MT Series: Commercial & Utility Solar System Solutions

This document provides a design for a 2MWp solar system including: - An overview of the PV panel configuration using 280Wp panels for a total capacity of 2.3MWp - Selection of 36 Goodwe GW50K-MT inverters with a total capacity of 1.98MW to handle the 2.3MWp of solar panels - A monitoring plan using 12 Ezlogger Pro monitors to monitor the 36 inverters - A system design drawing showing the layout of the solar arrays, inverters, transformers, and electrical connections

Uploaded by

Marcelo Silva
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
40 views16 pages

MT Series: Commercial & Utility Solar System Solutions

This document provides a design for a 2MWp solar system including: - An overview of the PV panel configuration using 280Wp panels for a total capacity of 2.3MWp - Selection of 36 Goodwe GW50K-MT inverters with a total capacity of 1.98MW to handle the 2.3MWp of solar panels - A monitoring plan using 12 Ezlogger Pro monitors to monitor the 36 inverters - A system design drawing showing the layout of the solar arrays, inverters, transformers, and electrical connections

Uploaded by

Marcelo Silva
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 16

MT Series

Commercial & Utility


Solar System Solutions

www.goodwe.com
50/60/70kW
4 MPPT 400/500Vac Inverter

70kW Efficiency
100.00%
99.00%
98.00%
97.00%
96.00% 550V

95.00% 750V
Efficiency[%]

94.00% 850V

93.00%
92.00%
91.00%
90.00%
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
Load[%]

30% DC Input 15% AC Output Full-load 20% More


Oversizing Ratio Overloading Ratio Operation at 50°C Compact
Maximise Profit for Your Commercial & Utility

Projects with MT Series


2MWp Solar System Design
PV Panel Configuration
PV information:
Pmax= 280Wp;
Vmp= 31.6V, Imp= 8.86A;
Voc= 39.05V, Isc= 9.38A, Efficiency= 17.12%
Dimension: 1650*991*35mm

Total installation capacity:


1) Consider the best inclination of the local brackets (according to the local latitude).
2) Consider shading in the front (reasonable array spacing).
Total Quantity: 8280 pcs
Total Capacity: 2.3MWp

Inverter Selection

Inverter GW50K-MT

DC Input 64.4kW
Norminal AC Voltage 380V
Norminal AC Power 50kW
Max. AC Power 55kW
1) Maximum output power up to 110% Pn at PF= 1
Total No. of Inverter 36 pcs
Inverter actual output: 1.98MW
Total No. of DC Input 360
2) DC/AC ratio up to 1.3
Total No. of MPPT 144 PV panel capacity: 2.3MW Inverter capacity: 1.8MW

Monitor Selection

Ezlogger Pro
12 pcs

COM1

12 pcs
By RJ45 cable
or by Wi-Fi
RS485 COM2

12 pcs

COM3

• Different inverter series can use the same Ezlogger Pro by RS485.
• The effective transmission distance of the RS485 cable is 1000m.
• One Ezlogger Pro can monitor up to 60 inverters, with a capacity ranging from 3MW to 4.68MW.
• Goodwe inverters are able to perform string level monitoring.
System Design Drawing

10KV Ring Main Unit


(Load switch cabinet)
630A 25KA
XRNT-12KA
HY5WZ-17/45
DXN-10/Q

Two Circuit Transformer


S11-1000/1250KVA
10.5+2×2.5%/0.4KV
Dyn11 Ud=6%

Low Voltage AC Distribution


Cabinet (GCK/MNS)
ACB CT SPD
Voltmeter Ammeter

2×Antiflaming-VLV22-
0.6/1KV-3×240+120

1 3 1 3
AC Combiner Box*6
Breaker: 600A/3P+N
Breaker: 100A/3P+N

VLV22-0.6/1KV-4×35

GW50K-MT×36 D1 D2 D3 D4 D5 D6 C1 C2 C3 C4 C5 C6 B1 B2 B3 B4 B5 B6 A1 A2 A3 A4 A5 A6

PFG1169-1×4 cable
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
23 modules per string 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
capacity for each 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22
inverter is 64KW 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23
10strings 10strings 10strings 10strings 10strings 10strings 10strings 10strings 10strings 10strings 10strings 10strings 10strings 10strings 10strings 10strings 10strings 10strings 10strings 10strings 10strings 10strings 10strings 10strings

3*6 in 1 AC BOX 3*6 in 1 AC BOX

1: Goodwe inverter has integrated a Level II SPD on both DC and AC sides, therefore rendering unnecessary installation of a second SPD.
2: GoodWe inverter has no-neutral line type, delta type transformer is applicable.

