Table of Contents Encoder Omron
Table of Contents Encoder Omron
Absolute Encoders...................................................................................................................................... 3
Absolute Rotary Encoder E6C2-A .................................................................................... 3
First Page............................................................................................................. 3
Ordering Information ............................................................................................ 3
Specifications....................................................................................................... 4
Connections ......................................................................................................... 5
Operation ............................................................................................................. 5
Dimensions .......................................................................................................... 7
Installation............................................................................................................ 8
Contacting Omron................................................................................................12
Absolute Rotary Encoder E6CP........................................................................................13
Front Page ...........................................................................................................13
Ordering Information ............................................................................................13
Specifications.......................................................................................................14
Operation .............................................................................................................15
Dimensions ..........................................................................................................16
Contacting Omron................................................................................................18
Absolute Rotary Encoder E6F ..........................................................................................19
Front Page ...........................................................................................................19
Ordering Information ............................................................................................19
Specifications.......................................................................................................20
Operation .............................................................................................................20
Dimensions ..........................................................................................................21
Contacting Omron................................................................................................22
Incremental Encoders .................................................................................................................................23
Incremental Rotary Encoder E6A2 ...................................................................................23
Front Page ...........................................................................................................23
Ordering Information ............................................................................................23
Specifications.......................................................................................................24
Operation .............................................................................................................25
Dimensions ..........................................................................................................26
Contacting Omron................................................................................................26
Incremental Rotary Encoder E6B2 ...................................................................................27
Front Page ...........................................................................................................27
Ordering Information ............................................................................................27
Specifications.......................................................................................................28
Operation .............................................................................................................29
Dimensions ..........................................................................................................31
Installation............................................................................................................32
Contacting Omron................................................................................................32
Incremental Rotary Encoder E6C2-C ...............................................................................33
First Page.............................................................................................................33
Ordering Information ............................................................................................33
Specifications.......................................................................................................34
Operation .............................................................................................................35
Dimensions ..........................................................................................................37
Installation............................................................................................................39
Connection Examples ..........................................................................................39
Precautions ..........................................................................................................42
Contacting Omron................................................................................................44
Incremental Rotary Encoder E6D .....................................................................................45
Front Page ...........................................................................................................45
Ordering Information ............................................................................................45
Specifications.......................................................................................................46
Operation .............................................................................................................47
Dimensions ..........................................................................................................48
Contacting Omron................................................................................................48
Multi-turn Encoders.....................................................................................................................................49
Multiple-Rotation Absolute Encoder E6C-M .....................................................................49
First Page.............................................................................................................49
Ordering Information ............................................................................................49
Specifications.......................................................................................................50
Contacting Omron................................................................................................51
Absolute Rotary Encoder E6C-N ......................................................................................52
First Page.............................................................................................................52
Ordering Information ............................................................................................52
Specifications.......................................................................................................53
Operation .............................................................................................................54
Dimensions ..........................................................................................................57
Installation............................................................................................................59
Precautions ..........................................................................................................60
Contacting Omron................................................................................................60
R
Ordering Information
J ABSOLUTE ROTARY ENCODERS
Appearance Connection method Connecting device Resolution (p/r) Part number
Cable Programmable Controller 256, 360, 720, 1,024 E6C2-AG5C 256
E6C2-AG5C 360
E6C2-AG5C 720
E6C2-AG5C 1024
Connector H8PS Cam Positioner 256 E6C2-AG5C-C 256
Note: The H8PS can be connected to the E6C2-AG5C-C but not to the E6C2-AG5C.
2
E6C2-A E6C2-A
Specifications
J RATINGS/CHARACTERISTICS
Power supply voltage 12 VDC- 10% to 24 VDC+15%, ripple (p-p) 5% max.
Current consumption 70 mA max.
Resolution (See Note 1) 256, 360, 720, 1,024 P/R
Output code (absolute) Gray code
Output configuration NPN open collector
Output capacity Applied voltage 30 VDC max.
Isink 35 mA max.
Residual voltage 0.4 V max.
Max. response frequency (See Note 2) 20 kHz
Logic Negative logic output (H=0, L=1)
Rotational direction Clockwise, as viewed from the face of the shaft
Rise and fall times of output 1 µs max. (cable length: 2m; Isink : 35 mA max.)
Starting torque 100 gf S cm (0.087 in S lbf) max. at room temperature
150 gf S cm (0.13 in S lbf) max. at low temperature
Moment of inertia 15 g S cm2 (1.5 x 10- 6 kg S m2) or 0.005 lb S in2 max.
Shaft loading Radial 8 kgf (78.4N) or 17.6 lbf
Thrust 5 kgf (49N) or 11.0 lbf
Maximum permissible rotation 5,000 rpm
Ambient temperature Operating -- 10°C to 70°C (14°F to 158°F) with no icing
Storage -- 25°C to 85°C (-- 13°F to 185°F) with no icing
Ambient humidity Operating 35% to 85% (with no condensation)
Insulation resistance 20 MΩ min. (at 100 VDC) between carry parts and case
Dielectric strength 500 VAC, 50/60 Hz for 1 min between carry parts and case
Vibration resistance Destruction: 10 to 500 Hz, 1.0-mm single amplitude or 150 m/s2 (approx. 15G) for 11
min. 3 times each in X, Y, and Z axes
Shock resistance Destruction: 1,000 m/s2 (approx. 100G) 3 times each in X, Y, and Z axes
Degree of protection IEC IP64
Weight 300 g (0.66 lbs) with 2-m cable
Note: 1. A gray code signal with a remainder of 76 is used for a resolution of 360 per rotation and a gray code signal with a remainder of
152 is used for a resolution of 720 per rotation. Therefore, the code signal for a resolution of 360 per rotation uses addresses
76 through 435 and that for a resolution of 720 per rotation uses addresses 152 through 871.
2. The electrical maximum response rotation is determined by using the resolution and maximum response frequency in the fol-
lowing formula.
Maximum response frequency
Electrical maximum response rotation (rpm) = x 60
Resolution
Therefore, a signal cannot follow electrically if the actual rotation exceeds the maximum response rotation.
3
E6C2-A E6C2-A
Connections
J DURABLE DESIGN J SHAFT STRENGTH
The E6C2-A incorporates a high-performance LED, The E6C2-A has a stainless steel shaft that is 8 mm in diameter
custom-made diode array, high-density printed circuit board, and and approximately twice as strong as OMRON’s conventional
a compact, watertight, seal bearing that withstands heavy loads, Rotary Encoder shaft. The E6C2-A also has a reliable bearing
thus ensuring high mechanical durability, watertight performance, and metal slit plate, ensuring a shock resistance of 1,000 m/s2.
and compactness. The O-ring applied to the casing and a
watertight packing applied to the cable connector enhance the
watertight performance of the E6C2-A.
Thrust
Photodiode 5 kgf
Slit
O-ring LED
Casing Radial
8-dia. stainless steel shaft 8 kgf
Rotary disk
Watertight packing
Cable
Operation
J CONNECTIONS
Cable Specifications
Output signal
E6C2-AG5C
Wire color 8-bit (256) 9-bit (360) 10-bit (720, 1,024)
Light blue NC NC 29
Pink NC 28 28
Purple 25 25 25
Orange 21 21 21
Brown 20 20 20
White 27 27 27
Blue 24 24 24
Yellow 22 22 22
Green 23 23 23
Gray 26 26 26
--- Shield (GND)
Red 12 to 24 VDC
Black 0 V (Common)
4
E6C2-A E6C2-A
J OUTPUT MODE
Rotating direction: CW, as viewed from the face of the shaft.
Output transistor
Address
5
E6C2-A E6C2-A
Dimensions
Unit: mm (inch)
J E6C2-AG5C
58
(2.28)
Three, M4 holes
40±0.1 dia.
Depth: 5 (1.57)
8+0
- 0.018 dia.
(0.31+0-0.0007)
1
30+0
- 0.021dia.
(1.18+0 - 0.0008 )
50 dia.
(1.97)
14 max.
J E6C2-AG5C-C
30+0
- 0.021dia.
(1.18 + 0
- .00008)
58 (2.28)
8 +0
- 0.018 dia.
(0.31+0-0.0007)
1
30+0
- 0.021dia.
(1.18+0- 0.0008 )
50 dia.
(1.97)
14 max.
16.9 dia.
6
E6C2-A E6C2-A
Installation
J CONNECTING E6C2-AG5C-C TO H8PS CAM POSITIONER
Specifications
Rated voltage 24 VDC
Cam resolution 1.4° (a resolution of 256 per rotation)
Outputs Open-collector transistor output
NPN: H8PS-8B(F)
PNP: H8PS-8B(F)P
Cam outputs: 8 lines (Output No. 1 to 8)
30 VDC max., 100 mA max. (residual voltage: 2 V max.)
RUN OUT: Turns ON in Run and Test modes, OFF in Program mode in case of error
30 VDC max., 100 mA max. (residual voltage: 2 V max.)
TACHOMETER: 60-ppr signal output for rpm meter
30 VDC max., 30 mA max. (residual voltage: 0.5 V max. for NPN models, 2 V
max. for PNP models)
Encoder response 330 rpm
Functions Origin compensation (zero shift)
Rotating direction selection
Angle display selection
Teaching
7
E6C2-A E6C2-A
CQM1-CPU44-E
Workpiece
Input Specifications
Input voltage 24 VDC+10%/- 15%
Input impedance 5.4 kΩ
Input current 4 mA (TYP.)
