Nautilus 85: Product Specifications
Nautilus 85: Product Specifications
Nautilus 85
Single-Channel Temperature Data Logger (Max 85°C)
The Nautilus 85 is a durable, robust data logger that can monitor temperature in a variety of applications but
is particularly well suited for the food and beverage, biomedical, pharmaceutical, and industries with hostile
or “wet” environments (i.e. wastewater treatment plant). Housed in a stainless steel or aluminum casing, it
can withstand virtually any environment and with an operating pressure range of up to 2,000 PSI, it is ideal
for monitoring temperature in any type of water including oceans, ponds, rivers, streams and wastewater.
APPLICATIONS
Record temperature of food products and other perishable goods; useful in the storage and transportation of
food, the medical and pharmaceutical industries, agricultural, ocean and pond studies, environmental stud-
ies, process monitoring, and hostile environment monitoring.
GENERAL SPECIFICATIONS
Size: 18mm x 127mm (0.71” x 5.00”)
Weight: Aluminum 51 g (1.8 oz); Stainless Steel 112 g (4 oz)
Case Material: Anodized Aluminum or Stainless Steel
Battery: 3.6 volt Lithium, 0.95 Amp-Hour
Resolution: 8-bit (1 part in 256)
Mounting: Locking hole on cap
Clock Accuracy: ± 2 seconds per day
Sampling Methods: Continuous (First-in First-out), Stop When Full, Delay Start, or Spot & Average
Operating Limits: -40°C to 85°C (-40°F to 185°F) and waterproof
Operating Pressure: Up to 2,000 PSI
PC Requirements: Windows PC with at least one free USB or serial port (depending on interface)
Software Requirements: TrendReader® 2 - Preferred (Compatible with Windows 2000 SP4, XP SP1 and
Vista 32 bit) or TrendReader® Express
Memory Size: 32 KB (capable of storing up to 244,800 readings with data compression enabled)
Sampling Rates: User selectable rates from 8 seconds to 34 minutes (readings stored to memory
can be spot or averaged over the sample interval, except for the 8 second interval)
Number of Channels: One (one channel for ambient temperature)
SENSOR SPECIFICATIONS
Temperature Sensor Type: NTC Thermistor - 10,000 Ohms @ 25°C (77°F)
Range: -40°C to 85°C (-40°F to 185°F)
Accuracy: ±0.2°C over the range of 0°C to 70°C (± 0.3°F over the range of 32°F to 158°F)
Resolution: 0.4°C (0.7°F) @ 25°C; better than 1°C (1.8°F) between -25°C and 70°C
(-13°F and 158°F); better than 2.0°C (3.6°F) between -40°C and -25°C
(-40°F and -13°F)
ORDERING INFORMATION
Item Cat#:
NTL-100 (Aluminum) 01-0261
NTL-101 (Stainless Steel) 01-0262
ACR
ACR Systems Inc www.acrsystems.com
10 Toll-Free: 1.800.663.7845
ISO 9001 Certified
Battery
Tel: 1.604.591.1128 Rev:4 - 02/02/10
[email protected] ISO9000\SPECIFICATIONS\NAUTILUS85.pdf