Project Components

No. Equipment Specification Quantity


1 Mono Panel 280Wp 8280 pcs
2 PV Support Bracket Aluminum Alloy depends
3 Inverters GW50K-MT 36 pcs
4 AC Combiner Box 6 in 1 6 pcs
5 Transformer S11-1250KVA-10.5±2×2.5%/0.4kV Dyn11 Ud= 6% 2 pcs
6 DC Cable PFG1169-1×4mm2 depends
7 AC Cable VLV22-0.6/1KV-3×35+16mm2 depends
8 Communication Cable RS485 depends
9 Monitor Ezlogger Pro 1 pcs

Yield Calculation
Production Forecast
300,000

240,000 PV Generation (AC grid)

180,000

120,000
It depends on the irradiation time & intensity.
E.g.: Shanghai, China
Energy in kw/h

60,000
The PV system generates approximately
0 2,622,107 kwh/year
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Month
8MWp Solar System Design
PV Panel Configuration
PV information:
Pmax= 280Wp;
Vmp= 31.6V, Imp= 8.86A;
Voc= 39.05V, Isc= 9.38A, Efficiency= 17.12%
Dimension: 1650*991*35mm

Total installation capacity:


1) Consider the best inclination of the local brackets (according to the local latitude).
2) Consider shading in the front (reasonable array spacing).
Total Quantity: 33120 pcs
Total Capacity: 9.27MWp

Inverter Selection

Inverter GW60K-MT

DC Input 77.28kW
Norminal AC Voltage 380V
Norminal AC Power 60kW
Max. AC Power 66kW
1) Max output power up to 110% Pn at PF= 1
Total No. of Inverter 120 pcs
Inverter actual output: 7.92MW
Total No. of DC Input 1440
2) DC/AC ratio up to 1.3
Total No. of MPPT 480 PV panel capacity: 9.27MW Inverter capacity: 7.2MW

Monitor Selection

Ezlogger Pro
20 pcs

COM1

20 pcs
By RJ45 cable
or by Wi-Fi
RS485 COM2

20 pcs

Use 2 Ezlogger Pro for 120 inverters COM3

• Different inverter series can use the same Ezlogger Pro by RS485.
• The effective transmission distance of the RS485 cable is 1000m.
• One Ezlogger Pro can monitor up to 60 inverters, with a capacity ranging from 3MW to 4.68MW.
• Goodwe inverters are able to perform string level monitoring.
System Design Drawing

Eight Circuit Transformer


2500KVA
1 4

Low Voltage AC Distribution


Cabinet (GCK/MNS)
ACB CT SPD
Voltmeter Ammeter

1 5 1 5

AC Combiner Box*20

VLV22-0.6/1KV-4×35

GW60K-MT×120 D1 D2 D3 D4 D5 D6 D1 D2 D3 D4 D5 D6 D1 D2 D3 D4 D5 D6 D1 D2 D3 D4 D5 D6

PFG1169-1×4 cable
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
23 modules per string 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
capacity for each 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22
inverter is 77KW 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23
12strings 12strings 12strings 12strings 12strings 12strings 10strings 10strings 10strings 10strings 10strings 10strings 12strings 12strings 12strings 12strings 12strings 12strings 10strings 10strings 10strings 10strings 10strings 10strings

5*6 in 1 AC BOX 5*6 in 1 AC BOX

1: Goodwe inverter has integrated a Level II SPD on both DC and AC sides, therefore rendering unnecessary installation of a second SPD.
2: GoodWe inverter has no-neutral line type, delta type transformer is applicable.

Project Components

No. Equipment Specification Quantity


1 Mono Panel 280Wp 33120 pcs
2 PV Support Bracket Aluminum Alloy depends
3 Inverters GW60K-MT 120 pcs
4 AC Combiner Box 6 in 1 20 pcs
5 Transformer 2500KVA-16/0.4KV 4 pcs
6 DC Cable PFG1169-1×4mm2 depends
2
7 AC Cable VLV22-0.6/1kV-3×35+16mm depends
8 Communication Cable RS485 depends
9 Monitor Ezlogger Pro 2 pcs

Yield Calculation
Production Forecast
300,000

240,000 PV Generation (AC grid)

180,000

120,000
It depends on the irradiation time & intensity.
E.g.: Shanghai, China
Energy in kw/h