ON voltage 16.8 VDC min.
OFF voltage 3.0 VDC max.
Counting speed 4 kHz max.
Input code Gray code (8, 10, or 12 bits)
(7.87)
(See note 3)
(196.85)
16.9 dia.
(See note 2)
8
E6C2-A E6C2-A
System Configuration Using a Resolution of 1,024 per Example of DM Setting for Comparison Table
Rotation
A combination of the CQM1-CPU4-4E and E6C2-AG5C ensures Lower limit 1
easy output angle setting for cam control in 360° or BCD mode. Upper limit 1 Bit AR 0500
Subroutine number 1
E6C2-AG5C Lower limit 2
Upper limit 2 Bit AR 0501
With a resolution of 1,024 per rotation Subroutine number 2
Not used.
E69-DC5 5M
Connection Upper limit 8
Cable Subroutine number 8
CQM1-CPU44-E
Two Encoder inputs can be controlled
independently.
Note: An upper or lower limit can be set with integers in BCD
mode and 5° increments in 360° mode. Subroutine num-
Mode Setting of CQM1-CPU44-E bers are set for interrupt processing.
Set port 1 to BCD mode and 10 bits
Bit
Port 1 comparison result AR 05
Port 2 comparison result AR 06
Comparison 1 result
1: Conformity
0: Nonconformity
Ladder Program Example Comparison 8 result
9
E6C2-A E6C2-A
00002 20003
E6C2-AG5C
20002
00002 20003
Converts a gray code
signal into a BIN code
00001 20002 signal (word 200).
20001
CPM1A-20CDR-j
00001 20002
00000 20001
20000
20302
01002
END (01)
Ladder Program
00009 Example of DM Setting for Comparison Table
20009
00008 20009 Lower limit 1
Bit 20300
20008 Upper limit 1
00008 20009 Lower limit 2
Bit 20301
Upper limit 2
00007 20008 Lower limit 3
Bit 20302
20007 Upper limit 3
Not used.
00006 20007 Converts a gray code
20006 signal into a BIN code Upper limit
signal (word 200). 16
00006 20007
00005 20006
20005
00005 20006
00004 20005
20004
00004 20005
10
E6C2-A E6C2-A
Red
(see note 1)
(see note 3)
Light blue
White
Gray
Purple
Binary code signals
Blue
Green
Yellow
Orange
Brown
Black
NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4.
R
OMRON ELECTRONICS LLC OMRON ON--LINE OMRON CANADA, INC.
One East Commerce Drive Global -- http://www.omron.com 885 Milner Avenue
Schaumburg, IL 60173 USA -- http://www.omron.com/oei Scarborough, Ontario M1B 5V8
1-800-55-OMRON Canada -- http://www.omron.com/oci 416-286-6465
Cat. No. CEDSAX4 11/01 Specifications subject to change without notice. Printed in U.S.A.
E6CP E6CP
Ordering Information
■ ENCODERS
The encoder with a "-C" in the part number has a cable that terminates in a connector for Omron’s H8PS Cam Positioner.
Resolution (pulses/revolution) Output code Output form Supply voltage Cable termination Part number
8-bit (256 pulses/revolution) Gray code Open collector 5 to 12 VDC Wire bundle E6CP-AG3C
12 to 24 VDC Connector E6CP-AG5C-C
■ ACCESSORIES
Description Part number
Shaft coupler; fits two 6 mm (0.24 in) dia. shafts E69-C06B
Extension cable, 5 m (16.40 ft) for E6CP-AG5C-C encoder E69-DF5
■ REPLACEMENT PARTS
Description Part number
Mounting brackets (set of 3) supplied with each E6CP encoder E69-FCA-02
2
E6CP E6CP
Specifications
Part number E6CP-AG3C E6CP-AG5C-C
Supply voltage 5 VDC -5% to 12 VDC +10%; 12 VDC -10% to 24 VDC +15%;
max. 5% ripple peak-to-peak max. 5% ripple peak-to-peak
Current consumption 90 mA max. 70 mA max.
Resolution (pulses/revolution) 8-bit (256 pulses/revolution)
Output code Gray code (binary)
Applicable Cam Positioner — H8PS
Output form Open collector output
Output capacity Applied voltage: 28 VDC
Residual voltage: 0.4 V max. at sink current
Sink current: 16 mA max.
Maximum response 5 kHz
frequency
Logic Negative (H level: 0, L level: 1)
Accuracy Within ±1°
Rotation direction Output code increases in clockwise direction when viewed from shaft
Output rise and fall times 1.0 µs max. with 16 V control output voltage, 1 kΩ load resistance and 2 m (6.56 ft) output cable
Starting torque 10 g-cm (0.14 oz-inch) max.
Shaft loading Radial 3 kgf (21.7 ft•lbs)
Axial 2 kgf (14.5 ft•lbs)
Moment of inertia 10 g-cm2 (0.055 oz-inch2) max.
Maximum rpm 1,000 rpm
Electrical connection Prewired with 2 m (6.56 ft) length cable Connector
Weight Approx. 200 g (7 oz)
Enclosure rating IEC: IP50
Ambient Operating -10°C to 55°C (14°F to 131°F)
temperature Storage -25°C to 80°C (-13°F to 176°F)
Ambient humidity 35% to 85% RH
Vibration resistance Mechanical durability: 10 to 55 Hz, 1.5 mm double amplitude, in X, Y, and Z directions for 2 hours each
Shock resistance Mechanical durability: approx. 100 G in X, Y, and Z directions, 3 times each
Insulation resistance 10 MΩ minimum at 500 VDC between current-carrying part and housing
Dielectric strength 500 VAC, 50/60 Hz for 1 minute between current-carrying part and housing
3
E6CP E6CP
Operation
■ OUTPUT CIRCUIT DIAGRAM
Wiring
■ TIMING CHART
Shaft rotation: Clockwise as viewed from the shaft
Output Mode
Revolution direction: CW (as viewed from shaft)
Output transistor
ON
20
OFF
ON
21
OFF
ON
22
OFF
ON
23
OFF
ON
24
OFF
ON
25
OFF
ON
26
OFF
27 ON
OFF
Address 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28
4
E6CP E6CP
Dimensions
Unit: mm (inch)
■ ENCODERS
E6CP-AG3C 10
5 50 (1.97)
8
3
45° 45°
1
56 25 50 (1.97)
(2.20) (0.98) dia.
dia. dia.
6 dia.
40 (1.57)
E6CP-AG5C-C 10
5 50 (1.97)
8
3
45° 45°
1
56 25 50 (1.97)
(2.20) (0.98) dia.
dia. dia. 6 dia.
40 (1.57) 37 (1.46)
Note:
* Oil-resistant, vinyl-insulated and shielded cable is 2 m
(6.56 ft) long. The E6CP-AG3C encoder terminates with a
6 mm OD wire bundle.
**E6CP-AG5C-C encoder terminates in a
connector that fits the H8PS Cam Positioner.
Panel
5.5 mm (0.22 dia.) hole 2
120°
18 16
(0.71) (0.63) 25
9 (0.35) (0.98)
dia.
120° 120°
8 3.1
Two C1 16
(0.63) 5.1
Three M5
5
E6CP E6CP
■ ACCESSORIES
Shaft Coupler E69-C06B
22 (0.87)
5.5 11 5.5
2.8
2.8 16.4 Four M3 set screws
Note:
6 (0.24) 15 (0.59) dia. 1. Material: Glass-filled polybutadiene terephthalate (PBT).
dia. 2. Each set screw must be tightened to 2.5 kg-cm (2.17 in-lbs.)
34.6 (1.36)
37 (1.46)
5,000
6
E6CP E6CP
Cat. No. CEDSAX4 11/01 Specifications subject to change without notice. Printed in the U.S.A.
E6F E6F
Ordering Information
■ ENCODERS
Encoders with a "-C" in the part number have a cable that terminates in a connector for Omron’s H8PS and H8PR Cam Positioners.
Resolution (pulses/revolution) Output code Output form Supply voltage Cable termination Part number
10-bit (360 pulses/revolution) BCD Open collector 5 to 12 VDC Wire bundle E6F-AB3C 360 2M
Connector E6F-AB3C-C 360 2M
8-bit (256 pulses/revolution) Gray code Open collector 12 to 24 VDC Connector E6F-AG5C-C
■ ACCESSORIES
Description Part number
Shaft coupler (supplied with E6F-AB3C 360 2M only) E69-C10B
Extension cable, 5 m (16.40 ft) for E6F-AB3C-C 360 2M and E6F-AG5C-C encoders E69-DF5
■ REPLACEMENT PARTS
Description Part number
Mounting brackets (set of 3) supplied with each E6F encoder E69-FCA-02
2
E6F E6F
Specifications
Part number E6F-AB3C 360 2M E6F-AB3C-C 360 2M E6F-AG5C-C
Supply voltage 5 VDC -5% to 12 VDC +10%; 12 VDC -10% to 24 VDC +15%;
max. 5% ripple peak-to-peak max. 5% ripple peak-to-peak
Current consumption 100 mA max. 70 mA max.
