Example:
Consider the expected temperature of the engineering laboratory to
be maintained is 25°C. The mechanical engineering student measured the
temperature with three trials as shown below:
T1=24.8°C
T2=25.1°C
T3=24.9°C
The values are closer to each other and they are closer to accepted value
25°C. Thus, this measurement can be said both accurate and precise.
Example:
Consider the expected temperature of the engineering laboratory to
be maintained is 25°C. The mechanical engineering student measured the
temperature with three trials as shown below:
T1=24.2°C
T2=25.5°C
T3=24.0°C
ME 154: INSTRUMENTATION & CONTROL ENGINEERING
The values are not closer to each other but they are closer to accepted
value 25°C. Thus, this measurement can be said accurate and but not precise.
Example:
Consider the expected temperature of the engineering laboratory to
be maintained is 25°C. The mechanical engineering student measured the
temperature with three trials as shown below:
T1=20.1°C
T2=20.2°C
T3=19.9°C
The values are closer to each other but they are not closer to accepted
value 25°C. Thus, this measurement can be said precise and but not accurate.