Acceptable Criteria API RP 2X Level C Acceptable Criteria API RP 2X Level C

The document provides acceptable criteria for API RP 2X Level C inspection of individual and accumulative reflectors in pipe, including minimum length, width/height, full screen height (FSH) amplitude comparison, and cursor sizing on S-Scan images. Reflectors below 40% FSH over 6 times the wall thickness are considered rejects. Clusters above 40% time-corrected gain that are over 2 times the wall thickness are evaluated using the tables provided.
Copyright
© © All Rights Reserved
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
100% found this document useful (5 votes)
2K views

Acceptable Criteria API RP 2X Level C Acceptable Criteria API RP 2X Level C

The document provides acceptable criteria for API RP 2X Level C inspection of individual and accumulative reflectors in pipe, including minimum length, width/height, full screen height (FSH) amplitude comparison, and cursor sizing on S-Scan images. Reflectors below 40% FSH over 6 times the wall thickness are considered rejects. Clusters above 40% time-corrected gain that are over 2 times the wall thickness are evaluated using the tables provided.
Copyright
© © All Rights Reserved
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 1

Acceptable Criteria API RP 2X Level C Acceptable Criteria API RP 2X Level C

Individual Reflector Individual Reflector

Amplitude Comparison
Length Width/Height FSH Length Width/Height Cursor Sizing S-Scan

8.2mm 6.4mm 400% 8.2mm 6.4mm Blue to Red

29.0mm 3.2mm 200% 29.0mm 3.2mm Blue to Red

105.2mm 1.6mm 65% - 99% 105.2mm 1.6mm Blue to Red

Accumulative Reflector Accumulative Reflector


Amplitude
Length Width/Height Comparison Length Width/Height Cursor Sizing S-Scan
FSH

19.9mm 6.5mm 400% 19.9mm 6.5mm Blue to Red

54.4mm 3.3mm 200% 54.4mm 3.3mm Blue to Red

152.4mm 1.7mm 65% - 99% 152.4mm 1.7mm Blue to Red

Note
- Indikasi di bawah Disregard Level (dibawah 40%FSH), tapi panjangnya 6xWT (contoh 6x25WT=150mm/6x60WT=360mm) termasuk
dalam indikasi Reject

- Cluster
Reflector (Contoh Cluster Porosity) yang Responnya diatas 40% TCG dan juga panjangnya 2xWT (contoh
2x25WT=50mm/2x60WT=120mm) Evaluasi menggunakan table diatas