RATs Report

1. The inspection report summarizes the condition of the Kithaganamane U.M Kere tank in Alur Taluk, Hassan District. 2. The key observations are that the tank bund and sluice are in good condition and meet M.I. standards. 3. Minor issues like establishing permanent marks to indicate the prescribed tank bund level and installing surplussing arrangements need to be addressed.

Uploaded by

sagar
Copyright
© © All Rights Reserved
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
43 views

RATs Report

1. The inspection report summarizes the condition of the Kithaganamane U.M Kere tank in Alur Taluk, Hassan District. 2. The key observations are that the tank bund and sluice are in good condition and meet M.I. standards. 3. Minor issues like establishing permanent marks to indicate the prescribed tank bund level and installing surplussing arrangements need to be addressed.

Uploaded by

sagar
Copyright
© © All Rights Reserved
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 26

PRE/POST MANSOON INSPECTION REPORT OF M.

I WORKS FOR THE YEAR 2016-17

1 District : Hassan
2 Taluk : Alur
3 Name of Tank : Hanthanamane Aralikatte
4 Date of Inspection : 9/8/2016
5 Date of Last test check by Asst. Executive : 2/7/2016
Engineer.
6 Observation : Good
7 Tank Bund:- :
a) Are there T.B.L Stones or other : No
paramanent marks to indicate the
prescribed TBL ?
b) Is the top of bund any where below the : No
prescribed level? (if so specify the length &
shortages)
c) Are the top width and slopes according to : This is an old tank which is not in par with M.I
M.I.S Tandards every where ? (If not standards
specify the lengths & extent of Difficincies)

d) Are there any dangerous gullies, cart track : No


ruts etc. which in your opinion, must be
repaired urgently (If so specify the
locations)
e) Action taken to rectify deficiencies notes : NA
in(a) to (d) above.
II) 1. SURPLUSING ARRANGEMENTS:- :
a) Are the surplussing arrangement at site in : Yes
order (If not indicate the variations).

b) Has the prescribed MWL been exceed : or : No


over flown to indicate that the surplusing
arrangement are in adequate or rendered
inoperative.
c) Is the draft channel capable of carrying the : Yes
designed discharge.
d) Any remidial maasures contemplated & : NA
action taken.
III) Sluice & Other masonry works:- :
a) Are they in good order so as to not effect : sluice head wall requires Reconstruction
the safety of the bund, condition of
controlling arrangements may be indicated.

b) Action taken to rectify any defect noticed. : Nill

IV) GENERAL:- :
a) Progress on works, if any already on hand : Nill
and the probable date of completionof the
same.
b) Any other special remarks of the Inapecting : 1. Under the Railway Track is to be Desilted
officer/official: and jungle has to be removed
2. Geauge pole to be errected in the tank to
watch danger level of the flood
Assistant Executive Engineer
N0.5, PRE Sub-Dvn, Alur
GUIDENCE FOR SUBMISSION OF DISTRESS REPORT OF INDIVIDUAL I.MI.TANKS.
WHICH ARE RAILWAY AFFECTING.
Performance Report:
GUIDE LINES.

1 Whether water has been over flown above : No


the bund of the(by local enquiry) duringany
of the monsoon till to-day.

2 Are/then any defects noticed in the waste : No


weir of sluice of any supportance of the
tank which may cause damage to the tank.

3 Wheather the level of the bund is below : Not Required


MWL as per M.I standards etc., with
adquate provision of (Free board) or
whether the bund height has to be raised to
render it safe.
4 Catchment to the tank good average or : Average
bad and also whether it has intercepted
catchment that may be ardous to the tank.

5 Any repairs suggested (To be supported by :


line estimates enclosed.)(if any). 1. Under the Railway Track is to be Desilted
and jungle has to be removed
2. Geauge pole to be errected in the tank to
watch danger level of the flood

Assistant Executive Engineer


N0.5, PRE Sub-Dvn, Alur

E/Kps/R.A.T Report.xls
DETAILS OF RAILWAY AFFECTING TANK IN
Name of District : HASSAN Name of Division : PRE HASSAN
Name of Railway line: Hassan - Sakaleshpura

