide
This command is used for a local firmware upgrade of your device. Click on “Select File” and use the file browser to
find the upgrade file, then click on “Upgrade” to start. Once the firmware upgrade has been completed the unit will
reboot itself to finish the process.
54