Carbon Dioxide/Temperature Transmitter: Ndir Co Sensor, Universal Outputs, Optional Relay
Carbon Dioxide/Temperature Transmitter: Ndir Co Sensor, Universal Outputs, Optional Relay
AIR QUALITY
SERIES CDT
CARBON DIOXIDE/TEMPERATURE TRANSMITTER
NDIR CO2 Sensor, Universal Outputs, Optional Relay 1.10
[27.96] .552
YEAR LIMITED
WARRANTY
[14.02]
2x .176
[4.47]
4.50 3.000
[114.30] [76.20]
.573
[14.56]
2.80
[71.12] 1.08
[27.33] 1.18 1.16
[30] [29.39]
3.65 .33
[92.72] [8.38] 3x .15
3x .37 [3.87]
European Style North American Style [9.36]
3.56
[90.42]
4-25/32˝ 11-49/64˝
1/8˝ [121.612] [298.956]
[3.175] 1-15/64˝
4-9/32˝ [31.411]
[108.912] 2-13/16˝
[71.238]
VIDEO ON
LI
NE
Duct Ø3-5/16˝
[84.074]
The SERIES CDT Carbon Dioxide and Temperature Transmitters accurately monitor SPECIFICATIONS
the CO2 concentration and temperature in indoor environments to help achieve Sensor: Single beam, dual wavelength NDIR.
energy savings. For increased sensor accuracy, a single beam dual wavelength non- Range: CO2: 0 to 2000 or 0 to 5000 ppm (depending on model); Temperature: 32 to
dispersive infrared (NDIR) sensor is used to automatically correct the measurement 122°F (0 to 50°C).
in both occupied* and unoccupied buildings against light source aging effects. The Accuracy: CO2: ±40 ppm ±3% of reading; RH: ±2% (10 to 90% RH); Temperature:
single beam dual wavelength sensor technology provides the highest level of accuracy ±1°C @ 25°C.
compared to Automatic Baseline Correction methods which can unintentionally shift Temperature Dependence: ±8 ppm/°C at 1100 ppm.
the calibration based on CO2 levels and barometric pressure conditions. In order to Non-Linearity: 16 ppm.
achieve a higher level of accuracy, the Series CDT includes digital barometric pressure Pressure Dependence: 0.13% of reading per mm of Hg.
adjustment and the ability to field-calibrate the sensor. Response Time: 2 min for 99% step change.
For applications that require visual indication, the wall mount configurations of the Duct Air Velocity Range: 0-4000 FPM (20.32 m/s).
Series CDT can be ordered with an integral LCD display. Push buttons are standard on Temperature Limits: 32 to 122°F (0 to 50°C).
all configurations of the transmitters for access to the menu structure, but wall mount Humidity Limits: 10 to 95% RH (non-condensing).
Carbon Dioxide
configurations can be ordered without the buttons. To prevent tampering, the action of Power Requirements: 16 to 35 VDC or 19 to 28 VAC.
Transmitters
the buttons can be locked out using an internal dip switch selection. Power Consumption: Average: 2 w; Peak: 3.75 w.
Output: Current: 4 to 20 mA (max. 500 Ω); Voltage: 0 to 5 VDC or 0 to 10 VDC
FEATURES/BENEFITS (min. 500 Ω); Relay: SPST NO rated 2 A @ 30 VDC.
• Single beam dual wavelength NDIR sensor eliminates draft due to light source aging Weight: 4.4 oz (125 g).
• Integral passive temperature outputs reduce number of devices mounted in the Enclosure Rating: Duct mount: NEMA 4X (IP66) for housing only; Wall mount:
space IP20.
• Service display tool available for models without an integral LED Agency Approvals: CE.
• Optional integral display and relay output
APPLICATIONS
• Demand control ventilation in schools, office buildings, hospitals, and other indoor
environments
• LEED® certification