Technical Specification: 40' X 8' X 9'6" ISO 1AAA TYPE Steel Dry Cargo Container
Technical Specification: 40' X 8' X 9'6" ISO 1AAA TYPE Steel Dry Cargo Container
TECHNICAL SPECIFICATION
FOR
ALL SPA-H
GOOSENECK TUNNEL
CORRUGATED ROOF
CORRUGATED DOOR
PLYWOOD FLOOR
2 VENTILATORS
FOR
GROUP STANDARD
Note:
1) This file is strictly confidential and privileged. It is intended only for the use of the intended recipient.
2) If you are not the intended recipient, any part of this file should not be copied, forwarded or used for any
purpose or disclosed to any person without the permission of factory.
1 of 14
40’x8’x9’6” GROUP STANDARD
SCOPE
This specification covers the design, construction, materials, testing, inspection and performance
requirements for ISO, 1AAA type steel dry cargo containers manufactured by factory.
The containers specified herein are manufactured under the quality control of FACTORY within the
perimeters as such set forth by the Classification Societies.
CONTENTS
1. GENERAL---------------------------------------------------------------------------------------3-4
5. MARKINGS------------------------------------------------------------------------------------11
7. WARRANTY-----------------------------------------------------------------------------------12
APPENDIX
Note:
1) This file is strictly confidential and privileged. It is intended only for the use of the intended recipient.
2) If you are not the intended recipient, any part of this file should not be copied, forwarded or used for any
purpose or disclosed to any person without the permission of factory.
2 of 14
40’x8’x9’6” GROUP STANDARD
1. GENERAL
The container is designed and manufactured for the carriage of general cargo by marine, road, and
rail. It is designed to maintain its structural and weathertight integrity within a temperature range of
-30 ºC to 80 ºC.
The container will conform to and satisfy the following regulations and standards.
1.2.1 ISO/TC-104
The container shall comply with the customs convention of containers, 1972 and all subsequent
revisions to date and will be identified with appropriate approval plates and markings.
All exposed timber components are treated with an Australian government approved insecticide and
the container will be such identified with appropriate immunization plate.
The container will be registered and comply with the International Union of Railways (UIC) code
592 OR.
The container will comply with the rules set forth in the International Convention for Safe
Containers and will be so identified with a plate.
The container will be certified by Classification Society in design and individually inspected during
its production.
1.3 Handling
The container will be constructed to be handled under the following conditions without distortion or
effect on its structural integrity:
1.4 Transportation
The container will be constructed to be suitable for transportation in normal operating conditions by
modes of:
2.1 Dimension
Title 40’HC
Length 12,192 (0, -10)
External (mm) Width 2,438 (0, -5)
Height 2,896 (0, -5)
Length 12,032 (0, -10)
Internal (mm) Width 2,352 (0, -5)
Height 2,698 (0, -5)
Door opening Width 2,340 (0, -5)
(mm) Height 2,585 (0, -5)
2.6.1 The faces of the bottom corner castings protrude from lowerfaces of all transverse members in the
base of the container by 17 MM (+0.5,-6.0 MM).
2.6.2 The upper faces of top corner castings protrude from upper faces of the highest point of the roof by 6
MM.
2.6.3 The outer side faces of corner castings protrude from outside faces of corner posts by 3 MM.
2.6.4 Under 1.8 x max. gross weight no part of the base will protrude more than 6 MM below the bottom
corner castings.
Note:
1) This file is strictly confidential and privileged. It is intended only for the use of the intended recipient.
2) If you are not the intended recipient, any part of this file should not be copied, forwarded or used for any
purpose or disclosed to any person without the permission of factory.
4 of 14
40’x8’x9’6” GROUP STANDARD
3.1 General
The container is mainly constructed with steel frames, corrugated panels welded by CO2 shielded
Arc welding. All welds of the exterior including the base frames are continuous with full penetration.
Wooden floor is fixed to the cross members by self-tapping screws. All crevices will be sealed with
elastic sealing compound.
3.2 Materials
The base structure will be composed of two (2) bottom side rails, a number of crossmembers and
one set of gooseneck tunnel and outriggers, which are welded together as a sub-assembly.
Each bottom side rail is built of a steel pressing made in one piece. The bottom flange face outwards
so as to be easily repaired and hard to corrode.
Qty. : 2 pcs
Shape : Double “Z” section
Dimension : 155 x 52 x 30 x 28 x 4.5mm
3.4.2 Crossmember
The crossmembers are composed of a number of small pressed channel section and some large one
located beneath each board joint of the plywood, which are placed at certain center distance. There
are 3 pcs of t4.0 stiffeners in each joint member.
The gooseneck tunnel consists of one piece pressed hat section tunnel plate, a number of pressed
channel section tunnel bows, one box (or welded box) section rear bolster and tunnel outriggers. The
gooseneck tunnel is designed according to ISO standard :
Note:
1) This file is strictly confidential and privileged. It is intended only for the use of the intended recipient.
2) If you are not the intended recipient, any part of this file should not be copied, forwarded or used for any
purpose or disclosed to any person without the permission of factory.
