0% found this document useful (0 votes)
83 views2 pages

Hooded Tank Vent Kito BEH-4-IIA-... - A Kito BEH-5-IIA-... - A: Example To Order

Uploaded by

rob.carey
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
83 views2 pages

Hooded Tank Vent Kito BEH-4-IIA-... - A Kito BEH-5-IIA-... - A: Example To Order

Uploaded by

rob.carey
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

_________________________________________________________________________________________________________________________________________________

Hooded Tank Vent


KITO® BEH-4-IIA-...-A
KITO® BEH-5-IIA-...-A

Example to order :
®
KITO BEH-4-IIA-25-A
(design with flange connection DN 25)

Type examination certificate to DIN EN ISO 16852

-designation in accordance to ATEX-Guideline 94/9/EC

H weight * (kg)
DN ANSI G
BEH-4-IIA-…-A BEH-5-IIA-…-A BEH-4-IIA-…-A BEH-5-IIA-…-A
25 PN 40 1” 1” 195 205 7.5 9.5
32 PN 40 1 ¼“ 1 ¼“ 195 205 8 10
40 PN 40 1 ½“ 1 ½“ 196 210 8.5 10
50 PN 16 2“ 2“ 196 210 9 11
65 PN 16 2 ½“ 2 ½“ 197 220 9 13
80 PN 16 3“ 3“ 197 220 10 14
100 PN 16 4“ 4“ - 220 - 14.5
Dimensions in mm * weight refers to the standard design

Design subject to change for performance curves see diagram: B 0.1.1 N


Standard design Application
housing : steel, stainless steel mat. no. 1.4571 As breather/venting safety device incorporating an explosion and
KITO® flame arrester endurance burning flame arrester element for installation on top
element : completely interchangeable of storage tanks, tank access covers or breather lines. The
KITO® casing / grid : stainless steel mat. no. breather allows the unimpeded flow of gases out to atmosphere
1.4308 / 1.4310, 1.4408 / 1.4571 and air into the tank/pipe thereby preventing vacuum locks whilst
weather hood : PMMA ensuring provision of a permanent and reliable protection
protective screen : PA6 against any flashback into the tank/pipe.
flange connection : DIN EN 1092-1 form B1, This device is not permitted to be installed in enclosed areas.
threaded format, ANSI 150 lbs. RF Approved for all materials of the explosion group IIA with a
maximum experimental safe gap (MESG) > 0.9.
_________________________________________________________________________________________________________________________________________________

B 1.1 N
05.13
________________________________________________________________________________________________________________________________________________

Hooded Tank Vent


KITO® BEH-4-IIA-...-A
KITO® BEH-5-IIA-...-A
B 1.1 N
________________________________________________________________________________________________________________________________________________
Flow capacity V based on air of a density ρ = 1.29 kg/m³ at T = 273 K and atmospheric pressure p = 1.013 mbar.
For other gases the flow can be approximately calculated by
. . . .
ρb
V = Vb⋅ 1.29
or Vb = V ⋅ 1.29
ρb
KITO BEH-4-IIA-…-A
®
KITO BEH-5-IIA-…-A
®

Design subject to change

__________________________________________________________________________________________________________________________________________________

B 0.1.1 N