0% found this document useful (0 votes)
152 views

2 Phase Relief Calculations Spreadsheet: Basis General Data

This spreadsheet calculates relief parameters for a two-phase relief scenario based on API RP 520 Part I Appendix D. It contains input values such as set pressure, relief temperature, densities, and flow rates. The calculations determine the critical flow pressure, mass flux, and required relief valve area. The results indicate the required area is 32.32 in2 and recommend installing multiple pressure safety valves.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
152 views

2 Phase Relief Calculations Spreadsheet: Basis General Data

This spreadsheet calculates relief parameters for a two-phase relief scenario based on API RP 520 Part I Appendix D. It contains input values such as set pressure, relief temperature, densities, and flow rates. The calculations determine the critical flow pressure, mass flux, and required relief valve area. The results indicate the required area is 32.32 in2 and recommend installing multiple pressure safety valves.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 1

2 Phase Relief Calculations Spreadsheet

REV. No. REV. DATE MADE BY CHKD. BY REV. No. REV. DATE MADE BY CHKD. BY

BASIS
This spreadsheet tool is based on API RP 520 Part I Appendix D

GENERAL DATA
Scenario Two Phase
1 - Flashing EQUIPMENT NUMBER
PSV TAG NUMBER Vapor
Multicomponent Yes 1 PSV TYPE 1
Conventional

Boiling Point Range 2F


>150

INPUTS

PSV Set Pressure, P 60 psig Thermodynamic Critical Pressure 800 psia


Allowable Overpressure 10 % Thermodynamic Critical Temperature 600 R
Relief Temperature, T 200 F Reduced Pressure, Pr 0.093 Liquid
Relief Rate, W 477430 lb/hr Reduced Temperature, Tr 0.783
Vapor Relief Rate at PSV Inlet, Wv 100000 lb/hr Coefficient of Discharge, Kd 1
Two Phase Density at PSV Inlet, Rho 3.209 lb/ft3 Backpressure Correction Factor, Kb 1
Vapor Density at PSV Inlet, Rho_v 10 lb/ft3 Density at 90% Inlet Pressure, Rho9 2.7555800496 <150 F
Liquid Density at PSV Inlet, Rho_l 55 lb/ft3 Saturation Pressure, Ps NA psia
Vapor Specific Enthalpy, hv 5 Btu/lb Downstream Backpressure, Pa 15 psia
Liquid Specific Enthalpy, hl Btu/lb
Liquid Specific Heat at PSV Inlet, Cp 1 Btu/lb.R
Vapor Specific Heat Ratio, k 1
###

Calculation

Calculated omega Parameter (w) 1.481

For two phase flow at inlet

Calculated hc 0.656 Calculated Mass Flux 590.88 lb/s.ft2

Critical flow pressure 52.96 psia Critical

For subcooled liquid flow at inlet

Calculated hst NA Calculated Mass Flux NA lb/s.ft2

Subcooling Region NA

Crit. Pres. Ratio (hc) (Fig. D3, App. D, API 520)

Critical flow pressure NA psia

Flow type NA

Results

Calculated Required Area of the PRV 32.32 in2

Orifice Designation Install Multiple PSV

Selected Orifice Area of PRV NA in2