1 Name of Tank : Hanthanamane Aralikatte

2 Owner shiip : Zilla Panchayat Hassan.

3 Village / Taluk : Hanthanamane / ALUR

4 Reference to sy.No. Stagement Map. : -

5 Between Railway Station. : Hassan to S.K.Pur Railway station C.No. 36

6 Approximate Location WRT Railway line. :

7 Catchment area in Sq miles/Sqm.Kms. : 0.02 sq kms


8 Maximum calculated suspens discharge in : 3.65 cumecs
acres/cumes.
9 Approximate Storage capacity in million : 2.00 Mcum
cubic mtrs.
10 Approximate area of water spred F.I.L in : 0.016 km2
Sq. miles/sq Kms.
11 F.T.L In Mtrs. : 98.55 Mtrs
12 M.W.L. In Mtrs. : 99.15 Mtrs
13 R.L.of Bund in mtrs. : 99.80 Mtrs
14 Top width in Mtrs. : 3.00 Mtrs
15 Side slopes of bund pitched & : Bund slope pitched 11/2 :2
16 Particulars of surpusing arrangements : Scopping aproxe
type/length.
17 Crest level of supusing in Mtrs. Length. : 98.99 Mtrs

18 Authority responsible for inspecting & : AEE P.R.E.Sub -Div. Alur& G.P Alur.
Maintance of tank.
19 Kms. Of Railway bridge bund effected. : Hassan to S.K.Pur Railway line c.No. 36
20 Bridge and span. :

21 R.L.of under side grader slab on spring of :


Only,

22 Railway level : 100.25 Mtrs.(assumed RC)

23 Maximum recorded H.F.L. : 99.15 Mtrs

24 Railway official responsible :

25 Previous instructions of any. :

26 Remarks. :
1. Under the Railway Track is to be Desilted
and jungle has to be removed
2. Geauge pole to be errected in the tank to
watch danger level of the flood
E/Kps/R.A.T Report.xls Assistant Executive Engineer
N0.5, PRE Sub-Dvn, Alur

PRE/POST MANSOON INSPECTION REPORT OF M.I WORKS FOR THE YEAR 2016-17

1 District : Hassan
2 Taluk : Alur
3 Name of Tank : Kithaganamane U.M Kere
4 Date of Inspection : 9/8/2016
5 Date of Last test check by Asst. Executive : 2/7/2016
Engineer.
6 Observation : Good
7 Tank Bund:- :
a) Are there T.B.L Stones or other : NIL
paramanent marks to indicate the
prescribed TBL ?
b) Is the top of bund any where below the : NIL
prescribed level? (if so specify the length &
shortages)
c) Are the top width and slopes according to : MI Standard
M.I.S Tandards every where ? (If not
specify the lengths & extent of Difficincies)

d) Are there any dangerous gullies, cart track : NIL


ruts etc. which in your opinion, must be
repaired urgently (If so specify the
locations)
e) Action taken to rectify deficiencies notes : -
in(a) to (d) above.
II) 1. SURPLUSING ARRANGEMENTS:- :
a) Are the surplussing arrangement at site in : NO
order (If not indicate the variations).

b) Has the prescribed MWL been exceed : or : NIL


over flown to indicate that the surplusing
arrangement are in adequate or rendered
inoperative.
c) Is the draft channel capable of carrying the : -
designed discharge.
d) Any remidial maasures contemplated & : NIL
action taken.
III) Sluice & Other masonry works:- :
a) Are they in good order so as to not effect : Good Condition
the safety of the bund, condition of
controlling arrangements may be indicated.

b) Action taken to rectify any defect noticed. :

IV) GENERAL:- :
a) Progress on works, if any already on hand :
and the probable date of completionof the
same.
b) Any other special remarks of the Inapecting :
officer/official: Bund Sluice and w/w good condition

E/Kps/R.A.T Report.xls

GUIDENCE FOR SUBMISSION OF DISTRESS REPORT OF INDIVIDUAL I.MI.TANKS.


WHICH ARE RAILWAY AFFECTING.
Performance Report:
GUIDE LINES.

1 Whether water has been over flown above : NIL


the bund of the(by local enquiry) duringany
of the monsoon till to-day.

2 Are/then any defects noticed in the waste : NIL


weir of sluice of any supportance of the
tank which may cause damage to the tank.

3 Wheather the level of the bund is below : NIL


MWL as per M.I standards etc., with
adquate provision of (Free board) or
whether the bund height has to be raised to
render it safe.
4 Catchment to the tank good average or : Average
bad and also whether it has intercepted
catchment that may be ardous to the tank.