60,000
The PV system generates approximately
0 10,488,431 kwh/year
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Month
20MWp Solar System Design
PV Panel Configuration
PV information:
Pmax= 320Wp;
Vmp= 33.80V, Imp= 9.47A;
Voc= 40.56V, Isc= 9.94A, Efficiency= 19%
Dimensions: 1685*1000*32mm

Total installed capacity:


1) Consider the best inclination of the local brackets (according to the local latitude).
2) Consider shading in the front (reasonable array spacing).
Total Quantity: 71760 pcs
Total Capacity: 23MWp

Inverter Selection

Inverter GW70K-MT

DC Input 88.3kW
Norminal AC Voltage 480V
Norminal AC Power 70kW
Max. AC Power 77kW
1) Max output power up to 110% Pn at PF= 1
Total No. of Inverter 260 pcs
Inverter actual output: 20MW
Total No. of DC Input 3120
2) DC/AC ratio up to 1.3
Total No. of MPPT 1040 PV panel capacity: 23MW Inverter capacity: 18.2MW

Monitor Selection

Ezlogger Pro
20 pcs

COM1

20 pcs
By RJ45 cable
or by Wi-Fi
RS485 COM2

20 pcs

Use 5 Ezlogger Pros for 260 inverters COM3

• Different inverter series can use the same Ezlogger Pro by RS485.
• The effective transmission distance of the RS485 cable is 1000m.
• One Ezlogger Pro can monitor up to 60 Inverters, with a capacity ranging from 3MW to 4.68MW.
• Goodwe inverters are able to perform string level monitoring.
System Design Drawing

Eight Circuit Transformer


2500KVA
1 7 8

Low Voltage AC Distribution


Cabinet (GCK/MNS)
ACB CT SPD
Voltmeter Ammeter

1 4 1 6

AC Combiner Box*34

VLV22-0.6/1KV-4×35

GW70K-MT×260 D1 D2 D3 D4 D5 D6 D7 D8 D1 D2 D3 D4 D5 D6 D7 D8 D1 D2 D3 D4 D5 D6 D1 D2 D3 D4 D5 D6

PFG1169-1×4 cable
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
23 modules per string 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
capacity for each 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22
inverter is 77KW 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23
12strings 12strings 12strings 12strings 12strings 12strings 12strings 12strings 12strings 12strings 12strings 12strings 12strings 12strings 12strings 12strings 12strings 12strings 12strings 12strings 12strings 12strings 10strings 10strings 10strings 10strings 10strings 10strings

4*8 in 1 AC BOX 6*6 in 1 AC BOX

1: Goodwe inverter has integrated a Level II SPD on both DC and AC sides, therefore rendering unnecessary installation of a second SPD.
2: GoodWe inverter has no-neutral line type, delta type transformer is applicable.

Project Components

No. Equipment Specification Quantity


1 Mono Panel 320Wp 71760 pcs
2 PV Support Bracket Aluminum Alloy depends
3 Inverters GW60K-MT 260 pcs
4 AC Combiner Box 6 in 1 & 8 in 1 6 pcs & 28 pcs
5 Transformer 2500KVA-16/0.48KV 8 pcs
6 DC Cable PFG1169-1×4mm2 depends
2
7 AC Cable VLV22-0.6/1kV-3×35+16mm depends
8 Communication Cable RS485 depends
9 Monitor Ezlogger Pro 5 pcs

Yield Calculation
Production Forecast
300,000

240,000 PV Generation (AC grid)

180,000

120,000
It depends on the irradiation time & intensity.
E.g.: Shanghai, China
Energy in kw/h

60,000
The PV system generates approximately
0 26,333,204 kwh/year
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Month
18MW Konya | Turkey
11MW De Munt Emmeloord | Holland
2MW
Izmir | Turkey
MT Series Datasheet

Technical Data GW50K-MT GW60K-MT GW70KHV-MT


PV String Input Data

Max. PV Power (W) 65000 80000 87500

Max. DC Input Voltage (V) 1000 1000 1100

MPPT Range (V) 200~850 200~850 200~1000

Start-up Voltage (V) 200 200 200

MPPT Range for Full Load (V) 520~850 520~850 550~850

Nominal DC Input Voltage (V) 620 620 750

Max. Input Current (A) 30/30/20/20 30/30/30/30 33/33/33/33

Max. Short Current (A) 38/38/25/25 38/38/38/38 41.5/41.5/41.5/41.5

No. of MPP Trackers 4 4 4

No. of Input Strings per Tracker 3/3/2/2 3/3/3/3 3/3/3/3

AC Output Data

Nominal Output Power (W) 50000 60000 70000

Max. Output Power (W) 55000, 57500@415Vac 66000, 69000@415Vac 77000

Max. Output Apparent Power (VA) 55000, 57500@415Vac 66000, 69000@415Vac 77000

Nominal Output Voltage (V) 400, 3L/N/PE or 3L/PE 400, 3L/N/PE or 3L/PE 500, 3L/PE

