Xfmea Report Sample - Design FMEA: in Addition To This Summary, This Report Includes The Following Forms
Xfmea Report Sample - Design FMEA: in Addition To This Summary, This Report Includes The Following Forms
Page 1 of 6
• A summary of the rating criteria (Severity Scale, Occurrence Scale, Detection Scale) and
classifications that were used in the analysis.
• The Design FMEA (DFMEA) spreadsheet report in the SAE J1739 reporting format.
• A summary list of the recommended actions identified during the analysis.
• A summary list of the current controls identified during the analysis.
The report is based on the sample analysis provided in the SAE J1739 guidelines, on page 37.
Page 2 of 6
Page 3 of 6
Action Results
Classification
Potential Potential Current Design Current Design
Potential Failure Recommended Responsibility & Planned
RPNi
OCCi
DETi
SEVi
Name / Function Effect(s) of Cause(s) of Controls Controls Actions Taken &
RPNr
OCCr
DETr
Mode Actions Completion Date
SEVr
Failure Failure (Prevention) (Detection) Actual Completion
Date
Insufficient room 4 Drawing evaluation 4 112 Add team evaluation Body Engrg & 7/2/2015 Evaluation showed 1 1 7
between panels for of spray head using design aid Assy Ops adequate access.
spray head access. access. buck and spray - 7/2/2015
head.
Page 5 of 6
Action # Recommended Actions Planned Completion Date Responsibility Actions Taken Name Name (Cause) Priority
1.1.1.1.1 Add laboratory accelerated corrosion testing 6/29/2015 A. Tate Body Engrg Based on test results (Test Front Door L.H Upper edge of protective wax Medium
No. 1481) upper edge spec application specif...
raised 125mm.
1.1.1.2.1 Add laboratory accelerated corrosion testing. 6/30/2015 A. Tate Body Engrg Test results (Test No. 1481) Front Door L.H Insufficient wax thickness Medium
show specified thickness is specified
adequate.
1.1.1.2.2 Conduct Design of Experiments (DOE) on 7/1/2015 A. Tate Body Engrg DOE shows 25% variation in Front Door L.H Insufficient wax thickness Medium
wax thickness. specified thickness is specified
acceptable.
1.1.1.4.1 Add team evaluation using production spray 7/2/2015 Body Engrg & Assy Ops Based on test, additional Front Door L.H Entrapped air prevents wax Medium
equipment and specified wax. vent holes will be provided in from entering corner...
affected areas.
1.1.1.6.1 Add team evaluation using design aid buck 7/2/2015 Body Engrg & Assy Ops Evaluation showed adequate Front Door L.H Insufficient room between Medium
and spray head. access. panels for spray head...
Page 6 of 6
Line # Current Design Controls Control Type Name Name (Function) Potential Failure Mode Potential Effect(s) of Failure Potential Cause(s) of Failure
1 Vehicle general durability test veh. Detection Front Door - Ingress to and egress Corroded interior low door panels Deteriorated life of door leading to: Upper edge of protective wax application
T-118 L.H from vehicle.-- Occupan... - Unsatisfactory appearance due to rust specified for inner door panels is too low.
T-109 through paint over time.
T-301 - Impaired function of interior door
hardware.
2 Vehicle general durability testing - as Detection Front Door - Ingress to and egress Corroded interior low door panels Deteriorated life of door leading to: Insufficient wax thickness specified
above. L.H from vehicle.-- Occupan... - Unsatisfactory appearance due to rust
through paint over time.
- Impaired function of interior door
hardware.
3 Physical and Chem Lab test - Report Detection Front Door - Ingress to and egress Corroded interior low door panels Deteriorated life of door leading to: Inappropriate wax formulation specified.
No. 1265. L.H from vehicle.-- Occupan... - Unsatisfactory appearance due to rust
through paint over time.
- Impaired function of interior door
hardware.
4 Design aid investigation with Detection Front Door - Ingress to and egress Corroded interior low door panels Deteriorated life of door leading to: Entrapped air prevents wax from entering
nonfunctioning spray head. L.H from vehicle.-- Occupan... - Unsatisfactory appearance due to rust corner/edge access.
through paint over time.
- Impaired function of interior door
hardware.
5 Laboratory test using "worst case" Detection Front Door - Ingress to and egress Corroded interior low door panels Deteriorated life of door leading to: Wax application plugs door drain holes
wax application and hole size. L.H from vehicle.-- Occupan... - Unsatisfactory appearance due to rust
through paint over time.
- Impaired function of interior door
hardware.
6 Drawing evaluation of spray head Detection Front Door - Ingress to and egress Corroded interior low door panels Deteriorated life of door leading to: Insufficient room between panels for spray
access. L.H from vehicle.-- Occupan... - Unsatisfactory appearance due to rust head access.
through paint over time.
- Impaired function of interior door
hardware.