Set Up T&R Safe Position Encoder: 27.05.2013 Hrahn
Set Up T&R Safe Position Encoder: 27.05.2013 Hrahn
27.05.2013 HRahn
The Profinet Device Name will be assigned at first download of the HW-Config.
Once the Hardware is loaded to the S7-CPU and a new encoder is connected, e.g. in case of
installing a spare encoder, the device name will be assigned automatically.
Seite 1 von 10
JAGENBERG-GRUPPE
Seite 2 von 10
JAGENBERG-GRUPPE
Select the Tab “Profisafe”. The here shown Parameters are valid for Imperial Winders.
Seite 3 von 10
JAGENBERG-GRUPPE
The Destination Adress must be adjusted at the encoder by using the two DIP-Switches
Seite 4 von 10
JAGENBERG-GRUPPE
Seite 5 von 10
JAGENBERG-GRUPPE
Seite 6 von 10
JAGENBERG-GRUPPE
The Preset is to be done via the HMI HW Preset Page.
Seite 7 von 10
JAGENBERG-GRUPPE
To Preset Service Mode must be activated. Therefore the Key switch in Main Desk +CD
must be turned to “ON” Position.
Emergency Stop must not be active and all Drives must be switched Off
When Service Mode is active it is Shown on Main Screen in “Operation Mode” Field
Seite 8 von 10
JAGENBERG-GRUPPE
To check whether Turret disc is in Locking Position a calibartion point is defined on turret
disc Drive Side
Seite 9 von 10
JAGENBERG-GRUPPE
Seite 10 von 10