VariTrans A 26000
The specialist for ±10 V and ±20 mA.
With calibrated range selection and broad-range power supply.
The Housing
At a width of just 12.5 mm, the mod-
ular housing with pluggable screw
terminals allows for simple and fast as-
sembly and pre-wiring of enclosures.
Housings with fixed screw terminals
are also available for extremely high
mechanical loads. The easy-to-open
housing allows for simple configura-
tion of the input and output ranges
and provides good protection against
contact and unintentional adjustment.
The Advantages
Analog transmission of the measure-
ment signal with transformer-based
isolation and the digitally controlled
range selection guarantee excellent
signal transmission:
– Gain error only 0.1 %
– Excellent pulse formation
– Extremely low residual ripple
The Task
Transmission and conversion of bipo- – Maximum long-term stability and
lar standard 0 ... ±20 mA and 0 ... ±10 V reliability
signals frequently used in industry, The Technology
e.g., for speed monitoring with tacho- A microcontroller monitors the control
generators. element settings and controls the
The Problems calibrated range selection. Interfer-
Measuring errors occur due to poten- ence with the signal transmission –
tial differences when bipolar measur- due to contact resistance in the range
ing signals are transmitted. In addi- switch, for example – is ruled out in
tion, the signal matching previously this manner.
required calibration of the isolators.
Thanks to the VariPower power
The Solution supplies, the devices can be used
Knick provides a tailor-made solution. internationally with virtually all supply
Thanks to the calibrated selection voltages. The extremely low power
of the input and output parameters consumption and the related minimal
using DIP switches, VariTrans A 26000 self-heating significantly increase
universal signal conditioners can be reliability. The result: a 5-year warranty.
used without complicated readjust-
ment. The broad-range power supply
for all common supply voltages from
20 to 253 V AC/DC offers maximum
flexibility.
22 | VariTrans A 26000
VariTrans A 26000
VariTrans A 26000 | 23
ProLine
Interface Technology Universal Isolated Signal Conditioners
Product Line
Power supply
20 … 253 V AC/DC
Specifications
Input data
Inputs 0 … ±20 mA terminal selectable / switchable (default setting ±10 V)
0 … ±10 V or fixed setting (see product line)
Input resistance Current input voltage drop approx. 250 mV at 20 mA
Voltage input approx. 1 Mohm
Overload capacity Current input ≤300 mA
Voltage input voltage limiting to 30 V by suppressor diode,
max. allowable continuous current: 30 mA
Output data
Outputs 0 … ±20 mA terminal selectable / switchable (default setting ±10 V)
0 … ±10 V or fixed setting (see product line)
Load With output current ≤ 10 V (500 ohms at 20 mA)
With output voltage ≤ 10 mA (1 kohm at 10 V)1)
Offset 20 µA or 10 mV
Residual ripple < 10 mVrms
Transmission behavior
Gain error < 0.1 % meas.val. (DC)
Cutoff frequency > 5 kHz, –3 dB
Temperature coefficient2) 0.0075 %/K full scale (reference temp. 23 °C)
Response time T90 Approx. 140 µs
24 | VariTrans A 26000
VariTrans A 26000
Specifications (continued)
Power supply
Power supply 20 … 253 V AC/DC AC 48 … 62 Hz, approx. 2 VA
DC approx. 0.9 W
Isolation
Galvanic isolation 3-port isolation between input, output, and power supply
Test voltage 4 kV AC input against output against power supply
Working voltage (basic insulation) 1000 V AC/DC with overvoltage category II and pollution degree 2 according to EN 61010-1.
For applications with high working voltages, take measures to prevent accidental contact
and make sure that there is sufficient distance or insulation between adjacent devices.
Protection against electric shock Protective separation to EN 61140 by reinforced insulation according to EN 61010-1.
Working voltages up to 300 V AC/DC across input and output and power supply with overvoltage
category II and pollution degree 2.
For applications with high working voltages, take measures to prevent accidental contact
and make sure that there is sufficient distance or insulation between adjacent devices.
Further data
MTBF4) Approx. 91 years
Ambient temperature Operation: –10 … +70 °C
Transport and storage: –40 … +85 °C
Ambient conditions Indoor use5) ; relative humidity 5 … 95 %, no condensation;
max. altitude 2000 m (air pressure: 790 …1060 hPa) 6)
Design Modular housing, 12.5 mm wide, see dimension drawings for further measurements,
pluggable screw terminals: Type H1; fixed screw terminals: Type F1
Connection: pluggable screw terminals H1; fixed screw terminals F1
Conductor cross section max. 2.5 mm2;
Multi-wire connection max. 1 mm2 (two wires with equal diameters)
VariTrans A 26000 | 25
ProLine
Interface Technology Universal Isolated Signal Conditioners
Block Diagram
+
Voltage C 1 nF
input Z 30 V +
- C 1 nF Z 18 V
Output
-
Current C 1 nF -
input
+
Typical Applications
Potential isolation
Power supply
Signal conversion
for converting voltage signals to current signals, e.g., for interference-free
signal transmission over long distances
Power supply
26 | VariTrans A 26000
VariTrans A 26000
12.5 111
Plug-
gable
99
terminals
terminals
All dimensions in mm
VariTrans A 26000 | 27