This document provides notes for a structural drawing including that all dimensions are in feet and inches, to not scale from the drawing and instead use stated dimensions, and that all reinforcement steel strengths conform to ASTM A615/A615M standards and are either high tensile grade 60 steel or standard grade 40 steel.

Uploaded by

James Pitts
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
58 views1 page

S-23 - Misc Details

This document provides notes for a structural drawing including that all dimensions are in feet and inches, to not scale from the drawing and instead use stated dimensions, and that all reinforcement steel strengths conform to ASTM A615/A615M standards and are either high tensile grade 60 steel or standard grade 40 steel.

Uploaded by

James Pitts
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

NOTES

1.
1. All
All dimensions
dimensions are are in in Feet
Feet && Inches
Inches unless
unless
otherwise
otherwise stated.
stated.
2.
2. Do
Do not
not scale
scale from
from thisthis drawing
drawing use
use
figured
figured dimensions
dimensions only. only.
3.
3. All
All reinforcement
reinforcement steel steel strengths
strengths
designated
designated on on drawings
drawings to to conform
conform with
with
ASTM
ASTM A615/A615M
A615/A615M or or equivalent
equivalent asas
follows:
follows:
T - High tensile steel,ASTM
T - High tensile steel,ASTM grade 60 grade 60
(fy
(fy == 420MPa)
420MPa) ..
R
R -- Mild
Mild steel,ASTM
steel,ASTM grade grade 40
40
(fy
(fy == 280MPa).
280MPa).
4.
4. Concrete
Concrete covercover to to reinforcement
reinforcement to to be
be as
as
follows:
follows:
Foundations
Foundations -- 50mm 50mm aboveabove conc.
conc.
blinding.
blinding.
Ground
Ground BeamsBeams -- 50mm;75mm
50mm;75mm on on soil
soil
surface.
surface.
5.
5. Rebar
Rebar lapslaps shall
shall bebe provided
provided where
where
applicable
applicable to to suit
suit construction
construction logistics.
logistics.
Minimum
Minimum steel steel reinforcement
reinforcement lap lap lengths:
lengths:
10mmØ=500mm.
10mmØ=500mm.
12mmØ=600mm.
12mmØ=600mm.
16mmØ=750mm.
16mmØ=750mm.
20mmØ=910mm.
20mmØ=910mm.
6.
6. All
All structural
structural drawings
drawings to to be
be verified
verified with
with
Architectural
Architectural details.
details. Any Any discrepancies
discrepancies
to
to be
be brought
brought to to the
the attention
attention of
of the
the
Engineer.
Engineer.
7.
7. Contractor
Contractor to to verify
verify allall dimensions
dimensions
prior
prior toto construction.
construction.

8.
8. All
All concrete
concrete toto be
be supplied
supplied and
and
installed
installed in
in accordance
accordance with
with American
American
Concrete
Concrete Institute
Institute ACI
ACI 318
318 Building
Building
Code
Code Requirements
Requirements for for Structural
Structural
Concrete
Concrete or other equivalent and
or other equivalent and
approved
approved standard.
standard.
9.
9. Concrete
Concrete shall
shall bebe mechanically
mechanically
compacted in the approved
compacted in the approved manner. manner.
10.
10. Methodology
Methodology of of curing
curing concrete
concrete toto be
be
approved
approved by by the
the supervising
supervising Engineer.
Engineer.
11.
11. All
All rebars
rebars inin block
block work
work to
to be
be
inspected
inspected before grouting and to be free
before grouting and to be free
of
of debris,
debris, loose
loose mortar
mortar etc.
etc.

NOTE: ALL SPLICES TO BE LOCATED 4' ABOVE


FINISHED FLOOR LEVEL

-Balance Bars or Negative Reinforcement


- SECTION PATIO FLOOR SLAB - Over Filler Beams

JOB TITLE:
DRAWING TITLE: DWG NO: CONSULTANT

CIVPRO ENGINEERING RENOVATION TO HEAD OFFICES MISCELLANEOUS DETAILS S-23


LIMITED LOT#M2, CENTURY DRIVE, ETECK
T
:el 8(64
89
)10-809 TRINCITY INDUSTRIAL PARK, MACOYA. JOB NO.: ----- DRAWN: NS
E
:mlai [email protected] DATE: 11.10.20 CHECKED: NmS A 11.10.20 FIRST ISSUE NmS
CLIENT: BARAD
H
AOLD
N
IG
L
S
TD
SCALE: AS SHOWN DESIGN: NmS ISSUE DATE DESCRIPTION INIT. ISSUE DATE DESCRIPTION INIT.