Design of Pilecap (Under Reamed)

This document provides design details for a pile cap supporting 3 piles with a diameter of 500mm each. The key parameters and design checks included are: - Grade of concrete and steel - Pile diameter, cap dimensions, and applied loads - Bending moment and required reinforcement area and spacing - Check for minimum required depth and actual effective depth provided - Punching shear capacity and required shear reinforcement It includes notes on ensuring the depth accommodates the column bar diameter and meets the minimum depth requirement of 1.5 times the pile diameter. Stirrup spacing and diameter are selected to provide the necessary shear reinforcement.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
273 views10 pages

Design of Pilecap (Under Reamed)

This document provides design details for a pile cap supporting 3 piles with a diameter of 500mm each. The key parameters and design checks included are: - Grade of concrete and steel - Pile diameter, cap dimensions, and applied loads - Bending moment and required reinforcement area and spacing - Check for minimum required depth and actual effective depth provided - Punching shear capacity and required shear reinforcement It includes notes on ensuring the depth accommodates the column bar diameter and meets the minimum depth requirement of 1.5 times the pile diameter. Stirrup spacing and diameter are selected to provide the necessary shear reinforcement.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 10

PILE CAP DESIGN(1 PILE): P600

Grade of concrete = 25 N/mm2


Grade of steel = 500 N/mm2
Diameter of pile = 500 mm
Length of beam = 0.8 m
Breadth of beam = 0.8 m
Load from column(W) = 800 kN
Selfweight of pile cap = 40 kN
Total load = 840 kN
B.M. on beam(M) = 336 kNm
d = 348.91 mm
Clear Cover = 60 mm
Dia of bar used 16 mm
Overall depth = 432.91 mm
Min. required depth of pile cap = 750.00 mm
Overall depth provided (D) = 800 mm *NOTE: Depth should b
Actual effective depth(d) = 716 mm
Mu/bd2 = 0.82
pt(from table 4 of SP16) = 0.12 %
Ast = 1145.6 mm2
No. of bars = 5.70
No. of bars provided = 10.00 spacing
Distribution R/F = 401.92 mm2
No. of bars provided = 10.00 spacing
Actual pt = 0.35 %
Check for punching shear:
Load/m = 1050.00 kN/m
Shear Force(Vu) = 630.000 kN
Tv = 1.10 N/mm2
Tc(from table 19 of IS456) = 0.365 N/mm2
Shear R/F required
Shear resistance of concrete = 209072.000 N
Net shear force for which shear R/F is necessary = 420928.000 N
Let stirrup bar dia = 16 mm
No. of legs of stirrup = 2
Area of 1 bar = 401.920 mm2
Spacing of stirrups = 297.395 mm
900x900x950
8-#20

*NOTE: Depth should be sufficient to accommodate 50xdia of col. bars


Min. depth to be 1.5 x pile dia

57.77778

57.77778
PILE CAP DESIGN(2 PILES): 2- P50

Grade of concrete = 25 N/mm2


Grade of steel = 500 N/mm2
Diameter of pile = 500 mm
Length of beam = 2.3 m
Breadth of beam = 0.8 m
Load from column(W) = 3000 kN
Selfweight of pile cap = 150 kN
Total load = 3150 kN
Distance between 2 piles = 1500 mm
B.M. on beam(M) = 1125 kNm
d req = 638.44 mm
Clear Cover = 60 mm
Dia of bar used 25 mm
Overall depth = 735.94 mm
Min. required depth of pile cap = 750.00 mm
Overall depth provided (D) = 1000.00 mm *NOTE: Depth should b
Actual effective depth(d) = 902.5 mm
Mu/bd2 = 1.73
pt(from table 4 of SP16) = 0.532 %
Ast = 3841.04 mm2
No. of bars = 7.83
No. of bars provided = 8.00 spacing
Distribution R/F = 785.00 mm2
No. of bars = 16.00 spacing
Actual pt = 0.54 %
Check for punching shear:
Load/m = 1369.57 kN/m
Shear Force(Vu) = 2362.500 kN
Tv = 3.27 N/mm2
Tc(from table 19 of IS456) = 0.370 N/mm2
Shear R/F required
Shear resistance of concrete = 267140.000 N
Net shear force for which shear R/F is necessary = 2095360.000 N
Let stirrup bar dia = 20 mm
No. of legs of stirrup = 2
Area of 1 bar = 628.000 mm2
Spacing of stirrups = 117.662 mm
-Values to be entered

