0% found this document useful (0 votes)
176 views5 pages

1st Floor Slab Design Sample PDF

This document provides calculations for the design of a reinforced concrete slab. It includes definitions of terms used, references to relevant code standards, and calculations for slab properties including bending moments, required reinforcement areas, shear stresses, and reinforcement details. The slab being designed is for a 1st floor residential building with a span of 4.62m by 3.63m and 127mm thickness. Reinforcement is determined to be T8 bars at 200mm centers to satisfy bending and cracking requirements based on code-specified design loads. Shear stresses are also calculated to verify requirements.

Uploaded by

Sanjeev Sanjeev
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
176 views5 pages

1st Floor Slab Design Sample PDF

This document provides calculations for the design of a reinforced concrete slab. It includes definitions of terms used, references to relevant code standards, and calculations for slab properties including bending moments, required reinforcement areas, shear stresses, and reinforcement details. The slab being designed is for a 1st floor residential building with a span of 4.62m by 3.63m and 127mm thickness. Reinforcement is determined to be T8 bars at 200mm centers to satisfy bending and cracking requirements based on code-specified design loads. Shear stresses are also calculated to verify requirements.

Uploaded by

Sanjeev Sanjeev
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

Page 1 of 5

SLAB DESIGN CALCULATIONS


Project Name : Residential bld design
Client Name : ....................
Engineer Name : ..............................
Analysis File : C:\Users\HP\Desktop\rrrrrrrrrrrrrrr.mdb
Analysis Last Modified : 10/30/2020 5:38:02 PM

NOTES:
1. Slab is designed as per 1 M width of panel.
2. Density of concrete assumed as 25 kN/Cum.
3. Maximum spacing of Main steel is smaller of (3 x Deff and 300 mm)
4. Maximum spacing of Distribution steel is smaller of (5 x Deff and 450 mm)
5. All 6 mm diameter bars assumed of Fe250 grade with Fy=250 N/sq.mm

Definitions Of Terms: :
1. α = Coefficient of Thermal Expansion
2. acr = Distance from the point considered to the surface of the
nearest longitudinal bar
3. εm = Average steel strain at level considered
Strain at level considered, Calculated ignoring the stiffening
4. ε1 =
of the concrete in tension zone
5. ρact = Percentage steel provided
6. ρcrit = Percentage steel critical as per code
7. BM = Bending moment in kNm
8. D = Overall depth of slab in mm
9. Deff = Effective depth of slab in mm
10. Ec = Modulus of elasticity of concrete
11. Es = Modulus of elasticity of steel
12. Fck = Characteristic compressive strength of concrete cube in
N/sqmm
13. Fst = Stress in steel
14. Fy = Yield Stress Of Steel in N/sqmm
15. Mu = Factored Bending moment in kNm
16. Sp = Spacing Between bars at outer most layer
17. Tc = Permissible Shear stress in concrete in N/sqmm
18. Temp1 = Peak Hydration temperature
19. Temp2 = Seasonal Temperature Variations
20. Tv = Shear stress due to Vu in N/sqmm
21. V = Shear force in kN
22. Vu = Factored shear force in kN
23. Wcr = Surface Crack Width

Code References :

file:///C:/Users/HP/AppData/Local/Temp/tmp94AD.tmp 9/24/2020
Page 2 of 5

IS 456

ELEMENT CLAUSE / TABLE


1. Moment Coeffs For 2-Way Slabs : Greschoff-Rankine Formulation and yield line theory
2. Ptmin : 26.5.2.1
3. Ptcalculated : 38
4. Shear Strength Of Concrete : 40.3
5. Modification Factor for Shear : 40.2.1.1
6. Max Nominal Shear Stress : 40.2.3
7. Basic Span To Depth Ratio : 23.2.1
8. Tensile Steel Factor : 23.2.1
9. Compression Steel Factor : 23.2.1
10. Flange correction factor : 23.2.1
11. spacing between main bars : 26.3.3
12. spacing between distribution bars : 26.3.3
13. crack width calculation : Annex-F
14. cracking : Clause 35.3.2

BS 8007 (For Early / Initial Thermal Cracking)


ELEMENT CLAUSE / TABLE
1. Surface Zone for suspended slab : Figure A.1
2. Surface Zone for ground slab : Figure A.2
Factors for the calculation of
3. : Table A.1
minimum reinforcement

Slab No. : S3
Level = 1ST FLOOR
Design Code = IS Code
Grade Of Concrete = M20
Grade Of Steel = Fe500
Clear Cover = 15.000 mm
Long Span, Ly = 4.620 m
Short Span, Lx = 3.630 m
Imposed Load = 1.500 kN/sqm
Live Load = 2.000 kN/sqm
Slab Thickness = 127.000 mm
Effective Depth Along LX, Deffx = 107.000 mm
Effective Depth Along LY, Deffy = 97.000 mm
Self Weight = 3.175 kN/sqm
Total Load, TL = 6.675 kN/sqm
Span = 2-Way
Panel Type = Two Adjacent Edges Discontinuous
Load Combination = 1.5 DL + 1.5 LL

