0% found this document useful (0 votes)
216 views

Configuring GRBL v0.9 GRBL - GRBL Wiki GitHub

This document provides instructions for configuring settings in Grbl v0.9, an open-source CNC controller software. It describes how to connect to Grbl and view the help messages and current settings. Each Grbl setting is explained, such as what it controls and example values. The document also explains how to save new setting values using the $x=val command and invert pins using bitmask values.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
216 views

Configuring GRBL v0.9 GRBL - GRBL Wiki GitHub

This document provides instructions for configuring settings in Grbl v0.9, an open-source CNC controller software. It describes how to connect to Grbl and view the help messages and current settings. Each Grbl setting is explained, such as what it controls and example values. The document also explains how to save new setting values using the $x=val command and invert pins using bitmask values.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 17

11/3/2019 Configuring Grbl v0.

9 · grbl/grbl Wiki · GitHub

Configuring Grbl v0.9


Jump to bottom
Charles Van Noland edited this page on 14 Dec 2017 · 30 revisions

Grbl v1.1 has been released at our new site! The old site will
eventually be phased out.

Quick-Links:

Getting Started
Grbl Settings
Grbl's Settings and What They Mean
Grbl's Other  $  Commands
Real-Time Commands

Getting Started
First, connect to Grbl using the serial terminal of your choice.

Set the baud rate to 115200 as 8-N-1 (8-bits, no parity, and 1-stop bit.)

Once connected you should get the Grbl-prompt, which looks like this:

Grbl 0.9i ['$' for help]

Type $ and press enter to have Grbl print a help message. You should not see any local echo of the $
and enter. Grbl should respond with:

$$ (view Grbl settings)


$# (view # parameters)
$G (view parser state)
$I (view build info)
$N (view startup blocks)
$x=value (save Grbl setting)
$Nx=line (save startup block)

https://github.com/grbl/grbl/wiki/Configuring-Grbl-v0.9 1/17
11/3/2019 Configuring Grbl v0.9 · grbl/grbl Wiki · GitHub

$C (check gcode mode)


$X (kill alarm lock)
$H (run homing cycle)
~ (cycle start)
! (feed hold)
? (current status)
ctrl-x (reset Grbl)

The ‘$’-commands are Grbl system commands used to tweak the settings, view or change Grbl's states
and running modes, and start a homing cycle. The last four non-'$' commands are realtime control
commands that can be sent at anytime, no matter what Grbl is doing. These either immediately
change Grbl's running behavior or immediately print a report of the important realtime data like
current position (aka DRO).

Grbl Settings

$$ - View Grbl settings

To view the settings, type  $$  and press enter after connecting to Grbl. Grbl should respond with a list
of the current system settings, as shown in the example below. All of these settings are persistent and
kept in EEPROM, so if you power down, these will be loaded back up the next time you power up your
Arduino.

$0=10 (step pulse, usec)


$1=25 (step idle delay, msec)
$2=0 (step port invert mask:00000000)
$3=6 (dir port invert mask:00000110)
$4=0 (step enable invert, bool)
$5=0 (limit pins invert, bool)
$6=0 (probe pin invert, bool)
$10=3 (status report mask:00000011)
$11=0.020 (junction deviation, mm)
$12=0.002 (arc tolerance, mm)
$13=0 (report inches, bool)
$20=0 (soft limits, bool)
$21=0 (hard limits, bool)
$22=0 (homing cycle, bool)
$23=1 (homing dir invert mask:00000001)
$24=50.000 (homing feed, mm/min)
$25=635.000 (homing seek, mm/min)
$26=250 (homing debounce, msec)
$27=1.000 (homing pull-off, mm)
$100=314.961 (x, step/mm)
$101=314.961 (y, step/mm)

https://github.com/grbl/grbl/wiki/Configuring-Grbl-v0.9 2/17
11/3/2019 Configuring Grbl v0.9 · grbl/grbl Wiki · GitHub

$102=314.961 (z, step/mm)


$110=635.000 (x max rate, mm/min)
$111=635.000 (y max rate, mm/min)
$112=635.000 (z max rate, mm/min)
$120=50.000 (x accel, mm/sec^2)
$121=50.000 (y accel, mm/sec^2)
$122=50.000 (z accel, mm/sec^2)
$130=225.000 (x max travel, mm)
$131=125.000 (y max travel, mm)
$132=170.000 (z max travel, mm)

$x=val - Save Grbl setting

The  $x=val  command saves or alters a Grbl setting, which can be done manually by sending this
command when connected to Grbl through a serial terminal program, but most Grbl GUIs will do this
for you as a user-friendly feature.

