0% found this document useful (0 votes)
735 views4 pages

POSTEF - ZXDU68 B301 (V5.0R07M02) Embedded DC Power System PDF

The ZXDU68 B301 is a 6U height, 19-inch width embedded DC power system that provides -48V power to communication equipment. It uses six ZXD3000 rectifier modules to provide a maximum output current of 300A. The system has a wide input voltage range of 70V to 300V AC, high efficiency of up to 96.3%, and can be remotely managed through a web browser over Ethernet.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
735 views4 pages

POSTEF - ZXDU68 B301 (V5.0R07M02) Embedded DC Power System PDF

The ZXDU68 B301 is a 6U height, 19-inch width embedded DC power system that provides -48V power to communication equipment. It uses six ZXD3000 rectifier modules to provide a maximum output current of 300A. The system has a wide input voltage range of 70V to 300V AC, high efficiency of up to 96.3%, and can be remotely managed through a web browser over Ethernet.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

ZXDU68 B301

Embedded DC Power System

1
Overview
The ZXDU68 B301 system is a 6U height, 19-inch width embedded DC power system.
The system can provide power to -48 V series communication equipment. When fully
configured, the system is equipped with six ZXD3000 rectifiers and can provide a rated output
current of 300A.

ZXDU68 B301 (V5.0R07M02) DC power system

Highlights
 High efficiency module with peak efficiency up to 96.3%, in the sleep mode, the output
power of the rectifier is lower than 4W.
 70V AC~300V AC wide input voltage, high adaptive to poor grid to protect battery.
 The system can be remotely managed through a computer installed with Web explorer
anywhere if Ethernet is available.
 Managing Data in Batches Users can set the parameters in batches, copy records and
upgrade programs via a USB disk.
 QUY shortcuts of rectifier, convenient to fast query and fault location.
 Provide dry contact, RJ45, RS232, RS485, USB interface.
 Positive / negative busbar bar is designed with thickness and cross section suitable for
maximum capacity of DC power system, pure red copper busbar with coating of
antioxidant material (tin / nickel)

Technical Specification

2
Parameters Description
Model Type ZXDU68 B301 (V5.0 R07M02)
Rectifier module ZXD3000 (V5.5), 5 x 3000W maximum
Monitoring unit CSU501B 29
AC input
Input type 1phase (L/N/PE) , Three-phase five-wire (L1/L2/L3/N/PE)
70V AC ~ 300V AC (able to work in short time within input voltage
Input voltage range
range 300-350V)
Frequency 45Hz~66Hz
Input power factor ≥0.99 (50%~100% load)
Imax=40 kA
AC SPD
MOV technology
DC output
Output voltage -53.5 V (-41.5V ~ -58.5V adjustable)
Output power 15kW (with rated load)
Output current ≥ 300 ADC
≥95.5% (peak efficiency)
System efficiency
≥95% (at rated load)
LLVD1+ BLVD; 200A;
Load distribution
CB: 02 x 63A, 03 x 50A, 05 x 16A
Battery distribution 3 × 100 A MCBs
DC SPD MOV technology
Operation environment
Operation temperature -40℃~+65℃,
Storage temperature -40℃~+85℃
Humidity 10% ~ 95%
0 to 3000 m: 100% output power;
Altitude above 3000 m: The power derating percentage is 1% when the altitude
increases by 100 m.
Structure
Dimension 6U ×19 inches× 360 mm (H × W × D)
Weight Chassis weight: ≤ 30 kg; Rectifier weight: 2 kg/set
Standard
Safety IEC60950; GB4943
EMC IEC61000
Environment & RoHS IEC60068-2-78:2001; EUROHS GENERAL 2011/65/EU
Others
MTBF ≥3.2 × 105 hours

You might also like