0% found this document useful (0 votes)
301 views24 pages

Emergency Range: Providing Safety When You Need It The Most

Emergency lighting provides safety during power outages and requires specialized products. Thorn offers a range of dedicated emergency luminaires for various applications that comply with AS/NZS 2293 standards for design, installation, and maintenance of emergency lighting systems. These standards specify lighting levels, duration, and activation times for emergency situations. Thorn sales representatives can help select suitable products and advise consulting authorities to ensure code and regulatory compliance.

Uploaded by

gilbertomjc
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
301 views24 pages

Emergency Range: Providing Safety When You Need It The Most

Emergency lighting provides safety during power outages and requires specialized products. Thorn offers a range of dedicated emergency luminaires for various applications that comply with AS/NZS 2293 standards for design, installation, and maintenance of emergency lighting systems. These standards specify lighting levels, duration, and activation times for emergency situations. Thorn sales representatives can help select suitable products and advise consulting authorities to ensure code and regulatory compliance.

Uploaded by

gilbertomjc
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 24

Emergency Range

Providing safety when you need it the most


Emergency Range

Voyager LED Disk Danube


9 16

Voyager LED Exit ImpactForce II


10 17

LED Emergency CorrosionForce II


Module 18
11

Cadet WeatherForce
12 19

MaxiBatten Voyager Dali


13 Central Monitoring
20

College
14

SusTain II
15

www.thornlighting.com.au 3
Lighting people and places
Emergency Lighting

A well designed emergency Each Emergency Lighting


application tends to have its own
Thorn Sales representatives
are always available to help

lighting installation is potentially unique requirements. Thorn can


offer a specialist service to help
with interpreting the various
requirements in AS/NZS 2293.

lifesaving, and requires


select the most suitable products
We also recommend, when
from the wide range available.
designing any emergency
specialist products. Once it has been determined
that an Emergency Lighting
scheme, that the National
Construction Code (NCC) and
system is required, AS/NZS Local Authorities are consulted at
Thorn offers a range of 2293 sets out the standards
for design, installation and
the earliest possible stage.
Emergency Luminaires are not
dedicated, well designed maintenance of that system.
Broadly speaking, the criteria
only needed to comply to
AS/NZS 2293 when it comes to
luminaires for use in a variety of covered in this Standard deals
with:
their construction, they must also
undergo the following three tests
applications. 1. H
 ow much light there should
before the luminaire becomes
compliant:
be in those areas in which

A wide range of integrated it is mandatory to have


Emergency Lighting.
•E
 MC (Electromagnetic
Compatibility)

emergency versions of standard 2. H


 ow long the light should
remain ON for in an
• T hermal testing (charge up
and down)
luminaires are also available. emergency.
•P
 hotometric testing (for
3. H
 ow fast the Emergency Emergency Classifications)
Lighting should come on after
the mains system has failed.
4. Maintenance requirements.

4 Contents www.thornlighting.com.au
Lighting people and places
PEC-
Performance, Efficiency and Comfort

PEC – Performance, Efficiency PEC reconciles the need for


minimal direct and environmental
Performance:
Providing the best visual

and Comfort – is the dynamic, costs combined with the need


to deliver workplace and public
effectiveness. Thorn emergency
luminaires provide emergency

results-orientated programme
lighting that promotes efficiency, lighting and signage that
safety, a healthy environment clearly comply with the legal
and productivity. With statutory requirements laid out in AS/NZS
that underpins the Thorn pressures increasing, PEC offers 2293.1.
Thorn customers the ability
approach to lighting design and to provide optimum lighting
solutions while conserving Efficiency:
implementation. energy, finances and raw
materials.
Conserving energy and effort,
reducing CO2 emissions and
waste. Our emergency products
Emergency Lighting evokes PEC emphasises Thorn’s
balanced approach to create
are carefully engineered to
consume the least possible
the spirit of Thorn’s PEC application specific and
environmentally sensible lighting
power and to provide a long-life
solution. In addition, Thorn offers
programme.
solutions that address the
LEDs, High Frequency Ballast,
unique needs of the user. The
Addressable Test and SelfTest
programme is based on the
fittings that deliver valuable cost
principle that a correct balance
savings.
of Performance, Efficiency and
Comfort produces an effective
lighting solution with minimal
Comfort:
impact on the people using
Giving people satisfaction
it, its impact on the natural
and stimulation. Inclusion of
environment and optimal effect
emergency versions of standard
on the people using it. It takes
luminaires ensures a ‘clutter-
into consideration that every
free’ architectural scheme.
project is unique and requires a
Thorn offers a stylish range of
different balance between these
dedicated emergency fittings
three components.
includes lighting and exit
signage to suit all applications.

www.thornlighting.com.au Contents 5
Lighting people and places
Emergency Lighting
Standards

Emergency lighting legislation lays down specific requirements


for the design and performance of Thorn’s Emergency range. The
range is designed to comply with these regulations.
Duration of operation Discharge Test Spacing of Emergency (b) Spacing between luminaires
Initial - At the time of Facilities must be provided for Luminaires and walls - The spacing
commissioning, all emergency conducting a discharge test on The maximum spacings between between emergency
luminaires/exit signs must all emergency luminaires and adjacent emergency luminaires luminaires and any adjacent
operate satisfactorily on exit signs without disconnecting and between emergency escape wall or other boundary
emergency power for 120 mains power from normal luminaires and adjacent walls defining the limits of the
minutes. lighting. This feature can be or other surfaces forming the designated area must be no
either manually operated or boundary of the designated area greater than half the spacing
In-service - At any time during
automatically operated. must not exceed the relevant determined in accordance
the life of an installation, the
values determined as follows: with Item (a).
duration of operation of every
emergency luminaire or exit sign
Acceptable Emergency
must be no less than 90 minutes
Luminaires (a) S
 pacing between Marking of Emergency
(except where applicable
An internally illuminated exit sign luminaires - The horizontal Luminaires
building regulations specify a
may be used to perform the dual spacing between adjacent Each emergency luminaire
shorter minimum period).
roles of illuminated emergency luminaires must not exceed must have its illumination
exit signage and emergency the maximum spacing. classification, in accordance with
luminaire, provided that it For the spacings of Thorn’s AS/NZS 2293, marked on the
Test switch
meets all requirements for both Emergency luminaires/exit body of the luminaire.
A switch must be provided to
purposes specified in signs refer to pages 22 and
permit the operation of each Where emergency luminaire
AS/NZS 2293. 23.
emergency luminaire or exit sign does not bear the identification
to be checked by simulating a Where adjacent luminaires symbol specified below,
supply circuit failure. have different classifications, the symbol must be applied
Specific locations requiring the spacing must not exceed immediately adjacent to the
Emergency Luminaires the sum of half the maximum fitting. However it must not be
An emergency luminaire must permissible spacings for placed on removable ceiling
Visual indicator
be sited within 2 metres of the respective luminaires, tiles.
Visual indication of battery
the approach side of each determined in accordance
charger operation must be
doorway. An exit sign must be with the above.
provided. The indicator must be
located where it is necessary
either red or green in colour and Where the luminaire has
to emphasise the position of
must be visible after luminaire/ a different classification
potential hazards within the
exit sign has been mounted. in the transverse (C0) and
designated area.
longitudinal (C90) planes, the Required Location
orientation of the luminaires Exit signs complying with
must be taken into account in AS/NZS 2293.3 must be
determining the appropriate installed in the locations
spacing. determined as necessary in
accordance with The National
Where adjacent luminaires Construction Code (NCC).
are installed -
(i) other than parallel; or
(ii) a
 t an angle of other
than 90°;