To manually change e.g. the microseconds step pulse option to 10us you would type this, followed by
an enter:

$0=10

If everything went well, Grbl will respond with an 'ok' and this setting is stored in EEPROM and will be
retained forever or until you change them. You can check if Grbl has received and stored your setting
correctly by typing  $$  to view the system settings again.

Grbl's  $x=val  settings and what they mean

NOTE: Settings numbering has changed since v0.8c for future-proofing purposes.

$0 – Step pulse, microseconds

Stepper drivers are rated for a certain minimum step pulse length. Check the data sheet or just try
some numbers. You want the shortest pulses the stepper drivers can reliably recognize. If the pulses
are too long, you might run into trouble when running the system at very high feed and pulse rates,
because the step pulses can begin to overlap each other. We recommend something around 10
microseconds, which is the default value.

$1 - Step idle delay, msec

https://github.com/grbl/grbl/wiki/Configuring-Grbl-v0.9 3/17
11/3/2019 Configuring Grbl v0.9 · grbl/grbl Wiki · GitHub

Every time your steppers complete a motion and come to a stop, Grbl will delay disabling the steppers
by this value. OR, you can always keep your axes enabled (powered so as to hold position) by setting
this value to the maximum 255 milliseconds. Again, just to repeat, you can keep all axes always
enabled by setting  $1=255 .

The stepper idle lock time is the time length Grbl will keep the steppers locked before disabling.
Depending on the system, you can set this to zero and disable it. On others, you may need 25-50
milliseconds to make sure your axes come to a complete stop before disabling. This is to help account
for machine motors that do not like to be left on for long periods of time without doing something.
Also, keep in mind that some stepper drivers don't remember which micro step they stopped on, so
when you re-enable, you may witness some 'lost' steps due to this. In this case, just keep your steppers
enabled via  $1=255 .

$2 – Step port invert mask:binary

This setting inverts the step pulse signal. By default, a step signal starts at normal-low and goes high
upon a step pulse event. After a step pulse time set by  $0 , the pin resets to low, until the next step
pulse event. When inverted, the step pulse behavior switches from normal-high, to low during the
pulse, and back to high. Most users will not need to use this setting, but this can be useful for certain
CNC-stepper drivers that have peculiar requirements. For example, an artificial delay between the
direction pin and step pulse can be created by inverting the step pin.

This invert mask setting is a value which stores the axes to invert as bit flags. You really don't need to
completely understand how it works. You simply need to enter the settings value for the axes you
want to invert. For example, if you want to invert the X and Z axes, you'd send  $2=5  to Grbl and the
setting should now read  $2=5 (step port invert mask:00000101) .

Setting Value Mask Invert X Invert Y Invert Z

0 00000000 N N N

1 00000001 Y N N

2 00000010 N Y N

3 00000011 Y Y N

4 00000100 N N Y

5 00000101 Y N Y

6 00000110 N Y Y

7 00000111 Y Y Y

$3 – Direction port invert mask:binary

https://github.com/grbl/grbl/wiki/Configuring-Grbl-v0.9 4/17
11/3/2019 Configuring Grbl v0.9 · grbl/grbl Wiki · GitHub

This setting inverts the direction signal for each axis. By default, Grbl assumes that the axes move in a
positive direction when the direction pin signal is low, and a negative direction when the pin is high.
Often, axes don't move this way with some machines. This setting will invert the direction pin signal for
those axes that move the opposite way.

This invert mask setting works exactly like the step port invert mask and stores which axes to invert as
bit flags. To configure this setting, you simply need to send the value for the axes you want to invert.
Use the table above. For example, if want to invert the Y axis direction only, you'd send  $3=2  to Grbl
and the setting should now read  $3=2 (dir port invert mask:00000010)

$4 - Step enable invert, bool

By default, the stepper enable pin is high to disable and low to enable. If your setup needs the
opposite, just invert the stepper enable pin by typing  $4=1 . Disable with  $4=0 . (May need a power
cycle to load the change.)

$5 - Limit pins invert, bool

By default, the limit pins are held normally-high with the Arduino's internal pull-up resistor. When a
limit pin is low, Grbl interprets this as triggered. For the opposite behavior, just invert the limit pins by
typing  $5=1 . Disable with  $5=0 . You may need a power cycle to load the change.

NOTE: If you invert your limit pins, you will need an external pull-down resistor wired in to all of the
limit pins to prevent overloading the pins with current and frying them.

