Project: Dog Legged Stair Design Constant: OK Under Reinforced
Project: Dog Legged Stair Design Constant: OK Under Reinforced
Riser, R= 150 mm
Span, l= 4.9 m
3.3
175
Depth, D= mm
Height H= 3600 mm
1.6
Main Reinforcement
Factored BM , Mu = 1.5 x 26.09 = 39.14 kN m
2
k= M u
/bd = (39.14x10^6)/(1000x154^2) = 1.65
Ast = (0.5 fck/fy)x[1-sqrt{1-(4.6k/fck)}]x bd = 637.153 mm2 / m width
Required, # 12 @ 177 mm c/c
Provide, # 12 @ 125 mm c/c OK
Actual pt = (1000 A? / s b d) x 100 = 0.59 %
pt,lim = 0.414 x(fck/fy)x(Xu,max/d)x100 = 0.95 %
Since, pt < pt,lim Hence design is OK
Distribution Reinforcement
Providing nominal reinforcement of 0.12 %
Asd = (0.12/100)x ### x 1000 = 210 mm2 /m length
Required, # 8 @ 239.238 mm c/c
Provide, # 8 @ 150 mm c/c OK
Since all the bars of tensile reinforcement are taken into the support the anchorage and
development length requirements will be automatically satisfied.