Resolution (pulses/revolution) 10-bit (360 pulses/revolution) 8-bit (256 pulses/revolution)
Output code BCD Gray code
Applicable Cam Positioner — H8PS H8PR
Output form Open collector output Open collector output
Output capacity Applied voltage: 30 VDC max. Applied voltage: 28 VDC
Residual voltage: 0.4 V max. at sink current Residual voltage: 0.4 V max. at sink current
Sink current: 35 mA max. Sink current: 16 mA max.
Maximum response 10 kHz 10 kHz
frequency
Logic Negative (H level: 0, L level: 1)
Accuracy ±0.5° max. ± 1°
Rotation direction Output code increased in clockwise direction when viewed from shaft
Output rise and fall times 1.0 µs max. with 5 V control output voltage, 470 Ω load resistance and 2 m (6.56 ft) output cable
2.0 µs max. with 5 V control output voltage, 1 kΩ load resistance and 2 m (6.56 ft) output cable
Starting torque 100 g-cm (1.39 oz-inch) max.
Shaft loading Radial 10 kgf (72.3 ft•lbs)
Axial 3 kgf (21.7 ft•lbs)
Moment of inertia 15 g-cm2 (0.082 oz-inch2) max.
Maximum rpm 5,000 rpm
Electrical connection Prewired with 2 m (6.56 ft.) length cable Connector
Weight Approx. 500 g (1.1 lb.)
Enclosure rating IEC: IP52F (dust-proof, drip-proof)
Ambient Operating -10°C to 70°C (14°F to 158°F)
temperature Storage -25°C to 80°C (-13°F to 176°F)
Ambient humidity 35% to 85% RH
Vibration resistance Mechanical durability: 10 to 55 Hz, 1.5 mm double amplitude, in X, Y, and Z directions for 2 hours each
Shock resistance Mechanical durability: approx. 100 G in X, Y, and Z directions, 3 times each
Insulation resistance 10 MΩ minimum at 500 VDC between current-carrying part and housing
Dielectric strength 500 VAC, 50/60 Hz for 1 minute between current-carrying part and housing
Operation
■ OUTPUT CIRCUIT DIAGRAM
Wiring
■ TIMING CHART
Shaft rotation: Clockwise as viewed from the shaft
Output Output
1° ± 0.5°
ON
ON 20
20 OFF
OFF
1 ON
ON 2
21 OFF
OFF
22 ON
22 ON
OFF
OFF
3 ON
ON 2
23 OFF
OFF
24 ON
20x10 ON OFF
OFF
ON
21x10 ON 25
OFF
OFF
6 ON
Address 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 2
OFF
ON
27
OFF
Address 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28
Dimensions
Unit: mm (inch)
■ ENCODERS 85 (3.35)
60 (2.36)
20 (0.79)
Four M3, depth 6 5
3
3
48 15
(1.89)
dia.
60 54 40
(2.36)(2.13)(1.57) 1
dia. dia. dia.
10 dia.
14 max.
6 dia.
*
2000
85 (3.35)
60 (2.36)
20 (0.79)
Four M3, depth 6 5
3
48 3
15
(1.89)
dia.
60 54 40
(2.36)(2.13)(1.57) 1
dia. dia. dia.
10 dia.
14 max.
16.9 (0.66) dia.
**
*
2000 37 (1.46)
Note:
* Oil-resistant, vinyl-insulated and shielded cable is 2 m (6.56 ft) long. The E6F-AB3C encoder terminates with a
6 mm OD wire bundle.
••E6F-AB3C-C and E6F-AG5C-C encoders terminate in a connector that fits H8PR and H8PS Cam Positioners.
4
E6F E6F
18 16 120°
(0.71) (0.63) 40
9 (0.35) (1.57)
120° 120° dia.
8 3.1
Two C1
16 (0.63)
5.1
Three M5
■ ACCESSORIES
Shaft Coupler E69-C10B
26.2 (1.03)
12
7.1 7.1
3.6
3.6 19 Four M4 set screws
10 (0.39) Note:
dia. 22 (0.87) dia.
1. Material: Glass-filled polybutadiene terephthalate (PBT).
2. A coupler is supplied with E6F-AB3C encoder.
3. Each set screw must be tightened to 2.5 kg-cm (2.17 in-lbs)
Cat. No. CEDSAX4 11/01 Specifications subject to change without notice. Printed in the U.S.A.
E6A2 E6A2
Ordering Information
■ ENCODERS
When ordering, add the resolution (pulses per revolution) between the part number and cable length.
For example, E6A2-CWZ3E 200 P/R 0.5M.
Resolution (pulses per revolution) Output phases Output form Supply voltage Part number
10, 60, 100, 200, 300, 360 A Voltage 5 to 12 VDC E6A2-CS3E ❑❑❑P/R 0.5M
Open collector 5 to 12 VDC E6A2-CS3C ❑❑❑P/R 0.5M
Open collector 12 to 24 VDC E6A2-CS5C ❑❑❑P/R 0.5M
100, 200 A, B Voltage 5 to 12 VDC E6A2-CW3E ❑❑❑P/R 0.5M
Open collector 5 to 12 VDC E6A2-CW3C ❑❑❑P/R 0.5M
Open collector 12 to 24 VDC E6A2-CW5C ❑❑❑P/R 0.5M
100, 200 A, B, Z (zero) Voltage 5 to 12 VDC E6A2-CWZ3E ❑❑❑P/R 0.5M
Open collector 5 to 12 VDC E6A2-CWZ3C ❑❑❑P/R 0.5M
■ REPLACEMENT PARTS
Description Part number
Shaft coupler (supplied with each encoder) E69-C04B
Mounting bracket (supplied with E6A2-CWZ encoders) E69-1
2
E6A2 E6A2
Specifications
Part number E6A2- E6A2- E6A2- E6A2- E6A2- E6A2- E6A2- E6A2-
CS3E CW3E CWZ3E CS3C CW3C CWZ3C CS5C CW5C
Supply voltage 5 VDC -5% to 12 VDC +10%; max. 5% ripple peak-to-peak 12 VDC -10% to 24 VDC
+15%; max. 5% ripple
Current consumption 30 mA max. 50 mA max. 20 mA max. 30 mA max. 20 mA max.
Resolution 10, 60, 100, 200 100, 200 10, 60, 100, 200 100, 200 10, 60, 100, 200
(pulses per revolution) 100, 200, 100, 200, 100, 200,
300, 360 300, 360 300, 360
Output phases A A, B A, B, Z A A, B A, B, Z A A, B
Output form Voltage output Open collector output Open collector output
Output capacity Output resistance: 2 kΩ Applied voltage: 30 VDC max. Applied voltage: 30 VDC
Residual voltage: 0.4 V max. Residual voltage: 0.4 V max. Residual voltage: 0.4 V
Sink current: 20 mA max. Sink current: 30 mA max. Sink current: 30 mA max.
Maximum response 30 kHz 20 kHz 20 kHz 30 kHz 20 kHz 20 kHz 30 kHz 20 kHz
frequency
Rotation direction Reversible, CW + CCW Reversible, CW + CCW Reversible, CW + CCW
Phase difference — 90° ±45° 90° ±45° — 90° ±45° 90° ±45° — 90° ±45°
of output
Output rise and fall times 1.0 µs max. (at sink current of 1.0 µs max. (at control output voltage of 5 V and
10 mA with 2 m cable) load resistance of 1 kΩ with 2 m cable)
Starting torque 10 g-cm (0.14 oz.-inch) max.
Shaft loading Radial 1 kgf (7.2 ft•lbs)
Axial 0.5 kgf (3.6 ft•lbs)
Moment of inertia 1 g-cm2 (0.0055 oz-inch2)
Maximum rpm 5,000 rpm
Electrical connection Prewired with 0.5 m (1.64 ft) length cable
Weight Approx. 35 g (1.2 oz)
Enclosure rating IEC: IP50
Ambient Operating -10°C to 55°C (14°F to 131°F)
temperature Storage -25°C to 80°C (-13°F to 176°F)
Ambient humidity 35% to 85% RH
Vibration resistance Mechanical durability: 10 to 55 Hz, 1.5 mm double amplitude, in X, Y, and Z directions for 2 hours each
Shock resistance Mechanical durability: 500 m/s2 (approx. 50 G) in X, Y, and Z directions, 3 times each
Insulation resistance 10 MΩ minimum at 500 VDC between current-carrying part and housing
Dielectric strength 500 VAC, 50/60 Hz for 1 minute between current-carrying part and housing
3
E6A2 E6A2
Operation
■ OUTPUT CIRCUIT DIAGRAMS
Voltage Output Wire Color Code
E6A2-CS3E, E6A2-CW3E E6A2-CWZ3E Note: IEC colors shown first.
Note:
Brown (Red) Brown (Red) 1. The white (green) and orange (yellow)
Vcc (+5 to 12 V) Vcc (+5 to 12 V) lines of the single type (E6A2-CS) do
or (+12 to 24 V) not output signals (no connection).
Black (White), White (Green)
Main Black (White), White (Green) Main Orange (Yellow) 2. The orange (yellow) line of the
circuit Output (A,B) circuit Output (A,B,Z)
30 VDC
reversible type (E6A2-CW) does not
30 VDC
30 mA max. 4Ω 30 mA max. output signal (no connection).