$6 - Probe pin invert, bool

By default, the probe pin is held normally-high with the Arduino's internal pull-up resistor. When the
probe pin is low, Grbl interprets this as triggered. For the opposite behavior, just invert the probe pin
by typing  $6=1 . Disable with  $6=0 . You may need a power cycle to load the change.

$10 - Status report mask:binary

This setting determines what Grbl real-time data it reports back to the user when a '?' status report is
sent. By default, Grbl will send back its running state (can't be turned off), machine position, and work
position (machine position with coordinate offsets and other offsets applied). Three additional
reporting features are available that are useful for interfaces or users setting up their machines, which
include the serial RX buffer, planner block buffer usage, and limit pin states (as high or low, shown in
the order ZYX).

https://github.com/grbl/grbl/wiki/Configuring-Grbl-v0.9 5/17
11/3/2019 Configuring Grbl v0.9 · grbl/grbl Wiki · GitHub

To set them, use the table below to determine what data you'd like Grbl to send back. Select the
report types you'd like to see in the status reports and add their values together. This is the value you
use to send to Grbl. For example, if you need machine and work positions, add the values 1 and 2 and
send Grbl  $10=3  to set it. Or, if you need machine position only and limit pin state, add the values 1
and 16 and send Grbl  $10=17 .

In general, keep this real-time status data to a minimum, since it takes resources to print and send this
data back at a high rate. For example, limit pins reporting is generally only needed when users are
setting up their machine. Afterwards, it's recommended to disable it, as it isn't very useful once you've
got everything figured out.

Report Type Value

Machine Position 1

Work Position 2

Planner Buffer 4

RX Buffer 8

Limit Pins 16

$11 - Junction deviation, mm

Junction deviation is used by the acceleration manager to determine how fast it can move through line
segment junctions of a G-code program path. For example, if the G-code path has a sharp 10 degree
turn coming up and the machine is moving at full speed, this setting helps determine how much the
machine needs to slow down to safely go through the corner without losing steps.

How we calculate it is a bit complicated, but, in general, higher values gives faster motion through
corners, while increasing the risk of losing steps and positioning. Lower values makes the acceleration
manager more careful and will lead to careful and slower cornering. So if you run into problems where
your machine tries to take a corner too fast, decrease this value to make it slow down when entering
corners. If you want your machine to move faster through junctions, increase this value to speed it up.
For curious people, hit this link to read about Grbl's cornering algorithm, which accounts for both
velocity and junction angle with a very simple, efficient, and robust method.

$12 – Arc tolerance, mm

https://github.com/grbl/grbl/wiki/Configuring-Grbl-v0.9 6/17
11/3/2019 Configuring Grbl v0.9 · grbl/grbl Wiki · GitHub

Grbl renders G2/G3 circles, arcs, and helices by subdividing them into teeny tiny lines, such that the arc
tracing accuracy is never below this value. You will probably never need to adjust this setting,
since  0.002mm  is well below the accuracy of most all CNC machines. But if you find that your circles
are too crude or arc tracing is performing slowly, adjust this setting. Lower values give higher precision
but may lead to performance issues by overloading Grbl with too many tiny lines. Alternately, higher
values traces to a lower precision, but can speed up arc performance since Grbl has fewer lines to deal
with.

For the curious, arc tolerance is defined as the maximum perpendicular distance from a line segment
with its end points lying on the arc, aka a chord. With some basic geometry, we solve for the length of
the line segments to trace the arc that satisfies this setting. Modeling arcs in this way is great, because
the arc line segments automatically adjust and scale with length to ensure optimum arc tracing
performance, while never losing accuracy.

$13 - Report inches, bool

Grbl has a real-time positioning reporting feature to provide a user feedback on where the machine is
exactly at that time, as well as, parameters for coordinate offsets and probing. By default, it is set to
report in mm, but by sending a  $13=1  command, you send this boolean flag to true and these
reporting features will now report in inches.  $13=0  to set back to mm.

$20 - Soft limits, bool

Soft limits is a safety feature to help prevent your machine from traveling too far and beyond the
limits of travel, crashing or breaking something expensive. It works by knowing the maximum travel
limits for each axis and where Grbl is in machine coordinates. Whenever a new G-code motion is sent
to Grbl, it checks whether or not you accidentally have exceeded your machine space. If you do, Grbl
will issue an immediate feed hold wherever it is, shutdown the spindle and coolant, and then set the
system alarm indicating the problem. Machine position will be retained afterwards, since it's not due
to an immediate forced stop like hard limits.

NOTE: Soft limits requires homing to be enabled and accurate axis maximum travel settings, because
Grbl needs to know where it is.  $20=1  to enable, and  $20=0  to disable.