C180 C0

C90

6
Lighting people and places
Contents www.thornlighting.com.au
Changes in Emergency
Lighting Standards

Thorn is a proud member of


Lighting Council Australia.
The Emergency Lighting Working It is recommended that the Size of Pictorial Elements Maintenance
Group, an expert group of pictogram signs be used for The minimum height of the For sites where repair or
Lighting Council Australia, new buildings or refurbishments pictorial element for all maintenance is required and
provides the following advice where an entire building or illuminated exit signage is pre-existing EXIT signage is
on recent changes to emergency floor’s exit signs are being 100mm, with no limit on the installed, either the EXIT or
lighting requirements in changed. This is to represent the maximum height. There are four pictogram sign may be used.
Australia. latest and best practice which recommended pictorial element Other arrangements may be
is relevant when considering heights: 100, 150, 200 and considered on a project by
The emergency lighting
OH&S and civil liability issues. 250mm. These correspond to a project basis, with approval of
standards that have been
However if only a limited maximum viewing distance. the applicable local authority.
published are; AS 2293.1:2005
number of signs are being
Part 1 System Design, Installation Maximum Viewing Distance Definitions -
changed, it may be prudent to
and Operation, replacing
use existing EXIT signage as it Element Height
Maximum
AS/NZS 2293.1:1998 and Viewing Distance •M
 aintained
is recommended that to avoid
AS 2293.3:2005 Part 3 (mm) (metres) - Luminiarie in which all
confusion, pictogram and EXIT
Emergency Escape Luminaires ≥ 100 <150 16m emergency lighting lamps are
signage not be integrated down
and Exit Signs, replacing AS/ ≥ 150 <200 24m energised at all times when
the same egress paths.
NZS 2293.1:1995. ≥ 200 <250 32m
normal or emergency lighting
Two of these categories are ≥ 250 40m
The principal reason for these is required.
addressed in the new AS2293
recent editions is to specify •N
 on-Maintained
standard Emergency escape The maximum viewing distance
requirements for exit signs - Luminaire in which all
lighting and illuminated must be marked in the green
employing the internationally emergency lighting lamps are
emergency exit signs. background of each diffuser.
accepted pictograms, instead of in operation only when the
the previously used word EXIT. It can be within one of the
supply to the normal lighting
elements or on any additional
Significant changes from the Pictograms fails.
background.
previous editions include: The new standards allow only
•S
 ustained
the following pictograms: The Australian Building Codes
•R
 eplacement of word EXIT with - Luminaire containing two
Board (ABCB) publishes the
a pictogram. or more lamps, at least
National Construction Code
one of which is energised
• Inclusion of detailed restrictions (NCC) previously known as the
on use of arrows. from the emergency lighting
Building Code of Australia (BCA)
supply and the other
each year. The ABCB recognises
•R
 evision of viewing distances from the normal lighting
these emergency lighting
for Exit Signs. supply. The emergency
standards. These standards must
•A
 doption of terminology from Straight On From Here lamp(s) in a combined
apply to projects with building
AS/NZS 60598.2.22. emergency luminaire is (are)
approval after May 2006.
either maintained or non-
• T his standard is not a joint maintained.
Australia/New Zealand
document; there is no content Note: All twin lamp
specific to New Zealand. fluorescent luminaires listed
are Sustained Maintained
• T he way thermals are
Emergency.
measured. Left From Here

Right From Here


These are from the international
standard ISO3864-1.

www.thornlighting.com.au Contents Lighting people and places


7
LED
Voyager LED Disk
LED
LED 3W output with 1W consumption
3W output
AS/NZS60598
AS/NZS 60598 AS/NZS
AS/NZS2293
2293

Class
Class II Electrical
Electrical
IP20

Discreet, high performance, LED


emergency luminaire

• Limited maintenance required


• D40 classification
• Discreet, good looking, and
compact profile
• Efficient LED technology, gives
excellent performance and
spacing

Depth of Range
Emergency Duration: 2 hours.
LED: 3W output with less than
1W consumption.
Battery: limited maintenance
battery.
Recharge Period: 16 hours.
Charging Monitor: LED.
Two cut-out dimensions.
Available with DALI for central
monitoring.
29 33 Materials/Finish
85
Polycarbonate white cover with
145 diecast aluminium body.
Installation/Mounting
Ceiling recessed installation with
two different cut-out dimension
options, 70mm and 110mm (for
ease of installation and service
where ceiling access is limited),
provided with flex & plug.
Specification
To specify state:
Ordering Guide 3W LED Emergency Disk with
Description Wt (kg) SAP Code C0 C90 C180
D40 classification.
VOYAGER (A) LED DISK 3W EL2 0.9 96066756 D40 D40 D40
As Thorn Voyager LED Disk.
VOYAGER (A) LED DISK 3W EL2X 0.9 96066761 D40 D40 D40
EL2 - Emergency LED Standard, EL2X- Emergency LED DALI

www.thornlighting.com.au Contents Lighting people and places


9
LED
Voyager LED Exit
LED 2W output with < 2W consumption
AS/NZS60598 AS/NZS 2293
Class I Electrical
IP20

Versatile emergency luminaire


with outstanding performance

• Long-life advantages of LEDs


• Attractive slim aesthetics
• Limited maintenance required
• DALI version for central test

Depth of Range
Emergency Duration: 2 hours.
LED: 2W output with less than
2W consumption.
Battery: limited maintenance
battery.
Recharge Period: 16 hours.
White and silver finishing.
Charging Monitor: LED.
Installation: ceiling, wall.
Label indication: all pictograms
provided.
Available with DALI for central
357 38 monitoring.
Distance dimension: for 24m.
Materials/Finish
321 Powder coated finish in white
or silver.
Installation/Mounting
Suitable for surface mounting
on wall or ceiling with quick
fix bracket. Bracket for wall
mounting installation and a
Ordering Guide complete set of labels are
Description Wt (kg) SAP Code C0 C90 C180 included.
VOYAGER (A) LED BLD EXIT 2W EL2 WH 1.6 96066757 C12.5 C12.5 C12.5
VOYAGER (A) LED BLD EXIT 2W EL2 SI 1.6 96066758 C12.5 C12.5 C12.5 Specification
VOYAGER (A) LED BLD EXIT 2W EL2X WH 1.6 96066762 C12.5 C12.5 C12.5 To specify state:
VOYAGER (A) LED BLD EXIT 2W EL2X SI 1.6 96066763 C12.5 C12.5 C12.5 2W LED blade Emergency Exit.
VOYAGER (A) LED PICTOGRAM SET 0.1 96537031 C12.5 C12.5 C12.5 As Thorn Voyager LED Exit.
Set of pictogram already included in the box.
EL2 - Emergency LED Standard, EL2X- Emergency LED DALI, WH - White

10
Lighting people and places
Contents www.thornlighting.com.au
LED
LED Emergency Module


Class
LED
LED 3W output with 1W consumption
AS/NZS60598
AS/NZS 60598
Class II Electrical
Electrical
3W output
AS/NZS
AS/NZS2293
2293

IP20

The demand for a single • Naturally improves the


interior design whilst reducing

luminaire to provide optimum installation cost and complexity


• Non-maintained and self-
emergency lighting spacing has contained module which only
illuminates in an emergency
resulted in the research and • D40 classification

development of a unique D40 • Simple test button


• Available in DALI for central
LED Emergency Module that can test functions

be discreetly integrated directly in Depth of Range


Emergency Duration: 2 hours.
the luminaire LED: 3W output with less than
1W consumption.
Battery: limited maintenance
battery.
Recharge Period: 16 Hours.
Charging Monitor: LED
Available with DALI for central
monitoring.
Installation/Mounting
Follow installation/mounting
instructions of featuring product.
Provided with flex & plug.
Emergency LED already installed
into the luminaire.
Specification
3W LED Emergency Lighting
with D40 Classification installed
in the luminaires.
As Thorn LED Emergency
Module.

EL2- Emergency LED Standard


EL2X- Emergency LED DALI
Note: Check with your local Sales Representative for luminaire options.

www.thornlighting.com.au Contents Lighting people and places


11
Cadet
T26 (FD) G13 36W
AS/NZS60598 AS/NZS 2293
IP20
Class I Electrical

A slim profile square sided • Built-in end cap spacer for


easy accurate in-line mounting
Materials/Finish
Body: white painted steel.

emergency batten range, with • Double keyhole mounting


holes
End caps: injection moulded
polycarbonate in white.

a selection of attachments
Diffuser: acrylic prismatic.
• Single and twin lamp options
Installation/Mounting
with bare or diffused options
available to suit a variety of • Wide range of attachments
2-way and earth terminal block
with capacity for 2 x 2.5mm2

lighting applications cables. For installation in normal


dry indoor atmospheres.
Specification
To specify state:
Slim cross section emergency
fluorescent batten with clip on
plate with earthing fixation and
diffuser attachment for 36W T26
linear fluorescent lamps.
As Thorn Cadet.

