Step 1 - Wire Back Panel PWR SIG COM: Quick Install Guide

This quick install guide summarizes the steps to set up a controller in 3 sentences: Step 1 involves wiring the back panel by plugging in connectors for valves and field devices and connecting the battery and solar panel. Step 2 covers basic security setup like setting an operator ID. Step 3 is to set the date and time. Step 4 reviews configuring inputs and outputs as well as alarms, optimization, and install settings. Step 5 explains how to start the controller and reset it to an open or closed state.
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
93 views

Step 1 - Wire Back Panel PWR SIG COM: Quick Install Guide

This quick install guide summarizes the steps to set up a controller in 3 sentences: Step 1 involves wiring the back panel by plugging in connectors for valves and field devices and connecting the battery and solar panel. Step 2 covers basic security setup like setting an operator ID. Step 3 is to set the date and time. Step 4 reviews configuring inputs and outputs as well as alarms, optimization, and install settings. Step 5 explains how to start the controller and reset it to an open or closed state.
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Quick Install

Guide

Step 1 - Wire Back Panel


a) Plug in Valve Connectors.
b) Connect Field Devices.
PWR
- 2 Wire Switches are wired to COM and SIG. SIG
- 3 Wire Sensors are wired to PWR, COM and SIG. COM
c) Plug in Battery Connection.
d) Connect Solar Panel.

Step 2 - Setup Security Step 4 - Controller Setup


a) Press instll.
install a) Press instll
install and then scroll to Inputs.

c) Enter the default login of 000-0000. b) Enable and configure any required
devices.
b) Scroll down to the Security menu.
c) Press cncl
cancel to back out to the menu.
b) Press selct
select and scroll down until you
5

see Operator ID. d) Scroll to Outputs to enable additional


valves in the same manner.
d) Press selct and set the desired ID.
5
select
e) Enter the Alarms menu to configure the
e) Change the Installer ID in the same behaviour when failures occur.
manner.
f ) Enter Optimize to set the optimization.
Note: Changes to install settings do not
Step 3 - Set Date/Time take effect until the next Close cycle.
a) Press instll
install and scroll to Date/Time.

Step 5 - Start Controller


b) Press selct
5
select
to enter the menu.
a) Press clse
close or opn
open to reset the controller

c) Adjust the Date and/or Time. to a given state.


d) Set the Daylight savings time option to b) The controller will set the valves and the
on if desired. screen will update to show the current
state and remaining time.

www.ETCorp.ca
Quick Tips

Changing Timers/Set Points View History


a) Press setin.
settings a) Press htry
history to enter the History menu.

b) Use the up/down arrow keys to scroll b) Selct


5
select
the type of history you wish to see.
through each setting.
c) Scroll through each history screen.
c) Press selct
5
select
to edit a given setting.
Note: All logs in the history menu have
Note: Most timers are related to each multiple records displayed in reverse
other and will auto adjust. Values entered chronological order.
below the min or above the max will be
adjusted automatically. Modifying Alarms
Note: Timer settings do not take effect install and scroll to the Alarms
a) Press instll
until the next Close cycle. menu.
b) Scroll to the desired alarm setting and
Adding/Removing Devices press selct
5 to modify it.
select

a) Press instl
install and then scroll to the Inputs Note: Fast Trip and Non Arrival alarms are
menu. consecutive occurances.
b) Press selct
5
select
and then scroll through each
screen. Configure Modbus
install and scroll to the Modbus
a) Press instll
c) Press selct
5
select
to edit a given setting.
menu.
Note: Additional device screens are
hidden until the device is enabled. b) Press selct
5
select
to enter the menu.

Note: Changes to input settings do not c) Select the Modbus Port and set it to
take effect until the next Close cycle. enabled.
d) Scroll through each setting, ensuring
Change State Manually that it matches the Modbus master.

a) From the main screen, press selct.


5 Note: To communicate properly, all
select
communication settings must match the
ET-12000-1018-0000 rev 3

b) Select yes, and then set the desired state master’s settings.
and time.
c) The controller will enter the desired state
and then resume normal operation once
complete.