$21 - Hard limits, bool

Hard limit work basically the same as soft limits, but use physical switches instead. Basically you wire
up some switches (mechanical, magnetic, or optical) near the end of travel of each axes, or where ever
you feel that there might be trouble if your program moves too far to where it shouldn't. When the
switch triggers, it will immediately halt all motion, shutdown the coolant and spindle (if connected),
and go into alarm mode, which forces you to check your machine and reset everything.

https://github.com/grbl/grbl/wiki/Configuring-Grbl-v0.9 7/17
11/3/2019 Configuring Grbl v0.9 · grbl/grbl Wiki · GitHub

To use hard limits with Grbl, the limit pins are held high with an internal pull-up resistor, so all you
have to do is wire in a normally-open switch with the pin and ground and enable hard limits
with  $21=1 . (Disable with  $21=0 .) We strongly advise taking electric interference prevention
measures. If you want a limit for both ends of travel of one axes, just wire in two switches in parallel
with the pin and ground, so if either one of them trips, it triggers the hard limit.

Keep in mind, that a hard limit event is considered to be critical event, where steppers immediately
stop and will have likely have lost steps. Grbl doesn't have any feedback on position, so it can't
guarantee it has any idea where it is. So, if a hard limit is triggered, Grbl will go into an infinite loop
ALARM mode, giving you a chance to check your machine and forcing you to reset Grbl. Remember
it's a purely a safety feature.

$22 - Homing cycle, bool

Ahh, homing. For those just initiated into CNC, the homing cycle is used to accurately and precisely
locate a known and consistent position on a machine every time you start up your Grbl between
sessions. In other words, you know exactly where you are at any given time, every time. Say you start
machining something or are about to start the next step in a job and the power goes out, you re-start
Grbl and Grbl has no idea where it is. You're left with the task of figuring out where you are. If you
have homing, you always have the machine zero reference point to locate from, so all you have to do
is run the homing cycle and resume where you left off.

To set up the homing cycle for Grbl, you need to have limit switches in a fixed position that won't get
bumped or moved, or else your reference point gets messed up. Usually they are setup in the farthest
point in +x, +y, +z of each axes. Wire your limit switches in with the limit pins and ground, just like
with the hard limits, and enable homing. If you're curious, you can use your limit switches for both
hard limits AND homing. They play nice with each other.

By default, Grbl's homing cycle moves the Z-axis positive first to clear the workspace and then moves
both the X and Y-axes at the same time in the positive direction. To set up how your homing cycle
behaves, there are more Grbl settings down the page describing what they do (and compile-time
options as well.)

Also, one more thing to note, when homing is enabled. Grbl will lock out all G-code commands until
you perform a homing cycle. Meaning no axes motions, unless the lock is disabled ($X) but more on
that later. Most, if not all CNC controllers, do something similar, as it is mostly a safety feature to
prevent users from making a positioning mistake, which is very easy to do and be saddened when a
mistake ruins a part. If you find this annoying or find any weird bugs, please let us know and we'll try
to work on it so everyone is happy. :)

NOTE: Check out config.h for more homing options for advanced users. You can disable the homing
lockout at startup, configure which axes move first during a homing cycle and in what order, and
more.
https://github.com/grbl/grbl/wiki/Configuring-Grbl-v0.9 8/17
11/3/2019 Configuring Grbl v0.9 · grbl/grbl Wiki · GitHub

$23 - Homing dir invert mask, int:binary

By default, Grbl assumes your homing limit switches are in the positive direction, first moving the z-
axis positive, then the x-y axes positive before trying to precisely locate machine zero by going back
and forth slowly around the switch. If your machine has a limit switch in the negative direction, the
homing direction mask can invert the axes' direction. It works just like the step port invert and
direction port invert masks, where all you have to do is send the value in the table to indicate what
axes you want to invert and search for in the opposite direction.

$24 - Homing feed, mm/min

The homing cycle first searches for the limit switches at a higher seek rate, and after it finds them, it
moves at a slower feed rate to home into the precise location of machine zero. Homing feed rate is
that slower feed rate. Set this to whatever rate value that provides repeatable and precise machine
zero locating.

$25 - Homing seek, mm/min

Homing seek rate is the homing cycle search rate, or the rate at which it first tries to find the limit
switches. Adjust to whatever rate gets to the limit switches in a short enough time without crashing
into your limit switches if they come in too fast.

