Pressure Relief Valves Agam: Two Stage, Subplate Mounting - ISO 6264 Size 10, 20 and 32
Pressure Relief Valves Agam: Two Stage, Subplate Mounting - ISO 6264 Size 10, 20 and 32
1 MODEL CODE
Setting pressure and venting option: Voltage code, see section 8 (1):
- =one setting pressure without option
10=one setting pressure with venting,
with de-energized solenoid X = without connector (1):
11=one setting pressure with venting, See section 7 for available connectors, to be
with energized solenoid ordered separately
20=two setting pressure with venting,
-00 = solenoid valve without coils (for -I)
with de-energized solenoid
-00-AC = AC solenoid valve without coils (for -E)
21=two setting pressure with venting,
-00-DC = DC solenoid valve without coils (for -E)
with energized solenoid
22=two setting pressure without venting
32=three setting pressure without venting
Pilot valve (1):
I = DHI for AC and DC supply,
Setting: see section 3 for available setting (1)
with CURUS certified solenoids
E = DHE for AC and DC supply, high performances
with CURUS certified solenoids
C066
2 HYDRAULIC SYMBOLS
3 HYDRAULIC CHARACTERISTICS
4 MAIN CHARACTERISTICS, SEALS AND FLUIDS - for other fluids not included in below table, consult our technical office
Max fluid contamination level ISO4406 class 20/18/15 NAS1638 class 9, see also filter section at www.atos.com or KTF catalog
Hydraulic fluid Suitable seals type Classification Ref. Standard
Mineral oils NBR, FKM, HNBR HL, HLP, HLPD, HVLP, HVLPD DIN 51524
Protection degree to DIN EN 60529 IP 65 (with connectors 666, 667, 669 or E-SD correctly assembled)
Relative duty factor 100%
Supply voltage and frequency See electric feature 7
Supply voltage tolerance ± 10%
Certification CURUS North American standard
5 OPTIONS
/E = external pilot
/V = regulating handwheel instead of grub screw protected by cap (for handwheel features, see table K150)
/WP = prolunged manual override protected by rubber cap (only for AGAM with pilot solenoid valve)
/Y = external drain (only for AGAM with pilot solenoid valve)
6 ELECTRIC CONNECTORS ACCORDING TO DIN 43650 FOR AGAM WITH SOLENOID VALVE
The connectors must be ordered separately
Power
Solenoid External supply Colour of
Voltage Type of consumption Code of spare coil Code of spare coil
valve nominal voltage coil label
code connector (3) DHI DHE
type ± 10% (1) DHI
DHI DHE
(1) For other supply voltages available on request see technical tables E010, E015. (4) When AC solenoid is energized, the inrush
(2) Coil can be supplied also with 60 Hz of voltage frequency: in this case the performances are current is approx 3 times the holding current.
reduced by 10 ÷ 15% and the power consumption is 55 VA (DHI) and 58 VA (5) Only for DHE
(3) Average values based on tests performed at nominal hydraulic condition and (6) Only for DHI
ambient/coil temperature of 20°C.
8 REGULATED PRESSURE VERSUS FLOW DIAGRAMS based on mineral oil ISO VG 46 at 50°C
C066
10 MINIMUM PRESSURE VERSUS FLOW DIAGRAMS based on mineral oil ISO VG 46 at 50°C
11 DIMENSIONS [mm]
AGAM-10
ISO 6264: 2007
69
Mounting surface: 6264-06-09-1-97
Fastening bolts:
= 4 socket head screws
103
54
M12x35 class 12.9
27
X= G1/4
=
15
109
109
79
112
82
116
75
X= G1/4
25
4
69 ø6 ø17
12.5 123.5 2 ø25
138 = =
102.5 Mass: 4,8Kg
X
86.2
ISO 6264: 2007
Mounting surface: 6264-08-11-1-97
=
Fastening bolts:
4 socket head screws M16x50 class 12.9
70
109
109
109
79
112
82
C066
AGAM-32
109.9 ISO 6264: 2007
Mounting surface: 6264-10-17-1-97
(with M20 fixing holes instead
=
of standard M18)
116
82.6
Fastening bolts:
75
X= G1/4
41.3
4 socket head screws
=
22
4
M20x60 class 12.9
92.5 ø6 ø24.5 Tightening torque = 600 Nm
2 157 3 ø31 12.7 31.8 Seals: 2 OR 4131; 1 OR 109/70
= = 44.5 Ports P, T: Ø = 28,5 mm
121.5
Ports X: Ø = 3,2 mm
X 76.2
109
109
109
79
112
112
82
12 MOUNTING SUBPLATES
Ports Ø Counterbore
Valve Subplate model [mm] Mass
Port location [Kg]
P T X P T X
AGAM-10 BA-306 G 1/2" G 3/4" G 1/4" 30 36,5 21,5 1,5
BA-406 G 3/4" G 3/4" G 1/4" 36,5 36,5 21,5 3,5
AGAM-20 Ports P, T, X underneath;
BA-506 G 1" G 1" G 1/4" 46 46 21,5 3,5
AGAM-32 BA-706 G 1 1/2" G 1 1/2" G 1/4" 63,5 63,5 21,5 6
The subplates are supplied with fastening bolts. For further details see table K280
11/19