5 of 14
40’x8’x9’6” GROUP STANDARD
Note:
40’x8’x9’6” GROUP STANDARD
The rear frame consists of one door header, one door sill, four corner castings and two corner posts.
Each corner post is constructed from an inner part of channel shaped hot-rolled section steel and an
outer part of steel pressing, welded together to form a hollow section to ensure the door opening and
suitable strength against the stacking and racking force. Four (4) sets of hinge pin lugs are welded to
each outer part of the corner post.
The door header is constructed from a lower part of a "U" shaped steel pressing with internal
stiffener ribs at the location of the cam keeper’s backside and an upper part of steel pressing rear
header plate, they are welded together to form a box section to provide a high rigidity.
The door sill is built of a special channel section steel pressing with internal ribs as stiffeners at the
backside of each cam keeper. The upper face of the sill has a slope for better drainage and the
highest part is on the same level to the upper face of the wooden floor. Two channel section steel
recesses are provided adjacent to the bottom casting to prevent damage due to any twistlock
misalignment.
The side walls will be continuously welded to each other and to the side rails and corner posts.
Welding penetration side panels to rails should be min.75%.
Each top side rail is used a square steel pipe. Rail : 60 x 60 x 3.0 mm
Each side wall will be composed of a number of sheets for the intermediate (inner) parts and outer
panels at each end of side wall, fully vertically corrugated into trapezium section, butt welded
together to form one panel by automatic welding.
Trapezium − Depth : 36 mm
Outerface : 72 mm
Interface : 70 mm
Slope : 68 mm
Pitch : 278 mm
a) Inner panel : 1.6 mm thick, Qty. : 9 pcs / each side.
b) Outer panel : 2.0 mm thick, Qty. : 2 pcs / each side.
Note:
1) This file is strictly confidential and privileged. It is intended only for the use of the intended recipient.
2) If you are not the intended recipient, any part of this file should not be copied, forwarded or used for any
purpose or disclosed to any person without the permission of factory.
7 of 14
40’x8’x9’6” GROUP STANDARD
3.8 Roof
The roof will be constructed by several die-stamp corrugated steel sheets with a certain upwards
camber at the center of each trough and corrugation, these sheets are butt jointed together to form
one panel by automatic welding.
Four reinforcement plates shall be mounted around the four corner castings.
Each leaf consists of door panel, steel door frame which consists of vertical (inner & outer) and
horizontal (upper & lower) rails. They are welded together to form the rectangular door leave.
3.9.1.2 Door Frame : a) Door vertical rail : 100 x 50 x 3.2 mm (inner & outer)
b) Door horizontal rail : Channel section, 150 x 50 x 3.0 mm.
3.9.1.3 Each door is capable of swinging 270 degrees when fully opened and can be secured in that position
by means of door holder.
3.9.1.4 The right door is so designed that the right door must be opened before the left in compliance with
T.I.R. requirements.
The door gasket is of extruded EPDM with a double lip to ensure water tightness. The upper and
side gaskets are of 'J' type configuration. Bottom is of a 'C' type configuration. It is attached with
sealant and secured ABS retainers by stainless steel rivets(stainless rivet and steel shaft). The door
gasket middle upper corner is overlap to left door area with wider outer lip.
Note:
1) This file is strictly confidential and privileged. It is intended only for the use of the intended recipient.
2) If you are not the intended recipient, any part of this file should not be copied, forwarded or used for any
purpose or disclosed to any person without the permission of factory.
8 of 14
40’x8’x9’6” GROUP STANDARD
Four forged hinges, providing with bushed hole, are welded to each door leaf. Each door is installed
by hinge pins, washers and bushings.
Galvanized locking devices are secured to the door with nuts and bolts and has nylon bushings on
the brackets. The locking devices will be hot dip. Galvanized to 75 micron and will be installed after
the container is painted.
A door holder per door, made of mixed nylon rope, is tied to the center-side locking rod and the
receptacle (hook type) is welded to each bottom side rail to retain the door at the open position.
3.10 Floor
The floor consists of plywood. The plywood used will be certified to meet the requirements of
Australian Commonwealth Dept. of Health (Plant Quarantine Treatment Schedule) for Timber
Components ( T.C.T. ). The floor dimension should according to the IICL dimension standard. The
plywood thickness is 28 mm.
The plywood boards are longitudinally laid on the crossmember with a free floating flat steel at the
center. The plywood boards are tightly secured to each crossmember with countersunk self-tapping
electro-zinc plated steel screws. These heads of the floor screws are countersunk below the level of
the upper surface of the floor by 2.0 mm to 2.5 mm.
Screws : M8 x 45 x ø16(Head) mm
Screws’ Qty. : 5 pcs / end row and joint, 3 pcs / outrigger, 4 pcs / other.
3.10.3 The plywood used will be a minimum of 19 plies and will be:
Note:
1) This file is strictly confidential and privileged. It is intended only for the use of the intended recipient.
2) If you are not the intended recipient, any part of this file should not be copied, forwarded or used for any
purpose or disclosed to any person without the permission of factory.