0V 0V 3. The voltage output type is capable of
Blue (Black) Blue (Black) sinking a maximum of 20 mA.
■ TIMING CHARTS
E6A2-CS E6A2-CW, E6A2-CWZ
Note:
1. *(H) and (L) indicate the output levels of the voltage output type.
2. Output A leads B by 1/4T ±1/8T when the shaft revolves clockwise. Output A lags
behind B by 1/4T ±1/8T when the shaft revolves counterclockwise.
4
E6A2 E6A2
Dimensions
Unit: mm (inch)
■ ENCODERS 8
1.5
1.5
Two M3, (0.32)
Depth: 4
6
22 12
(0.87)(0.47) 8 (0.31)
dia. dia.
3.6
18 (0.71) 10 2 29 (1.14)
(0.39) 5.5
25 (0.98) dia. 50 (1.97)
max.
21(0.83) Note:
5.2 10.6 5.2 1. Material: Glass-filled polybutadiene terephthalate (PBT).
2.7
2. A coupler is supplied with each E6A2 encoder.
2.7 15.6
3. Each set screw must be tightened to 2.5 kg-cm (2.17 in-lbs)
4 (0.16) 13 (0.51)
dia. dia.
Four M4 hex
socket head
set screws
120°
3.5 dia.
12 (0.47) +0.05
-0
4
1.6 +0
-0.05
Two
C0.5 8 2.8 32 (1.26)
dia.
Three M3
Cat. No. CEDSAX4 11/01 Specifications subject to change without notice. Printed in the U.S.A.
E6B2 E6B2
Ordering Information
■ ENCODERS
When ordering, add the resolution (pulses per revolution) between the part number and cable length.
For example, E6B2-CWZ3E 360 P/R 0.5M.
Resolution (pulses per revolution) Output phases Output form Supply voltage Part number
10, 20, 30, 40, 50, 60, 100, 200, 300, A, B, Z (reversible) Open collector 5 to 24 VDC E6B2-CWZ6C ❑❑❑P/R 0.5M
360, 400, 500, 600, 1000, 1200, A, B, Z (reversible) Voltage 5 to 12 VDC E6B2-CWZ3E ❑❑❑P/R 0.5M
1500, 1800, 2000 A, A, B, B, Z, Z Line driver 5 VDC E6B2-CWZ1X ❑❑❑P/R 0.5M
(reversible)
■ ACCESSORIES
Description Part number
Shaft coupler Fits one 6 mm (0.24 in) and 8 mm (0.32 in) dia. shaft E69-C68B
Fits one 6 mm (0.24 in) and 10 mm (0.39 in) dia. shaft E69-C610B
Mounting flange E69-FBA
Mounting bracket, set of three E69-FBA-02
■ REPLACEMENT PARTS
Description Part number
Shaft coupler Fits two 6 mm (0.24 in) dia. shafts; supplied with each encoder. E69-C06B
2
E6B2 E6B2
Specifications
Part number E6B2-CWZ3E E6B2-CWZ6C E6B2-CWZ1X
Supply voltage 5 VDC -5% to 12 VDC +10%; 12 VDC -10% to 24 VDC +15%; 5 VDC ±5%
max. 5% ripple peak-to-peak max. 5% ripple
Current consumption 100 mA max. 80 mA max. 160 mA max.
Resolution 10, 20, 30, 40, 50, 60, 100, 200, 300, 360, 400, 500, 600, 1000, 1200, 1500, 1800, 2000
(pulses per revolution)
Output phases A, B, Z (reversible) A, B, Z (reversible) A, A, B, B, Z, Z (reversible)
Output form Voltage output Open collector output Line driver output
Output capacity Output resistance: 2 kΩ Applied voltage: 30 VDC max. AM26LS31
Residual voltage: 0.4 V max. Residual voltage: 0.4 V max. Output current:
Sink current: 20 mA max. Sink current: 35 mA max. High level: -20 mA
Low level: +20 mA
Output voltage:
High voltage: 2.5 V minimum
Low voltage: 0.5 V maximum
Maximum response 100 kHz
frequency
Rotation direction Reversible, CW + CCW
Phase difference of output 90° ±45° between A and B (1/4T ±1/8T)
Output rise and fall times 1 µs max. with 1 µs max. with 0.1 µs max. with
cable length: 0.5 m (1.64 ft) control output voltage: 5 V cable length: 0.5 m (1.64 ft)
sink current: 10 mA max. load resistance: 1 kΩ output current high: -20 mA
cable length: 0.5 m (1.64 ft) output current low: +20 mA
Starting torque 10 g-cm (0.14 oz-inch) max.
Shaft loading Radial 3 kgf (21.7 ft•lbs)
Axial 2 kgf (14.5 ft•lbs)
Moment of inertia 10 g-cm2 (0.055 oz-inch2) max.; 3 g-cm2 (0.0165 oz-inch2) max. at 600 pulses/revolution
Maximum rpm 6,000 rpm
Electrical connection Prewired with 0.5 m (1.64 ft) length cable
Weight Approx. 100 g (3.5 oz) with cable
Enclosure rating IEC: IP50 (The E6B2 encoder is not watertight or oil resistant.)
Ambient Operating -10°C to 70°C (14°F to 158°F)
temperature Storage -25°C to 80°C (-13°F to 176°F)
Ambient humidity 35% to 85% RH
Vibration resistance Mechanical durability: 10 to 500 Hz, 15 G or 2-m double amplitude, in X, Y, and Z directions for
11 minutes, three times each
Shock resistance Mechanical durability: 1,000 m/s2 (approx. 100 G) in X, Y, and Z directions, 3 times each
Insulation resistance 1,000 MΩ minimum at 500 VDC between current-carrying part and housing
Dielectric strength 500 VAC, 50/60 Hz for 1 minute between current-carrying part and housing
Note:
The maximum electrical response revolution is determined by the resolution and maximum response frequency as follows:
Maximum electrical response frequency (rpm) = Maximum response frequency ÷ resolution x 60
This means that the E6B2 encoder will not operate electrically if its shaft speed exceeds the maximum electrical response revolution.
3
E6B2 E6B2
Operation
■ OUTPUT CIRCUIT DIAGRAMS
Open Collector Output
E6B2-CWZ6C
Wire Color Code
IEC colors are shown.
Brown 5 to 24 VDC (allowable range:
4.75 to 27.6 VDC)
Black, White, Color Terminal
Orange
Output signal Brown Power supply (+V)
E6B2 (Phases A, B, and Z)
NPN Black Output phase A
main
transistor
circuitry White Output phase B
35 mA max. Orange Output phase Z
3.3 Ω 30 VDC max.
Blue Blue 0 V (common)
0V
GND
Voltage Output
E6B2-CWZ3E
Wire Color Code
IEC colors are shown.
Brown 5 to 12 VDC (allowable range:
4.75 to 13.2 VDC) Color Terminal
2 kΩ Black, White, Brown Power supply (+V)
Orange
Output signal
(Phases A, B, and Z) Black Output phase A
E6B2
NPN
main
transistor
White Output phase B
circuitry
Orange Output phase Z
20 mA max.
3.3 Ω Blue 0 V (common)
Blue
0V
GND
Note:
Both open collector and voltage output models of E6B2 have a circuit to prevent damage
from a short-circuited load and reversed connection.
4
E6B2 E6B2
■ TIMING CHARTS
Open Collector Output E6B2-CWZ6C
Direction of rotation: CW Direction of rotation: CCW
Clockwise as viewed ➝ CW direction Counterclockwise as viewed ➝ CCW direction
from the shaft from the shaft
CW CCW
T (360°) T (360°)
ON ON
Phase A Phase A
OFF OFF
1/4T±1/8T (90°±45°)
ON ON
Phase B Phase B
OFF OFF
1/4T±1/8T (90°±45°)
ON ON
Phase Z Phase Z
OFF OFF
Note:
Note: Phase A is 1/4T ±1/8T slower than phase B.
Phase A is 1/4T ±1/8T faster than phase B. The ONs in the
above timing chart mean that the output transistor is ON and
the OFFs mean that the output transistor is OFF.
CW CCW
T (360°) T (360°)
H
Phase A H Phase A
L L
H H
Phase B Phase B
L L
1/4T±1/8T (90°±45°) 1/4T±1/8T (90°±45°)
Phase Z H Phase Z H
L L
Note: Phase A is 1/4T ±1/8T faster than phase B Note: Phase A is 1/4T ±1/8T slower than phase B.
CW CCW
T (360°) T (360°)
Phase A H Phase A H
L L
H H
Phase B Phase B
L L
1/4T±1/8T (90°±45°) 1/4T±1/8T (90°±45°)
Phase Z H Phase Z H
L L
Phase A H Phase A H
L L
H H
Phase B Phase B
L L
Phase Z H Phase Z H
L L
Note:
The line driver output circuit is an RS-422A data transmission circuit consisting of two balanced output lines. The relationship between
the two output lines is on an equal status. This means that if the level of the signal on a line is H, the level of the signal on the other line
is L. The noise-resistant line driver output circuit assures high-speed data transmission.
5
E6B2 E6B2
Dimensions
Unit: mm (inch)
15
■ ENCODERS Origin of phase Z Three, M3 holes x 7 (0.28) depth (0.59) 39
5
(1.54)
10
(0.39)
6 (0.24) dia.