Twin Cadet diffused batten

51.5 51.5

80

Ordering Guide Supplied complete with lamp(s).


Description Ilcos Socket Wt SAP Code C0 C90 C180 85
Code (kg)
Batten
CADET BARE 1x36W E2 LI840 FD G13 2.7 96059840 D50 D16 D50
CADET BARE 2x36W HF E2 LI840 FD G13 3.3 96059843 D25 C40 D40
CADET DIFFUSED 1x36W E2 LI840 FD G13 2.8 96059841 D50 C40 D50
36W - 1222
CADET DIFFUSED 2x36W HF E2 LI840 FD G13 3.7 96059845 C40 D25 D32
Attachments*
Dispersive reflector
CADET DISPERSIVE REFLECTOR 36W 96015824 54.5 54.5

Slotted reflector
CADET SLOTTED REFLECTOR 36W 96015828
90.7
Close end reflector
CADET CLOSE END REFLECTOR 36W 96015733
Angle reflector
120 54.5
CADET ANGLE REFLECTOR 36W 96015730
Wire guard
CADET WIRE GUARD 36W 96032346
Wire guard for close end reflector
CADET CLOSE END WIRE GUARD 36W 96030580 36W - 1225
*Attachments for use with bare batten only. HF- High Frequency ballast, E2- Emergency Standard
Note: Classifications do not apply when attachments are used.

12
Lighting people and places
Contents www.thornlighting.com.au
MaxiBatten
T26 (FD) G13 18-36W
T16 (FD) G5 14-28W
AS/NZS60598 AS/NZS 2293
IP20
Class I Electrical

A modern theme on a • Modular design


• True end to end mounting for
Materials/Finish
Body: robust post powder

traditional product, suited to bare, diffused and wire guard


options
coated steel.
Diffuser: acrylic UV stabilised

domestic, industrial, office


End caps: injection moulded
• Fused terminal block standard polycarbonate.
for high frequency version
and education applications • Wide body
Installation/Mounting
2-way and earth terminal block
with capacity for 2 x 2.5mm2
• Large entry hole
cables. For installation in normal
• Powder coated steel body dry indoor atmospheres.
• Cover clips on and screws in Specification
for added support To specify state:
Wide cross section fluorescent
• Knock out holes in end caps
emergency batten with clip
on plate with earthing fixation
and diffuser attachments for
18/36W T26 and 14/28/35W
T16 linear fluorescent lamps.
As Thorn MaxiBatten.

Ordering Guide Supplied complete with lamp(s).


Description Ilcos Socket Wt SAP Code C0 C90 C180
Code (kg)
T26 versions
MAXIBATTEN BARE 1X36W E2 LI840 FD G13 2.9 96059838 D63 C63 D63
MAXIBATTEN BARE 2X18W HF E2 LI840 FD G13 2.0 96059849 D32 C40 D40
MAXIBATTEN BARE 2X36W HF E2 LI840 FD G13 3.9 96061147 D25 C40 D40
MAXIBATTEN DIFF 1x36W E2 LI840 FD G13 3.3 96059839 D63 C40 D63
MAXIBATTEN DIFF 2X18W HF E2 LI840 FD G13 2.9 96059848 D25 C32 D40
MAXIBATTEN DIFF 2X36W HF E2 LI840 FD G13 4.9 96061148 D20 C25 D40
MaxiBatten lamp single
T16 versions
MAXIBATTEN BARE 2X14W HF E2 LI840 FD G13 2.4 96059337 D50 C16 D50
MAXIBATTEN DIFF 2X14W HF E2 LI840 FD G13 2.4 96059336 D32 C40 D50
MAXIBATTEN BARE 1X28W HF E2 LI840 FD G13 3.1 96040259 D40 C40 D40
MAXIBATTEN DIFF 1x28W HF E2 LI840 FD G13 2.9 96059344 D40 C32 D40
MAXIBATTEN BARE 2X28W HF E2 LI840 FD G13 2.9 96060784 D63 D25 D63
MAXIBATTEN DIFF 2X28W HF E2 LI840 FD G13 3.0 96060261 D50 C50 D63
Dispersive reflector
MAXIBATTEN 1X14W DISPERSIVE REFLECTOR 96039558
MAXIBATTEN 1X28W DISPERSIVE REFLECTOR 96039559
MAXIBATTEN 2X14W DISPERSIVE REFLECTOR 96043173
MAXIBATTEN 2X28W DISPERSIVE REFLECTOR 96043174
MAXIBATTEN 2X36W DISPERSIVE REFLECTOR 96039553
MAXIBATTEN 1X36W DISPERSIVE REFLECTOR 96039556
MaxiBatten lamp twin
MAXIBATTEN 2X18W DISPERSIVE REFLECTOR 96039552
MAXIBATTEN 2X36W DISPERSIVE REFLECTOR 96039553
Wire guard
MAXIBATTEN 1X14W BARE WIREGUARD 96039583
MAXIBATTEN 1X28W BARE WIREGUARD 96039584
MAXIBATTEN 2X14W BARE WIREGUARD 96040564 L

MAXIBATTEN 2X28W BARE WIREGUARD 96040565 Wattage Length 97.5


MAXIBATTEN 1X18W BARE WIREGUARD 96039577 14W 578
MAXIBATTEN 1X36W BARE WIREGUARD 96039578
88.8
18W 619
MAXIBATTEN 218W BARE WIREGUARD 96039580 28W 1178 98.1

MAXIBATTEN 236W BARE WIREGUARD 96039581 36W 1229 115.7


*Attachments for use with bare batten only. HF- High Frequency ballast, E2- Emergency Standard
Note: Classifications do not apply when attachments are used.

www.thornlighting.com.au Contents Lighting people and places


13
College
T16 (FD) G5 28W
AS/NZS60598 AS/NZS 2293
IP44
Class I Electrical

High performance surface/ • Clear prismatic diffuser in


polycarbonate for specific light
Materials/Finish
Body and gear tray: white

suspended fluorescent luminaire control and impact resistance


• Rigidly fixed diffuser held
galvanised prepainted steel.
End caps: polycarbonate.

for schools, colleges and other


Diffuser: precision extruded clear
in place by screwed on
prismatic polycarbonate.
polycarbonate end caps for
educational establishments improved diffuser security and
vandal/impact resistance
Installation/Mounting
Two cable entry holes
(Ø21.5mm) in the centre of
• Easy to remove gear cover the back spine. Optional cable
to protect and cover all entry through each end cap.
components. Lamps are readily Fitting supplied with sealing
accessible without risk of grommets and innovative ‘quick-
electrical contact fix’ horseshoe sliding washers
• Appealing curved shape and for direct screw fixing to surface.
smooth, dust limiting, outer Standard BESA fixings.
surfaces 5 x 2 x 2.5mm² piano key
terminal block suitable for
• Sealed to IP44 easy and quick looping.
• Ease of installation and Specification
cleaning To specify state:
Surface mounted IP44
emergency fluorescent luminaire
with curved clear prismatic
polycarbonate diffuser retained
along its length by screwed on
end caps employing protected
high frequency/twin T16 (T5)
lamps for educational lighting.
As Thorn College.

T5 (T16)
78
217

600

1150

Fixing centres (A)


28W 1150 35/49W 1450
Length
28W 1211 35/49W 1511

Ordering Guide Lamps to be ordered separately.


