0% found this document useful (0 votes)
186 views30 pages

Plumbing Fixtures

This document provides specifications for plumbing fixtures for a project. It includes standards that fixtures must meet, submittal requirements, delivery and storage instructions, and a list of extra materials to provide. Fixtures covered include lavatory/sink faucets, bathtub/shower faucets, and other bathroom fixtures. Compliance with industry standards is required for water closets, urinals, and other plumbing components.

Uploaded by

adel rihana
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
186 views30 pages

Plumbing Fixtures

This document provides specifications for plumbing fixtures for a project. It includes standards that fixtures must meet, submittal requirements, delivery and storage instructions, and a list of extra materials to provide. Fixtures covered include lavatory/sink faucets, bathtub/shower faucets, and other bathroom fixtures. Compliance with industry standards is required for water closets, urinals, and other plumbing components.

Uploaded by

adel rihana
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 30

<Project Title>

PROJECT STANDARD SPECIFICATION

SECTION 15440 - PLUMBING FIXTURES

PART 1 - GENERAL

0.1 RELATED DOCUMENTS

A. Drawings and general provisions of the Contract, including Conditions of Contract and
Division 1 Specification Sections, apply to this Section.

0.2 SUMMARY

A. This Section includes plumbing fixtures and trim, faucets, other fittings, and related
components.

B. Related Sections: The following Sections contain requirements that relate to this Section:

1. Division 7 Section "Joint Sealants" for sealing between fixtures and walls, floors, and
counters.
2. Division 10 Section "Toilet and Bath Accessories" for toilet and bath accessories.
3. Division 15 Section "Valves" for general-duty valves used as supply stops.
4. Division 15 Section "Plumbing Specialties" for backflow preventers and other
specialties not specified in this Section.

0.3 DEFINITIONS

A. Accessible: Plumbing fixture, building, facility, or portion thereof that can be approached,
entered, and used by physically handicapped, disabled, and elderly people.

B. Fitting: Device that controls flow of water into or out of plumbing fixture. Fittings
specified in this Section include supplies and stops, faucets and spouts, shower heads and
tub spouts, drains and tailpieces, traps and waste pipes. Pipe fittings, tube fittings, and
general-duty valves are included where indicated.

0.4 SUBMITTALS

A. Product Data: For each plumbing fixture category and type specified. Include selected
fixture, trim, fittings, accessories, appliances, appurtenances, equipment, and supports.
Indicate materials and finishes, dimensions, construction details, and flow-control rates.

B. Wiring diagrams from manufacturer for electrically operated units.

C. Maintenance data for plumbing fixtures and components to include in the operation and
maintenance manuals specified in Division 1.

0.5 QUALITY ASSURANCE

A. Source Limitations: Obtain plumbing fixtures, faucets, and other components of each
category from one source and by a single manufacturer.

PLUMBING FIXTURES 15440 - Page 1/30


STD-SPC-DCA(A1)-ME-DCA REV A
<Project Title>

PROJECT STANDARD SPECIFICATION

1. Exception: Where fixtures, faucets, or other components are not available from a
single manufacturer, obtain similar products from other manufacturers specified for
this category.

B. Listing and Labeling: Provide electrically operated fixtures and components specified in
this Section that are listed and labeled.

C. Select combinations of fixtures and trim, faucets, fittings, and other components that are
compatible.

D. Coordinate with architectural drawings in color selection and installation of plumbing


fixtures.

0.6 DELIVERY, STORAGE, AND HANDLING

A. Deliver plumbing fixtures in manufacturer's protective packing, crating, and covering.

B. Store plumbing fixtures on elevated platforms in dry location.

0.7 PROJECT CONDITIONS

A. Field Measurements: Coordinate roughing-in and final fixture locations and verify that
plumbing fixtures can be installed to comply with original design and referenced standards.

0.8 EXTRA MATERIALS

A. Furnish extra materials described below that match products installed, are packaged with
protective covering for storage, and are identified with labels describing contents. Deliver
extra materials to the Employer.

1. Faucet Washers and O-Rings: Furnish quantity of identical units not less than 10
percent of each type and size installed.
2. Faucet Cartridges and O-Rings: Furnish quantity of identical units not less than 5
percent of each type and size installed.
3. Faucet, Laminar-Flow Fittings: Furnish quantity of identical units not less than 10
percent of each type and size installed.
4. Faucet, Flow-Control Fittings: Furnish quantity of identical units not less than 10
percent of each type and size installed.
5. Supply, Flow-Control Fittings: Furnish quantity of identical units not less than 5
percent of each type and size installed.
6. Shower, Flow-Control Fittings: Furnish quantity of identical units not less than 5
percent of each type and size installed.
7. Flushometer Valve, Repair Kits: Furnish quantity of identical units not less than 10
percent of each type installed.
8. Provide hinged-top, wood or metal box, or individual metal boxes, having separate
compartments for each type and size of extra materials listed above.
9. Flushometer Tank, Repair Kits: Furnish quantity of identical units not less than 5
percent of each type installed.
10. Water-Closet Tank, Repair Kits: Furnish quantity of identical units not less than 5
percent of each type installed.