120° 120° shaft
40 (1.57) 20 (0.79) 1
dia. dia.
■ ACCESSORIES
Shaft Coupler E69-C06B (included) Shaft Coupler E69-C68B for one 6 mm Shaft Coupler E69-C610B for one 6 mm
for two 6 mm diameter shafts and one 8 mm diameter shaft and one 10 mm diameter shaft
24.8
24.8 (0.98)
22 7.1 7.1
(0.98) Four, 4 mm hexagon
(0.87) 3.6
6.8 6.8 Four, 4 mm hexagon 3.6 socket head set
5.5 11 5.5 Four, 3 mm hexagon screws
socket head set 3.5 socket head set
2.8 3.5
screws screws
2.8 16.4
Note:
1. Material: Glass-filled polybutadiene terephthalate (PBT).
2. An E69-C06B coupler is supplied with each E6B2 encoder.
3. Each set screw must be tightened to 2.5 kg-cm (2.17 in-lbs)
42 (1.65)
Four R3
33 (1.30) Four 3.3 dia. holes
Three 3.5 dia. holes with
6.5 dia. screw-holes Dimensions with Encoder
20.2 (0.80)
dia. hole
Three, 3.5 dia. holes with
6.5 dia. countersink
33 (1.30)
The flange is 3.2 (0.13) thick.
30 (1.18) dia.
20.2 (0.80) dia.
46 (1.81) dia.
120°
Panel
20 (0.79)
dia.
18 16
(0.71)(0.63)
120°
6
E6B2 E6B2
Installation
■ INPUT TO MORE THAN ONE COUNTER FROM ENCODER WITH VOLTAGE OUTPUT
Use the following formula to obtain the number of counters to be connected to a single E6B2
+E
R1 (E-V)
Number of counters (N) =
V x R2 R2
+V
E: Voltage supplied to Rotary Encoder
V: Minimum input voltage of the counter 0V
R2: Output resistance of the Rotary Encoder
R1: Input resistance of the Rotary Encoder
Encoder output stage
R1 R1
Counter Counter
Connectable
number: N
Origin of phase Z
■ ORIGIN INDICATION
It is easy to adjust the position of phase Z with the origin Origin
indication function. The following illustration (on the left-hand 120° 120°
side) shows the relationship between phase Z and the origin. Cut face D
Set cut face D to the origin as shown in the illustration (on the
right-hand side).
30±0.2 dia.
Ordering Information
Supply voltage Output Resolution (P/R) Part number
configuration
5 to 24 VDC NPN open 10, 20, 30, 40, 50, 60, 100, 200, 300, 360, 400, 500, 600, E6C2-CWZ6C
collector output 1,000, 1,200, 1,500, 1,800, 2,000
5 to 12 VDC Voltage output E6C2-CWZ3E
5 VDC Line driver output E6C2-CWZ1X
12 to 24 VDC PNP open 100, 200, 360, 500, 600, 1,000, 2,000 E6C2-CWZ5B
collector output
Note: The power supply for the resolutions of 1,000, 1,200, 1,500, 1,800, and 2,000 is 12 to 24 VDC.
2
E6C2-C E6C2-C
Specifications
J RATINGS/CHARACTERISTICS
Electrical
Item E6C2-CWZ6C E6C2-CWZ3E E6C2-CWZ1X E6C2-CWZ5B
Power supply voltage 5 to 24 VDC (allowable 5 to 12 VDC (allowable 5 VDC±5% 12 VDC --10% to 24 VDC
range: 4.75 to 27.6 VDC) range: 4.75 to 13.2 VDC) +15%
Current consumption 80 mA max. 100 mA max. 160 mA max. 100 mA max.
(See Note 1.)
Resolution 10, 20, 30, 40, 50, 60, 100, 200, 300, 360, 400, 500, 600, 1,000, 1,200, 1,500, 100, 200, 360, 500, 600,
1,800, 2,000 P/R 1,000, 2,000 P/R
Output phases A, B, and Z (reversible) A, A, B, B, Z, Z A, B, and Z (reversible)
Output configuration NPN open collector Voltage output (NPN Line driver (See Note 2.) PNP open collector
output output) output
Output capacity Applied voltage: Output resistance: 2 kΩ AM26LS31 Isink: 35 mA max.
30 VDC max. (residual voltage: Output current: Residual voltage:
Isink: 35 mA max. 0.4 V max. High level (Io): --20 mA 0.4 V max.
Residual voltage: Isink: 20 mA max.) Low level (Is): 20 mA (Isink: 35 mA max.)
0.4 V max. Output voltage:
(Isink: 35 mA max.) Vo: 2.5 V min.
Vs: 0.5 V max.
Max. response 100 kHz 50 kHz
frequency
(See Note 3.)
Phase difference on 90°±45° between A and B (1/4T±1/8T)
output
Rise and fall times of 1 µs max. 1 µs max. 0.1 µs max. 1 µs max.
output (control output voltage: 5 V; (cable length: 2 m; (cable length: 2 m; (cable length: 2 m;
load resistance: 1 kΩ; Isink: 10 mA max.) Io: --20 mA; Isink: 10 mA max.)
cable length: 2 m) Is: 20 mA)
Insulation resistance 100 MΩ min. (at 500 VDC) between carry parts and case
Dielectric strength 500 VAC, 50/60 Hz for 1 min between carry parts and case
Note: 1. An inrush current of approx. 9 A flows for approx. 0.3 ms right after the E6C2-C is turned on.
2. The line driver output of the E6C2-C is used for data transmission circuitry conforming to RS-422A and ensures long-distance
transmission over twisted-pair cable, with quality equivalent to AM26LS31.
3. The maximum electrical response revolution is determined by the resolution and maximum response frequency as follows:
Maximum electrical response frequency (rpm) = maximum response frequency/resolution x 60
This means that the E6C2-C Rotary Encoder will not operate electrically if its revolution exceeds the maximum electrical
response revolution.
3
E6C2-C E6C2-C
J MECHANICAL
Item E6C2-CWZ6C E6C2-CWZ3E E6C2-CWZ1X E6C2-CWZ5B
Shaft loading
g Radial 5 kgf (49.0 N) 11.0 lbf
Thrust 3 kgf (29.4 N) 6.6 lbf
Moment of inertia 10 g S cm2 (1 x 10--6 kg S m2) max.; 3 g S cm2 (3 x 10--7 kg S m2) max. at 600 P/R
max. 6.6 x 103lb/in .85 x 10
Starting torque 100 gf S cm (9.8 mN S m) max. (7.2 m ft S lbf)
Max. permissible revolution 6,000 rpm
Vibration resistance 10 to 500 Hz, 150 m/s2 (15G) or 2-mm double amplitude for 11 min 3 times each in
X, Y, and Z directions
Shock resistance 1,000 m/s2 (100G) 3 times each in X, Y, and Z directions
Weight Approx. 400 g max. (cable length: 2 m) 0.88 lbs
J ENVIRONMENTAL
Item E6C2-CWZ6C E6C2-CWZ3E E6C2-CWZ1X E6C2-CWZ5B
Ambient temperature
p Operating --10°C to 70°C (14_F to 158_F) with no icing
Storage --25°C to 85°C (--13_F to 185_F) with no icing
Ambient humidity Operating 35% to 85% (with no condensation)
Protective circuit Protection from load short-circuiting and power supply reverse polarity wiring
Degree of protection IEC IP64 (JEM IP64f drip-proof) (See Note.)
Note: The applicable JEM standard is JEM1030 1991.
Operation
J OUTPUT CIRCUIT DIAGRAM
E6C2-CWZ6C E6C2-CWZ3E
Brown
5 to 24 VDC (permissible Brown
range: 4.75 to 27.6 VDC) 5 to 12 VDC (permissible
range: 4.75 to 13.2 VDC)
Black, white, orange 2 kΩ
Output signal Black, white, orange
E6C2-C NPN (Black: Phase A; Output signal
main White: Phase B; E6C2-C (Black: Phase A;
transistor NPN
circuitry Orange: Phase Z) main White: Phase B;
transistor
35 mA max. circuitry Orange: Phase Z)
3.3 Ω
30 VDC max. Blue 3.3 Ω 20 mA max.
0V Blue
Ground 0V
(Shielded) Ground
(Shielded)
E6C2-CWZ1X E6C2-CWZ5B
Brown Brown
5 VDC±5%
Black, white, orange 3.3 Ω
Non-reversed output
(Black: Phase A; White:
E6C2-C Phase B; Orange: Phase Z)
AM26LS31 or Black, white, orange E6C2-C
main Reversed output (Black/ 35 mA max.
equivalent (with red stripes) main
circuitry Red: Phase A; White/Red: circuitry
Phase B; Orange/Red: Black, white, orange
Blue Phase Z Output signal
(Black: Phase A; White:
0V
Phase B; Orange: Phase Z)
Ground
(Shielded) 0V
PNP transistor Blue
Ground
(Shielded)
4
E6C2-C E6C2-C
J TIMING CHARTS
NPN Open Collector Output
E6C2-CWZ6C
PNP Open Collector Output
E6C2-CWZ5B
Direction or resolution: Clockwise (CW) Direction or resolution: Counterclockwise (CCW)
(As viewed from the end of the shaft) (As viewed from the end of the shaft)
T (360°) CW
T (360°) CCW
ON
Phase A
OFF ON
Phase A
ON OFF
Phase B 1/4T±1/8T (90°±45°)
OFF ON
1/4T±1/8T (90°±45°) Phase B
ON OFF
Phase Z
OFF ON
Phase Z
OFF
Note: Phase A is 1/4±1/8T faster than phase B. The Note: Phase A is 1/4±1/8T slower than phase B
ONs in the above timing chart mean that the
output transistor is ON and the OFFs mean
that the output transistor is OFF.