5 Any repairs suggested (To be supported by :


line estimates enclosed.)(if any). Bund Sluice and w/w good condition

E/Kps/R.A.T Report.xls
DETAILS OF RAILWAY AFFECTING TANK IN
Name of District : HASSAN Name of Division : PRE HASSAN
Name of Railway line: Hassan - Sakaleshpura

1 Name of Tank : Kithaganamane U.M Kere

2 Owner shiip : Zilla Panchayat Hassan.

3 Village / Taluk : Kithaganamane / ALUR

4 Reference to sy.No. Stagement Map. : -

5 Between Railway Station. : Hassan to S.K.Pur Railway line Heddurga-


gummanahally road level Crossing

6 Approximate Location WRT Railway line. :

7 Catchment area in Sq miles/Sqm.Kms. : 0.05 Sq Kmc


8 Maximum calculated suspens discharge in : 70 Cumecs 041.97 cubic Mtrs
acres/cumes.
9 Approximate Storage capacity in million : 2.75 mcum
cubic mtrs.
10 Approximate area of water spred F.I.L in : 0.088 sqmm
Sq. miles/sq Kms.
11 F.T.L In Mtrs. : 102.00 Mtrs
12 M.W.L. In Mtrs. :
13 R.L.of Bund in mtrs. : 103.00 Mtrs
14 Top width in Mtrs. : 3.00 Mtrs
15 Side slopes of bund pitched & : Bund slope pitched 11/2 :1
16 Particulars of surpusing arrangements : Scopping aproxe
type/length.
17 Crest level of supusing in Mtrs. Length. : 102.00 Mtrs
18 Authority responsible for inspecting & : AEE P.R.E.Sub -Div. Alur& G.P Alur.
Maintance of tank.
19 Kms. Of Railway bridge bund effected. : Near Heddurga-gummanahally road level Crossing
B.R No 65
20 Bridge and span. :

21 R.L.of under side grader slab on spring of :


Only,
22 Railway level : 99.53 Mtrs.(assumed RC)

23 Maximum recorded H.F.L. : 102.00 Mtrs)

24 Railway official responsible :

25 Previous instructions of any. :

26 Remarks. :
Bund Sluice and w/w good condition
E/Kps/R.A.T Report.xls

PRE/POST MANSOON INSPECTION REPORT OF M.I WORKS FOR THE YEAR 2016-17

1 District : Hassan
2 Taluk : Alur
3 Name of Tank : Yadur Maradikere
4 Date of Inspection : 9/8/2016
5 Date of Last test check by Asst. Executive : 2/7/2016
Engineer.
6 Observation : Good
7 Tank Bund:- :
a) Are there T.B.L Stones or other : No
paramanent marks to indicate the
prescribed TBL ?
b) Is the top of bund any where below the : No
prescribed level? (if so specify the length &
shortages)
c) Are the top width and slopes according to : This is an old tank which is not in par with M.I
M.I.S Tandards every where ? (If not standards
specify the lengths & extent of Difficincies)

d) Are there any dangerous gullies, cart track : No


ruts etc. which in your opinion, must be
repaired urgently (If so specify the
locations)
e) Action taken to rectify deficiencies notes : NA
in(a) to (d) above.
II) 1. SURPLUSING ARRANGEMENTS:- :
a) Are the surplussing arrangement at site in : Yes
order (If not indicate the variations).

b) Has the prescribed MWL been exceed : or : No


over flown to indicate that the surplusing
arrangement are in adequate or rendered
inoperative.
c) Is the draft channel capable of carrying the : Yes
designed discharge.
d) Any remidial maasures contemplated & : NA
action taken.
III) Sluice & Other masonry works:- :
a) Are they in good order so as to not effect : sluice head wall requires Reconstruction
the safety of the bund, condition of
controlling arrangements may be indicated.

b) Action taken to rectify any defect noticed. : Nill


IV) GENERAL:- :
a) Progress on works, if any already on hand : Nill
and the probable date of completionof the
same.
b) Any other special remarks of the Inapecting :
officer/official: 1. Under the Railway Track is to be Desilted
and jungle has to be removed
2. Geauge pole to be errected in the tank to
watch danger level of the flood

Assistant Executive Engineer


N0.5, PRE Sub-Dvn, Alur
GUIDENCE FOR SUBMISSION OF DISTRESS REPORT OF INDIVIDUAL I.MI.TANKS.
WHICH ARE RAILWAY AFFECTING.
Performance Report:
GUIDE LINES.

1 Whether water has been over flown above : No


the bund of the(by local enquiry) duringany
of the monsoon till to-day.

