The document describes the different output modes of an ultrasonic sensor module: Mode 1 is the default mode and outputs a high signal from the ECHO port to indicate detection of an echo, with the pulse width proportional to the distance measured. Modes 2 and 3 operate in serial output mode, periodically transmitting or transmitting upon request the distance measured in millimeters.

Uploaded by

Bima Bryan Adam
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
52 views

JSN-SR04T Output Mode: The Default Working Mode Is Mode 1

The document describes the different output modes of an ultrasonic sensor module: Mode 1 is the default mode and outputs a high signal from the ECHO port to indicate detection of an echo, with the pulse width proportional to the distance measured. Modes 2 and 3 operate in serial output mode, periodically transmitting or transmitting upon request the distance measured in millimeters.

Uploaded by

Bima Bryan Adam
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

JSN-SR04T Output Mode

The default working mode is Mode 1.

Mode 1: R27 = open (no welding). The pattern is described below

Basic working principle:

• Using IO port TRIG trigger range, to a minimum of 10us high letter.

• Module automatically send 8 40khz square wave, automatically detect whether


the signal back;

• There is a signal to return, through the IO port ECHO output a high level, the
high level of continuous time is the ultrasound
• From the time of launch to return. Test distance = (high time * sound velocity
(340M / s)) / 2;

• When the module is triggered, if no echo is received (the reason is more than
the measured range or the probe is not positive On the measured object),

• ECHO port will automatically become low after 60MS, marking the end of the
measurement, regardless Power or not.

• LED indicator, LED non-power indicator, it will receive the trigger signal after the
module, this When the module is in working condition.

• Only need to provide a pulse above 10uS trigger signal, the module will be
issued within 8 40kHz cycle levels and detect echo. The echo signal is output
once an echo signal is detected. Reverberations

• The pulse width of the pulse is proportional to the measured distance. Thereby
by transmitting a signal to the received echo signal time interval

• Can calculate the distance. Formula: uS / 58 = cm or uS / 148 = inches; or:


distance = high time *Sound speed (340M / S) / 2;

• The recommended measurement period is 60ms or more to prevent the impact


of the transmitted signal on the echo signal.

Mode 2: R27 = 47K is the welding 47K resistance. The pattern is


described below
Serial output format for the TTL level, that: 100MS module for the cycle of automatic
transmission

The value of the distance, in mm. Serial baud rate: 9600, n, 8,1.

Module power recognition, directly into the work mode, the module to conduct a
distance every 100ms range,

And outputs one frame from the pin TX with four 8-bit data. The frame format is: 0XFF
+ H_DATA + L_DATA + SUM

1. 0XFF: for a frame to start the data, used to judge;

2. H_DATA: the upper 8 bits of the distance data;

3. L_DATA: the lower 8 bits of the distance data;


4. SUM: data and, for the effect of its 0XFF + H_DATA + L_DATA = SUM (only low 8)

Note: H_DATA and L_DATA synthesize 16-bit data, that is, the distance in millimeters.

Description: The module outputs the nearest distance value in the dead zone. If the
module does not measure data or is out of range Measured output 0.

LED indicator, LED non-power indicator, the module connected to work after the light,
then the module is in Working state.

Mode 3: R27 = 120K is the welding 120K resistance. In the serial port
mode
Module power recognition, the module into the standby state, the serial output
format for the TTL level, the serial port baud rate:

9600, n, 8, 1. When the RX port receives the 0X55 instruction, the module starts a
ranging and outputs from the pin TXOut of a frame with 4 8-bit data.

The frame format is: 0XFF + H_DATA + L_DATA + SUM

1. 0XFF: for a frame to start the data, used to judge;

2. H_DATA: the upper 8 bits of the distance data;

3. L_DATA: the lower 8 bits of the distance data;

4. SUM: data and, for the effect of its 0XFF + H_DATA + L_DATA = SUM (only low 8)

Note: H_DATA and L_DATA synthesize 16-bit data, that is, the distance in millimeters

Description: The module outputs the nearest distance value in the dead zone. If the
module does not measure data or is out of range Measured output 0.

LED indicator, LED non-power indicator, it will receive the 0X55 trigger signal in the
module, this When the module is in working condition.