43100-EN (Web)
43100-EN (Web)
Presentation
PL7 Micro/Junior/Pro software is designed for Windows 2000, XP, Vista and 7 (all
32-bit) operating systems (1) and, therefore, benefits from all the facilities associated
with these operating systems.
Management of access rights, for limiting and controlling the use of the various
b
Terminal PC Terminal PC server mode from a third-party client application. In this case, certain functions of the
Client Server
PL7 software can be executed following commands sent by an OLE client application
Automation
Client PL7
Applications b
Enhancement of the application data export files (FEF), for better compatibility
OLE
OLE
Fipway
TSX Micro
Premium
Operation in application server mode
Functions
Four IEC languages
The four graphical or textual languages available in PL7 are used for programming
Modicon Premium and TSX Micro automation platforms.
For these 4 languages, you can use the standard set of instructions compliant with
IEC standard 61131-3 to create applications, which can be transferred from one
platform to another. PL7 software also provides extensions to this standard set of
instructions. As they are specific to Modicon Premium and TSX Micro PLCs, these
extensions support the development of more complex applications in order to
Grafcet SFC language graphic editor maximize the potential of the specific features of each of these platforms.
Facilitates program debugging (all variables handled by the DFB function block
b
of the application
DFB type editor (1) Compatibility with Windows 95, 98, Millenium and NT4.0 is no longer assured. For
information, Windows 95 and Windows NT 4.0 cannot manage USB ports.
2 43100-EN
version: 13.0
Functions (continued) Software 5
PL7 software
PL7 Micro/Junior/Pro
Functions (continued)
Debugging tools
PL7 Micro/Junior/Pro software offers a complete set of tools for debugging
applications. A tool palette provides direct access to the main functions:
Setting breakpoints
b
(EVTi) tasks
Other functions available are:
Animation of program elements when the PLC is in RUN
b
monitored or modified
Debugging of DFB function blocks via the animation tables
b
Animation table b
of Advanced Panel Magelis XBT G , Magelis iPC Panel PC/BOX PC with Vijeo
p
Cross-referencing of variables
For every variable, this function can be used to:
Search for program modules where this variable is used
b
Application converters
PL7 Micro/Junior/Pro software includes application converters which enable the
reusing of all or part of previous applications written in:
PL7 2, applications for TSX 17, TSX 27 or TSX 47 10/20/25 PLCs
b
Cross-referencing of variables
X-Way communication drivers
Uni-Telway COM port and USB port (PC side) communication drivers are available
on the PL7 software CD-ROM.
Depending on the user’s needs, other drivers may be necessary. In this case, please
consult our website www.schneider-electric.com and download the drivers available.
(1) Using PL7 software V4.0 extends the system diagnostics of the Premium platform. The
u
system bits and words can be monitored as well as automatic displaying of associated
time-stamped messages, without any additional programming. This monitoring is of the
system elements (processor, memory, tasks, etc.), “In rack” I/O and remote I/O on Fipio bus.
(2) Function or feature requiring PL7 Junior/Pro software.
References:
pages 43100/4 ...
43100-EN 3
version: 13.0
References Software 5
PL7 software
PL7 Micro/Junior/Pro
References
PL7 Micro/Junior/Pro are multi-language (English, French, German, Italian and Spanish) software packages
designed for PC compatibles (1) with Windows 2000, XP, Vista or 7 (all 32-bit) operating system.
For a station, the package comprises:
b
1 CD-ROM containing the multilingual PL7 software, PL7 demonstration applications and the Uni-Telway
v
Note: The operating systems of Modicon TSX Micro/Premium platforms are available on our website www.schneider-electric.com.
Cables for connection to the PC are to be ordered separately and depend on the desired number of users and
the type of link (RS 232 or USB port). See separate parts (page 43100/5).
(1) The configuration of the PC must correspond to the reference and version of the Windows operating system installed.
Note: The PC must have a CD-ROM drive.
Presentation:
page 43100/2
4 43100-EN
version: 13.0
References (continued) Software 5
PL7 software
PL7 Micro/Junior/Pro
References (continued)
PL7 Micro/Pro software licences
Description For PLCs Licence type Reference Weight
kg
PL7 Micro Open Team TSX Micro Team (10 stations) TLX OT PL7M P45M –
software licence (1)
PL7 Pro Open Team TSX Micro, Premium Team (10 stations) TLX OT PL7P P45M –
software licence (1)
PL7 Pro Open Site TSX Micro, Premium Site (>10 stations) TLX OS PL7P P45M –
software licence (1)
Separate parts
Description Description Reference Weight
kg
X-Way drivers package CD-ROM including X-Way drivers (see page 43100/3) TLX CD DRV20M –
for compatible PC Includes multilingual user documentation
Presentation:
page 43100/2
43100-EN 5
version: 13.0