PLUMBING FIXTURES 15440 - Page 2/30


STD-SPC-DCA(A1)-ME-DCA REV A
<Project Title>

PROJECT STANDARD SPECIFICATION

11. Toilet Seats: Furnish quantity of identical units not less than 5 percent of each type
installed.
12. Filter Cartridges: Furnish quantity of identical units not less than 50 percent of each
type and size installed.

PART 2 - PRODUCTS

0.1 PLUMBING FIXTURE STANDARDS

A. Comply with applicable standards below and other requirements specified.

1. Electric Water Coolers: ARI 1010 and UL 399.


2. Emergency Equipment: ANSI Z358.1.
3. Enameled, Cast-Iron Fixtures: ASME A112.19.1M.
4. National Sanitation Foundation Construction: NSF 2.
5. Plastic Bathtubs: ANSI Z124.1, ANSI Z124.1a, and ANSI Z124.1b.
6. Plastic Lavatories: ANSI Z124.3 and ANSI Z124.3a.
7. Plastic Laundry Trays: ANSI Z124.6.
8. Plastic Mop-Service Basins: ANSI Z124.6.
9. Plastic Shower Enclosures: ANSI Z124.2 and ANSI Z124.2a.
10. Plastic Sinks: ANSI Z124.6.
11. Plastic Whirlpool Bathtubs: ANSI Z124.1, ANSI Z124.1a, and ANSI Z124.1b; and
ASME A112.19.7M.
12. Porcelain-Enameled Fixtures: ASME A112.19.4M.
13. Semivitreous Ceramic Fixtures: ASME A112.19.9M.
14. Slip-Resistant Bathing Surfaces: ASTM F 462.
15. Stainless-Steel Fixtures Other than Service Sinks: ASME A112.19.3M.
16. Vitreous-China Fixtures: ASME A112.19.2M.

a. Exception: ASME A112.19.9M, semivitreous, ceramic fixtures, except water-


closet bowls and urinals with integral traps, may be furnished instead of
vitreous-china fixtures.

17. Water-Closet, Flush Valve, Tank Trim: ASME A112.19.5.


18. Water-Closet, Flushometer Tank Trim: ASSE 1037.
19. Whirlpool Bathtub Fittings: ASME A112.19.8M.

0.2 LAVATORY/SINK FAUCET STANDARDS

A. Comply with ASME A112.18.1M and other requirements specified for lavatory, sink, and
similar-type-fixture faucet fittings. Include hot- and cold-water indicators; 0.16-L/s-
maximum flow rate; and polished, chrome-plated finish; except where otherwise indicated.
Coordinate faucet inlets with supplies and fixture holes and outlet with spout and fixture
receptor.

1. Diverter Valves for Faucets with Hose Spray: ASSE 1025.


2. Faucet Hose:
3. Hose-Connection Vacuum Breakers: ASSE 1011.
4. Hose-Coupling Threads: ASME B1.20.7.
5. Integral, Atmospheric Vacuum Breakers: ASSE 1001.
6. Pipe Threads: ASME B1.20.1.
7. Sensor-Actuated Faucets and Electrical Devices: UL 1951.
PLUMBING FIXTURES 15440 - Page 3/30
STD-SPC-DCA(A1)-ME-DCA REV A
<Project Title>

PROJECT STANDARD SPECIFICATION

8. Sink Spray Hoses:

0.3 BATHTUB/SHOWER FAUCET STANDARDS

A. Comply with ASME A112.18.1M and other requirements specified for bathtub and shower
faucet fittings. Include hot- and cold-water indicators; 0.16-L/s- maximum flow rate; and
polished, chrome-plated finish; except where otherwise indicated. Coordinate faucet inlets
with supplies and outlet with diverter valve; tub spout; and shower head, arm, and flange.

1. Combination, Pressure-Equalizing- and Thermostatic-Control, Antiscald Faucets:


ASSE 1016.
2. Hand-Held Showers: ASSE 1014.
3. High-Temperature-Limit Controls for Thermal-Shock-Preventing Devices:
ASTM F 445.
4. Hose-Coupling Threads: ASME B1.20.1 or ASME B1.20.7.
5. Manual-Control Antiscald Faucets: ASTM F 444.
6. Pipe Threads: ASME B1.20.1.
7. Pressure-Equalizing-Control Antiscald Faucets: ASTM F 444 and ASSE 1016.
8. Sensor-Actuated Faucets and Electrical Devices: UL 1951.
9. Thermostatic-Control Antiscald Faucets: ASTM F 444 and ASSE 1016.

