Outline For Electrical Design Analysis: Fractal Knowledge Training Services

This document outlines a continuing development program on electrical design analysis. The 9-hour course covers voltage drop calculation, fault calculation studies, and case studies. It discusses key Philippine standards and regulations including DPWH Memorandum Circular No. 02-2015, DILG Memorandum Circular No. 23-2016, and PEC 2009. The program includes workshops and teaches techniques for performing voltage drop and fault calculations manually and in Excel. It emphasizes the importance of design analysis for electrical systems.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
118 views

Outline For Electrical Design Analysis: Fractal Knowledge Training Services

This document outlines a continuing development program on electrical design analysis. The 9-hour course covers voltage drop calculation, fault calculation studies, and case studies. It discusses key Philippine standards and regulations including DPWH Memorandum Circular No. 02-2015, DILG Memorandum Circular No. 23-2016, and PEC 2009. The program includes workshops and teaches techniques for performing voltage drop and fault calculations manually and in Excel. It emphasizes the importance of design analysis for electrical systems.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

FRACTAL KNOWLEDGE TRAINING SERVICES

Tel No. 02 - 904 - 2590 : Email : [email protected]


CPD PROVIDER: Accreditation # 2017-030

Outline for Electrical Design Analysis

DPWH Memorandum Circular No. 02-2015,


DILG Memorandum Circular No. 23-2016,
PEC 2009, Article 1.2, p25, Art. 1.3.2.1(f) p.31

Continuing Development Program


Part Time
I. Introduction
- Welcome 0.5 hrs
- Objectives of the course
- Importance of DPWH Memorandum Circular No. 02-2015
- Importance of DILG Memorandum Circular No. 23-2016
- PEC 2 2009 : Art 1.2 and Art 1.3.2 (f)
II. Codes and Standards
- Discussion of PEC Chapter 2 ,Article 1.2 (Page 27) 0.5 hr
- Discussion of DPWH & DILG Memorandum Circulars
- The needs and reasons for Electrical Design Analysis
- Discussion , Q&A
III Design Analysis 1: Voltage Drop
- Objectives 2.5 hrs
- Importance of Voltage Drop in Design Analysis
- Standard on Acceptable Voltage Drop
- Requirement for Voltage Drop Calculation
- Computation of Wires and Cables Voltage Drop, Manual
- Computation of Wires and Cables Voltage Drop, MS Excel
- Template for presenting Voltage Drop Results : OBO Requirement
- Workshop1 : Residential Computation, Single phase
- Workshop2 : Industrial & Commercial Sample computation, 3 phase
- Skills Reinforcement
- Discussion , Q&A
IV Design Analysis 2: Faults Calculation Study
- Objectives 4.0 hrs
- Understanding the importance of Short Circuit Calculation
- Identifying the sources of Faults
- Use of Short Circuit Calculation Studies
- Preliminaries and requirements of Fault Calculation
- Impedance Computations for Cables, Motors, Transformers, Lump Loads
- Simplification of Impedance Diagram for SC calculation
- Calculation of Short Circuits , I3Ǿsc , IL-L, IL-G, IL-L-G, Manual
- Calculation of Short Circuits , I3Ǿsc , IL-L, IL-G, IL-L-G, MS Excel
FRACTAL KNOWLEDGE TRAINING SERVICES
Tel No. 02 - 904 - 2590 : Email : [email protected]
CPD PROVIDER: Accreditation # 2017-030

- Analysis of Short Circuits and kAIC sizing


- Template for presenting Voltage Drop Results : OBO Requirement
- Workshop1 : Hands-on Residential Computation
- Workshop2 : Hands-on Industrial & Commercial Sample computation
- Discussion , Q&A

V CASE STUDY & ASSESSMENT, SUMMARY & RECAP


Reinforcement of Learning : Creating Design Analysis Document 1.5 hr
- Case Study 1 – Residential & Commercial Application
- Case Study 2 – Industrial Application (VD & SC Calculation)
- Case Study 3 – Industrial Plant Application 2MVA ( SC Calculation)
- Preparation of Design Analysis Documents
- OBO requirement for Design Analysis
- Directory of PEE to Sign and Seal Design Analysis
- Discussion , Q&A
TOTAL 9.0 hrs
VI References
1. Philippine Electrical Code 2009 (PEC 1)
2. National Electrical Code 2011 (NFPA 70)
3. IEEE Std 141 – Red Book – Recommended Practice for Electric Power
Distribution for Industrial Plant
4. IEEE Std 551 – Violet Book – Calculating Short Circuit in Industrial and
Commercial Power System
5. DPWH Memorandum Circular No. 02-2015
6. DILG Memorandum Circular No. 23-2016

Prepared by:

Bernabe T. Salazar Jr, PEE


PRC # 0003874, PTR # 0869088E
Issued at Paranaque City
Date Issued: Jan 4, 2017