Deviations During PWHT and Response
Deviations During PWHT and Response
Thermocouple Failure.
The ideal way to respond to a thermocouple failure is the use of a spare with its own
extension wire. It simply involves disconnecting the lead from the primary
thermocouple and connecting the lead for the spare thermocouple.
In the less likely event of a double failure (i.e., failure of both the primary and spare),
adjacent thermocouples may have to be used to estimate temperature. If access is
possible, a thermocouple located on the opposite surface from the point of double
failure provides a good source for such comparative data.