Project: Dog Legged Stair Design Constant: OK Under Reinforced

The document provides design details for a dog legged stair, including: - The stair has a effective span of 4.9m, thread of 300mm, riser of 150mm, and depth of 175mm. - The total load per meter width is calculated to be 10.865 kN/m. - The required bending moment is 26.09 kN m and shear force is 26.62 kN. - The main reinforcement is designed as #12 bars at 125mm c/c, providing 908.6mm^2 per meter width. - The distribution reinforcement is #8 bars at 150mm c/c, providing 210mm^2 per meter length. -
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
83 views

Project: Dog Legged Stair Design Constant: OK Under Reinforced

The document provides design details for a dog legged stair, including: - The stair has a effective span of 4.9m, thread of 300mm, riser of 150mm, and depth of 175mm. - The total load per meter width is calculated to be 10.865 kN/m. - The required bending moment is 26.09 kN m and shear force is 26.62 kN. - The main reinforcement is designed as #12 bars at 125mm c/c, providing 908.6mm^2 per meter width. - The distribution reinforcement is #8 bars at 150mm c/c, providing 210mm^2 per meter length. -
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 4

PROJECT: ANM(KHAGARIA) Drg. No.

Dog Legged Stair Sl. No.


Design Constant Material M 25
Xu,max/d = 700/(1100 + 0.87 fy ) = 0.46 Fe 500
Ru = 0.36*(X u,max
/d)*(1 - 0.416 X u,max
/d)*fck = 3.35
Effective Length and Depth
Effective span = 4.9 m
Keep, D = 175 mm Available, d = 175 - 21 = 154 mm

1.6 Thread, T = 300 mm

Riser, R= 150 mm
Span, l= 4.9 m
3.3

175
Depth, D= mm
Height H= 3600 mm
1.6

Load Calculation for 1 m width of slab


wt. of slab on slope, w' = (175/1000)x1x25 = 4.375 kN/m
wt. of slab on hor. Area, w1= w' x sqrt(R2+T2)/T = 4.89 kN/m
wt. of steps, w2 = (150/2000) x 1 x 25 = 1.875 kN/m
wt. of finishing, w3 = 0.1 kN/m
live load, w4 = 4 x 1 = 4 kN/m
Total load, w = w1 + w2 + w3 + w4 = 10.865 kN/m

Bending Moment and Shear Force


BM in span, M = wl2/10 = 26.09 kN m
SF at support, V = wl/2 = 26.62 kN
Required, d = sqrt(M u
/R u
b) = 108.084 mm Available, d= 154 mm OK
The section is under reinforced

Main Reinforcement
Factored BM , Mu = 1.5 x 26.09 = 39.14 kN m
2
k= M u
/bd = (39.14x10^6)/(1000x154^2) = 1.65
Ast = (0.5 fck/fy)x[1-sqrt{1-(4.6k/fck)}]x bd = 637.153 mm2 / m width
Required, # 12 @ 177 mm c/c
Provide, # 12 @ 125 mm c/c OK
Actual pt = (1000 A? / s b d) x 100 = 0.59 %
pt,lim = 0.414 x(fck/fy)x(Xu,max/d)x100 = 0.95 %
Since, pt < pt,lim Hence design is OK

Distribution Reinforcement
Providing nominal reinforcement of 0.12 %
Asd = (0.12/100)x ### x 1000 = 210 mm2 /m length
Required, # 8 @ 239.238 mm c/c
Provide, # 8 @ 150 mm c/c OK

Since all the bars of tensile reinforcement are taken into the support the anchorage and
development length requirements will be automatically satisfied.

Check for Shear


Factored SF, Vu = 1.5 x 26.62 = 39.93 kN
Nominal Shear Stress, ? v = Vu
/bd = 0.26 N/mm2
Shear strength of section,?c = 0.52 N/mm3 for pt = 0.59 %
Since, ? v < ? c The section is SAFE

Check for Deflection


Effective span = 4.9 m
For simply supported slab L/d = 20 from limit state of serviciability
fs 0.58 fy Ref. to fig. 4 of
= Ast (req.) = 203
IS456
Ast (prov.)
Modification factor = 1.6
Hence, required, d = L/(20*1.6) = 153 mm
Available, d = 154 mm OK
Effective cover = 21 mm
?c = [0.85x sqrt(0.8 fck ) x {sqrt(1.0+5?) - 1}]/ 6? ? = (0.8 fck)/(6.89 pt)
= 0.52 N/mm2 = 4.92

Ast (req.) = 637.153 mm2 Ast (prov.) = 908.6 mm2