$26 - Homing debounce, ms

Whenever a switch triggers, some of them can have electrical/mechanical noise that actually 'bounce'
the signal high and low for a few milliseconds before settling in. To solve this, you need to debounce
the signal, either by hardware with some kind of signal conditioner or by software with a short delay to
let the signal finish bouncing. Grbl performs a short delay, only homing when locating machine zero.
Set this delay value to whatever your switch needs to get repeatable homing. In most cases, 5-25
milliseconds is fine.

$27 - Homing pull-off, mm

To play nice with the hard limits feature, where homing can share the same limit switches, the homing
cycle will move off all of the limit switches by this pull-off travel after it completes. In other words, it
helps to prevent accidental triggering of the hard limit after a homing cycle.

$100, $101 and $102 – [X,Y,Z] steps/mm

Grbl needs to know how far each step will take the tool in reality. To calculate steps/mm for an axis of
your machine you need to know:

The mm traveled per revolution of your stepper motor. This is dependent on your belt drive gears
or lead screw pitch.
https://github.com/grbl/grbl/wiki/Configuring-Grbl-v0.9 9/17
11/3/2019 Configuring Grbl v0.9 · grbl/grbl Wiki · GitHub

The full steps per revolution of your steppers (typically 200)


The microsteps per step of your controller (typically 1, 2, 4, 8, or 16). Tip: Using high microstep
values (e.g., 16) can reduce your stepper motor torque, so use the lowest that gives you the desired
axis resolution and comfortable running properties.

The steps/mm can then be calculated like this:  steps_per_mm =


(steps_per_revolution*microsteps)/mm_per_rev

Compute this value for every axis and write these settings to Grbl.

$110, $111 and $112 – [X,Y,Z] Max rate, mm/min

This sets the maximum rate each axis can move. Whenever Grbl plans a move, it checks whether or not
the move causes any one of these individual axes to exceed their max rate. If so, it'll slow down the
motion to ensure none of the axes exceed their max rate limits. This means that each axis has its own
independent speed, which is extremely useful for limiting the typically slower Z-axis.

The simplest way to determine these values is to test each axis one at a time by slowly increasing max
rate settings and moving it. For example, to test the X-axis, send Grbl something like  G0 X50  with
enough travel distance so that the axis accelerates to its max speed. You'll know you've hit the max
rate threshold when your steppers stall. It'll make a bit of noise, but shouldn't hurt your motors. Enter
a setting a 10-20% below this value, so you can account for wear, friction, and the mass of your
workpiece/tool. Then, repeat for your other axes.

NOTE: This max rate setting also sets the G0 seek rates.

$120, $121, $122 – [X,Y,Z] Acceleration, mm/sec^2

This sets the axes acceleration parameters in mm/second/second. Simplistically, a lower value makes
Grbl ease slower into motion, while a higher value yields tighter moves and reaches the desired
feedrates much quicker. Much like the max rate setting, each axis has its own acceleration value and
are independent of each other. This means that a multi-axis motion will only accelerate as quickly as
the lowest contributing axis can.

Again, like the max rate setting, the simplest way to determine the values for this setting is to
individually test each axis with slowly increasing values until the motor stalls. Then finalize your
acceleration setting with a value 10-20% below this absolute max value. This should account for wear,
friction, and mass inertia. We highly recommend that you dry test some G-code programs with your
new settings before committing to them. Sometimes the loading on your machine is different when
moving in all axes together.

$130, $131, $132 – [X,Y,Z] Max travel, mm

https://github.com/grbl/grbl/wiki/Configuring-Grbl-v0.9 10/17
11/3/2019 Configuring Grbl v0.9 · grbl/grbl Wiki · GitHub

This sets the maximum travel from end to end for each axis in mm. This is only useful if you have soft
limits (and homing) enabled, as this is only used by Grbl's soft limit feature to check if you have
exceeded your machine limits with a motion command.

Grbl's Other '$' Commands


The other  $  commands provide additional controls for the user, such as printing feedback on the
current G-code parser modal state or running the homing cycle. This section explains what these
commands are and how to use them.

$#  - View gcode parameters

G-code parameters store the coordinate offset values for G54-G59 work coordinates, G28/G30 pre-
defined positions, G92 coordinate offset, tool length offsets, and probing (not officially, but we added
here anyway). Most of these parameters are directly written to EEPROM anytime they are changed and
are persistent. Meaning that they will remain the same, regardless of power-down, until they are
explicitly changed. The non-persistent parameters, which will are not retained when reset or power-
cycled, are G92, G43.1 tool length offsets, and the G38.2 probing data.

G54-G59 work coordinates can be changed via the  G10 L2 Px  or  G10 L20 Px  command defined by
the NIST gcode standard and the EMC2 (linuxcnc.org) standard. G28/G30 pre-defined positions can be
changed via the  G28.1  and the  G30.1  commands, respectively.