Description Ilcos Code Socket Wt (kg) SAP Code C0 C90 C180
T16 version
COLLEGE 2x28W HF PC E2 CL FD G5 4.1 96061593 D40 D40 D50
HF - High Frequency, E2- Emergency Standard

14
Lighting people and places
Contents www.thornlighting.com.au
SusTain II T16 (FDH) G5
AS/NZS60598 AS/NZS 2293
IP20
28W

Class I Electrical

A range of high • The ideal solution for shallow


ceiling voids with up to
Materials/Finish
Body: white painted steel.

performance T5 (T16) 40% volume reduction in


comparison with most T8 (T26)
Louvres: satinbrite (SB1) high
performance aluminium.

luminaires offering an all in


luminaires
Installation/Mounting
• The combination of excellent Suitable for most 15 or 24mm
one office lighting solution lumen package, low energy
consumption and lighting
exposed tee ceilings, the
luminaire simply lays into the
controls, is ideal for office, ceiling grid for quick installation.
educational, retail and Luminaire is pre-wired with 1.5m
showrooms where the highest flex and plug and an additional
level of performance is 1.5m flex with round pin earth
required plug for HFX versions. Louvre
simply locks into place via
• Efficient high frequency
concealed clips for ease of lamp
electronic control gear (A2)
maintenance.
• DALI/DSI versions (A1)
Specification
• Protective film as standard To specify state:
Recessed T16 emergency
• Airhandling version available
modular or non-modular
on request
luminaire with high performance
• Sensa Digital available on louvre.
request Up to 90%.
As Thorn SusTain II.
• Option of plaster recessed
installation using PPF frame
(to be ordered separately)
• Surface versions available
to special order
• Volume reduction facilities
save on storage, transport and
installation costs
• Even light distribution with
LOR’s up to 90%
• Specifically designed to ensure
lamps run at their optimal
temperature
• High performance aluminium
60
used in satinbrite lourve
295
• Optimum uniformity and
soft all round glare control
conforming to relevant
standards, overall offering
maximum efficiency
• Different lamp power or
custom dimension available on 1195
request

Ordering Guide
Supplied complete with lamp(s) (840) and Flex & Plug.
Description Wt (Kg) SAP Code C0 C90 C180
Stainbrite Louvre SB1
SU2 1x28W HF 12x3 LI840 SB1 EL2 3.7 96537127 D40 D40 D40
SU2 2x28W HF 12x3 LI840 SB2 EL2 4.1 96537897 D40 D40 D40
HF - High Frequency (A2), MB - Mirrorbrite, SB1 - Satinbrite, SB2 - Satinbrite, LI840 - Lamp included 4000K. Wide selection of lamps
available on request.

www.thornlighting.com.au Contents Lighting people and places


15
Danube
TC-DD (FSS) GR8 28W
TC-DDEL (FSS) GR10q 28W
AS/NZS60598 AS/NZS 2293
IP65
Class I Electrical

Danube utilises a flat front • Flat fronted opal


polycarbonate diffuser
Materials/Finish
Body: diecast aluminium.

diffuser and bold flared sides • Available in black or white


Diffuser: opal polycarbonate.
Bezel: polycarbonate, white or

to create a low profile luminaire


• IP65 for exterior installations black finish.
•Q
 uick Fix Bracket supplied for Installation/Mounting
safe and quick installation Suitable for surface mounting on
wall or ceiling for both interior
and exterior use. ‘Quick Fix
Bracket’ (QFB) screw fixed onto
mounting surface by 4 oblong
holes (4.5mm x 10mm). Main
connection via 6 way connecting
block. ‘Light Box’ direct and
auto-connected to the QFB. For
loop wiring a double 20mm
cable entry holes to rear of QFB.
Specification
To specify state:
Bold and versatile circular
emergency, 28W TC-DD/ 28W
TC-DDEL, compact fluorescent
lamps, ‘flat’ opal diffuser with
black or white bezel option,
magnetic or electronic control
gear, connected to Quick Fix
Wall and Ceiling Bracket.
As Thorn Danube.

Ø 414.7

Ø 336.4

54 81

Round black

Ordering Guide Supplied complete with lamp and Quick Fix Bracket.
Description Ilcos Code Socket Wt (kg) SAP Code C0 C90 C180
Opal diffuser-round Large
DA 1X28W TC-DD CP E2 CL1 OP RD L AL BLK FSS GR8 2.0 96537024 D20 D20 D20
DA 1X28W TC-DDEL HF E2 OP RD L AL WHI FSS GR10Q 1.6 96062579 D20 D20 D20
For large projects with first and second fix requirements the Quick Fix Bracket can be ordered as an individual item
HF - High Frequency, OP- Opal Version, CP - Magnetic (parallel compensated), CL1 - Class I Electrical ,E2- Emergency Standard Maintained

16
Lighting people and places
Contents www.thornlighting.com.au
ImpactForce II

T26 (FD)
T16 (FDH)
AS/NZS 60598
G13
G5
18-36W
14-28W
AS/NZS 2293
IK03 (canopy) IK07 (diffuser)
IP65
Class I Electrical

A high performance impact •G


 lass-fibre reinforced
polyester (GRP) canopy
Materials/Finish
Canopy: glass-fibre

resistant IP65 emergency proof • High impact polycarbonate


diffuser
reinforced polyester.
Diffuser: polycarbonate with

fluorescent luminaire range


linear prisms.
• High Frequency control gear Gasket: expanded polyurethane.
Toggles: stainless steel.
• Horizontal or vertical
Gear tray: steel, white
mounting
enamelled finish.
• Stainless steel toggles
Installation/Mounting
• Supplied complete with Cable entry positions at the
quick-fix brackets back and each end of the fitting.
Supplied with IP65 grommet.
Stainless steel quick fix brackets
supplied with each luminaire.
Stainless steel toggles are
captive in the canopy to prevent
loss during maintenance.
Steel gear tray is retained by
finger operated spring latches.
Accessory kits for BESA box
mounting, conduit mounting,
chain suspension and catenary
suspension are all available.
Specification
To specify state:
High performance, emergency,
IP65, dust and moisture proof
impact resistant luminaire with
GRP canopy, polycarbonate
diffuser and stainless steel
toggles. 18-36W T26 (T8)
linear fluorescent lamps or
14-28W T16 (T5) linear
fluorescent lamps, with HF gear.
As Thorn ImpactForce II.

32

113

111

287 720 32

124 156

1294 28W/36W

Single lamp version

70

Ordering Guide Lamps to be ordered separately. 125

166

Description Ilcos Code Socket Wt (kg) SAP Code C0 C90 C180


177 330
T16 High Frequency 287 720
32

IMPACTF2 2X14W T16 HF E2 FDH G5 2.6 96061318 D20 C32 D25


IMPACTF2 1X28W T16 HF E2 FDH G5 2.9 96061314 D50 C40 D50
IMPACTF2 2X28W T16 HF E2 FDH G5 3.6 96061315 D63 C63 D63 74 106
156
T26 High Frequency 124

684 14W/18W
IMPACTF2 2X18W T26 HF E2 FD G13 2.6 96061319 D20 C20 D16 1294 28W/36W
IMPACTF2 1X36W T26 HF E2 FD G13 2.9 96061316 D20 C20 D20
IMPACTF2 2X36W T26 HF E2 FD G13 3.4 96061317 D40 C40 D32 Twin lamps version
HF - High frequency, E2 - 2 hour maintained emergency

www.thornlighting.com.au Contents Lighting people and places


17
CorrosionForce II

T26 (FD)
T16 (FDH)
AS/NZS 60598
G13
G5
18-36W
14-28W
AS/NZS 2293
IK02 (diffuser) IK03 (canopy)
IP65
Class I Electrical

A high performance, corrosion • Glass-fibre reinforced polyester


(GRP) canopy
Materials/Finish
Canopy: glass-fibre

resistant IP65 emergency • Corrosion resistant PMMA


(acrylic) diffuser
reinforced polyester.
Diffuser: AC with linear prisms.

fluorescent luminaire range. • High Frequency control gear


Gasket: expanded
polyurethane.

Made from materials selected to • Good chemical resistance


Toggles: stainless steel.
Gear tray: steel, white

withstand aggressive atmospheres • Horizontal or vertical mounting


• Stainless steel toggles
enamelled finish.
Installation/Mounting
laden with salts, acids and • Supplied complete with
Cable entry positions at the
back and each end of the
quick-fix brackets
mineral oils fitting. Supplied with IP65
grommet. Stainless steel quick
fix brackets supplied with each
luminaire. Stainless steel toggles
are captive in the canopy to
prevent loss during maintenance.
Steel gear tray is retained by
finger operated spring latches.
Accessory kits for BESA box
mounting, conduit mounting,
chain suspension and catenary
suspension are all available.
Specification
To specify state:
High performance emergency,
IP65, dust and moisture proof
corrosion resistant luminaire with
GRP canopy, AC diffuser and
stainless steel toggles. 18-36W
T26 (T8) linear fluorescent lamps
or 14-28W T16 (T5) linear
fluorescent lamps, with HF gear.
As Thorn CorrosionForce II.