0.4 MISCELLANEOUS FITTING STANDARDS

A. Comply with ASME A112.18.1M and other requirements specified for fittings, other than
faucets. Include polished, chrome-plated finish, except where otherwise indicated.
Coordinate fittings with other components and connectors.

1. Atmospheric Vacuum Breakers: ASSE 1001.


2. Automatic Flow Restrictors: ASSE 1028.
3. Brass and Copper, Supplies and Tubular Brass: ASME A112.18.1M.
4. Fixed Flow Restrictors: ASSE 1034.
5. Manual-Operation Flushometers: ASSE 1037.
6. Plastic Tubular Fittings: ASTM F 409.
7. Sensor-Operation Flushometers: ASSE 1037 and UL 1951.

0.5 MISCELLANEOUS COMPONENT STANDARDS

A. Comply with applicable standards below and other requirements specified for components
for plumbing fixtures, equipment, and appliances.

1. Disposers: ASSE 1008 and UL 430.


2. Floor Drains: ASME A112.21.1M.
3. Grab Bars: ASTM F 446.
4. Hose-Coupling Threads: ASME B1.20.7.
5. Hot-Water Dispensers: ASSE 1023 and UL 499.
6. Pipe Threads: ASME B1.20.1.
7. Plastic Shower Receptors: ANSI Z124.2 and ANSI Z124.2a.
8. Plastic Toilet Seats: ANSI Z124.5.
9. Supply and Drain Insulation Kits: CABO A117.1.
10. Supports: ASME A112.6.1M.
11. Whirlpool Bathtub Equipment: UL 1795.

PLUMBING FIXTURES 15440 - Page 4/30


STD-SPC-DCA(A1)-ME-DCA REV A
<Project Title>

PROJECT STANDARD SPECIFICATION

0.6 FITTINGS

A. Fittings for Plumbing Fixtures: Refer to plumbing fixture schedules at the end of this
Section for materials for supplies, supply stops, supply risers, traps, and other fittings.

B. Fittings for Equipment Specified in Other Sections: Fittings include the following:

1. Supply Inlets: Brass pipe or copper tube, size required for final connection.
2. Supply Stops: Chrome-plated brass, angle or straight; compression, loose-key type;
same size as supply inlet and with outlet matching supply riser.
3. Supply Stops: Chrome-plated brass, angle or straight; compression, wheel-handle
type; same size as supply inlet and with outlet matching supply riser.
4. Supply Risers: DN10 flexible copper tube with knob end. Use chrome-plated tube
for exposed applications.
5. Supply Risers: DN10 rigid brass tube with DN8 straight, knob-end tailpiece. Use
chrome-plated tube for exposed applications.
6. Supply Risers: DN10 rigid brass tube with DN8 offset, knob-end tailpiece. Use
chrome-plated tube for exposed applications.
7. Traps: Tubular brass with 1.1 mm wall thickness, with no-leak slip-joint inlet,
cleanout, wall flange, escutcheons, and size to match equipment. Use chrome-plated
tube for exposed applications.
8. Traps: Cast brass with no-leak slip-joint inlet, cleanout pipe nipple to wall, wall
flange, escutcheons, and size to match equipment. Use chrome-plated tube for
exposed applications.
9. Continuous Waste: Tubular brass, 1.1 mm wall thickness, with no-leak slip-joint
inlet, and size to match equipment.
10. Continuous Waste: Tubular brass, 0.8 mm wall thickness, with no-leak slip-joint
inlet, and size to match equipment.
11. Continuous Waste: Tubular plastic with no-leak slip-joint inlet and size to match
equipment.
12. Indirect Waste: Tubular brass, 1.1 mm wall thickness, and size to match equipment.
13. Indirect Waste: Tubular brass, 0.8 mm wall thickness, and size to match equipment.
14. Indirect Waste: Tubular plastic and size to match equipment.

PART 3 - EXECUTION

0.1 EXAMINATION

A. Examine roughing-in for potable, hot- and cold-water supply piping systems; soil, waste,
and vent piping systems; and supports. Verify that locations and sizes of piping and
locations and types of supports match those indicated, before installing and connecting
fixtures. Use manufacturer's roughing-in data when roughing-in data are not indicated.

B. Examine walls, floors, and cabinets for suitable conditions where fixtures are to be installed.

C. Do not proceed until unsatisfactory conditions have been corrected.

0.2 APPLICATIONS

A. Include supports for plumbing fixtures specified in this Section or other Sections, according
to the following:

PLUMBING FIXTURES 15440 - Page 5/30


STD-SPC-DCA(A1)-ME-DCA REV A
<Project Title>

PROJECT STANDARD SPECIFICATION

1. Carriers: For wall-hanging water closets and fixtures supported from wall
construction.
2. Chair Carriers: For wall-hanging urinals, lavatories, sinks, drinking fountains, and
electric water coolers.
3. Heavy-Duty Chair Carriers: For accessible urinals, lavatories, and other fixtures
where indicated.
4. Reinforcement: For floor-mounted lavatories and sinks that require securing to wall
and recessed, box-mounted, electric water coolers.
5. Fabricate reinforcement from 50 mm by 100 mm or 50 mm by 150 mm fire-retardant-
treated-wood blocking between studs or 6 mm by150 mm steel plates attached to
studs, in wall construction, to secure fixtures to wall. Include length that will extend
beyond ends of fixture mounting bracket and attach to at least 2 studs.