When  $#  is called, Grbl will respond with the stored offsets from machine coordinates for each
system as follows.  TLO  denotes tool length offset, and  PRB  denotes the coordinates of the last
probing cycle.

[G54:4.000,0.000,0.000]
[G55:4.000,6.000,7.000]
[G56:0.000,0.000,0.000]
[G57:0.000,0.000,0.000]
[G58:0.000,0.000,0.000]
[G59:0.000,0.000,0.000]
[G28:1.000,2.000,0.000]
[G30:4.000,6.000,0.000]
[G92:0.000,0.000,0.000]
[TLO:0.000,0.000,0.000]
[PRB:0.000,0.000,0.000]

$G  - View gcode parser state

https://github.com/grbl/grbl/wiki/Configuring-Grbl-v0.9 11/17
11/3/2019 Configuring Grbl v0.9 · grbl/grbl Wiki · GitHub

This command prints all of the active gcode modes in Grbl's G-code parser. When sending this
command to Grbl, it will reply with something like:

[G0 G54 G17 G21 G90 G94 M0 M5 M9 T0 S0.0 F500.0]

These active modes determine how the next G-code block or command will be interpreted by Grbl's
G-code parser. For those new to G-code and CNC machining, modes sets the parser into a particular
state so you don't have to constantly tell the parser how to parse it. These modes are organized into
sets called "modal groups" that cannot be logically active at the same time. For example, the units
modal group sets whether your G-code program is interpreted in inches or in millimeters.

A short list of the modal groups, supported by Grbl, is shown below, but more complete and detailed
descriptions can be found at LinuxCNC's website. The G-code commands in boldindicate the default
modes upon powering-up Grbl or resetting it.

Modal Group Meaning Member Words

Motion Mode G0, G1, G2, G3, G38.2, G38.3, G38.4, G38.5, G80

Coordinate System Select G54, G55, G56, G57, G58, G59

Plane Select G17, G18, G19

Distance Mode G90, G91

Arc IJK Distance Mode G91.1

Feed Rate Mode G93, G94

Units Mode G20, G21

Cutter Radius Compensation G40

Tool Length Offset G43.1, G49

Program Mode M0, M1, M2, M30

Spindle State M3, M4, M5

Coolant State M7, M8, M9

In addition to the G-code parser modes, Grbl will report the active  T  tool number,  S spindle speed,
and  F  feed rate, which all default to 0 upon a reset. For those that are curious, these don't quite fit
into nice modal groups, but are just as important for determining the parser state.

$I  - View build info

https://github.com/grbl/grbl/wiki/Configuring-Grbl-v0.9 12/17
11/3/2019 Configuring Grbl v0.9 · grbl/grbl Wiki · GitHub

This prints feedback to the user the Grbl version and source code build date. Optionally,  $I can also
store a short string to help identify which CNC machine you are communicating with, if you have more
than machine using Grbl. To set this string, send Grbl  $I=xxx , where  xxx  is your customization string
that is less than 80 characters. The next time you query Grbl with a  $I  view build info, Grbl will print
this string after the version and build date.

$N - View startup blocks

$Nx  are the startup blocks that Grbl runs every time you power on Grbl or reset Grbl. In other words,
a startup block is a line of G-code that you can have Grbl auto-magically run to set your G-code modal
defaults, or anything else you need Grbl to do everytime you start up your machine. Grbl can store two
blocks of G-code as a system default.

So, when connected to Grbl, type  $N  and then enter. Grbl should respond with something short like:

$N0=
$N1=
ok

Not much to go on, but this just means that there is no G-code block stored in line  $N0  for Grbl to
run upon startup.  $N1  is the next line to be run.

$Nx=line - Save startup block

IMPORTANT: Be very careful when storing any motion (G0/1,G2/3,G28/30) commands in the
startup blocks. These motion commands will run everytime you reset or power up Grbl, so if you
have an emergency situation and have to e-stop and reset, a startup block move can and will likely
make things worse quickly. Also, do not place any commands that save data to EEPROM, such as
G10/G28.1/G30.1. This will cause Grbl to constantly re-write this data upon every startup and reset,
which will eventually wear out your Arduino's EEPROM.

Typical usage for a startup block is simply to set your preferred modal states, such as G20 inches
mode, always default to a different work coordinate system, or, to provide a way for a user to run
some user-written unique feature that they need for their crazy project.

To set a startup block, type  $N0=  followed by a valid G-code block and an enter. Grbl will run the
block to check if it's valid and then reply with an  ok  or an  error:  to tell you if it's successful or
something went wrong. If there is an error, Grbl will not save it.