Nominal Ouput Frequency (Hz) 50/60 50/60 50/60

Max. Output Current (A) 80 96 89

Output Power Factor ~1 (Adjustable from 0.8 leading to 0.8 lagging)

Output THDi (@Nominal Output) <3% <3% <3%

Efficiency

Max. Efficiency 98.7% 98.8% 99.0%

Euro Efficiency 98.3% 98.5% 98.4%

Protection

PV String Current Monitoring Integrated Integrated Integrated

Anti-islanding Protection Integrated Integrated Integrated

Input Reverse Polarity Protection Integrated Integrated Integrated

Insulation Monitoring Integrated Integrated Integrated

DC Fuse Integrated Integrated Integrated

Anti-PID Function for Module Optional Optional Optional

DC SPD Protection Integrated (Type II) Integrated (Type II) Integrated (Type II)

AC SPD Protection Integrated (Type II) Integrated (Type II) Integrated (Type II)

Residual Current Monitoring Unit Integrated Integrated Integrated

AC Over Current Protection Integrated Integrated Integrated

AC Short Protection Integrated Integrated Integrated

AC Over Voltage Protection Integrated Integrated Integrated


Technical Data GW50K-MT GW60K-MT GW70KHV-MT
General Data

Operating Temperature Range (°C) -30~60 -30~60 -30~60

Relative Humidity 0~100% 0~100% 0~100%

Operating Altitude (m) ≤4000 ≤4000 ≤4000

Cooling Fan Cooling Fan Cooling Fan Cooling

User Interface LCD or WiFi+APP LCD or WiFi+APP LED, WiFi+APP, LCD (Optional)

Communication RS485 or WiFi RS485 or WiFi RS485 ; WiFi; PLC (Optional)

Weight (kg) 59 64 60

Size (Width*Height*Depth mm) 586*788*264 586*788*264 586*788*264

Protection Degree IP65 IP65 IP65

Night Self Consumption (W) <1 <1 <1

Topology Transformerless Transformerless Transformerless

Certifications & Standards

Grid Regulation VDE-0126-1-1, AS4777.2, G59/3, VDE-AR-N 4105, EN50438

Safety Regulation EN62109-1&-2

EMC EN61000-6-1, EN64000-6-2, EN1000-6-3, EN61000-6-4

GW70KHV-MT Circuit Diagram


GoodWe (China) GoodWe (Germany)
No.189 Kunlunshan Rd., SND, Suzhou, 215163, China Fürstenrieder Str. 279a 81377 München, Germany
T: +86 (0) 512 6239 6771 T: +49 89 74 120 210
[email protected] [email protected]
[email protected] [email protected]

GoodWe (Brazil) GoodWe (Netherlands)


Rua Abelardo 45, Recife/PE, 52050-310 Franciscusdreef 42C, 3565AC Utrecht, the Netherlands
T: +55 54 992504491 T: +31 (0) 30 737 1140
[email protected] [email protected]
[email protected] [email protected]

GoodWe (UK) GoodWe (India)


6 Dunhams Court, Dunhams Lane, Letchworth 1202, G-Square Business Park, Sector 30A, Opp. Sanpada
Garden City, SG6 1WB UK Railway Stn., Vashi, Navi Mumbai- 400703
T:+ 44 (0) 333 358 3184 T: +91 (0) 2249746788
[email protected] [email protected]
[email protected] [email protected]

GoodWe (Italy) GoodWe (Turkey)


No. 17 Via Galimberti, Biella 13900, Italy Adalet Mah. Megapol Tower K: 9 No: 110 Bayraklı - Izmir
T: +31 (0) 30 737 1140 T: +90 (232) 935 68 18
[email protected] [email protected]
[email protected] [email protected]

GoodWe (Australia) GoodWe (Mexico)


Level 14, 380 St. Kilda Road, Melbourne, Oswaldo Sanchez Norte 3615, Col. Hidalgo, Monterrey,
Victoria, 3004, Australia Nuevo Leon, Mexico, C.P. 64290
T: +61 (0) 3 9918 3905 T: +52 1 81 2871 2871
[email protected] [email protected]
[email protected] [email protected]

You might also like