32

113

111

287 720 32

124 216

1294 28W/36W

Single lamp version

70

125
Ordering Guide Lamps to be ordered separately. 166

Description Ilcos Code Socket Wt (kg) SAP Code C0 C90 C180


177 330
32
T16 High Frequency 287 720

CORRF2 2X14W T16 HF E2 FDH G5 2.6 96061324 D20 C32 D25


CORRF2 1X28W T16 HF E2 FDH G5 2.9 96064122 D50 C50 D50
CORRF2 2X28W T16 HF E2 FDH G5 3.6 96061321 D63 C63 D63 74 106
124 216
T26 High Frequency
684 14W/18W
CORRF2 2X18W T26 HF E2 FD G13 2.6 96061325 D20 C20 D20 1294 28W/36W

CORRF2 1X36W T26 HF E2 FD G13 2.9 96061322 D20 C20 D20


CORRF2 2X36W T26 HF E2 FD G13 3.4 96061323 D40 C40 D40 Twin lamp version
HF - High frequency, E2 - 2 hour maintained emergency

18 Contents www.thornlighting.com.au
Lighting people and places
WeatherForce
T26 (FD) G13 18-36W
T16 (FDH) G5 14-28W
AS/NZS 60598 AS/NZS 2293
IP65
Class I Electrical

An easy to use weatherproof • Injection moulded body


and diffuser
Materials/Finish
Body: canopy injection moulded

emergency fluorescent • Accurate mouldings with


a deep sealing channel to
polycarbonate in light grey.
Diffuser: injection moulded UV

luminaire with IP65 protection,


stabilised clear polycarbonate.
ensure IP65 resistance
Gear tray: sheet steel, white
• UV stabilised polycarbonate powdercoat paint finish.
specifically designed for diffuser for maximum impact Toggles: stainless steel.
resistance
general outdoor applications • High frequency control gear
Installation/Mounting
Cable entry positions at each
end of fitting. Screw fixing
• Stainless steel toggles
through identified locations
(301 grade)
in back of fitting. Toggles are
easy and quick to close by
hand. (Basic Tool required to
open toggles). Suspension kits
available to special order.
Specification
To specify state:
Weatherproof IP65 fluorescent
fitting with injection moulded
polycarbonate body and
polycarbonate diffuser for T26
or T16 lamps with integrated
emergency High Frequency gear.
As Thorn Weatherforce.

112
112

100 155

Height Width Length


2x14/18W 112 155 660
1x28/36W 112 100 1270
2x28/36W 112 155 1270

Ordering Guide Supplied complete with lamp.


Description Ilcos Code Socket Wt SAP Code C0 C90 C180
(kg)
T16 High Frequency
WEATHERFORCE T16 2X14 HF E2 LI840 FDH G5 2.9 96058443 D25 C40 D32
WEATHERFORCE T16 1X28 HF E2 LI840 FDH G5 3.0 96059345 D63 C40 D63
WEATHERFORCE T16 2X28 HF E2 LI840 FDH G5 3.7 96058445 D50 C63 D63
T26 High Frequency
WEATHERFORCE T26 2X18 HF E2 LI840 FD G13 2.9 96040892 D16 C25 D25
WEATHERFORCE T26 1X36 HF E2 LI840 FD G13 3.0 96059784 D32 C25 D32
WEATHERFORCE T26 2X36 HF E2 LI840 FD G13 3.7 96060109 D32 C40 D40
E2 - 2 hour maintained emergency, HF- High Frequency Ballast

www.thornlighting.com.au Contents 19
Lighting people and places
Voyager Dali Central
Class I Electrical
IP20

Monitoring

A simple touch screen • Ability to control and monitor


up to 120 individual DALI
Materials/Finish
Panel with silver aluminium

(e-touchPANEL) based based emergency units such as


Thorn DALI Emergency devices
frame.
Installation/Mounting
emergency monitoring system
and Tridonic PRO emergency
Simple fixing with two screws at
devices
the back for wall mounting.
• Function tests and duration
Specification
tests can be scheduled in
To specify state:
accordance with the local
Fully compatible with Thorn DALI
regulations
Emergency devices.
As Thorn Voyager Dali Central
Monitoring.

19
38
184
200

Ordering Guide Complete with 24V power supply.