For example, say that you want to use your first startup block  $N0  to set your G-code parser modes
like G54 work coordinate, G20 inches mode, G17 XY-plane. You would type  $N0=G20 G54 G17  with an
enter and you should see an 'ok' response. You can then check if it got stored by typing  $N  and you
should now see a response like  $N0=G20G54G17 .
https://github.com/grbl/grbl/wiki/Configuring-Grbl-v0.9 13/17
11/3/2019 Configuring Grbl v0.9 · grbl/grbl Wiki · GitHub

Once you have a startup block stored in Grbl's EEPROM, everytime you startup or reset you will see
your startup block printed back to you and a response from Grbl to indicate if it ran okay. So for the
previous example, you'll see:

Grbl 0.9i ['$' for help]


G20G54G17ok

If you have multiple G-code startup blocks, they will print back to you in order upon every startup. And
if you'd like to clear one of the startup blocks, (e.g., block 0) type  $N0=  without anything following the
equal sign.

Also, if you have homing enabled, the startup blocks will execute immediately after the homing cycle,
not at startup.

$C  - Check gcode mode

This toggles the Grbl's gcode parser to take all incoming blocks and process them completely, as it
would in normal operation, but it does not move any of the axes, ignores dwells, and powers off the
spindle and coolant. This is intended as a way to provide the user a way to check how their new G-
code program fares with Grbl's parser and monitor for any errors (and checks for soft limit violations, if
enabled).

When toggled off, Grbl will perform an automatic soft-reset (^X). This is for two purposes. It simplifies
the code management a bit. But, it also prevents users from starting a job when their G-code modes
are not what they think they are. A system reset always gives the user a fresh, consistent start.

$X  - Kill alarm lock

Grbl's alarm mode is a state when something has gone critically wrong, such as a hard limit or an
abort during a cycle, or if Grbl doesn't know its position. By default, if you have homing enabled and
power-up the Arduino, Grbl enters the alarm state, because it does not know its position. The alarm
mode will lock all G-code commands until the '$H' homing cycle has been performed. Or if a user
needs to override the alarm lock to move their axes off their limit switches, for example, '$X' kill alarm
lock will override the locks and allow G-code functions to work again.

But, tread carefully!! This should only be used in emergency situations. The position has likely been
lost, and Grbl may not be where you think it is. So, it's advised to use G91 incremental mode to make
short moves. Then, perform a homing cycle or reset immediately afterwards.

$H  - Run homing cycle

https://github.com/grbl/grbl/wiki/Configuring-Grbl-v0.9 14/17
11/3/2019 Configuring Grbl v0.9 · grbl/grbl Wiki · GitHub

This command is the only way to perform the homing cycle in Grbl. Some other motion controllers
designate a special G-code command to run a homing cycle, but this is incorrect according to the G-
code standards. Homing is a completely separate command handled by the controller.

TIP: After running a homing cycle, rather jogging manually all the time to a position in the middle of
your workspace volume. You can set a G28 or G30 pre-defined position to be your post-homing
position, closer to where you'll be machining. To set these, you'll first need to jog your machine to
where you would want it to move to after homing. Type G28.1 (or G30.1) to have Grbl store that
position. So then after '$H' homing, you could just enter 'G28' (or 'G30') and it'll move there auto-
magically. In general, I would just move the XY axis to the center and leave the Z-axis up. This ensures
that there isn't a chance the tool in the spindle will interfere and that it doesn't catch on anything.

$RST=$ ,  $RST=# , and  $RST=* - Restore Grbl settings and data to defaults

These commands are not listed in the main Grbl  $  help message, but are available to allow users to
restore parts of or all of Grbl's EEPROM data. Note: Grbl will automatically reset after executing one of
these commands to ensure the system is initialized correctly.

$RST=$  : Erases and restores the  $$  Grbl settings back to defaults, which is defined by the
default settings file used when compiling Grbl. Often OEMs will build their Grbl firmwares with
their machine-specific recommended settings. This provides users and OEMs a quick way to get
back to square-one, if something went awry or if a user wants to start over.
$RST=#  : Erases and zeros all G54-G59 work coordinate offsets and G28/30 positions stored in
EEPROM. These are generally the values seen in the  $#  parameters printout. This provides an
easy way to clear these without having to do it manually for each set with a  G20
L2/20  or  G28.1/30.1  command.

$RST=*  : This clears and restores all of the EEPROM data used by Grbl. This
includes  $$ settings,  $#  parameters,  $N  startup lines, and  $I  build info string. Note that this
doesn't wipe the entire EEPROM, only the data areas Grbl uses. To do a complete wipe, please use
the Arduino IDE's EEPROM clear example project.

