0% found this document useful (0 votes)
134 views

Hotflow Heating System: Heavy Duty Heating Controls & Automation Operation

The document describes the CSM HOTflow heating system from Hotstart. The system is a coolant preheater designed to maintain optimal engine temperatures. It features powerful pumps and heating elements, multiple configuration options, and automatic controls. The CSM provides a single heater solution as an alternative to using multiple conventional heaters.

Uploaded by

Josip Bhp Gustin
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
134 views

Hotflow Heating System: Heavy Duty Heating Controls & Automation Operation

The document describes the CSM HOTflow heating system from Hotstart. The system is a coolant preheater designed to maintain optimal engine temperatures. It features powerful pumps and heating elements, multiple configuration options, and automatic controls. The CSM provides a single heater solution as an alternative to using multiple conventional heaters.

Uploaded by

Josip Bhp Gustin
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

HOTflow®Heating System

CSM
CSM Style B shown
with flange pump.

Hotstart's CSM HOTflow ® heating


system is a coolant preheater,
developed to maintain optimal
temperatures for diesel and gas
engines in stationary land power,
marine, construction equipment, and
truck applications
CSM Style A shown
with union pump.

HEAVY DUTY HEATING CONTROLS & AUTOMATION


The CSM features the most powerful pump (10 OPERATION
gpm flow) and most powerful heating element The CSM's control box allows for easy power
options (up to 12 kW) in the HOTflow lineup. connections and enables automatic heater
The CSM's heating power in an energy efficient operation, eliminating the need for additional
system is ideal for replacing costly convection- customer-supplied control components.
based heaters in large-engine installations up to
100 L displacement.

MULTIPLE CONFIGURATIONS SINGLE HEATER SOLUTION


The CSM lineup is equipped to meet a wide The CSM's power and pump-driven forced
array of conditions, including power source $ $
circulation provides superior heat distribution,
requirements and agency certifications. making the CSM a viable option to replace
Whatever your power or heating needs, there's paired or multiple convection-based heaters –
a CSM to meet your specific heating system improving heating performance while reducing
application. maintenance costs.

hotstart.com [email protected] DS-CSM-E


© 2020 Hotstart $ $ 2020-3/rev14
HOTflow®Heating System

CSM
W
A
D
A
CSM Style A shown Ordering Information
with UL-recognized
union pump. CSM
Dimensions
may vary.
H
A
Power Supply Heating System
Engine
Displacement
V Ø Hz kW Amps Style Model Number
120 1 60 3 26.3 A CSM10301-000
W
B
D
B
208 1 60 3 15.1 A CSM10308-000
208 3 60 3 8.7 B CSM30308-000
1000 – 1500 CID 230 1 50 3 13.7 A **CSM1030J-5A0
15 – 25  L 240 1 60 3 13.1 A CSM10302-000
B
H
CSM Style B shown with
400 3 50 3 4.9 B **CSM3030A-5A0
CE-compliant union 480 1 60 3 3.8 B CSM10304-000
pump. Dimensions
may vary. 480 3 60 3 4.4 B CSM30304-000
208 1 60 6 29.6 A CSM10608-000
Style A 208 3 60 6 17.1 B CSM30608-000
Height* (H ) A
Width (W ) A
Depth (D ) A
Weight 230 1 50 6 26.7 A **CSM1060J-5A0
15.0” 19.4” 9.5” 37 lbs 240 1 60 6 25.6 A CSM10602-000
1500 – 3000 CID
383 mm 493 mm 242 mm 16.8 kg 400 3 50 6 8.9 B **CSM3060A-5A0
25 – 50 L
440 3 60 6 8.1 B **CSM3060F-5A1
Style B
480 1 60 6 12.8 B CSM10604-000
Height* (HB) Width (WB) Depth (DB) Weight 480 3 60 6 7.4 B CSM30604-000
17.0” 19.4” 9.5” 54 lbs 575 3 60 6 6.2 B CSM30605-000
434 mm 493 mm 242 mm 24.5 kg 208 1 60 9 44.0 A CSM10908-000
208 3 60 9 25.4 B CSM30908-000
* Height values are stated for flange connection pump. If union pump is installed, the
model's height will decrease by approximately 1.5” (38 mm). 230 1 50 9 39.8 A **CSM1090J-5A0
240 1 60 9 38.1 A CSM10902-000
System 3000 – 4500 CID
400 3 50 9 13.2 B **CSM3090A-5A0
Phase single-phase (1 Ø) three-phase (3 Ø) 50 – 75 L
440 3 60 9 12.2 B **CSM3090F-5A1
Voltage (60 Hz) 120 V 208 V 240 V 440 V 480 V 575 V 480 1 60 9 19.1 B CSM10904-000
Voltage (50 Hz) 230 V 400 V 480 3 60 9 11.0 B CSM30904-000
Control Box Ingress NEMA 4 / IP66 575 3 60 9 9.2 B CSM30905-000
Motor Ingress NEMA 2 (UL-listed) / IP44 (CE-compliant) 208 1 60 10.5 51.2 B CSM11058-000
Min./Max. Ambient Temp. -4 – 104 °F (-20 – 40 °C) 208 3 60 12 33.7 B CSM31208-000
230 1 50 12 52.8 B **CSM1120J-5A0
UL/C-US listed models available (E250789)
Certification 240 1 60 12 50.6 B CSM11202-000
CE-compliant models available
4500 – 6000 CID
400 3 50 12 17.5 B **CSM3120A-5A0
75 – 100 L
Coolant 440 3 60 12 15.9 B **CSM3120F-5A2

Fluid Type Water Coolant mix (50% water/50% glycol) 480 1 60 12 25.3 B CSM11204-000
480 3 60 12 14.6 B CSM31204-000
Heat Power 3 kW 6 kW 9 kW 10.5 kW 12 kW
575 3 60 12 12.2 B CSM31205-000
Temp. Control Fixed, 100 – 120 °F (38 – 49 °C)
Pump Power 97 W (60 Hz) / 70 W (50 Hz) ** – CE-compliant/union pump Other voltages available.
configuration Consult the factory.
Flow 10 gpm @ 10 ft WC (37.9 L/min @ 3 m WC)
Max. Pressure 125 psi (860 kPa) Options shown represent typical tested or certified configurations.
Additional options or configurations may be available. For assistance with
Pressure Loss 0.2 psi (1.5 kPa) your heating system application, contact HOTSTART at 509.536.8660 or
Inlet/Outlet 1” NPT [email protected].

hotstart.com [email protected] DS-CSM-E