B. Include fitting insulation kits for accessible fixtures according to the following:

1. Lavatories: Cover hot- and cold-water supplies, stops and handles, drain, trap, and
waste to wall.
2. Lavatories: Cover hot-water supply, stop and handle, drain, trap, and waste to wall.
3. Sinks: Cover hot- and cold-water supplies, stops and handles, drain, trap, and waste
to wall.
4. Sinks: Cover hot-water supply, stop and handle, drain, trap, and waste to wall.
5. Fixtures with Offset Drain: Cover hot- and cold-water supplies, offset drain, trap,
and waste to wall.
6. Fixtures with Offset Drain: Cover hot-water supply, offset drain, trap, and waste to
wall.
7. Other Fixtures: Cover exposed fittings below fixture.

0.3 PLUMBING FIXTURE INSTALLATION

A. Assemble plumbing fixtures and trim, fittings, faucets, and other components according to
manufacturers' written instructions.

B. Install fixtures level and plumb according to manufacturers' written instructions, roughing-in
drawings, and referenced standards.

C. Install floor-mounted, floor-outlet water closets with closet flanges and gasket seals.

D. Install floor-mounted, back-outlet water closets with fittings and gasket seals.

E. Install wall-hanging, back-outlet water closets with support manufacturer's tiling frame or
setting gage.

F. Install toilet seats on water closets.

G. Install wall-hanging, back-outlet urinals with gasket seals.

H. Install flushometer valves for accessible water closets and urinals with handle mounted on
wide side of compartment. Install other actuators in locations that are easy for handicapped
people to reach.

I. Install tanks for accessible, tank-type water closets with lever handle mounted on wide side
of compartment.

PLUMBING FIXTURES 15440 - Page 6/30


STD-SPC-DCA(A1)-ME-DCA REV A
<Project Title>

PROJECT STANDARD SPECIFICATION

J. Fasten wall-hanging plumbing fixtures securely to supports attached to building substrate


when supports are specified, and to building wall construction where no support is
indicated.

K. Fasten floor-mounted fixtures to substrate. Fasten fixtures having holes for securing fixture
to wall construction, to reinforcement built into walls.

L. Fasten recessed, wall-mounted fittings to reinforcement built into walls.

M. Fasten wall-mounted fittings to reinforcement built into walls.

N. Fasten counter-mounting plumbing fixtures to casework.

O. Secure supplies to supports or substrate within pipe space behind fixture.

P. Set shower receptors and mop basins in leveling bed of cement grout.

Q. Install individual stop valve in each water supply to fixture. Use gate or globe valve where
specific stop valve is not specified.

1. Exception: Omit stop valves on supplies to emergency equipment, except when


permitted by authorities having jurisdiction. When permitted, install valve chained
and locked in OPEN position.

R. Install water-supply stop valves in accessible locations.

S. Install faucet, laminar-flow fittings with specified flow rates and patterns in faucet spouts
when faucets are not available with required rates and patterns. Include adapters when
required.

T. Install supply, flow-control fittings with specified flow rates in fixture supplies at stop
valves.

U. Install faucet, flow-control fittings with specified flow rates and patterns in faucet spouts
when faucets are not available with required rates and patterns. Include adapters when
required.

V. Install shower, flow-control fittings with specified maximum flow rates in shower arms.

W. Install traps on fixture outlets. Omit traps on fixtures having integral traps. Omit traps on
indirect wastes, except where otherwise indicated.

X. Install disposers in sink outlets. Install switch where indicated, or in wall adjacent to sink if
location is not indicated.

Y. Install hot-water dispensers in back top surface of sink or in counter with spout over sink.

Z. Install escutcheons at wall, floor, and ceiling penetrations in exposed, finished locations and
within cabinets and millwork. Use deep-pattern escutcheons where required to conceal
protruding pipe fittings.

AA. Seal joints between fixtures and walls, floors, and counters using sanitary-type, 1-part,
mildew-resistant, silicone sealant according to sealing requirements specified in Division 7
Section "Joint Sealants." Match sealant color to fixture color.

PLUMBING FIXTURES 15440 - Page 7/30


STD-SPC-DCA(A1)-ME-DCA REV A
<Project Title>

PROJECT STANDARD SPECIFICATION

BB. Comply with ADA requirements for installation of fixtures in areas accessible to the
handicapped.