150
Description Wt (kg) SAP Code
VOYAGER (A) DALI CENTRAL MONITORING 0.4 24139117

20
Lighting people and places
Contents www.thornlighting.com.au
Maximum Emergency Spacing/Mounting Height (m)
SAP
codes Description Classification 2.1 2.4 2.7 3.0 3.3 3.6 4.0 4.5 5.0 6.0 7.0 8.0 9.0 10.0 15.0 20.0
96066756 VOYAGER (A) LED C0 D40 16.7 17.4 18.0 18.6 19.1 19.6 20.1 20.8 21.3 22.1 22.7 23.0 23.1 23.1 19.4 -
DISK 3W EL2
C90 D40 16.7 17.4 18.0 18.6 19.1 19.6 20.1 20.8 21.3 22.1 22.7 23.0 23.1 23.1 19.4 -
C180 D40 16.7 17.4 18.0 18.6 19.1 19.6 20.1 20.8 21.3 22.1 22.7 23.0 23.1 23.1 19.4 -
96066761 VOYAGER (A) LED C0 D40 16.7 17.4 18.0 18.6 19.1 19.6 20.1 20.8 21.3 22.1 22.7 23.0 23.1 23.1 19.4 -
DISK 3W EL2X
C90 D40 16.7 17.4 18.0 18.6 19.1 19.6 20.1 20.8 21.3 22.1 22.7 23.0 23.1 23.1 19.4 -
C180 D40 16.7 17.4 18.0 18.6 19.1 19.6 20.1 20.8 21.3 22.1 22.7 23.0 23.1 23.1 19.4 -
96066757 VOYAGER (A) C0 C12.5 7.8 8.2 8.6 8.9 9.2 9.5 9.8 10.0 10.2 10.3 10.1 9.4 8.3 6.5 - -
LED BLD EXIT 3W
C90 C12.5 7.8 8.2 8.6 8.9 9.2 9.5 9.8 10.0 10.2 10.3 10.1 9.4 8.3 6.5 - -
EL2 WH
C180 C12.5 7.8 8.2 8.6 8.9 9.2 9.5 9.8 10.0 10.2 10.3 10.1 9.4 8.3 6.5 - -
96066758 VOYAGER (A) C0 C12.5 7.8 8.2 8.6 8.9 9.2 9.5 9.8 10.0 10.2 10.3 10.1 9.4 8.3 6.5 - -
LED BLD EXIT 3W
C90 C12.5 7.8 8.2 8.6 8.9 9.2 9.5 9.8 10.0 10.2 10.3 10.1 9.4 8.3 6.5 - -
EL2 SI
C180 C12.5 7.8 8.2 8.6 8.9 9.2 9.5 9.8 10.0 10.2 10.3 10.1 9.4 8.3 6.5 - -
96066762 VOYAGER (A) LED C0 C12.5 7.8 8.2 8.6 8.9 9.2 9.5 9.8 10.0 10.2 10.3 10.1 9.4 8.3 6.5 - -
BLD EXIT 3W EL2X
C90 C12.5 7.8 8.2 8.6 8.9 9.2 9.5 9.8 10.0 10.2 10.3 10.1 9.4 8.3 6.5 - -
WH
C180 C12.5 7.8 8.2 8.6 8.9 9.2 9.5 9.8 10.0 10.2 10.3 10.1 9.4 8.3 6.5 - -
96066763 VOYAGER (A) C0 C12.5 7.8 8.2 8.6 8.9 9.2 9.5 9.8 10.0 10.2 10.3 10.1 9.4 8.3 6.5 - -
LED BLD EXIT 3W
C90 C12.5 7.8 8.2 8.6 8.9 9.2 9.5 9.8 10.0 10.2 10.3 10.1 9.4 8.3 6.5 - -
EL2X SI
C180 C12.5 7.8 8.2 8.6 8.9 9.2 9.5 9.8 10.0 10.2 10.3 10.1 9.4 8.3 6.5 - -
96059840 CADET BARE 1X36 C0 D50 18.0 18.7 19.4 20.1 20.7 21.2 21.8 22.5 23.2 24.2 24.9 25.4 25.7 25.9 23.7 15.2
E2 LI840
C90 D16 12.1 12.6 13.0 13.3 13.6 13.9 14.1 14.6 14.6 14.6 14.4 13.8 12.9 11.5 - -
C180 D50 18.0 18.7 19.4 20.1 20.7 21.2 21.8 22.5 23.2 24.2 24.9 25.4 25.7 25.9 23.7 15.2
96059843 CADET BARE 2X36 C0 D25 14.2 14.7 15.3 15.7 16.1 16.5 16.9 17.3 17.7 18.1 18.3 18.2 17.9 17.3 7.7 -
HF E2 LI840
C90 C40 10.6 11.3 12.0 12.6 13.1 13.6 14.3 15.0 15.6 16.6 17.4 17.9 18.3 18.5 16.2 -
C180 D40 16.7 17.4 18.0 18.6 19.1 19.6 20.1 20.8 21.3 22.1 22.7 23.0 23.1 23.1 19.4 -
96059841 CADET DIFFUSED C0 D50 18.0 18.7 19.4 20.1 20.7 21.2 21.8 22.5 23.2 24.2 24.9 25.4 25.7 25.9 23.7 15.2
1X36 E2 LI840
C90 C40 10.6 11.3 12.0 12.6 13.1 13.6 14.3 15.0 15.6 16.6 17.4 17.9 18.3 18.5 16.2 -
C180 D50 18.0 18.7 19.4 20.1 20.7 21.2 21.8 22.5 23.2 24.2 24.9 25.4 25.7 25.9 23.7 15.2
96059845 CADET DIFFUSED C0 C40 10.6 11.3 12.0 12.6 13.1 13.6 14.3 15.0 15.6 16.6 17.4 17.9 18.3 18.5 16.2 -
2X36W HF E2
C90 C25 9.4 10.0 10.5 11.0 11.5 11.9 12.4 12.9 13.4 14.0 14.4 14.6 14.5 14.2 6.6 -
LI840
C180 D32 15.4 16.1 16.7 17.2 17.6 18.0 18.5 19.1 19.5 20.2 20.6 20.7 20.6 20.3 14.6 -
96059838 MAXIBATTEN BARE C0 D63 19.4 20.3 21.1 21.8 22.4 23.0 23.7 24.5 25.2 26.4 27.4 28.1 28.6 28.9 28.0 22.5
1X36W E2 LI840
C90 C63 11.9 12.8 13.5 14.2 14.9 15.5 16.2 17.1 17.9 19.2 20.3 21.2 22.0 22.5 22.9 18.9
C180 D63 19.4 20.3 21.1 21.8 22.4 23.0 23.7 24.5 25.2 26.4 27.4 28.1 28.6 28.9 28.0 22.5
96059849 MAXIBATTEN BARE C0 D32 15.4 16.1 16.7 17.2 17.6 18.0 18.5 19.1 19.5 20.2 20.6 20.7 20.6 20.3 14.6 -
2X18W HF E2
C90 C40 10.6 11.3 12.0 12.6 13.1 13.6 14.3 15.0 15.6 16.6 17.4 17.9 18.3 18.5 16.2 -
LI840
C180 D40 16.7 17.4 18.0 18.6 19.1 19.6 20.1 20.8 21.3 22.1 22.7 23.0 23.1 23.1 19.4 -
96061147 MAXIBATTEN BARE C0 D25 14.2 14.7 15.3 15.7 16.1 16.5 16.9 17.3 17.7 18.1 18.3 18.2 17.9 17.3 7.7 -
2X36W HF E2
C90 C40 10.6 11.3 12.0 12.6 13.1 13.6 14.3 15.0 15.6 16.6 17.4 17.9 18.3 18.5 16.2 -
LI840
C180 D40 16.7 17.4 18.0 18.6 19.1 19.6 20.1 20.8 21.3 22.1 22.7 23.0 23.1 23.1 19.4 -
96059839 MAXIBATTEN DIFF C0 D63 19.4 20.3 21.1 21.8 22.4 23.0 23.7 24.5 25.2 26.4 27.4 28.1 28.6 28.9 28.0 22.5
1X36W E2 LI840
C90 C40 10.6 11.3 12.0 12.6 13.1 13.6 14.3 15.0 15.6 16.6 17.4 17.9 18.3 18.5 16.2 -
C180 D63 19.4 20.3 21.1 21.8 22.4 23.0 23.7 24.5 25.2 26.4 27.4 28.1 28.6 28.9 28.0 22.5
96059848 MAXIBATTEN DIFF C0 D25 14.2 14.7 15.3 15.7 16.1 16.5 16.9 17.3 17.7 18.1 18.3 18.2 17.9 17.3 7.7 -
2X18W HF E2
C90 C32 10.0 10.7 11.3 11.8 12.3 12.8 13.4 14.0 14.5 15.4 16.0 16.4 16.5 16.5 12.3 -
LI840
C180 D40 16.7 17.4 18.0 18.6 19.1 19.6 20.1 20.8 21.3 22.1 22.7 23.0 23.1 23.1 19.4 -
96061148 MAXIBATTEN DIFF C0 D20 13.1 13.6 14.1 14.5 14.8 15.1 15.5 15.8 16.1 16.4 16.3 16.0 15.4 14.5 - -
2X36W HF E2
C90 C25 9.4 10.0 10.5 11.0 11.5 11.9 12.4 12.9 13.4 14.0 14.4 14.6 14.5 14.2 6.6 -
LI840
C180 D40 16.7 17.4 18.0 18.6 19.1 19.6 20.1 20.8 21.3 22.1 22.7 23.0 23.1 23.1 19.4 -
96059337 MAXIBATTEN BARE C0 D50 18.0 18.7 19.4 20.1 20.7 21.2 21.8 22.5 23.2 24.2 24.9 25.4 25.7 25.9 23.7 15.2
2X14W HF E2
C90 D16 12.1 12.6 13.0 13.3 13.6 13.9 14.1 14.6 14.6 14.6 14.4 13.8 12.9 11.5 - -
LI840
C180 D50 18.0 18.7 19.4 20.1 20.7 21.2 21.8 22.5 23.2 24.2 24.9 25.4 25.7 25.9 23.7 15.2
96059336 MAXIBATTEN DIFF C0 D32 15.4 16.1 16.7 17.2 17.6 18.0 18.5 19.1 19.5 20.2 20.6 20.7 20.6 20.3 14.6 -
2X14W HF E2
C90 C40 10.6 11.3 12.0 12.6 13.1 13.6 14.3 15.0 15.6 16.6 17.4 17.9 18.3 18.5 16.2 -
LI840
C180 D50 18.0 18.7 19.4 20.1 20.7 21.2 21.8 22.5 23.2 24.2 24.9 25.4 25.7 25.9 23.7 15.2
96040259 MAXIBATTEN BARE C0 D40 16.7 17.4 18.0 18.6 19.1 19.6 20.1 20.8 21.3 22.1 22.7 23.0 23.1 23.1 19.4 -
1X28W HF E2
LI840 C90 C40 10.6 11.3 12.0 12.6 13.1 13.6 14.3 15.0 15.6 16.6 17.4 17.9 18.3 18.5 16.2 -
C180 D40 16.7 17.4 18.0 18.6 19.1 19.6 20.1 20.8 21.3 22.1 22.7 23.0 23.1 23.1 19.4 -
96059344 MAXIBATTEN DIFF C0 D40 16.7 17.4 18.0 18.6 19.1 19.6 20.1 20.8 21.3 22.1 22.7 23.0 23.1 23.1 19.4 -
1X28W HF E2
LI840 C90 C32 10.0 10.7 11.3 11.8 12.3 12.8 13.4 14.0 14.5 15.4 16.0 16.4 16.5 16.5 12.3 -
C180 D40 16.7 17.4 18.0 18.6 19.1 19.6 20.1 20.8 21.3 22.1 22.7 23.0 23.1 23.1 19.4 -
96060784 MAXIBATTEN BARE C0 D63 19.4 20.3 21.1 21.8 22.4 23.0 23.7 24.5 25.2 26.4 27.4 28.1 28.6 28.9 28.0 22.5
2X28W HF E2
C90 D25 14.2 14.7 15.3 15.7 16.1 16.5 16.9 17.3 17.7 18.1 18.3 18.2 17.9 17.3 7.7 -
LI840
C180 D63 19.4 20.3 21.1 21.8 22.4 23.0 23.7 24.5 25.2 26.4 27.4 28.1 28.6 28.9 28.0 22.5
96060261 MAXIBATTEN DIFF C0 D50 18.0 18.7 19.4 20.1 20.7 21.2 21.8 22.5 23.2 24.2 24.9 25.4 25.7 25.9 23.7 15.2
2X28W HF E2
LI840 C90 C50 11.3 12.0 12.7 13.4 14.0 14.5 15.2 16.0 16.7 17.9 18.8 19.6 20.1 20.4 19.6 12.9
C180 D63 19.4 20.3 21.1 21.8 22.4 23.0 23.7 24.5 25.2 26.4 27.4 28.1 28.6 28.9 28.0 22.5
96061593 COLLEGE 2X28W C0 D40 16.7 17.4 18.0 18.6 19.1 19.6 20.1 20.8 21.3 22.1 22.7 23.0 23.1 23.1 19.4 -
HF PC E2 CL
C90 C40 10.6 11.3 12.0 12.6 13.1 13.6 14.3 15.0 15.6 16.6 17.4 17.9 18.3 18.5 16.2 -
C180 D50 18.0 18.7 19.4 20.1 20.7 21.2 21.8 22.5 23.2 24.2 24.9 25.4 25.7 25.9 23.7 15.2