Voltage Output
E6C2-CWZ3E
Direction or resolution: Clockwise (CW) Direction or resolution: Counterclockwise (CCW)
(As viewed from the end of the shaft) (As viewed from the end of the shaft)
H H
Phase A Phase A
L L
1/4T±1/8T (90°±45°)
H H
Phase B Phase B
L L
1/4T±1/8T (90°±45°)
H H
Phase Z Phase Z
L L
Note: Phase A is 1/4±1/8T faster than phase B. Note: Phase A is 1/4±1/8T slower than phase B.
5
E6C2-C E6C2-C
J ORIGIN INDICATION
It is easy to adjust the position of phase Z with the origin indication function. The illustration below on the left side shows the relationship be-
tween phase Z and the origin. Set cut face D to the origin as shown in the illustration on the right.
Origin of phase Z
Origin
D cut
38 dia.
J INPUT TO MORE THAN ONE COUNTER FROM ENCODER (WITH VOLTAGE OUTPUT)
Use the following formula to obtain the number of counters to be connected to a single E6C2-C Rotary Encoder.
R1 (E--V)
Number of counters (N) = +E
V x R2
R2
E: Voltage supplied to Rotary Encoder +V
V: Minimum input voltage of the counter
R2: Output resistance of the Rotary Encoder
R1: Input resistance of the Rotary Encoder 0V
R1 R1
Encoder output stage
Counter Counter
Connectable
number: N
Dimensions
Unit: mm (inch)
J E6C2-C
60
(2.36)
Origin of phase Z 15 5 40 6.59
Three, M4 holes 1.6 10 (1.57) (0.26)
Depth: 7 mm
0
6 --0.021 dia.
(0.24 +0
--.0008
)
1
50 dia.
(1.97)
0
25 --0.021 dia.
(0.98+0 --0.0008
)
38 dia.
(See Note.)
6
E6C2-C E6C2-C
Note: The coupling is made of Note: The coupling is made of Note: Material: Super duralumin
glass-reinforced PBT. glass-reinforced PBT.
Flanges
E69-FCA E69-FCA-02 Mounting bracket:
(A set of three b333rackets provided with th
52 x 52
(2.05 x 2.05) E69-FCA-02)
2
43±0.15 Four, 4.5-dia. holes
Four, R3 (1.69 +0
--0.006 ) Three, 4.5-dia. holes with 5.5-dia. hole
8.5-dia. screw-head holes (0.22)
± 0.05
25.2 0 -dia. hole 18
16
(0.99 +0.002 ) 9
--0
Three, 5.5
43±0.15 52 The flange is made of screw-head
SPCC, t = 3.2 holes Two, C1
8.5 dia. 8 3.1 +0.1
0
38 dia. 16
25.2±0.1 dia. 5.1
(0.63)
56 dia.
(2.20)
(0.99±0.004)
Mounting Dimensions
Panel
25 dia.
(0.98)
5.5-dia. hole
(0.22)
18
16
9
Two, C1
8 +0.1
3.1 0
16
(0.63) 5.1
Installation
J CONNECTION
E6C2-CWZ6C/-CWZ3E
Color Terminal
Brown Power supply (+VCC)
Black Output phase A
White Output phase B
Orange Output phase Z
Blue 0 V (common)
Color Terminal
Brown Power supply (+VCC)
Black Output phase A
White Output phase B
Orange Output phase Z
Blue/Red stripes Output phase A
White/Red stripes Output phase B
Orange/Red stripes Output phase Z
Blue 0 V (common)
Note: 1. The shield is not connected to the internal circuits or casing of the E6C2-C.
2. There is no difference in circuit among phases A, B, and Z.
3. Connect the GND terminal to 0 V or the ground when the E6C2-C is in normal operation.
Connection Examples
J H7ER SELF-POWERED TACHOMETER J H7BR DIGITAL COUNTER
Applicable Model: E6C2-CWZ3E (with a resolution of 10 Applicable Model: E6C2-CWZ3E
or 60 P/R)
E6C2--CWZ3E E6C2-C
Brown Brown
H7ER Digital Tachometer Black
Black White
Shielded
Blue Blue
5 to 12 VDC 0V +12 V
8
E6C2-C E6C2-C
Black
White
Blue
0V E6C2-CWZ6C
Blue (0 V)
Shielded
J C500-CT001/CT012 HIGH-SPEED
COUNTER UNIT
CW and CCW detection (increment/decrement counting)
Applicable Model: E6C2-CWZ6C
E6C2-C
Brown
Black
Blue
White
Shielded
9
E6C2-C E6C2-C
Phase Z
+12 V Phase Z Phase Z
Phase A Phase B
Phase A
Phase B Phase B
0V
Phase B
Phase A
Phase B Phase A Phase A
10
E6C2-C E6C2-C
Precautions
Refer to the following illustrations when using a standard coupling.
J AVOID DAMAGE OR MALFUNCTION
Decentering
• Do not impose voltage exceeding the rated voltage range on tolerance
the E6C2-C.
• Be sure that the wiring of power supply to the E6C2-C is 0.15 mm max.
correct. (0.006)
• Turn off the Rotary Encoder when wiring.
• Do not wire power lines or high-tension lines along with the
power supply lines of the E6C2-C Rotary Encoder. Declination
tolerance
J MOUNTING
• Be careful not to spray water or oil onto the E6C2-C Rotary 2° max.
Encoder.
• The E6C2-C Rotary Encoder consists of high-precision
components. To avoid malfunction, handle with extreme care Displacement
and do not drop the Rotary Encoder. tolerance in the
• Do not pull the cable of the E6C2-C Rotary Encoder after the shaft direction 0.05 mm max.
E6C2-C Rotary Encoder is mounted to a panel. Do not apply (0.002)
any shock to the hollow shaft or the body.
• When the E6C2-C Rotary Encoder is used in reversed When connecting or disconnecting the coupling, do not impose an
operation, pay utmost attention to the mounting direction of excessive bending, pressing, or pulling force on the E6C2-C.
the E6C2-C Rotary Encoder and the directions of increment
and decrement rotation. When connecting the shaft of the Rotary Encoder with a chain tim-
ing belt or gear, connect the chain timing belt or gear with the shaft
• To match phase Z of the E6C2-C Rotary Encoder and the via the bearing and coupling as shown in the following illustration.
origin of the device to be connected to the E6C2-C Rotary
Encoder, the phase Z outputs must conform while connecting Chain sprocket
Bearing E6C2-C
the device.
Coupling
• Be careful not to impose an excessive load on the shaft if the
shaft connects to a gear.
• If the Rotary Encoder is mounted with screws, the tightening
torque must be approximately 5 kgf S cm (0.49 N S m)
0.36 ft lbf.
• If the Rotary Encoder is mounted to a panel, do not pull the
cable with more than a force of 3 kgf (29.4 N) 6.61 lbf. If the decentering or declination value exceeds the tolerance, an ex-
cessive load imposed on the shaft may damage the Rotary Encoder
E6C2-C or shorten the life of the Rotary Encoder.
Bearing Life
The following graph shows the life expectancy of the bearing with
Cable radial and thrust loads imposed on the bearing. (Theoretical)
3 kgf (29.4 N) max.
Mounting plate
Encoder
Shaft
Wr: Radial load
Ws: Thrust load
11
E6C2-C E6C2-C
Mounting Procedure • The rise time varies with the resistance of the cable and the
1. Insert the shaft into the coupling. type and length of the cable.
Do not secure the coupling and shaft with screws at this • The residual output voltage will increase according to the
stage. length of the cable.
2. Secure the Rotary Encoder.
Refer to the following table for the maximum insertion length
of the shaft into the coupling.
OL(V)
( µ s)
Part number Maximum insertion length
LH
E69-C06M 8.5 mm (0.33)
12
E6C2-C E6C2-C
NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4.
R
OMRON ELECTRONICS LLC OMRON ON--LINE OMRON CANADA, INC.
One East Commerce Drive Global -- http://www.omron.com 885 Milner Avenue
Schaumburg, IL 60173 USA -- http://www.omron.com/oei Scarborough, Ontario M1B 5V8
1-800-55-OMRON Canada -- http://www.omron.com/oci 416-286-6465
Cat. No. CEDSAX4 11/01 Specifications subject to change without notice. Printed in U.S.A.
E6D E6D
Ordering Information
■ ENCODERS
When ordering, add the resolution (pulses per revolution) after the part number. For example, E6D-CWZ1E 1500P/R.