2 Are/then any defects noticed in the waste : No


weir of sluice of any supportance of the
tank which may cause damage to the tank.

3 Wheather the level of the bund is below : Not Required


MWL as per M.I standards etc., with
adquate provision of (Free board) or
whether the bund height has to be raised to
render it safe.

4 Catchment to the tank good average or : Average


bad and also whether it has intercepted
catchment that may be ardous to the tank.

5 Any repairs suggested (To be supported by :


line estimates enclosed.)(if any). 1. Under the Railway Track to be Desilted and
jungle has to be removed
2. Geauge pole to be errected in the tank to
watch danger level of the flood

Assistant Executive Engineer


N0.5, PRE Sub-Dvn, Alur
E/Kps/R.A.T Report.xls

DETAILS OF RAILWAY AFFECTING TANK IN


Name of District : HASSAN Name of Division : PRE HASSAN
Name of Railway line: Hassan - Sakaleshpura

1 Name of Tank : Yadur Maradikere


2 Owner shiip : Zilla Panchayat Hassan.

3 Village / Taluk : Yadur / Alur


4 Reference to sy.No. Stagement Map. : -
5 Between Railway Station. : Hassan to S.K.Pura Railway near C.No 33
6 Approximate Location WRT Railway line. :

7 Catchment area in Sq miles/Sqm.Kms. : 0.01 Sq Kmc


8 Maximum calculated suspens discharge in : 14 Cumecs
acres/cumes.
9 Approximate Storage capacity in million : 4 Mcum
cubic mtrs.
10 Approximate area of water spred F.I.L in : 0.04 sqmm
Sq. miles/sq Kms.
11 F.T.L In Mtrs. : 97.56 Mtrs
12 M.W.L. In Mtrs. : 98.01 Mtrs
13 R.L.of Bund in mtrs. : 98.56 mtrs
14 Top width in Mtrs. : 3.00 Mtrs

15 Side slopes of bund pitched & : Bund slope pitched 11/2 :1

16 Particulars of surpusing arrangements : Sloping apron


type/length.
17 Crest level of supusing in Mtrs. Length. : 97.56 Mtrs
18 Authority responsible for inspecting & : AEE P.R.E.Sub -Div. Alur& G.P Alur.
Maintance of tank.
19 Kms. Of Railway bridge bund effected. : Hassan to S.K.Pur Railway near C.No 33
20 Bridge and span. :
21 R.L.of under side grader slab on spring of :
Only,
22 Railway level : 100.32 Mtrs.(assumed RC)
23 Maximum recorded H.F.L. : (98.01 Mtrs)
24 Railway official responsible :

25 Previous instructions of any. :

26 Remarks. :

E/Kps/R.A.T Report.xls
Assistant Executive Engineer
N0.5, PRE Sub-Dvn, Alur

PRE/POST MANSOON INSPECTION REPORT OF M.I WORKS FOR THE YEAR 2016-17

1 District : Hassan
2 Taluk : Alur
3 Name of Tank : Kanchanahally Pura U.M Kere
4 Date of Inspection : 9/8/2016
5 Date of Last test check by Asst. Executive : 2/7/2016
Engineer.
6 Observation : Good
7 Tank Bund:- :
a) Are there T.B.L Stones or other : NIL
paramanent marks to indicate the
prescribed TBL ?
b) Is the top of bund any where below the : NIL
prescribed level? (if so specify the length &
shortages)
c) Are the top width and slopes according to : MI Standard
M.I.S Tandards every where ? (If not
specify the lengths & extent of Difficincies)

d) Are there any dangerous gullies, cart track : NIL


ruts etc. which in your opinion, must be
repaired urgently (If so specify the
locations)
e) Action taken to rectify deficiencies notes : -
in(a) to (d) above.
II) 1. SURPLUSING ARRANGEMENTS:- :
a) Are the surplussing arrangement at site in : NO
order (If not indicate the variations).

b) Has the prescribed MWL been exceed : or : NIL


over flown to indicate that the surplusing
arrangement are in adequate or rendered
inoperative.
c) Is the draft channel capable of carrying the : -
designed discharge.
d) Any remidial maasures contemplated & : NIL
action taken.
III) Sluice & Other masonry works:- :
a) Are they in good order so as to not effect : Good Condition
the safety of the bund, condition of
controlling arrangements may be indicated.

b) Action taken to rectify any defect noticed. :

IV) GENERAL:- :
a) Progress on works, if any already on hand :
and the probable date of completionof the
same.
b) Any other special remarks of the Inapecting :
officer/official:

E/Kps/R.A.T Report.xls Assistant Executive Engineer


N0.5, PRE Sub-Dvn, Alur

GUIDENCE FOR SUBMISSION OF DISTRESS REPORT OF INDIVIDUAL I.MI.TANKS.