22
Lighting people and places
Contents www.thornlighting.com.au
Maximum Emergency Spacing/Mounting Height (m)
SAP
codes Description Classification 2.1 2.4 2.7 3.0 3.3 3.6 4.0 4.5 5.0 6.0 7.0 8.0 9.0 10.0 15.0 20.0
96537127 SU2 1X28W HF C0 D40 16.7 17.4 18.0 18.6 19.1 19.6 20.1 20.8 21.3 22.1 22.7 23.0 23.1 23.1 19.4 -
12X3 LI840 SB1
C90 D40 16.7 17.4 18.0 18.6 19.1 19.6 20.1 20.8 21.3 22.1 22.7 23.0 23.1 23.1 19.4 -
EL2
C180 D40 16.7 17.4 18.0 18.6 19.1 19.6 20.1 20.8 21.3 22.1 22.7 23.0 23.1 23.1 19.4 -
96537897 SU2 2X28W HF C0 D40 16.7 17.4 18.0 18.6 19.1 19.6 20.1 20.8 21.3 22.1 22.7 23.0 23.1 23.1 19.4 -
12X3 LI840 SB2
C90 D40 16.7 17.4 18.0 18.6 19.1 19.6 20.1 20.8 21.3 22.1 22.7 23.0 23.1 23.1 19.4 -
EL2
C180 D40 16.7 17.4 18.0 18.6 19.1 19.6 20.1 20.8 21.3 22.1 22.7 23.0 23.1 23.1 19.4 -
96537024 DA 1X28W TC-DD C0 D20 13.1 13.6 14.1 14.5 14.8 15.1 15.5 15.8 16.1 16.4 16.3 16.0 15.4 14.5 - -
E2M CP CL1 OP
C90 D20 13.1 13.6 14.1 14.5 14.8 15.1 15.5 15.8 16.1 16.4 16.3 16.0 15.4 14.5 - -
RD L AL BLK
C180 D20 13.1 13.6 14.1 14.5 14.8 15.1 15.5 15.8 16.1 16.4 16.3 16.0 15.4 14.5 - -
96062579 DA 1X28W 2D HF C0 D20 13.1 13.6 14.1 14.5 14.8 15.1 15.5 15.8 16.1 16.4 16.3 16.0 15.4 14.5 - -
E2M OP RD L AL
C90 D20 13.1 13.6 14.1 14.5 14.8 15.1 15.5 15.8 16.1 16.4 16.3 16.0 15.4 14.5 - -
WHI S/W
C180 D20 13.1 13.6 14.1 14.5 14.8 15.1 15.5 15.8 16.1 16.4 16.3 16.0 15.4 14.5 - -
96061318 IMPACTF2 2X14W C0 D20 13.1 13.6 14.1 14.5 14.8 15.1 15.5 15.8 16.1 16.4 16.3 16.0 15.4 14.5 - -
T16 HF E2
C90 C32 10.0 10.7 11.3 11.8 12.3 12.8 13.4 14.0 14.5 15.4 16.0 16.4 16.5 16.5 12.3 -
C180 D25 14.2 14.7 15.3 15.7 16.1 16.5 16.9 17.3 17.7 18.1 18.3 18.2 17.9 17.3 7.7 -
96061314 IMPACTF2 1X28W C0 D50 18.0 18.7 19.4 20.1 20.7 21.2 21.8 22.5 23.2 24.2 24.9 25.4 25.7 25.9 23.7 15.2
T16 HF E2
C90 C40 10.6 11.3 12.0 12.6 13.1 13.6 14.3 15.0 15.6 16.6 17.4 17.9 18.3 18.5 16.2 -
C180 D50 18.0 18.7 19.4 20.1 20.7 21.2 21.8 22.5 23.2 24.2 24.9 25.4 25.7 25.9 23.7 15.2
96061315 IMPACTF2 2X28W C0 D63 19.4 20.3 21.1 21.8 22.4 23.0 23.7 24.5 25.2 26.4 27.4 28.1 28.6 28.9 28.0 22.5
T16 HF E2
C90 C63 11.9 12.8 13.5 14.2 14.9 15.5 16.2 17.1 17.9 19.2 20.3 21.2 22.0 22.5 22.9 18.9
C180 D63 19.4 20.3 21.1 21.8 22.4 23.0 23.7 24.5 25.2 26.4 27.4 28.1 28.6 28.9 28.0 22.5
96061319 IMPACTF2 2X18W C0 D20 13.1 13.6 14.1 14.5 14.8 15.1 15.5 15.8 16.1 16.4 16.3 16.0 15.4 14.5 - -
T26 HF E2
C90 C20 8.9 9.4 9.9 10.3 10.7 11.1 11.5 12.0 12.3 12.8 13.0 13.0 12.7 12.0 - -
C180 D16 12.1 12.6 13.0 13.3 13.6 13.9 14.1 14.6 14.6 14.6 14.4 13.8 12.9 11.5 - -
96061316 IMPACTF2 1X36W C0 D20 13.1 13.6 14.1 14.5 14.8 15.1 15.5 15.8 16.1 16.4 16.3 16.0 15.4 14.5 - -
T26 HF E2
C90 C20 8.9 9.4 9.9 10.3 10.7 11.1 11.5 12.0 12.3 12.8 13.0 13.0 12.7 12.0 - -
C180 D20 13.1 13.6 14.1 14.5 14.8 15.1 15.5 15.8 16.1 16.4 16.3 16.0 15.4 14.5 - -
96061317 IMPACTF2 2X36W C0 D40 16.7 17.4 18.0 18.6 19.1 19.6 20.1 20.8 21.3 22.1 22.7 23.0 23.1 23.1 19.4 -
T26 HF E2
C90 C40 10.6 11.3 12.0 12.6 13.1 13.6 14.3 15.0 15.6 16.6 17.4 17.9 18.3 18.5 16.2 -
C180 D32 15.4 16.1 16.7 17.2 17.6 18.0 18.5 19.1 19.5 20.2 20.6 20.7 20.6 20.3 14.6 -
96061324 CORRF2 2X14W C0 D20 13.1 13.6 14.1 14.5 14.8 15.1 15.5 15.8 16.1 16.4 16.3 16.0 15.4 14.5 - -
T16 HF E2
C90 C32 10.0 10.7 11.3 11.8 12.3 12.8 13.4 14.0 14.5 15.4 16.0 16.4 16.5 16.5 12.3 -
C180 D25 14.2 14.7 15.3 15.7 16.1 16.5 16.9 17.3 17.7 18.1 18.3 18.2 17.9 17.3 7.7 -
96064122 CORRF2 1X28W C0 D50 18.0 18.7 19.4 20.1 20.7 21.2 21.8 22.5 23.2 24.2 24.9 25.4 25.7 25.9 23.7 15.2
T16 HF E2
C90 C50 11.3 12.0 12.7 13.4 14.0 14.5 15.2 16.0 16.7 17.9 18.8 19.6 20.1 20.4 19.6 12.9
C180 D50 18.0 18.7 19.4 20.1 20.7 21.2 21.8 22.5 23.2 24.2 24.9 25.4 25.7 25.9 23.7 15.2
96061321 CORRF2 2X28W C0 D63 19.4 20.3 21.1 21.8 22.4 23.0 23.7 24.5 25.2 26.4 27.4 28.1 28.6 28.9 28.0 22.5
T16 HF E2
C90 C63 11.9 12.8 13.5 14.2 14.9 15.5 16.2 17.1 17.9 19.2 20.3 21.2 22.0 22.5 22.9 18.9
C180 D63 19.4 20.3 21.1 21.8 22.4 23.0 23.7 24.5 25.2 26.4 27.4 28.1 28.6 28.9 28.0 22.5
96061325 CORRF2 2X18W C0 D20 13.1 13.6 14.1 14.5 14.8 15.1 15.5 15.8 16.1 16.4 16.3 16.0 15.4 14.5 - -
T26 HF E2
C90 C20 8.9 9.4 9.9 10.3 10.7 11.1 11.5 12.0 12.3 12.8 13.0 13.0 12.7 12.0 - -
C180 D20 13.1 13.6 14.1 14.5 14.8 15.1 15.5 15.8 16.1 16.4 16.3 16.0 15.4 14.5 - -
96061322 CORRF2 1X36W C0 D20 13.1 13.6 14.1 14.5 14.8 15.1 15.5 15.8 16.1 16.4 16.3 16.0 15.4 14.5 - -
T26 HF E2
C90 C20 8.9 9.4 9.9 10.3 10.7 11.1 11.5 12.0 12.3 12.8 13.0 13.0 12.7 12.0 - -
C180 D20 13.1 13.6 14.1 14.5 14.8 15.1 15.5 15.8 16.1 16.4 16.3 16.0 15.4 14.5 - -
96061323 CORRF2 2X36W C0 D40 16.7 17.4 18.0 18.6 19.1 19.6 20.1 20.8 21.3 22.1 22.7 23.0 23.1 23.1 19.4 -
T26 HF E2
C90 C40 10.6 11.3 12.0 12.6 13.1 13.6 14.3 15.0 15.6 16.6 17.4 17.9 18.3 18.5 16.2 -
C180 D40 16.7 17.4 18.0 18.6 19.1 19.6 20.1 20.8 21.3 22.1 22.7 23.0 23.1 23.1 19.4 -
96058443 WEATHERFORCE C0 D25 14.2 14.7 15.3 15.7 16.1 16.5 16.9 17.3 17.7 18.1 18.3 18.2 17.9 17.3 7.7 -
T16 2X14 E2
C90 C40 10.6 11.3 12.0 12.6 13.1 13.6 14.3 15.0 15.6 16.6 17.4 17.9 18.3 18.5 16.2 -
C180 D32 15.4 16.1 16.7 17.2 17.6 18.0 18.5 19.1 19.5 20.2 20.6 20.7 20.6 20.3 14.6 -
96059345 WEATHERFORCE C0 D63 19.4 20.3 21.1 21.8 22.4 23.0 23.7 24.5 25.2 26.4 27.4 28.1 28.6 28.9 28.0 22.5
T16 1X28 E2
C90 C40 10.6 11.3 12.0 12.6 13.1 13.6 14.3 15.0 15.6 16.6 17.4 17.9 18.3 18.5 16.2 -
C180 D63 19.4 20.3 21.1 21.8 22.4 23.0 23.7 24.5 25.2 26.4 27.4 28.1 28.6 28.9 28.0 22.5
96058445 WEATHERFORCE C0 D50 18.0 18.7 19.4 20.1 20.7 21.2 21.8 22.5 23.2 24.2 24.9 25.4 25.7 25.9 23.7 15.2
T16 2X28 E2
C90 C63 11.9 12.8 13.5 14.2 14.9 15.5 16.2 17.1 17.9 19.2 20.3 21.2 22.0 22.5 22.9 18.9
C180 D63 19.4 20.3 21.1 21.8 22.4 23.0 23.7 24.5 25.2 26.4 27.4 28.1 28.6 28.9 28.0 22.5
96040892 WEATHERFORCE C0 D16 12.1 12.6 13.0 13.3 13.6 13.9 14.1 14.6 14.6 14.6 14.4 13.8 12.9 11.5 - -
T26 2X18 HF E2
C90 C25 9.4 10.0 10.5 11.0 11.5 11.9 12.4 12.9 13.4 14.0 14.4 14.6 14.5 14.2 6.6 -
C180 D25 14.2 14.7 15.3 15.7 16.1 16.5 16.9 17.3 17.7 18.1 18.3 18.2 17.9 17.3 7.7 -
96059784 WEATHERFORCE C0 D32 15.4 16.1 16.7 17.2 17.6 18.0 18.5 19.1 19.5 20.2 20.6 20.7 20.6 20.3 14.6 -
T26 1X36 HF E2
C90 C25 9.4 10.0 10.5 11.0 11.5 11.9 12.4 12.9 13.4 14.0 14.4 14.6 14.5 14.2 6.6 -
C180 D32 15.4 16.1 16.7 17.2 17.6 18.0 18.5 19.1 19.5 20.2 20.6 20.7 20.6 20.3 14.6 -
96060109 WEATHERFORCE C0 D32 15.4 16.1 16.7 17.2 17.6 18.0 18.5 19.1 19.5 20.2 20.6 20.7 20.6 20.3 14.6 -
T26 2X36 HF E2
C90 C40 10.6 11.3 12.0 12.6 13.1 13.6 14.3 15.0 15.6 16.6 17.4 17.9 18.3 18.5 16.2 -
C180 D40 16.7 17.4 18.0 18.6 19.1 19.6 20.1 20.8 21.3 22.1 22.7 23.0 23.1 23.1 19.4 -
Note: Maximum Spacing for mounting heights between the values given in the Table may be obtained by interpolation.

