S-18 - Connection Details
S-18 - Connection Details
C
2. Do not scale from this drawing use
figured dimensions only.
1
"
2 W12x30 2" 312" 2" 3. All reinforcement steel strengths
designated on drawings to conform with
ASTM A615/A615M or equivalent as
follows:
T - High tensile steel,ASTM grade 60
(fy = 420MPa) .
R - Mild steel,ASTM grade 40
13 16"
13 16"
(fy = 280MPa).
4. Concrete cover to reinforcement to be as
follows:
Foundations - 50mm above conc.
blinding.
3"
applicable to suit construction logistics.
Minimum steel reinforcement lap lengths:
10"
W12 X 26
10mmØ=500mm.
12mmØ=600mm.
16mmØ=750mm.
3"
20mmØ=910mm.
6. All structural drawings to be verified with
Architectural details. Any discrepancies
to be brought to the attention of the
Engineer.
3
8" Thk. plate welded 7. Contractor to verify all dimensions
13 16"
prior to construction.
13 16"
to beam using 6mm 8. All concrete to be supplied and
installed in accordance with American
Concrete Institute ACI 318 Building
fillet weld Code Requirements for Structural
Concrete or other equivalent and
approved standard.
9. Concrete shall be mechanically
C
compacted in the approved manner.
712" 10. Methodology of curing concrete to be
approved by the supervising Engineer.
11. All rebars in block work to be
inspected before grouting and to be free
JOB TITLE:
DRAWING TITLE: DWG NO: CONSULTANT