WHICH ARE RAILWAY AFFECTING.
Performance Report:
GUIDE LINES.

1 Whether water has been over flown above : NIL


the bund of the(by local enquiry) duringany
of the monsoon till to-day.

2 Are/then any defects noticed in the waste : NIL


weir of sluice of any supportance of the
tank which may cause damage to the tank.

3 Wheather the level of the bund is below : NIL


MWL as per M.I standards etc., with
adquate provision of (Free board) or
whether the bund height has to be raised to
render it safe.

4 Catchment to the tank good average or : Average


bad and also whether it has intercepted
catchment that may be ardous to the tank.

5 Any repairs suggested (To be supported by :


line estimates enclosed.)(if any).

Assistant Executive Engineer


N0.5, PRE Sub-Dvn, Alur

E/Kps/R.A.T Report.xls

DETAILS OF RAILWAY AFFECTING TANK IN


Name of District : HASSAN Name of Division : PRE HASSAN
Name of Railway line: Hassan - Sakaleshpura

1 Name of Tank : Kenchanahally Pura U.M Kere

2 Owner shiip : Zilla Panchayat Hassan.

3 Village / Taluk : Kenchanahally / ALUR


4 Reference to sy.No. Stagement Map. : -
5 Between Railway Station. : Hassan to S.K.Pura Railway line Heddurga-
gummanahally road level Crossing
6 Approximate Location WRT Railway line. :

7 Catchment area in Sq miles/Sqm.Kms. : 0.05 Sq Kmc


8 Maximum calculated suspens discharge in :
acres/cumes.
9 Approximate Storage capacity in million : 2 mcum
cubic mtrs.
10 Approximate area of water spred F.I.L in : 0.017 sqmm
Sq. miles/sq Kms.
11 F.T.L In Mtrs. : 103.50 Mtrs
12 M.W.L. In Mtrs. : 103.95 Mtrs
13 R.L.of Bund in mtrs. : 104.30 Mtrs
14 Top width in Mtrs. : 4.00 Mtrs
15 Side slopes of bund pitched & : Bund slope pitched 11/2 :1

16 Particulars of surpusing arrangements : Scopping aproxe


type/length.

17 Crest level of supusing in Mtrs. Length. : 103.50 Mtrs

18 Authority responsible for inspecting & : AEE P.R.E.Sub -Div. Alur& G.P Alur
Maintance of tank.
19 Kms. Of Railway bridge bund effected. : Hassan to S.K.Pur Railway line Near C.No - 58

20 Bridge and span. :

21 R.L.of under side grader slab on spring of :


Only,
22 Railway level : 99.85 Mtrs.(assumed RC)

23 Maximum recorded H.F.L. : 103.95 Mtrs)


24 Railway official responsible :
25 Previous instructions of any. :
26 Remarks. :

E/Kps/R.A.T Report.xls

Assistant Executive Engineer


N0.5, PRE Sub-Dvn, Alur

PRE/POST MANSOON INSPECTION REPORT OF M.I WORKS FOR THE YEAR 2016-17

1 District : Hassan
2 Taluk : Alur
3 Name of Tank : Kongavally Arasikere
4 Date of Inspection : 9/8/2016
5 Date of Last test check by Asst. Executive : 2/7/2016
Engineer.
6 Observation : Good
7 Tank Bund:- :
a) Are there T.B.L Stones or other : NIL
paramanent marks to indicate the
prescribed TBL ?
b) Is the top of bund any where below the : NIL
prescribed level? (if so specify the length &
shortages)
c) Are the top width and slopes according to : MI Standard
M.I.S Tandards every where ? (If not
specify the lengths & extent of Difficincies)

d) Are there any dangerous gullies, cart track : NIL


ruts etc. which in your opinion, must be
repaired urgently (If so specify the
locations)
e) Action taken to rectify deficiencies notes : -
in(a) to (d) above.
II) 1. SURPLUSING ARRANGEMENTS:- :
a) Are the surplussing arrangement at site in : NO
order (If not indicate the variations).
b) Has the prescribed MWL been exceed : or : NIL
over flown to indicate that the surplusing
arrangement are in adequate or rendered
inoperative.
c) Is the draft channel capable of carrying the : -
designed discharge.
d) Any remidial maasures contemplated & : NIL
action taken.
III) Sluice & Other masonry works:- :
a) Are they in good order so as to not effect : Good Condition
the safety of the bund, condition of
controlling arrangements may be indicated.