Design  Moments:

file:///C:/Users/HP/AppData/Local/Temp/tmp94AD.tmp 9/24/2020
Page 3 of 5

Short Span Positive Moment At Midspan -


Moment Coefficient = 0.050
BM = 4.425 kNm
Mu = 1.5 X BM = 6.638 kNm
Area Of Reinforcement Required
= 152.000 sqmm/m
(Mu)
Area Of Reinforcement Provided for
= 251.000 sqmm/m
Crack Width
Reinforcement Provided = T8 @ 200 C/C
= 251.000 sqmm/m
Short Span Negative Moment At Continuous Support -
Moment Coefficient = 0.067
BM = 5.901 kNm
Mu = 1.5 X BM = 8.851 kNm
Area Of Reinforcement Required
= 200.000 sqmm/m
(Mu)
Area Of Reinforcement Provided for
= 251.000 sqmm/m
Crack Width
Reinforcement Provided = T8 @ 200 C/C
= 251.000 sqmm/m
Long Span Positive Moment At Midspan -
Moment Coefficient = 0.034
BM = 2.990 kNm
Mu = 1.5 X BM = 4.486 kNm
Area Of Reinforcement Required
= 152.000 sqmm/m
(Mu)
Area Of Reinforcement Provided for
= 251.000 sqmm/m
Crack Width
Reinforcement Provided = T8 @ 200 C/C
= 251.000 sqmm/m
Long Span Negative Moment At Continuous Support -
Moment Coefficient = 0.045
BM = 3.987 kNm
Mu = 1.5 X BM = 5.981 kNm
Area Of Reinforcement Required
= 152.000 sqmm/m
(Mu)
Area Of Reinforcement Provided for
= 251.000 sqmm/m
Crack Width
Reinforcement Provided = T8 @ 200 C/C
= 251.000 sqmm/m
Distribution Reinforcement @ 0.12% -
Area Of Reinforcement Required = 128.400 sqmm/m
Reinforcement Provided = T8 @ 200 C/C
= 251.000 sqmm/m

file:///C:/Users/HP/AppData/Local/Temp/tmp94AD.tmp 9/24/2020
Page 4 of 5

Shear Check :
Along Short Span
Shear Coefficient(Lx), SF1 = 0.492
V = SF1 x TL x Lx = 11.917 kN
Vu = 1.5 X V = 17.875 kN
Shear Stress, Tv = 0.167 N/sqmm
Nominal Shear Stress, Tc = 0.350 N/sqmm
Modification Factor 'K' = 1.300
K x Tc = 0.455
> 0.167 Slab Is Safe In Shear
Along Long Span
Shear Coefficient(Ly), SF2 = 0.400
V = SF2 x TL x Lx = 9.692 kN
Vu = 1.5 X V = 14.538 kN
Shear Stress, Tv = 0.150 N/sqmm
Nominal Shear Stress, Tc = 0.350 N/sqmm
Modification Factor 'K' = 1.300
K x Tc = 0.455
> 0.150 Slab Is Safe In Shear
Deflection Check:
Basic Span To Depth Ratio = 26
Span Correction Factor = 1.000
Tensile Steel Factor = 2.512
Compression Steel Factor = 1.000
Flange Correction Factor = 1.000
Max Span To Depth Ratio = 26.00 x 1.00 x 2.51 x 1.00 x 1.00
= 65.323
Lx/d = 33.925
< 65.323 Slab Is Safe In Deflection

Crack Width and Stress Check as per IS 456


Bottom Along L Bottom Along B Top Along L Top Along B
BM (Unfactored) (kNm) 4.4254 2.9905 5.9005 3.9873
Cmin (mm) 15 15 15 15
Reinforcement T8@200 T8@200 T8@200 T8@200
Ast Prv (sqmm/m) 251 251 251 251
Xact (mm) 23.7608 23.7608 23.7608 23.7608
Icr (mm^4) 28251327.3582 28251327.3582 28251327.3582 28251327.3582
acr (mm) 97.789 97.789 97.789 97.789
Check for Stress in Steel
       Fst (N/sqmm) 175.941 118.8933 234.588 158.5244
       FstPerm (N/sqmm) 275 275 275 275
Check for Stress in Concrete
       Fc (N/sqmm) 3.722 2.5152 4.9627 3.3535
       FcPerm (N/sqmm) 7 7 7 7
Crack Width Check

file:///C:/Users/HP/AppData/Local/Temp/tmp94AD.tmp 9/24/2020
Page 5 of 5

       Epsilon-deff, E1 0.0011 0.0007 0.0014 0.001


       Epsilon-m, Em 0.0002 -0.0001 0.0006 0.0001
       Wcr (mm) 0.0269 0 0.0674 0.0149
       WcrPerm (mm) 0.2 0.2 0.2 0.2