Resolution (pulses per revolution) Output phases Output form Supply voltage Part number
720, 800, 1000, 1024, 1200, 1500, 1800, 2000, A, B (reversible), Voltage 5 VDC E6D-CWZ1E ❑❑❑
2048, 2500, 3000, 3200, 3600, 4096, 5000, 6000 and Z (zero) Open collector 12 VDC E6D-CWZ2C ❑❑❑
■ REPLACEMENT PARTS
Description Part number
Shaft coupler (supplied with each encoder) E69-C06B
Mounting bracket (supplied with E6D-CWZ encoders) E69-FCA-02
2
E6D E6D
Specifications
Part number E6D-CWZ1E E6D-CWZ2C
Supply voltage 5 VDC ±5%; max. 5% ripple peak-to-peak 12 VDC ±10%; max. 5% ripple
Current consumption 150 mA max.
Resolution 720, 800, 1000, 1024, 1200, 1500, 1800, 2000, 2048, 2500, 3000, 3200, 3600, 4096, 5000, 6000
(pulses per revolution)
Output phases A, B, Z
Output form Voltage output Open collector output
Output capacity Output resistance: 1 kΩ Applied voltage: 30 VDC max.
Residual voltage: 0.7 V max. at 10 mA Residual voltage: 1 V max. at 35 mA sink current
sink current 0.7 V max. at 10 mA sink current
Sink current: 35 mA max. Sink current: 35 mA max.
Maximum response 200 kHz
frequency
Rotation direction Reversible, CW + CCW
Phase difference of output 90° ±25° between A and B (1/4T ±0.07T)
Output rise and fall times 1 µs max.
Starting torque 100 g-cm (1.39 oz-inch) max.
Shaft loading Radial 5 kgf (36.2 ft•lbs) max.; 2 kgf (14.5 ft•lbs) at rated accuracy
Axial 3 kgf (21.7 ft•lbs) max.; 1 kgf (7.2 ft•lbs) at rated accuracy
Moment of inertia 30 g-cm2 (0.165 oz-inch2)
Maximum rpm 12,000 rpm
Electrical connection Prewired with 0.5 m (1.64 ft) length cable
Weight Approx. 280 g (9.9 oz)
Enclosure rating IEC: IP50
Ambient Operating -10°C to 70°C (14°F to 158°F)
temperature Storage -25°C to 80°C (-13°F to 176°F)
Ambient humidity 35% to 85% RH
Vibration resistance Mechanical durability: 10 to 55 Hz, 1.5 mm double amplitude, in X, Y, and Z directions for 2 hours each
Shock resistance Mechanical durability: 500 m/s2 (approx. 50 G) in X, Y, and Z directions, 3 times each
Insulation resistance 10 MΩ minimum at 500 VDC between current-carrying part and housing
Dielectric strength 500 VAC, 50/60 Hz for 1 minute between current-carrying part and housing
3
E6D E6D
Operation
■ OUTPUT CIRCUIT DIAGRAMS
Voltage Output Wire Color Code
E6D-CWZ1E Note: IEC colors shown first.
Brown (Red)
Wire color Signal
0V Brown (Red) VCC
1Ω Black (White): output A Black (White) A
Main Outputs White (Green): output B
Circuit
Orange (Yellow): output Z White (Green) B
TTL 30 Ω
7407 Blue (Black) Orange (Yellow) Z
5V
Blue (Black) 0 V (common)
Shield
GND
Brown (Red)
12 V
Shield
GND
■ TIMING CHARTS
Voltage Output Type
E6D-CWZ1E
360° 360°
T t1, t2, t3, t4 = 90° ± 25° T t1, t2, t3, t4 = 90° ± 25°
(1/4T ± 0.07T) t1 t2 t3 t4 (1/4T ± 0.07T)
t1 t2 t3 t4
H H
Output A Output A
L L
H H
Output B Output B
L L
Output Z H Output Z H
L L
360° 360°
T t1, t2, t3, t4 = 90° ± 25° T t1, t2, t3, t4 = 90° ± 25°
(1/4T ± 0.07T) (1/4T ± 0.07T)
t1 t2 t3 t4 t1 t2 t3 t4
ON ON
Output A Output A
OFF OFF
ON ON
Output B Output B
OFF OFF
Output Z ON Output Z ON
OFF OFF
4
E6D E6D
Dimensions
Unit: mm (inch)
■ ENCODERS
Three
M3 x 0.5
holes; "D" shaft groove
0.5 6 depth
6 (0.24) dia.
shaft
5.5 OD
55 50 shielded
(2.17)(1.97) cable, 0.5 m
dia. dia. (1.64 ft)
length
120°
120°
42
(1.65) 3
dia. 9 1.5 3 9
50 (1.97)
16.5
(0.65)
5.5 mm
(0.22 dia.) Panel
hole 2
18
16
(0.71) 120°
(0.63)
9 (0.35)
50 (1.97)
120° 120° dia.
8 3.1
Two C1
16
(0.63) 5.1
Cat. No. CEDSAX4 11/01 Specifications subject to change without notice. Printed in the U.S.A.
R
Ordering Information
Name Part Number
Multiple-rotation Absolute Encoder E6C-MPZ1X2 (see note)
Receiver Unit E63-SR5C
Note: Order the Encoder and Receiver Unit as a set.
2
E6C-M E6C-M
Specifications
J RATINGS/CHARACTERISTICS
Part number E6C-MPZ1X2 E63-SR5C
Power supply voltage --- 12 VDC- 10% to 24 VDC+15%
Current consumption 150 mA max. (see note 1) 150 mA max.
Resolution Absolute 2,048/rotation (11 bits) ---
4,096 rotations (12 bits)
Incremental 2048/rotation ---
Output code (absolute) --- Pure binary
Output phases (incremental) --- A, B, and Z
Phase difference on output (incremental) --- 90°±45° (1/4T±1/8T) between A and B
Output configuration --- NPN open collector
Output capacity --- Applied voltage: 30 VDC max.
Isink : 20 mA max.
Residual voltage: 0.4 V max. (Isink : 20
mA)
Max. response frequency 150 kHz (incremental signal) ---
Max. rotational frequency response 4,500 rpm (1,000 rpm from 1 s after a ---
power interruption) (see note 2)
Condenser backup time 20 hrs (typical) ---
Battery backup time --- 5 years min.
Internal ER17/33 lithium battery
(1500 mAH Hitachi Maxell battery)
Rotational direction Output code incremented by clockwise ---
rotation
Starting torque 100 gf S cm (9.8 mN S m) max. ---
Moment of inertia 15 g S cm2 (15 x 10- 7 kg S m2) max. ---
Shaft loading Radial 5 kgf (49 N) ---
Thrust 3 kgf (29.4 N) ---
Ambient temperature Operating -- 10°C to 70°C (14°F to 158°F) with no -- 10°C to 55°C (14°F to 131°F) with no
icing icing
Storage -- 25°C to 70°C (-- 13°F to 158°F) with no -- 25°C to 65°C (-- 13°F to 149°F) with no
icing icing
Ambient humidity Operating 35% to 85% (with no condensation)
Insulation resistance 20 MΩ min. (at 100 VDC) between carry parts and case
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between carry parts and case
Vibration resistance Destruction 10 to 500 Hz, 1-mm single amplitude (150 10 to 150 Hz, 0.75-mm single amplitude
m/s2 (approx. 15G) for 11 min 3 times (100 m/s2 (approx. 10G) for 8 min 4 times
each in X, Y, and Z directions each in X, Y, and Z directions
Shock resistance Destruction 1,000 m/s2 (approx. 100G) 3 times each in 300 m/s2 (approx. 30G) 3 times each in X,
X, Y, and Z directions Y, and Z directions
Enclosure ratings IEC IP64 watertight (JEC IP64F oil resistive) ---
Weight 350 g (cable: 2 m, with connector) 350 g
Note: 1. When the Encoder’s internal condenser is completely discharged, there will be an inrush current of 300 mA max. for about 2 s.
Also, the battery alarm might go ON if the condenser is discharged; in this case, reset the Encoder with the ERS (Encoder
Reset Input) before operation.
2. If the main power supply is interrupted, the Encoder’s internal condenser and Receiver Unit’s internal battery will supply power to
retain rotational frequency data and continue rotational measurement. The Encoder can continue to respond to 4,500 rpm rotation
for 1 second after the main power is interrupted, butthereafter the maximum rotational frequency response drops to 1,000 rpm.This
feature allows the Encoder to keep up with the rotational speed of devices which continue to rotate due to inertia after a power
interruption.
For more information on this product line, see the complete data sheet at
Omron’s Knowledge Center on our web site: www.omron.com/oei
3
E6C-M E6C-M
NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4.
R
OMRON ELECTRONICS LLC OMRON ON--LINE OMRON CANADA, INC.
One East Commerce Drive Global -- http://www.omron.com 885 Milner Avenue
Schaumburg, IL 60173 USA -- http://www.omron.com/oei Scarborough, Ontario M1B 5V8
1-800-55-OMRON Canada -- http://www.omron.com/oci 416-286-6465
Cat. No. CEDSAX4 11/01 Specifications subject to change without notice. Printed in U.S.A.
R
Ordering Information
J ABSOLUTE ROTARY ENCODERS
Item Part number
Shaft model with cable E6C-NN5C
Hollow-shaft model with cable E6C-NN5CA
Shaft model with connector E6C-NN5C-C
Hollow-shaft model with connector E6C-NN5CA-C
Specifications
J RATINGS/CHARACTERISTICS
Power supply voltage 12 VDC- 10% to 24 VDC+10%, ripple (p-p): 5% max. (see note 1)
Current consumption 80 mA max.
