Layout Proposal CSD - 148 5613
Layout Proposal CSD - 148 5613
Drawings remain our exclusive property. They are entrusted only for the agreed purpose. Copies or any other reproduction, including storage, treatment and dissemination by use
Air exhaust fan Louver for outgoing air Louver for incoming air package/ ambient temperature
temperature controlled thermostatically controlled with thermostatically controlled with min.: + 3° C
of electronic systems must not be made for any other than the agreed purpose. Neither originals nor reproductions may be given to or made available to third parties. A-A
with weather protection lattice weather protection lattice weather protection lattice max.: + 40° C
Air main
charging To the
system mains
Compressed
air line
Condensate Air
line receiver
4200
Air
3592
receiver
SAM
Filter
2000
1900
Adsorption
Refrigeration
Filter Extra Screw Screw Screw
dryer
compressor compressor compressor
7200 2 3 7 9 10
5 To the
800 1230 1000 1230 1340 O 1400 200 mains
A 6
sonstige Vervielfältigungen einschließlich Speicherung, Verarbeitung oder Verbreitung unter Verwendung elektronischer Systeme dürfen nur zu dem vereinbarten Zweck angefertigt
1
Die Zeichnung bleibt unser ausschließliches Eigentum. Sie wird nur zu dem vereinbarten Zweck anvertraut und darf zu keinem anderen Zweck verwendet werden. Kopien oder
8
Refrigeration dryer
Refrigeration dryer
3 7
Condensate 2
1400
Legend
treatment system 5
Filter AQUAMAT 1 Screw compressor
2 Hose line
Adsorption 4
6
3 Ball valve
Air main 1 4 Recommendation: Electronic condensate drain
Filter Extra charging 5 Refrigeration dryer
werden. Weder Original noch Vervielfältigungen dürfen Dritten ausgehändigt oder in sonstiger Weise zugänglich gemacht werden.
Drawings remain our exclusive property. They are entrusted only for the agreed purpose. Copies or any other reproduction, including storage, treatment and dissemination by use
Com- Incoming duct dimen- Compressed Com- Incoming Com- Com- Com- Com-
Working aperture free overall pressure trap Refrigera- aperture (free (thermostatically ECO- Air Air main treatment
Compressor pressed air volume sions (free air collective pressed air volume Filter pressed Filter pressed pressed pressed
of electronic systems must not be made for any other than the agreed purpose. Neither originals nor reproductions may be given to or made available to third parties.
pressure cross section loss for exhaust ECO- tion dryer cross section) controlled) DRAIN receiver Control charging unit
model air con- per unit cross section) line air con- per unit Extra air con- Adsorption air con- air con- air con-
per unit duct per unit DRAIN model per unit per dryer a) system AQUAMAT
nection per unit (two units) nection nection nection nection nection
a) a)
[bar(g)] [m²] [m³/h] [m²] ∆p [Pa] [m²] [m³/h] [m³/h] [l]
CSD 85 8.5 G2 1.2 9890 0.64 80 DN 80 32 TE 142 G2 0.4 3040 3040 F 83 KE G2 31 F F 83 KA G2 3000 G 2 1/2 SAM 4.0 DHS 80 DN 80 CF 38
CSD 105 8.5 G2 1.4 10010 0.64 80 DN 80 32 TF 174 DN 65 0.8 7800 7800 F 110 KE G2 31 F F 110 KA G2 5000 DN 100 SAM 4.0 DHS 80 DN 80 CF 38
CSD 125 8.5 G2 1.8 11420 0.64 60 DN 80 32 TF 230 DN 80 0.8 7800 7800 F 142 KE G2 31 F F 142 KA G2 5000 DN 100 SAM 4.0 DHS 80 DN 80 CF 75
Design limits for
ambient temperature
min.: + 3° C
max.: + 40° C
------------------
a) Climatic zone 2
sonstige Vervielfältigungen einschließlich Speicherung, Verarbeitung oder Verbreitung unter Verwendung elektronischer Systeme dürfen nur zu dem vereinbarten Zweck angefertigt
Die Zeichnung bleibt unser ausschließliches Eigentum. Sie wird nur zu dem vereinbarten Zweck anvertraut und darf zu keinem anderen Zweck verwendet werden. Kopien oder
werden. Weder Original noch Vervielfältigungen dürfen Dritten ausgehändigt oder in sonstiger Weise zugänglich gemacht werden.
Not to scale
This drawing also contains work to be done on site. The regulations of EN 1012 and national regulations for setting up of
power installations like VDE 0100 have to be observed; the requirements of existing operational safety ordinance and the
manuals have to be considered by the operator and the employer respectively at the place of installation.
The national safety and accident prevention regulations have to be observed.
The installation of a sub- assembly in terms of the pressure equipment directive 2014/ 68/ EU has to be carried out
according to this directive.
P+I Scale Date Name
X
Inst.
1:50 Drawn 19/09/2016 Nahhas1
Template Rev. 17.07.2013 X DIN A3 Checked 19/09/2016 Hobusch
ATTENTION!
collecting line via swan neck or are to be fed
to the condensate treatment system separately.
2x CSD with exhaust air duct LYMU0007201e
Minimum width of door is total component width + 100 mm A pressure-less drain has to be provided for. (Shown 2x CSD 125, 2x TF 230, 2x F 142 KE,KA) Page 2 of 2
We reserve the right to make changes in the course of developement. This drawing can only be modified with CAD