Troubleshoot of DM Net
Troubleshoot of DM Net
Go to Top
Treated quality not upto the a. Cation exhausted Check
standard
b. Anion exhausted Check
d. MB resin not in uniform mixed state Repeat air mix and rinse
Chec
e. Some valves like backwash leaking k
f. Na slip from cation high Check raw water analysis; change in Na/TA
and SiO2/TA ratio; use more chemicals
Check
i. Unit not sufficiently rinsed Adjust to between unit min/max flow rate
m. Resin deteriorated
Mixed bed quality not good a. Resin not separated during backwash properly Give extended backwash after exhausting
the bed
b. Improper air flow to the degasser Check damper, speed of blower, discharge
pressure
d. Air seal not fitted/broken resulting in short Check and replace fitting
circulating of air
Unit rinse takes long time a. Flow rate too high Increase flow rate
e. MB air mix not satisfactory Carry out air mix once again
Flow rate too less a. Choked valve and suction strainer of pump Check
Pressure drop across the a. Defective valves Check
bed increasing day by day
b. Packed resin bed and resin fines present Give extended backwash with open
manhole and scrap off fines from top
surface of the resin
Flooding in degasser a. Very high air flow rate Reduce air flow rate by adjusting damper
Resin being lost a. Excessive backwash pressure Check inlet pressure and reduce if
necessary
Ejector not working a. Low power water pressure Check
e. Too much back pressure from the unit Check for chokage of collecting system;
passage of inlet/outlet valves
Incorrect reading rota- a. Chocked orifice lines/orifice Check and clean
meters
b. Dirty glass and float check and clean
Improper reading from flow a. Choked impulse lines/orifice Check and clean
recorder integrator
b. DP transmitter requires recalibration Recalibrate
Leakage from acid a. Improper adjustment of the mechanical seal Check and adjust
injection/unloading/transfe
r pumps b. Low strength of sulphuric and presence of Check concentration and take appropriate
ferrous sulphate action
Corrosion in concentrated a. Low concentration of sulphuric acid Check silica gel breather in acid storage
acid tanks and lines tank and replace silica gel charge if
exhausted
Improper opening and a. Defective solenoid valves Check
closing of pneumatically
operated valves b. Leakage in airline from solenoid valve to the Check
respective control valve.
Check
c. Improper contact of micro switch giving false
indication to panel Check
Improper operation of a a. Defective relays in the control circuit Check and replace relays
certain regeneration cycle
Solid state programme not a. The controller can be kept in "hold" due to the Remove conditions which cause "hold" of
functioning properly reasons explained under operation controller
b. Improper operation of the controls for the Press test switch & check the complete
controller cycle
c. Defect in the inside of the controller Check the instruments thoroughly from
inside. Meanwhile, operation may be
continued by using bypass toggle switches