Confidential Copyright © 1999-2008 TOSHIBA CORPORATION./TOSHIBA SIGMA CONSULTING All rights reserved. 1
Content

LG Philip --------------------- 3 ~ 11

LPL Part List --------------------- 12

Samsung -------------------- 13 ~ 18

Samsung Part List -------------------- 19

AU Optical --------------------- 20 ~ 33

AUO Part List --------------------- 34

CMO / IPS Part List -------------------- 35

2
Troubleshooting of LPL ( LG Philip )
Display Panel

3
Picture
Problem

Does
NO the back light turn ON YES
Normally

Are
NO YES NO there lines, bars, YES
Does the Audio
or pixel problems
Present
in the picture?

Suspect an
Suspect Suspect Suspect LCD
Inverter problem
Power Unit T-Con Defect Panel Defect
in the display
Problem Page: 5 ~ 6 Page: 10 ~ 11
Page: 7 ~ 9

4
Symptom cause by Timing-Control ( LPL )

- Exchange T-Con: Case.1~ Case14

5
How to replace of T-Con board ( LPL )

( 1 ) Prepare the LCM ( 2 ) Separate the Screw(4EA) ( 3 ) Separate the Cover Shield

( 4 ) Separate the FFC(50pin) ( 5 ) Separate the T-Con Board

( 6 ) Replace of T-Con Board and


Assemble the FFC(50pin)
*Guide pin station keeping chec

( 8 ) Attach the Cover Shield ( 7 ) Check the FFC(50pin)


And Assemble the Screw(4EA)
6
Symptom cause by Inverter ( LPL )

- Exchange Inverter: Case.15~ Case18

7
How to replace of Inverter ( LPL )
( 1 ) Separate Cover Shield
(Inverter) Master, Slave

( 2 ) Separate Inverter (Master, ( 3 ) Separate Sync, ( 4 ) Inspect new Inverter


Slave), Wire Connector Cable ( FFC Cable) (Master, Slave)

Trans
Trans
Rank

# Check the Inverter (Master,


# Sync, Cable( FFC Slave) Trans Rank Should be the
# Be careful Wire Connector Cable)
same
8
How to replace of Inverter ( LPL )

( 5 ) Attach new Inverter ( 6 ). Attach Sync, Cable ( 7 ) Assemble Inverter


(Master, Slave) to ( FFC Cable) (Master, Slave) & Wire
Backlight Connector
embo

# Sync, Cable( FFC Cable)


( 8 ) Assemble Cover Shield Wrier Connector
(Inverter) Master, Slave ( 10 ) Turn on & Check the
LCM

# Cover Shield (Inverter)


Master, Slave Inverter (Master,)
9
Symptom cause by LCD Panel ( LPL )

- Un repairable Exchange LCD Panel: Case.19~ Case24

10
Symptom cause by LCD Panel ( LPL )

- Un repairable Exchange LCD Panel: Case.19~ Case24

11
Service Instruction

12
Troubleshooting of Samsung
Display Panel

13
Picture
Problem

Does
NO the back light turn ON YES
Normally

Are
NO Does the Audio YES NO there lines, bars, YES
Present or pixel problems
in the picture?

Suspect an
Suspect Suspect LCD
Inverter problem
Power Unit T-Con Defect Panel Defect
in the display
Page: 15 ~ 17
Page: 18

14
Panel Symptom cause by T-Con ( Timing Control Board )

15
Panel Symptom cause by T-Con ( Timing Control Board )

16
Panel Symptom cause by T-Con ( Timing Control Board )

17
Panel Symptom cause by Inverter

18
Service Instruction

19
Troubleshooting of AUO
Display Panel

20
Picture
Problem

Does
NO YES
the back light turn ON
Normally

Are
NO Does the Audio YES NO there lines, bars, YES
Present or pixel problems
in the picture?

Suspect an
Suspect Suspect LCD
Inverter problem
Power Unit T-Con Defect Panel Defect
in the display
Page: 23 ~ 28 Page: 29~ 33
Page: 22

21
LPL LCD Panel Symptom cause by Inverter

Symptom :Lamp Shutdown


Change Inverter first if fail, means lamp tube broken,
Replace LCD Panel

22
Panel Symptom cause by T-Con ( Timing Control Board )

Symptom : H-line blinking at scale pattern


ASIC NG
Replace T-con

Some short H-line blinking at scale pattern


23
Panel Symptom cause by T-Con ( Timing Control Board )

Symptom: Abnormal Display


Change T-con first, if fail then replace LCD Panel

NEC IC function fail

24
Panel Symptom cause by T-Con ( Timing Control Board )

Symptom : No Display (BL is OK)


High possibility T-con component fail,
Replace T-con

Please make sure BL is switch on or not first (could be check from the backside)

25
Panel Symptom cause by T-Con ( Timing Control Board )

Symptom : Abnormal Display


T-con component NG,
Replace T-con

26
Panel Symptom cause by T-Con ( Timing Control Board )

Symptom :Whitened Display (all patterns)


Check VR Knob first, if normal, then replace T-con

27
Panel Symptom cause by T-Con ( Timing Control Board )

Symptom: Abnormal display


Change T-con first, if fail, then replace LCD panel

Source IC NG

28
Symptom cause by Panel

Symptom: H-block
Replace LCD panel

Block or band (wider than one line) Data IC COF lead


broken

29
Symptom cause by Panel

Symptom : Abnormal Display


Change T-con first, if fail then replace LCD panel

NEC IC function fail

30
Symptom cause by Panel

Symptom : LC Air Bubble


External force cause glass broken,
Replace LCD Panel

31
Symptom cause by Panel

Symptom : V-Line
Replace LCD Panel

32
Symptom cause by Panel

Symptom : H Line
Replace LCD Panel

33