0% found this document useful (0 votes)
48 views

CO Detector: Key Points

This document summarizes the specifications and features of a CO detector. It has a large backlit LCD display, detects CO levels in ppm and temperature in degrees C, and has two adjustable alarm thresholds. It uses an electrochemical sensor and electrolyte solution to measure CO levels through increases in electron production. The detector is accurate to within 3 ppm or 3% of readings and is designed for easy use with a shock-proof housing.

Uploaded by

kumar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
48 views

CO Detector: Key Points

This document summarizes the specifications and features of a CO detector. It has a large backlit LCD display, detects CO levels in ppm and temperature in degrees C, and has two adjustable alarm thresholds. It uses an electrochemical sensor and electrolyte solution to measure CO levels through increases in electron production. The detector is accurate to within 3 ppm or 3% of readings and is designed for easy use with a shock-proof housing.

Uploaded by

kumar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Supplied Calibration

with*
certificate

CO detector
CO 100

KEY POINTS

- Easy to use - Displaying of COmax


- Large backlight display - Two adjustable alarm thresholds
- Indication of CO in ppm and
temperature in ° C

TECHNICAL FEATURES

Display 4 lines, LCD technology. Dim. 50 x 34,9 mm.


Housing Shock-proof made in ABS, IP54 protection
Keypad Metal-coated with 5 keys
Conformity Electromagnetical compatilbility (NF EN 61326-1 guideline)
Power supply 1 alkaline battery 9V 6LR61 FUNCTIONS
Environment Neutral gas ●
CO detection
Working temperature From 0 to +50 °C ●
Displaying of ambient
Storage temperature From -20 to +80 °C temperature
Auto-extinction Adjustable from 0 to 120 mn

Two adjustable alarm
thresholds
Weight 200 g ●
COmax display
Languages French, English ●
Digital display

SPECIFICATIONS

Measurement Measurement range Accuracy1 Resolutions


units
CO
From 0 to 100 ppm ±3 ppm
ppm 0,1 ppm
From 100 to 500 ppm ±3 % of reading
Ambient temperature
°C, °F From - 20 to +80 °C ±0.3% of reading ±0,25°C 0,1°C
1
All accuracies indicated in this document were stated in laboratory conditions and can be guaranteed for measurements carried out in the same conditions, or
carried out with required compensation.

*except class 100S


DIMENSIONS in mm WORKING PRINCIPLE

When CO goes through an alectrolyte


• Top view • Front view • Side view solution,it intercedes in the reactions of
50
electrolyse and produces an increase
of the quantity of produced electrons.
The source electrons of a current
which is around microampere are
directly proportional to CO

34,9
concentration.
70,6
70.6

Electrochimical sensor

147,7
Gas
Working electrode e-

FTang – CO100 – 13/01/11 – RCS (24) Périgueux 349 282 095 Non-contractual document – We reserve the right to modify the characteristics of our products without prior notice.
Electrolyte OH-, HCO3-, CO32- A

Auxiliary electrode
Air

WARANTY PERIOD
Instruments have 1-year guarantee for any manufacturing defect (return to our After-Sales
Service required for appraisal).

SUPPLIED WITH

DESCRIPTION CO 100 CO 100 S


Supplied with
Calibration certificate
Carrying case Optional
Adjusting certificate
Transport case

ACCESSORIES

CE 100 RTS

Protective cover Telescopic


with magnet and extension
holding system Length : 1m with
index at 90°