b) Action taken to rectify any defect noticed. :

IV) GENERAL:- :
a) Progress on works, if any already on hand :
and the probable date of completionof the
same.
b) Any other special remarks of the Inapecting : jungle clearance and Repairs w/w
officer/official:

Assistant Executive Engineer


E/Kps/R.A.T Report.xls N0.5, PRE Sub-Dvn, Alur

GUIDENCE FOR SUBMISSION OF DISTRESS REPORT OF INDIVIDUAL I.MI.TANKS.


WHICH ARE RAILWAY AFFECTING.
Performance Report:
GUIDE LINES.

1 Whether water has been over flown above : NIL


the bund of the(by local enquiry) duringany
of the monsoon till to-day.

2 Are/then any defects noticed in the waste : NIL


weir of sluice of any supportance of the
tank which may cause damage to the tank.

3 Wheather the level of the bund is below : NIL


MWL as per M.I standards etc., with
adquate provision of (Free board) or
whether the bund height has to be raised to
render it safe.

4 Catchment to the tank good average or : Average


bad and also whether it has intercepted
catchment that may be ardous to the tank.
5 Any repairs suggested (To be supported by : jungle clearance and Repairs w/w
line estimates enclosed.)(if any).

Assistant Executive Engineer


N0.5, PRE Sub-Dvn, Alur

E/Kps/R.A.T Report.xls

DETAILS OF RAILWAY AFFECTING TANK IN


Name of District : HASSAN Name of Division : PRE HASSAN
Name of Railway line: Hassan - Sakaleshpura

1 Name of Tank : Kongavally Arasikere


2 Owner shiip : Zilla Panchayat Hassan.
3 Village / Taluk : Kongavally / ALUR
4 Reference to sy.No. Stagement Map. : -

5 Between Railway Station. : Hassan to S.K.Pur Railway line Kongavally road


level Crossing
6 Approximate Location WRT Railway line. :

7 Catchment area in Sq miles/Sqm.Kms. : 0.10 Sq Kmc

8 Maximum calculated suspens discharge in : 1.30 Cumecs 3.65 cubic Mtrs


acres/cumes.
9 Approximate Storage capacity in million : 4mcum
cubic mtrs.
10 Approximate area of water spred F.I.L in : 0.029 km2
Sq. miles/sq Kms.
11 F.T.L In Mtrs. : 96.74 Mtrs
12 M.W.L. In Mtrs. : 97.15 Mtrs

13 R.L.of Bund in mtrs. : 97.94 Mtrs


14 Top width in Mtrs. : 3.00 Mtrs

15 Side slopes of bund pitched & : Bund slope pitched 11/2 :1

16 Particulars of surpusing arrangements : Scopping aproxe


type/length.

17 Crest level of supusing in Mtrs. Length. : 96.74 Mtrs

18 Authority responsible for inspecting & : AEE A.P.E.Sub -Div. Alur& G.P
Maintance of tank.
19 Kms. Of Railway bridge bund effected. : Near Kongavally level crossing B.R No 72
20 Bridge and span. :

21 R.L.of under side grader slab on spring of :


Only,
22 Railway level : 99.41 Mtrs.(assumed RL)
23 Maximum recorded H.F.L. :
24 Railway official responsible :

25 Previous instructions of any. :

26 Remarks. : jungle clearance and Repairs w/w

E/Kps/R.A.T Report.xls
Assistant Executive Engineer
N0.5, PRE Sub-Dvn, Alur

PRE/POST MANSOON INSPECTION REPORT OF M.I WORKS FOR THE YEAR 2016-17

1 District : Hassan
2 Taluk : Alur
3 Name of Tank : Kogilakatte
4 Date of Inspection : 9/8/2016
5 Date of Last test check by Asst. Executive : 2/7/2016
Engineer.
6 Observation : Good
7 Tank Bund:- :
a) Are there T.B.L Stones or other : No
paramanent marks to indicate the
prescribed TBL ?
b) Is the top of bund any where below the : No
prescribed level? (if so specify the length &
shortages)
c) Are the top width and slopes according to : This is an old tank which is not in par with M.I
M.I.S Tandards every where ? (If not standards
specify the lengths & extent of Difficincies)
d) Are there any dangerous gullies, cart track : No
ruts etc. which in your opinion, must be
repaired urgently (If so specify the
locations)
e) Action taken to rectify deficiencies notes : NA
in(a) to (d) above.
II) 1. SURPLUSING ARRANGEMENTS:- :
a) Are the surplussing arrangement at site in : Yes
order (If not indicate the variations).