0.4 CONNECTIONS

A. Piping installation requirements are specified in other Division 15 Sections. Drawings


indicate general arrangement of piping, fittings, and specialties. The following are specific
connection requirements:

1. Install piping connections between plumbing fixtures and piping systems and
plumbing equipment specified in other Division 15 Sections.

B. Supply and Waste Connections to Plumbing Fixtures: Refer to plumbing fixture schedules
at the end of this Section for fitting sizes and connection requirements for each plumbing
fixture.

C. Supply and Waste Connections to Equipment Specified in Other Sections: Connect


equipment with supply inlets, supply stops, supply risers, and traps specified in this Section.
Use fitting sizes required to match connected equipment. Connect fittings to plumbing
piping.

D. Ground equipment.

1. Tighten electrical connectors and terminals according to manufacturer's published


torque-tightening values. Where manufacturer's torque values are not indicated, use
those specified in UL 486A and UL 486B.

E. Arrange for electric-power connections to fixtures and devices that require power. Electric
power is specified in Division 16 Sections.

0.5 FIELD QUALITY CONTROL

A. Verify that installed fixtures are categories and types specified for locations where installed.

B. Check that fixtures are complete with trim, faucets, fittings, and other specified components.

C. Inspect installed fixtures for damage. Replace damaged fixtures and components.

D. Test installed fixtures after water systems are pressurized and demonstrate proper operation.
Replace malfunctioning fixtures and components, then retest. Repeat procedure until units
operate properly.

0.6 ADJUSTING AND CLEANING

A. Operate and adjust faucets and controls. Replace damaged and malfunctioning fixtures,
fittings, and controls.

B. Operate and adjust disposers, hot-water dispensers, and controls. Replace damaged and
malfunctioning units and controls.

C. Adjust water pressure at drinking fountains, electric water coolers, faucets, shower valves,
and flushometer valves having controls, to produce proper flow and stream.
PLUMBING FIXTURES 15440 - Page 8/30
STD-SPC-DCA(A1)-ME-DCA REV A
<Project Title>

PROJECT STANDARD SPECIFICATION

D. Replace washers and seals of leaking and dripping faucets and stops.

E. Clean fixtures, faucets, and other fittings, including flush tanks, with manufacturers'
recommended cleaning methods and materials. Include the following:

1. Remove faucet spouts and strainers, remove sediment and debris, and reinstall
strainers and spouts.
2. Remove sediment and debris from flush tanks and drains.

0.7 PROTECTION

A. Provide protective covering for installed fixtures and fittings.

B. Do not allow use of fixtures for temporary facilities, except when approved in writing by the
Engineer.

0.8 WATER CLOSET SCHEDULE

A. Water Closet EWC-[#]: Where plumbing fixtures of this designation are indicated, provide
products complying with the following:

1. Available Products: Subject to compliance with requirements, products that may be


incorporated into the Work include, but are not limited to, the following:
2. Vitreous-China Water Closet:

a. <INSERT PRODUCT NAME>;.

3. Flushometer Valve:

a. <INSERT PRODUCT NAME; >

4. Toilet Seat:

a. <INSERT PRODUCT NAME>;

5. Fixture Color: [White.] <INSERT OTHER>


6. Bowl Type and Operation: [Elongated, siphon jet.] [Elongated, blowout.] [Round
front, siphon jet.] <INSERT OTHER>
7. Mounting and Outlet: [Floor mounted, floor outlet.] [Wall hanging, back outlet.]
[Floor mounted, back outlet.]
8. Fixture Bolt Caps: [White,] [Color matching bowl,] plastic or china.
9. Rim Height: [356 to 394 mm .] [445 to 457 mm .] [254 mm .] <INSERT OTHER>
10. Tank: [Close coupled.] [One-piece bowl and tank.] <INSERT OTHER>
11. Tank Trim: [Flush valve.] [Flushometer tank.]
12. Accessible-Fixture Tank: [Modified as required for lever or push-button mounting on
top of tank or on side of tank that will be on wide side of fixture compartment.]
13. Design Water Consumption: [6 L per flushing cycle.] [13.2 L per flushing cycle.]
<INSERT OTHER>
14. Flushometer Valve Construction: Cast-brass body, brass or copper pipe or tubing
inlet with wall flange and tailpiece with spud, screwdriver check stop, and vacuum
breaker.
15. Flushometer Valve Operation: [Diaphragm.] <INSERT OTHER>

PLUMBING FIXTURES 15440 - Page 9/30


STD-SPC-DCA(A1)-ME-DCA REV A
<Project Title>

PROJECT STANDARD SPECIFICATION

16. Flushometer Valve Finish: [Rough brass.] [Polished, chrome-plated, exposed metal
parts.]
17. Flushometer Valve, Water Consumption and Pressure: Factory set or field adjusted,
6 L maximum per flushing cycle at 0.5 bars. <INSERT OTHER>
18. Flushometer valve components include the following:

a. Brass, lever-handle actuation.


b. Bacteria-control-coated, brass, lever-handle actuation.
c. Nonhold-open feature.
d. Wheel-handle stop.
e. Metal, push-button actuation.
f. Seat bumper on stop.
g. Hydraulic, push-button-actuation, flushing system.
h. Bedpan washer with diverter valve, spray head, and support.
i. Battery-powered, sensor-actuation, automatic flushing system.
j. Electric, hard-wired, sensor-actuation, automatic flushing system.
k. Tailpiece, trap-primer connection.

