1.0) Pile Load Distribution: y X 1 1 2 2... 1+ 2... Z 1 1 2 2... 1+ 2... y Z y X
The document provides information on pile load distribution for a pile with a 0.25 m diameter supporting an axial working load of 2500 kN. It includes the pile dimensions, allowable working load, location of piles, and calculations of load distribution, moments, and section properties. The maximum positive load on a pile is 515.34 kN which is less than the allowable working load, therefore the pile configuration is considered safe.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
12 views1 page
1.0) Pile Load Distribution: y X 1 1 2 2... 1+ 2... Z 1 1 2 2... 1+ 2... y Z y X
The document provides information on pile load distribution for a pile with a 0.25 m diameter supporting an axial working load of 2500 kN. It includes the pile dimensions, allowable working load, location of piles, and calculations of load distribution, moments, and section properties. The maximum positive load on a pile is 515.34 kN which is less than the allowable working load, therefore the pile configuration is considered safe.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1
Z
1.0) Pile Load Distribution G13
Pile Dimension = 0.25 m
Allowable Pile Working Load = 600 kN
Axial Working Load (Py) = 2500 kN
ex= Σ(x1a1+x2a2...)/(Σ(a1+a2...) = -0.0855 m ez = Σ(z1a1+z2a2...)/(Σ(a1+a2...) = -0.0075 m Transv Moment (Mx=Py*ez) = 18.75 kNm Long'l Moment (Mz=Py*ex) = 213.75 kNm