b) Has the prescribed MWL been exceed : or : No


over flown to indicate that the surplusing
arrangement are in adequate or rendered
inoperative.
c) Is the draft channel capable of carrying the : Yes
designed discharge.
d) Any remidial maasures contemplated & : NA
action taken.
III) Sluice & Other masonry works:- :
a) Are they in good order so as to not effect : sluice head wall requires Reconstruction
the safety of the bund, condition of
controlling arrangements may be indicated.

b) Action taken to rectify any defect noticed. : Nill

IV) GENERAL:- :
a) Progress on works, if any already on hand : Nill
and the probable date on completion the
roof.
b) Any other special remarks of the Inapecting : 1. Under the Railway Track to be Desilted and
officer/official: jungle has to be removed 2.
Geauge pole to be errected in the tank to watch
danger level of the flood

Assistant Executive Engineer


N0.5, PRE Sub-Dvn, Alur
GUIDENCE FOR SUBMISSION OF DISTRESS REPORT OF INDIVIDUAL I.MI.TANKS.
WHICH ARE RAILWAY AFFECTING.
Performance Report:
GUIDE LINES.

1 Whether water has been over flown above : No


the bund of the(by local enquiry) duringany
of the monsoon till to-day.

2 Are/then any defects noticed in the waste : No


weir of sluice of any supportance of the
tank which may cause damage to the tank.

3 Wheather the level of the bund is below : Not Required


MWL as per M.I standards etc., with
adquate provision of (Free board) or
whether the bund height has to be raised to
render it safe.
4 Catchment to the tank good average or : Average
bad and also whether it has intercepted
catchment that may be ardous to the tank.

5 Any repairs suggested (To be supported by :


line estimates enclosed.)(if any). 1. Under the Railway Track is to be Desilted
and jungle has to be removed
2. Geauge pole to be errected in the tank to
watch danger level of the flood

Assistant Executive Engineer


N0.5, PRE Sub-Dvn, Alur

E/Kps/R.A.T Report.xls

DETAILS OF RAILWAY AFFECTING TANK IN


Name of District : HASSAN Name of Division : PRE HASSAN
Name of Railway line: Hassan - Sakaleshpura

1 Name of Tank : Kogilakatte


2 Owner shiip : Zilla Panchayat Hassan.
3 Village / Taluk : Alur / ALUR
4 Reference to sy.No. Stagement Map. : -
5 Between Railway Station. : Hassan to S.K.Pur Railway line Near
Hanthanamane track
6 Approximate Location WRT Railway line. :

7 Catchment area in Sq miles/Sqm.Kms. : 0.03 Sq Kmc


8 Maximum calculated suspens discharge in :
acres/cumes.
9 Approximate Storage capacity in million : 1 Mcum
cubic mtrs.
10 Approximate area of water spred F.I.L in : 0.008 km2
Sq. miles/sq Kms.
11 F.T.L In Mtrs. : 96.74 Mtrs
12 M.W.L. In Mtrs. : 97.15 Mtrs
13 R.L.of Bund in mtrs. : 97.94 Mtrs
14 Top width in Mtrs. : 2.00 Mtrs
15 Side slopes of bund pitched & : Bund slope pitched 11/2 :1
16 Particulars of surpusing arrangements : Scopping aproxe
type/length.
17 Crest level of supusing in Mtrs. Length. :
18 Authority responsible for inspecting & : AEE A.P.E.Sub -Div. Alur& G.P
Maintance of tank.
19 Kms. Of Railway bridge bund effected. : Near Hanthanamane B.R. No 42
20 Bridge and span. :
21 R.L.of under side grader slab on spring of :
Only,
22 Railway level :
23 Maximum recorded H.F.L. :
24 Railway official responsible :
25 Previous instructions of any. :
26 Remarks. : 1. Under the Railway Track to be Desilted and
jungle has to be removed 2.
Geauge pole to be errected in the tank to watch
danger level of the flood

Assistant Executive Engineer


E/Kps/R.A.T Report.xls N0.5, PRE Sub-Dvn, Alur
LIST OF RAILWAY EFFECTING TANK IN : ALUR TALUK

Condition of
Dist. & Tank in bund whether Adequecy of
Sl. which Railway it is capable of waste weir to
Name of Tank Remarks.
No. affecting tank holding discharge the
situated. disigned designed flood
discharge
1 2 3 4 5 6

Bund Sluice and w/w good


1 Kithaganamane U.M Kere Hassan / Alur Safe Suffcient
condition

Certified that I have inspected the tank and the appetrenant items personally on 09/08/2016 and the tank in safe.