2300x800x1000
8-#25
16-#25

*NOTE: Depth should be sufficient to accommodate 50xdia of col. bars


Min. depth to be 1.5 x pile dia

70.916289474588 mm

118.66666666667 mm
PILE CAP DESIGN(2 PILES): 2- P70

Grade of concrete = 25 N/mm2


Grade of steel = 415 N/mm2
Diameter of pile = 700 mm
Length of beam = 3.1 m
Breadth of beam = 1 m
Load from column(W) = 5000 kN
Selfweight of pile cap = 250 kN
Total load = 5250 kN
Distance between 2 piles = 2100 mm
B.M. on beam(M) = 2625 kNm
d req = 872.28 mm
Clear Cover = 60 mm
Dia of bar used 32 mm
Overall depth = 980.28 mm
Min. required depth of pile cap = 1050.00 mm
Overall depth provided (D) = 1400.00 mm *NOTE: Depth should b
Actual effective depth(d) = 1292 mm
Mu/bd2 = 1.57
pt(from table 4 of SP16) = 0.467 %
Ast = 6033.64 mm2
No. of bars = 7.51
No. of bars provided = 8.00 spacing
Distribution R/F = 1286.14 mm2
No. of bars = 16.00 spacing
Actual pt = 0.50 %
Check for punching shear:
Load/m = 1693.55 kN/m
Shear Force(Vu) = 3937.500 kN
Tv = 3.05 N/mm2
Tc(from table 19 of IS456) = 0.370 N/mm2
Shear R/F required
Shear resistance of concrete = 478040.000 N
Net shear force for which shear R/F is necessary = 3459460.000 N
Let stirrup bar dia = 12 mm
No. of legs of stirrup = 2
Area of 1 bar = 226.080 mm2
Spacing of stirrups = 30.485 mm
-Values to be entered

3100x1000x950
8-#32
16-#32

*NOTE: Depth should be sufficient to accommodate 50xdia of col. bars


Min. depth to be 1.5 x pile dia

98.340800795442 mm

164.53333333333 mm
PILE CAP DESIGN(3-PILES): 3-p60

Grade of steel = 415.000 N/mm2


Load on pile = 670.000 kN
Reaction at A, B & C = 223.333 kN
Reaction at D = 446.667 kN
Dia of pile = 500.000 mm
c/c distance between piles = 1500.000 mm
Length of beam DC = 2099.038 mm
Length of beamAB = 1500.000
Width of beam DC = 800.000 mm
Min. required depth of pile cap = 750.000 mm
Let depth of beam DC = 1300.000 mm *NOTE: Depth should be su
Selfweight of beam DC = 54.57 kN/m
BM at G due to selfweight = 60.114 kNm
BM due to col. Load on beam DC = 193.412 kNm
Total BM = 253.526 kNm
BM due to col. Load on beam AB = 335.000 kNm
BM due to selfweight = 15.349 kNm
BM due to self weight transferred by beam DC to beam AB = 60.114 kNm
Total BM on beam AB = 410.463 kNm
Factored BM = 615.695 kNm
Clear cover = 60.000 mm
Dia of bar used = 16.000 mm
Effective depth = 1232.000 mm
Design of beam DC:
Mu/bd2 = 0.209
pt from table 4 of SP16 = 0.084 %
Ast = 827.90 mm2
No. of bars = 4.12
No. of bars provided = 5.00 spacing
Distribution Reinforcement = 200.96 mm2
No. of bars provided = 7.00 mm2 spacing
Actual pt = 0.102 %
Design of beam AB:
Mu/bd2 = 0.338
pt from table 4 of SP16 = 0.099 %
Ast = 975.744
No. of bars = 4.86
No. of bars provided = 5.00 mm2
Distribution Reinforcement = 1.000 mm2
Check for punching shear:
Load/m = 54.89 kN/m
Shear Force(Vu) = 86.419 kN
Tv = 0.09 N/mm2
Tc(from table 19 of IS456) = 0.400 N/mm2
Provide min. shear R/F
Shear resistance of concrete = 394240.000 N
Let stirrup bar dia = 16 mm
No. of legs of stirrup = 2
Area of 1 bar = 401.920 mm2
Spacing of stirrup = 453.479 mm
Provide Ф12@200mm c/c
A D
*NOTE: Depth should be sufficient to accommodate 50xdia of col. bars
Min. depth to be 1.5 x pile dia

150 mm

325.8397 mm
D B