Resolution Single-rotation 500 P/R
absolute
Multi-rotation -- 128 to 127 rotations (see note 6)
absolute
Rotational limitation at power failure ±80° (see note 2)
Output Output code Binary code
Alarm output Counter Overflow Output (see note 3)
Output NPN open-collector output
configuration
Output capacity Applied voltage: 30 VDC max.
Isink: 10 mA max. (with 30-mA Counter Overflow Output)
Residual voltage: 0.4 V max.
Logic Negative logic output
Rotational Clockwise, as viewed from the face of the shaft.
direction
Input Input signal Single-rotation data reset and multi-rotation data reset (see note 4)
Input current 1 mA max.
Input logic L active, normally open
Input time 100 ms max.
Max. response frequency 12.5 kHz
Rise and fall times of output 1 µs max.
Starting torque 30 gf S cm (2.94 mN S m) (2.17 m ft S lbf) max.
Moment of inertia 1.5 x 10- 6 kg S m2 (15 g S cm2) (0.21 lb/in2) max.
Shaft loading Radial 3 kgf (29.4N) (6.6 lbf)
Thrust 2 kgf (19.6N) (4.4 lbf)
Max. permissible rotation 1,500 rpm
Ambient temperature Operating -- 10°C to 55°C (14_F to 131_F) with no icing (see note 5)
Storage -- 25°C to 65°C (-- 13_F to 149_F)
Ambient humidity 35% to 85% with no condensation
Insulation resistance 20 MΩ min. (at 100 VDC) between carry parts and case
Dielectric strength 500 VAC, 50/60 Hz for 1 min between carry parts and case
Vibration resistance Destruction: 10 to 500 Hz, 1.0-mm single amplitude or 150 m/s2 (15G) for 11 min, 3 times
each in X, Y, and Z directions
Shock resistance Destruction: 1,000 m/s2 (100G) 3 times each in X, Y, and Z directions
Enclosure rating IEC IP50
Housing material Mechanism PPS resin
Case ABS resin
Weight 400 g max. (with 2-m cable)
Note: 1. When the power supply is turned off, all data output is turned off and no data can be input.
2. At the time of power failure, no multi-rotation detection is performed, and multi-rotation data is compensated by comparing the
data values immediately before and after the power fails. The accuracy of multi-rotation data will be affected if the power fails
and there is a rotation exceeding ±80° of the position at the time of power failure. Be sure that the rotation is within the specified
range.
3. Counter Overflow Output will turn ON if the multi-rotation counter exceeds a range between -- 128 and 127 rotations. This error
flag will be reset if the count returns to a value within the above range.
4. If single- and multi-rotation data reset signals are input, single-rotation data will be reset to address 0 and independently, multi-
rotation data will be reset to rotation 0.
5. Be sure that the equipment connected to the Encoder shaft is within the rated operating range.
2
E6C-N E6C-N
6. Multi-rotation absolute negative values are expressed with 2’s complements. Refer to the list of codes provided.
Multi-rotation Absolute Value Codes
Note that by replacing values 1 and 0 of a positive value with each other and adding 1, a negative value is expressed.
Operation
J CONNECTION
E6C-NN5Cj - Cable Specifications
Cable color: Gray Cable color: Black
Lead wire color Signal name Description Lead wire color Signal name Description
Brown ABS0 Single-rotation 20 Brown TKN0 Multi-rotation 20
absolute data absolute data
Orange ABS1 21 Orange TKN1 21
Yellow ABS2 22 Yellow TKN2 22
Green ABS3 23 Green TKN3 23
Blue ABS4 24 Blue TKN4 24
Purple ABS5 25 Purple TKN5 25
Gray ABS6 26 Gray TKN6 26
White ABS7 27 White TKN7 27
Pink ABS8 28 Pink C0F Counter overflow alarm
Light blue ARST Single-rotation data reset Light blue TRST Multi-rotation data reset
Black GND 0 V (see note) Black GND 0 V (see note)
Red VCC 12 to 24 VDC (see note) Red VCC 12 to 24 VDC (see note)
--- SHIELD Shield --- SHIELD Shield
Note: It is recommended that both VCC lines and GND lines be connected.
3
E6C-N E6C-N
Note: It is recommended that both VCC lines and GND lines be connected.
Terminal Arrangement
12 to 24 VDC
Output
Main
circuit
Main
Reset input
circuit TRST Shield
ARST
4
E6C-N E6C-N
J OUTPUT MODE
Rotational Direction: Clockwise, as viewed from the face of the shaft.
Output transistor
Address
5
E6C-N E6C-N
Dimensions
Unit: mm (inch)
J E6C-NN5C (WITH CABLE)
E6C-NN5C-C (WITH CONNECTOR)
65
(2.56)
Three, M4 holes 45 (1.77)
Depth: 8
6 dia.
(0.24)
25 dia,
(0.98)
50 dia.
38 dia.
(1.97)
(1.50)
6 external dia. PVC, shielded
12-conductor cable (7/0.18 dia.)
2,000
(78.74)
E6C-NN5C-C
29 (1.14)
50 dia
(1.97)
14 dia. 8 dia.
(0.55) (0.31)
Two, M3
2,000
(78.74)
Center of shaft
6
E6C-N E6C-N
Unit: mm (inch)
Flanges
25.2 dia.
38 dia.
(1.50)
56 dia.
Note: Material is SPCC, t = 3.2
Note: Material is SPCC, t=3.2
Mounting Dimensions
Panel
25 dia.
68 dia.
(2.68) Three, M5
18 9
(0.71) (0.35)
Two, C1
(0.63)
7
E6C-N E6C-N
Installation
J CONNECTION EXAMPLE
Connection with CPM1A
Ladder Program Example
E6C-NN5C
(Always ON)
25313
ANDW(34)
Transfers only the data of
000 bits 0 through 8 of word 000
CPM1A-40CDj-j #01FF to DM 0000 (single-rotation
BIN data).
D0000
BCD(24)
Converts single-rotation BIN
D0000
data into a BCD code signal.
Wiring between E6C-NN5C and CPM1A D0001
D0007
Output Timing D0010
(>) 000
E6C-NN5C’s absolute data Compares the
25505
1 rotation 2 rotations 127 rotations band and output
10000 bit 01000 is ON if
linear absolute
(=)
25506 data exists be-
tween the value of
DM 0010 and
DM Setting DM 0011 and that
of DM 0012 and
CMPL(60)
DM 0013. The
DM 0000
band is compared
0001 D0007 in the forward
0002 0000 rotational direction
D0012
only.
0003
000
0004 (<)
Data program work area
25507
0005
10001
0006
0007 (=)
Linear absolute data 25506
0008
0009 Comparison data
10000 10001
0010 9000
Upper-limit setting 01000
0011 0000
0012 0500
Lower-limit setting
0013 0001
8
E6C-N E6C-N
Precautions
J MOUNTING The E6C-N consists of high-precision components. Handle the
E6C-N with care:
To Avoid Damage or Malfunction
• Keep E6C-N free of water or oil drops.
• Do not use the E6C-N at a voltage exceeding the rated volt-
• Do not short-circuit the load, or the E6C-N may be damaged.
age range.
• If the E6C-N is mounted with a cable wired, do not pull the
• Be sure to wire the lines of the E6C-N separately from power
cable with a force exceeding 3 kgf (29.4 N).
lines-tension lines in a separate, shielded conduit.
• The torque required to tighten each screw must be 5 kgf S cm
• Do not make mistakes in wiring, such as mistakes in polarity.
(0.49 N S m) maximum. Excessive tightening torque may
• Be sure that the E6C-N is turned off when wiring, or the out- damage the E6C-N.
put circuit may be damaged if an active output line comes in
• Do not impose excessive loads on the shaft, or the shaft may
contact with the power line.
be damaged.
• Do not directly connect the shaft to chains, timing belts, or
J CORRECT USE gears. Be sure to connect the shaft through appropriate bear-
ings and couplings.
• If the power supply has surge voltage, connect a surge ab-
sorber in parallel to the power supply to absorb the surge • If there is a difference in angle between the shaft and the
voltage. other shaft connected, an excessive load that may damage
the shaft will be imposed on the shaft. Be sure that the shaft
• To protect the E6C-N from noise interference, be sure that
is connected properly.
each wire connected to the E6C-N is as short as possible.
• When inserting the shaft to a coupling, do not strike the shaft
• The E6C-N may output a pulse signal when the E6C-N is
or coupling with a hammer or impose any other shock to the
turned on or off. Turn on each device connected to the
shaft or coupling.
E6C-N one second after turning on the E6C-N and turn each
• When connecting or disconnecting the coupling to or from the
device off one second before turning off the E6C-N.
shaft, do not excessively bend, press, or pull the coupling.
NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4.
R
OMRON ELECTRONICS LLC OMRON ON--LINE OMRON CANADA, INC.
One East Commerce Drive Global -- http://www.omron.com 885 Milner Avenue
Schaumburg, IL 60173 USA -- http://www.omron.com/oei Scarborough, Ontario M1B 5V8
1-800-55-OMRON Canada -- http://www.omron.com/oci 416-286-6465
Cat. No. CEDSAX4 11/01 Specifications subject to change without notice. Printed in U.S.A.