19. Supply Inlet: [DN15] [DN10] with wall flange.


20. Supply Stop: [Loose key.] [Wheel handle.] <INSERT OTHER>
21. Supply Riser: [DN15,] [DN10,] [flexible riser with collar end.] [rigid riser with
collar end.]
22. Toilet Seat: Solid-plastic, water-closet seat with bumpers and hardware, compatible
with water closet and as follows:

a. Color: [White.] [Black.] [Matching water closet.] <INSERT OTHER>


b. Class: [Commercial, Heavy Duty.] [Commercial, Standard.] [Residential.]
[Commercial, Extra-Heavy-Duty type, exceeding requirements of Commercial,
Standard class.]
c. Size: [Elongated.] [Round front.]
d. Pattern: [Open front without cover.] [Open front with cover.] [Closed front
with cover.]
e. Hinge Type: [Check (CK).] [Noncheck (NC).] [Self-sustaining check (SC).]
[Self-raising (SR).]

23. Fixture Support: Vertically adjustable, cast-iron, {elevated-type,} water-closet


carrier with combination support and waste fitting assemblies and tiling frame or
setting gage. Include additional faceplate and coupling for water closet at wide pipe
space. Compact-type carrier for back-to-back water-closet installation is prohibited.
24. Reinforcement: <INSERT SPECIFIC REQUIREMENTS, IF APPLICABLE>

B. Wheelchair Water Closets: Provide same as specified for water closets P-[ ] except water
closet height to top of seat shall be 432 to 483 mm above floor and complete with two white
nylon coated aluminium grap/support rails with fixing plates to wall provided with four sets
of walls plugs and 45 mm screws, 450 mm and 970 mm long

0.9 URINAL SCHEDULE

A. [Accessible] }Urinal UR-[#]: Where plumbing fixtures of this designation are indicated,
provide products complying with the following:

PLUMBING FIXTURES 15440 - Page 10/30


STD-SPC-DCA(A1)-ME-DCA REV A
<Project Title>

PROJECT STANDARD SPECIFICATION

1. Available Products: Subject to compliance with requirements, products that may be


incorporated into the Work include, but are not limited to, the following:
2. Products: Subject to compliance with requirements, provide one of the following:
3. Vitreous-China Urinal:

a. <INSERT PRODUCT NAME;

4. Flushometer Valve:
5. Fixture Color: [White.] <INSERT OTHER>
6. Type and Operation: [Siphon jet.] [Washdown.] [Blowout.] <INSERT OTHER>
7. Mounting and Outlet: [Wall hanging, back outlet.] [Wall hanging, bottom outlet.]
[Floor mounted, floor outlet.]
8. Fixture Bolt Caps: [White,] [Color matching bowl,] plastic or china.
9. Rim Height: [610 mm.] [432 mm.] <INSERT OTHER>
10. Design Water Consumption: [3.8 L per flushing cycle.] <INSERT OTHER>
11. Flushometer Valve Construction: Cast-brass body, brass or copper pipe or tubing
inlet with wall flange and tailpiece with spud, screwdriver check stop, and vacuum
breaker.
12. Flushometer Valve Operation: [Diaphragm.] <INSERT OTHER>
13. Flushometer Valve Finish: [Rough brass.] [Polished, chrome-plated, exposed metal
parts.]
14. Flushometer Valve, Water Consumption and Pressure: [Factory set or field adjusted,
3.8 L maximum per flushing cycle at 0.5 bars.] <INSERT OTHER>
15. Flushometer valve components include the following:

a. Brass, lever-handle actuation.


b. Bacteria-control-coated, brass, lever-handle actuation.
c. Nonhold-open feature.
d. Wheel-handle stop.
e. Metal, push-button actuation.
f. Hydraulic, push-button-actuation, flushing system.
g. Electric, timer-actuation, automatic flushing system.
h. Battery-powered, sensor-actuation, automatic flushing system.
i. Electric, hard-wired, sensor-actuation, automatic flushing system.