9 of 14
40’x8’x9’6” GROUP STANDARD
3.11 Sealing
Note: The application of interior sealant will be put on after water testing.
3.12.1 Shoring Slots: 60x40 MM slots are provided for on each of the rear corner posts so that a 2" thick
batten can be secured to give protection against shifting cargo.
1) Lashing rings are welded to each bottom and top side rail at corresponding recessed area of side wall.
Lashing ring Qty. / each bottom or top side rail : 10 pcs , total : 40 pcs.
2) Lashing bars are welded on each front & rear corner post slot.
Lashing bars Qty. / each front & rear corner post : 2 pcs, total : 8 pcs.
3.12.3 Ventilators – Two (2) ventilators should be small type fabricated from A.B.S. resin by injection
molding process. They will be secured to the panel recess near right corner post of both side walls,
by means of three (3) Aluminum Huck bolts.
Customs seal provision are made on locking handle and retainer in accordance with TIR
requirements.
Note:
1) This file is strictly confidential and privileged. It is intended only for the use of the intended recipient.
2) If you are not the intended recipient, any part of this file should not be copied, forwarded or used for any
purpose or disclosed to any person without the permission of factory.
10 of 14
40’x8’x9’6” GROUP STANDARD
4. SURFACE PROTECTION
All steel components, prior to forming, will be shot-blasted to a SA 2.5 standard surface by means of
an automatic centrifugal shot surface cleaning machine. A weld-able primer compatible to the paint
system will be applied immediately to a thickness of 10 micron to preserve the surface integrity
during the assembly process. After the container is assembled it is shot-blasted again manually to
clean all the welds and any other area that was contaminated during the assembly process. Slags and
spatters are removed by means of grinding or needle hammers.
4.2 Paint
The zinc content of zinc rich primer shall be no less than 65% measured by weight of solid.
Exterior:
Apply one coat of zinc rich primer to 25 mic. DFT.
Apply one coat of epoxy primer to 40 mic. DFT.
Apply one coat of Acrylic top coat to 40 mic. DFT.
Total 105 mic. DFT.
4.3 Undercoating
The whole underside will be coated with 25 mic. of zinc rich primer and 200 mic. of Waxy or
Bituminous undercoating.
Total 225 mic. DFT.
5. MARKING
5.1 Lettering
The container will be marked in accordance with ISO requirements, owner's specifications, and other
regulatory authorities.
5.2 Materials
The decals are of a self adhesive type and are warranted for seven (7) years against normal wear and
Note:
1) This file is strictly confidential and privileged. It is intended only for the use of the intended recipient.
2) If you are not the intended recipient, any part of this file should not be copied, forwarded or used for any
purpose or disclosed to any person without the permission of factory.
11 of 14
40’x8’x9’6” GROUP STANDARD
All materials and parts are inspected by the manufacturer's Quality Control department to ensure
they are up to the specification called for in the design.
All containers are manufactured under effective quality control procedures to meet the specified
standards. All dimensions are checked and smooth operation of the doors are ensured after each
container's completion. A light and watertight test is conducted on all containers.
Quality control personnel independent of the production dept. will be inspecting on all phases of the
production as well as ad hoc inspections by the classification society's surveyor and buyer's
representatives to assure the quality of the container.
7. WARRANTY
7.1 Warranty
The warranty period will commence the day after the certification is issued by the classification
society.
The application of paint will be warranted against corrosion and paint failure for a period of five (5)
years. The warranty is for all faults affecting more than 10% of the painted surfaces and will assure
partial or total re-painting of the containers. Normal wear/tear, or corrosion caused by acid, alkali or
results of damages by abrasion, impact or accident are excluded.
Note: Corrosion is defined as rusting which exceeds RE3 (European scale of degree of rusting) on at
least ten (10) percent of the total container surface coated with the concerned coating system.
This container will be warranted against any defects or omissions in constructions, workmanship
and materials for a period of one (1) year. In the event of defects, FACTORY will replace, correct or
install to make the container satisfactory to this specification and its intended service at
FACTORY's expense. Any damages caused by mis-handling, mis-securing, mis-loading, impact and
any natures of accidents are excluded.
Note:
1) This file is strictly confidential and privileged. It is intended only for the use of the intended recipient.
2) If you are not the intended recipient, any part of this file should not be copied, forwarded or used for any
purpose or disclosed to any person without the permission of factory.
12 of 14
40’x8’x9’6” GROUP STANDARD
APPENDIX A
Note:
1) This file is strictly confidential and privileged. It is intended only for the use of the intended recipient.
2) If you are not the intended recipient, any part of this file should not be copied, forwarded or used for any
purpose or disclosed to any person without the permission of factory.
13 of 14
40’x8’x9’6” GROUP STANDARD
APPENDIX B
PROTOTYPE TESTING
The prototype container to be manufactured in accordance with this specification will be tested by
manufacturer under the supervision of classification society.
Note:
1) This file is strictly confidential and privileged. It is intended only for the use of the intended recipient.
2) If you are not the intended recipient, any part of this file should not be copied, forwarded or used for any
purpose or disclosed to any person without the permission of factory.
14 of 14