E/Kps/R.A.T Report.xls
LIST OF RAILWAY EFFECTING TANK IN : ALUR TALUK

Condition of
Dist. & Tank in bund whether Adequecy of
Sl. which Railway it is capable of waste weir to
Name of Tank Remarks.
No. affecting tank holding discharge the
situated. disigned designed flood
discharge

1 2 3 4 5 6

1. Under the Railway Track to


be Desilted and jungle has to be
removed 2.
1 Hanthanamane Aralikatte Hassan / Alur Safe Suffcient
Geauge pole to be errected in
the tank to watch danger level
of the flood

Certified that I have inspected the tank and the appetrenant items personally on 09/08/2016 and the tank is safe.

Assistant Executive Engineer


N0.5, PRE Sub-Dvn, Alur
LIST OF RAILWAY EFFECTING TANK IN : ALUR TALUK

Condition of
Dist. & Tank in bund whether Adequecy of
Sl. which Railway it is capable of waste weir to
Name of Tank Remarks.
No. affecting tank holding discharge the
situated. disigned designed flood
discharge

1 2 3 4 5 6

1. Under the Railway Track to


be Desilted and jungle has to be
removed
1 Yadur Maradikere Hassan / Alur Safe Suffcient
2. Geauge pole to be errected in
the tank to watch danger level
of the flood

Certified that I have inspected the tank and the appetrenant items personally on 09/08/2016 and the tank is safe.

Assistant Executive Engineer


N0.5, PRE Sub-Dvn, Alur
LIST OF RAILWAY EFFECTING TANK IN : ALUR TALUK

Condition of
Dist. & Tank in bund whether Adequecy of
Sl. which Railway it is capable of waste weir to
Name of Tank Remarks.
No. affecting tank holding discharge the
situated. disigned designed flood
discharge

1 2 3 4 5 6

1 Kenchanahally pura U.M Kere Hassan / Alur Safe Suffcient

Certified that I have inspected the tank and the appetrenant items personally on 09/08/2016 and the tank in safe.

Assistant Executive Engineer


N0.5, PRE Sub-Dvn, Alur
LIST OF RAILWAY EFFECTING TANK IN : ALUR TALUK

Condition of
Dist. & Tank in bund whether Adequecy of
Sl. which Railway it is capable of waste weir to
Name of Tank Remarks.
No. affecting tank holding discharge the
situated. disigned designed flood
discharge

1 2 3 4 5 6

jungle clearance and Repairs


1 Kongavally Arasikere Hassan / Alur Safe Suffcient
w/w

Certified that I have inspected the tank and the appetrenant items personally on 09/08/2016 and the tank in safe.

Assistant Executive Engineer


N0.5, PRE Sub-Dvn, Alur
LIST OF RAILWAY EFFECTING TANK IN : ALUR TALUK

Condition of
Dist. & Tank in bunt whether if Adequecy of
Sl. which Railway is capable of waste weir the
Name of Tank Remarks.
No. affecting tank holdings discharge the
situated. disigned designed flood
discharge
1 2 3 4 5 6
1. Under the Railway Track to
be Desilted and jungle has to
be removed
1 Alur Koglilakatte Hassan / Alur Safe Suffcient
2. Geauge pole to be errected
in the tank to watch danger
level of the flood

Certified that I have inspected the tank and the appetrenant items personally on 09/08/2016 and the tank is safe.

Assistant Executive Engineer


N0.5, PRE Sub-Dvn, Alur
catchment Area Present Hydralic Particular of tank
Sl Atchkat in
Name of tank capasity of Remarks
No H.A
tank MCFt
Max head utilisation of
Independent Intercepted
discharge mcft
1 Jiganemane kere 0.90 0.90 251 6.17 15.00
2 Gundalakadde kere 0.90 0.90 251 1.23 3.00

3 Byadarakere 3.50 4.55 798 9.16 22.25

4 Gulagalale kere 0.50 0.40 750 1.65 7.00