Real-Time Commands:  ~, !, ?, and Ctrl-X

The last four of Grbl's commands are real-time commands. This means that they can be sent at
anytime, anywhere, and Grbl will immediately respond, no matter what it's doing. For those that are
curious, these are special characters that are 'picked-off' from the incoming serial stream and will tell
Grbl to execute them, usually within a few milliseconds.

~  - Cycle start

https://github.com/grbl/grbl/wiki/Configuring-Grbl-v0.9 15/17
11/3/2019 Configuring Grbl v0.9 · grbl/grbl Wiki · GitHub

This is the cycle start or resume command that can be issued at any time, as it is a real-time command.
When Grbl has motions queued in its buffer and is ready to go, the  ~  cycle start command will start
executing the buffer and Grbl will begin moving the axes. However, by default, auto-cycle start is
enabled, so new users will not need this command unless a feed hold is performed. When a feed hold
is executed, cycle start will resume the program. Cycle start will only be effective when there are
motions in the buffer ready to go and will not work with any other process like homing.

!  - Feed hold

The feed hold command will bring the active cycle to a stop via a controlled deceleration, so as not to
lose position. It is also real-time and may be activated at any time. Once finished or paused, Grbl will
wait until a cycle start command is issued to resume the program. Feed hold can only pause a cycle
and will not affect homing or any other process.

If you need to stop a cycle mid-program and can't afford losing position, perform a feed hold to have
Grbl bring everything to a controlled stop. Once finished, you can then issue a reset. Always try to
execute a feed hold whenever the machine is running before hitting reset, except of course if there is
some emergency situation.

?  - Current status

The  ?  command immediately returns Grbl's active state and the real-time current position, both in
machine coordinates and work coordinates. Optionally, you can also have Grbl respond back with the
RX serial buffer and planner buffer usage via the status report mask setting. The  ?  command may be
sent at any time and works asynchronously with all other processes that Grbl is doing. The  $13  Grbl
setting determines whether it reports millimeters or inches. When  ?  is pressed, Grbl will immediately
reply with something like the following:

<Idle,MPos:5.529,0.560,7.000,WPos:1.529,-5.440,-0.000>

The active states Grbl can be in are: Idle, Run, Hold, Door, Home, Alarm, Check

Idle: All systems are go, no motions queued, and it's ready for anything.
Run: Indicates a cycle is running.
Hold: A feed hold is in process of executing, or slowing down to a stop. After the hold is
complete, Grbl will remain in Hold and wait for a cycle start to resume the program.
Door: (New in v0.9i) This compile-option causes Grbl to feed hold, shut-down the spindle and
coolant, and wait until the door switch has been closed and the user has issued a cycle start.
Useful for OEM that need safety doors.
Home: In the middle of a homing cycle. NOTE: Positions are not updated live during the homing
cycle, but they'll be set to the home position once done.
https://github.com/grbl/grbl/wiki/Configuring-Grbl-v0.9 16/17
11/3/2019 Configuring Grbl v0.9 · grbl/grbl Wiki · GitHub

Alarm: This indicates something has gone wrong or Grbl doesn't know its position. This state
locks out all G-code commands, but allows you to interact with Grbl's settings if you need to. '$X'
kill alarm lock releases this state and puts Grbl in the Idle state, which will let you move things
again. As said before, be cautious of what you are doing after an alarm.
Check: Grbl is in check G-code mode. It will process and respond to all G-code commands, but
not motion or turn on anything. Once toggled off with another '$C' command, Grbl will reset
itself.

Ctrl-x  - Reset Grbl

This is Grbl's soft reset command. It's real-time and can be sent at any time. As the name implies, it
resets Grbl, but in a controlled way, retains your machine position, and all is done without powering
down your Arduino. The only times a soft-reset could lose position is when problems arise and the
steppers were killed while they were moving. If so, it will report if Grbl's tracking of the machine
position has been lost. This is because an uncontrolled deceleration can lead to lost steps, and Grbl
has no feedback to how much it lost (this is the problem with steppers in general). Otherwise, Grbl will
just re-initialize, run the startup lines, and continue on its merry way.

Please note that it's recommended to do a soft-reset before starting a job. This guarantees that there
aren't any G-code modes active that from playing around or setting up your machine before running
the job. So, your machine will always starts fresh and consistently, and your machine does what you
expect it to.

https://github.com/grbl/grbl/wiki/Configuring-Grbl-v0.9 17/17

You might also like