Set Up T&R Safe Position Encoder: 27.05.2013 Hrahn

The document provides instructions for setting up a T&R Safe Position Encoder that is installed at the turret drive gearbox on the drive side of a Jagenberg winder machine. It describes connecting the encoder, assigning its Profinet device name, setting encoder parameters in the S7-HW configuration software, adjusting the encoder's destination address via dip switches, and presetting the encoder position using the machine HMI when the turret is locked and the relevant winder is in the winding position.

Uploaded by

OSAMA
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
56 views

Set Up T&R Safe Position Encoder: 27.05.2013 Hrahn

The document provides instructions for setting up a T&R Safe Position Encoder that is installed at the turret drive gearbox on the drive side of a Jagenberg winder machine. It describes connecting the encoder, assigning its Profinet device name, setting encoder parameters in the S7-HW configuration software, adjusting the encoder's destination address via dip switches, and presetting the encoder position using the machine HMI when the turret is locked and the relevant winder is in the winding position.

Uploaded by

OSAMA
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 10

JAGENBERG-GRUPPE

27.05.2013 HRahn

Set Up T&R Safe Position Encoder


Encoder is Installed at Turret Drive Gearbox on Drive Side

The Profinet Device Name will be assigned at first download of the HW-Config.
Once the Hardware is loaded to the S7-CPU and a new encoder is connected, e.g. in case of
installing a spare encoder, the device name will be assigned automatically.

Seite 1 von 10
JAGENBERG-GRUPPE

Note: This is only working if Profinet-Topology is set (Standard at Imperial Winder).


If not the device name must be assigned manually.

Seite 2 von 10
JAGENBERG-GRUPPE

For Parameter Setting open S7-HW-Config.


To check/set the parameters Slot 1 and 2 must be opened with a double click.

Select the Tab “Profisafe”. The here shown Parameters are valid for Imperial Winders.

Seite 3 von 10
JAGENBERG-GRUPPE

The Destination Adress must be adjusted at the encoder by using the two DIP-Switches

Seite 4 von 10
JAGENBERG-GRUPPE

Drive Side in Machine Running Direction Right

Drive Side in Machine Running Direction Left

The setting becomes active after a Power Off/ON

Seite 5 von 10
JAGENBERG-GRUPPE

The Parameters at Slot 3 are “not safe” Parameters

Drive Side in Machine Running Direction Right

Drive Side in Machine Running Direction Left

Seite 6 von 10
JAGENBERG-GRUPPE
The Preset is to be done via the HMI HW Preset Page.

To access HW-Screen User „Maintenance“ must be selected

Seite 7 von 10
JAGENBERG-GRUPPE

To Preset Service Mode must be activated. Therefore the Key switch in Main Desk +CD
must be turned to “ON” Position.

Emergency Stop must not be active and all Drives must be switched Off

When Service Mode is active it is Shown on Main Screen in “Operation Mode” Field

To Preset the Turret Disc must be locked.

It doesn’t matter whether Winder A or B is in Winding Position.

Seite 8 von 10
JAGENBERG-GRUPPE

To check whether Turret disc is in Locking Position a calibartion point is defined on turret
disc Drive Side

To be checked e.g. with a ruler or semilar

Seite 9 von 10
JAGENBERG-GRUPPE

To Preset the Softbutton “Preset” must be pushed for 3s.

When Winder A is in Winding Position 0 Degree must be displayed as actual Position.