www.thornlighting.com.au Contents Lighting people and places


23
Head Office
Australia
Sydney
Thorn Lighting Pty Limited
43 Newton Road
Wetherill Park NSW 2164
Tel: (02) 8786 6000
Fax: (02) 9612 2700
e-mail: [email protected]
www.thornlighting.com.au

Australian Branches
New South Wales South Australia
Sydney Adelaide
43 Newton Road 1 Graham Street
Wetherill Park NSW 2164 Export Park SA 5950
Tel: 1300 13 99 65 Tel: 1300 13 99 65
Sales Fax: 1300 13 99 53 Sales Fax: 1300 13 99 53
Project Fax: 1300 13 99 57 Project Fax: 1300 13 99 57

Northern Territory Victoria


Darwin Melbourne
Unit 3/132 Coonawarra Road 55 McGregors Drive
Winnellie N.T. 0820 Keilor Park VIC 3042
Tel: 1300 13 99 65 Tel: 1300 13 99 65
Sales Fax: 1300 13 99 53 Sales Fax: 1300 13 99 53
Project Fax: 1300 13 99 57 Project Fax: 1300 13 99 57

Western Australia Queensland


Perth Brisbane
2/32 Sarich Court 2/106 Fison Avenue West
Osborne Park WA 6017 Eagle Farm QLD 4009
Tel: 1300 13 99 65 Tel: 1300 13 99 65
Sales Fax: 1300 13 99 53 Sales Fax: 1300 13 99 53
Project Fax: 1300 13 99 57 Project Fax: 1300 13 99 57

Tasmania
Hobart
12 Fleet Street
Moonah TAS 7009
Tel: 1300 13 99 65
Sales Fax: 1300 13 99 53
Project Fax: 1300 13 99 57

Thorn Lighting is constantly developing and improving its products. All descriptions, illustrations, drawings and specifications in this publication present only general particulars and shall not form
part of any contract. The right is reserved to change specifications without prior notification or public announcement. All goods supplied by the company are supplied subject to the company’s
General Conditions of Sale, a copy of which is available on request. All measurements are in millimetres and weights in kilograms unless otherwise stated.

Publication Date: 10/2011

You might also like