100% found this document useful (2 votes)
4K views

UT ASME Report Format

An ultrasonic testing report was prepared for a client documenting inspection of a flange cladding at an industrial site in Dammam, Saudi Arabia. No recordable indications were observed during the inspection. Test equipment including normal and angle beam probes were used to inspect the flange. Details of the flange such as part number, serial number and specifications are documented. The report was signed off by the inspector and Level II technician.

Uploaded by

rifa
Copyright
© © All Rights Reserved
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
100% found this document useful (2 votes)
4K views

UT ASME Report Format

An ultrasonic testing report was prepared for a client documenting inspection of a flange cladding at an industrial site in Dammam, Saudi Arabia. No recordable indications were observed during the inspection. Test equipment including normal and angle beam probes were used to inspect the flange. Details of the flange such as part number, serial number and specifications are documented. The report was signed off by the inspector and Level II technician.

Uploaded by

rifa
Copyright
© © All Rights Reserved
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 2

INSPECTION QUALITY CONTRACTING EST.

ULTRASONIC TESTING REPORT


CLIENT IQ JOB NO. SHEET 01 OF 02
SASIB ……

SITE/LOCATION PROCEDURE& EQUIPMENT TYPE EQUIPMENT SERIAL NO.


INDUSTRIAL CITY, DAMMAM REVISION:- N/A USM 36 15077586
PO/REQUEST NO. ACCEPTANCE CALIBRATION COUPLANT
IQ/NDT/SOP-01, REV 01 CRITERIA BLOCK ULTRASONIC ECHO JEL
N/A ASME 38 & 75 MM
LINE/DWG/COMPONENT WELD TYPE & REF. BLOCK REF. REFLECTOR
THICKNESS: -
X-273085-01 VARIOUS V1 BLOCK V2 BLOCK
MATERIAL TYPE & THICKNESS WELD SURFACE REF.BLOCKSERIAL REFLECTOR DEPTH
……. COND. NO.
CLADING …….. SDH 3 mm, SDH 5mm
ITEM DESCRIPTION CABLE TYPE AND REJECT SETTING TRANSFER CORRECTION
LENGTH:
FLANGE LIMI TO MINI LIMO 2 OFF N/A
mtr
DAC Settings
Reflector Reflector Reflector
PROBE % Echo Beam path % Echo Beam path % Echo Beam path
No. No. No.
2nd ECHO
0° 1 80 100 80% FSH ON ……. …….. ……. …….. …….
JOB

45° 1 80 19 2 41 38 3 20 59

60° …… …… …… …… …… …… …… …… ……

70°

PROBE DETAILS

RANG PRIMARY
TYPE SIZE SERIAL ANGLE FREQ (MHz) SCAN GAIN REF AMP.
E GAIN
NORMAL 10 MM
PROBE DIA
72332 0 DEG 2 MHz 200 72 dB +10 dB 2ND ECHO 80% FSH

GE 10 MM 37029 45° 2 MHz 300 59 dB +10dB 80% FSH

Result: -

Accessible are ultrasonic Testing carried out on flange cladding checked. At inspection time
no recordable indication was observed.

Flange details :- 9984-1-2, PN:140162-01-70-09, SN: 4512309833-10-191


ACC REJ
Acc

FOR IQ FOR THIRD PARTY /AS APPLICABLE FOR CLIENT


SIGNED SIGNED SIGNED

NAME:- Laxman ban NAME NAME


LEVEL II DATE TITLE DATE TITLE DATE
05-03-2020

ULTRASONIC EXAMINATION REPORT


(CONTINUATION SHEET)

WELD SIZE / WT / WELDE


R ID
IDENTIFICATION INTERPRETATION RESULT
NO. DIA SCH
INSPECTION QUALITY CONTRACTING EST.

FOR IQ FOR THIRD PARTY /AS APPLICABLE FOR CLIENT


SIGNED SIGNED SIGNED

NAME NAME NAME


LEVEL II DATE TITLE DATE TITLE DATE