16. Fixture Support: Type I, vertically adjustable, urinal, chair carrier with coupling;
[steel-pipe] [heavy-duty, rectangular-steel,] upright members; bearing plate; and feet.
<INSERT OTHER>
17. Reinforcement: <INSERT SPECIFIC REQUIREMENTS, IF APPLICABLE>

B. Wheelchair Flush Valve Type Urinals: Provide same as specified for urinal UR [] except
with elongated projecting bowl, 508 mm long from wall to front of flare, and ASME
A112.19.5 trim. Furnish urinal manufacturer's certification of conformance. Provide
ASME A112.6.1M concealed chair carriers. Mount urinal with front rim a maximum of 432
mm above floor and flush valve handle a maximum of 1118 mm above floor for use by
handicapped on wheelchair.

0.10 BIDET SCHEDULE

A. Bidet BD-[#]: Where plumbing fixtures of this designation are indicated, provide products
complying with the following:

PLUMBING FIXTURES 15440 - Page 11/30


STD-SPC-DCA(A1)-ME-DCA REV A
<Project Title>

PROJECT STANDARD SPECIFICATION

1. Available Products: Subject to compliance with requirements, products that may be


incorporated into the Work include, but are not limited to, the following:
2. Products: Subject to compliance with requirements, provide one of the following:
3. Fixture Material: Vitreous china.
4. Fixture Color: [White.] <INSERT OTHER>
5. Mounting: [Floor mounted.] [Wall hanging.]
6. Fixture Faucet-Hole Spacing: [One hole, centered.] [2 holes, 51 mm each side of
center.] [2 holes, 102 mm each side of center.] [3 holes, centered and 51 mm each
side of center.] [3 holes, centered and 102 mm each side of center.] <INSERT
OTHER>
7. Mounting: [Floor mounted.] [Wall hanging.]
8. Fixture Bolt Caps: [White,] [Color matching bowl,] plastic or china.
9. Faucet Construction: [Center set with inlets on 102 mm centers,] [Center set with
central inlets,] [Widespread with inlets on 203 mm centers,] [Single-inlet,] cast brass
with pop-up waste and vacuum breaker. <INSERT OTHER>
10. Faucet Valve Operation: Manual, ON-OFF, [over-rim.] [spray.] <INSERT OTHER>
11. Faucet Mounting Position: [Centered on fixture deck.] [Wall, centered on fixture.]
12. Faucet Components: Include the following:

a. Handle{s}: [Dual lever.] [Dual, metal knobs.] [Dual, crystal knobs.] [Single
lever.] <INSERT OTHER>
b. Spout: [Integral with body.] [Spray nozzle in bowl.] <INSERT OTHER>

13. Supply Inlets: [DN10,] [DN15,] brass pipe or copper tubing.


14. Supply Stops: Manufacturer's standard brass, angle or straight, compression, [loose-
key type,] [wheel-handle type,] same size as supply inlet and with outlet matching
supply riser. <INSERT OTHER>
15. Supply Risers: DN10 flexible with knob end. <INSERT OTHER>
16. Drain: Pop-up with DN32 tailpiece, included with faucet. <INSERT OTHER>
17. Tubular Trap: [DN32,] DN40 by DN32,] [1.1 mm wall thickness, tubular brass,]
[0.8 mm wall thickness, tubular brass,] [plastic tubular fittings,] with slip-joint inlet[,
cleanout,] and wall flange.
18. Cast-Brass Trap: [DN32,] [DN40 by DN32,] cast-brass trap, with slip-joint inlet,
[cleanout,] [DN32,] [DN40,] pipe nipple to wall, and wall flange.
19. Cast-Brass/Tubular Trap: [DN32,] [DN40 by DN32,] cast-brass trap, with slip-joint
inlet, {cleanout,} [DN32] [DN40] tubular brass, waste to wall, and wall flange.
20. Fixture Support: [Vertically adjustable, lavatory or sink, chair carrier with support
plate or device matching fixture mounting; steel-pipe upright members; and feet.]
<INSERT OTHER>
21. Reinforcement: <INSERT SPECIFIC REQUIREMENTS, IF APPLICABLE>

0.11 LAVATORY SCHEDULE

A. [Accessible] Lavatory LAV-[#]: Where plumbing fixtures of this designation are indicated,
provide products complying with the following:

1. Available Products: Subject to compliance with requirements, products that may be


incorporated into the Work include, but are not limited to, the following:
2. Products: Subject to compliance with requirements, provide one of the following:
3. Vitreous-China Lavatory:

a. <INSERT PRODUCT NAME;>

PLUMBING FIXTURES 15440 - Page 12/30


STD-SPC-DCA(A1)-ME-DCA REV A
<Project Title>

PROJECT STANDARD SPECIFICATION

4. Enameled, Cast-Iron Lavatory:

a. <INSERT PRODUCT NAME; >

5. Enameled, Steel Lavatory:

a. <INSERT PRODUCT NAME>

6. Stainless-Steel Lavatory:

a. <INSERT PRODUCT NAME;>

7. Plastic Lavatory:

a. <INSERT PRODUCT NAME;>

8. Faucet:

a. <INSERT PRODUCT NAME;>

9. Laminar-Flow, Faucet-Spout Fitting:

a. <INSERT PRODUCT NAME;> 

10. Hair Interceptor:

a. <INSERT PRODUCT NAME;> 

11. Fitting Insulation Kit:


12. Fixture Color: [White.] <INSERT OTHER>
13. Fixture Dimensions: <INSERT SIZE>
14. Fixture Faucet-Hole Spacing: [One hole, centered.] [2 holes, 51 mm each side of
center.] [2 holes, 102 mm each side of center.] [3 holes, centered and 51 mm each
side of center.] [3 holes, centered and 102 mm each side of center.] <INSERT
OTHER>
15. Mounting: [Wall hanging.] [Counter.] [Counter, self-rimming.] [Undercounter.]
[Wall hanging with pedestal.] <INSERT OTHER>
16. Faucet Construction: [Center set with inlets on 102 mm centers,] [Center set with
central inlets,] [Widespread with inlets on 203 mm centers,] [Single-inlet,] [cast
brass,] [cast-brass underbody and brass escutcheon,] [nonmetal (plastic) underbody
and plastic or brass escutcheon,] [and with pop-up waste.] [and without pop-up
waste.] <INSERT OTHER>
17. Faucet Valve Operation: [Manual, ON-OFF.] [Manual, adjustable, self-closing,
metering.] [Electric, hard wired, sensor actuation, automatic.] <INSERT OTHER>
18. Faucet Mounting Position: [Centered on fixture deck.] [Counter, centered on fixture.]
[Centered on fixture backsplash.]
19. Faucet Components: Include the following:

a. Accessible-Fixture Operation: [Manual.] [Sensor actuation.] <INSERT


OTHER>
b. Handle(s): [Dual lever.] [Dual, 3 or 4 arms.] [Dual, metal knobs.] [Dual,
crystal knobs.] [Dual, metering, self-closing, pushbuttons.] [Single-lever
toggle.] [Extended, single-lever toggle.] [Single, push-pull and twist.] [Dual,
102 mm wrist blade.] [Dual, 152 mm wrist blade.] <INSERT OTHER>
c. Spout: [Integral with body.] [Swing gooseneck.] [Fixed-position gooseneck.]
PLUMBING FIXTURES 15440 - Page 13/30
STD-SPC-DCA(A1)-ME-DCA REV A
<Project Title>

PROJECT STANDARD SPECIFICATION

d. Spout Length, Centerline of Inlets to Outlet: <INSERT IF OTHER THAN


MFR'S STANDARD>
e. Gooseneck Height and Offset, Centerline of Inlets to Outlet: <INSERT IF
OTHER THAN MFR'S STANDARD>
f. Spout Outlet: [Manufacturer's standard aerator.] [0.032-L/s laminar flow.]
[0.047-L/s laminar flow.] <INSERT OTHER>
g. Spout-Outlet, Flow-Control Fitting: [0.032 L/s.] [0.047 L/s.] <INSERT
OTHER>

20. Supply Inlets: [DN10,] [DN15,] brass pipe or copper tubing.


21. Supply Stops: Manufacturer's standard brass, angle or straight, compression, [loose-
key type,] [wheel-handle type,] same size as supply inlet and with outlet matching
supply riser. <INSERT OTHER>
22. Supply Risers: [DN10 flexible with knob end.] [DN10 rigid with DN8 straight,
knob-end tailpiece.] [DN10 rigid with DN8 offset, knob-end tailpiece.] <INSERT
OTHER>
23. Supply, Flow-Control Restrictors: [DN10,] [DN15,] 0.032 L/s. <INSERT OTHER>
24. Drain: [Grid strainer with DN32 tailpiece.] [Grid strainer with DN32 offset waste.]
[Pop-up with DN32 tailpiece, included with faucet.] [Open with rubber stopper and
chain.] <INSERT OTHER>
25. Tubular Trap: [DN32,] [DN40 by DN32,] [1.1 mm wall thickness, tubular brass,]
[0.8 mm wall thickness, tubular brass,] [plastic tubular fittings,] with slip-joint inlet[,
cleanout,] and wall flange.
26. Cast-Brass Trap: [DN32,] [DN40 by DN32,] cast-brass trap, with slip-joint inlet,
[cleanout,] [DN32,] [DN40,] pipe nipple to wall, and wall flange.
27. Cast-Brass/Tubular Trap: [DN32,] [DN40 by DN32,] cast-brass trap, with slip-joint
inlet, [cleanout,] [DN32] [DN40] tubular brass, waste to wall, and wall flange.
28. Hair-Interceptor Trap: Chrome-plated, brass [or stainless-steel] housing with
removable brass or stainless-steel screen or bucket; [DN32] [DN40] inlet and outlet,
pipe nipples to sink drain and wall; and wall flange.
29. Supply Insulation Kit: [Molded, soft-plastic covering for supplies from wall to
fixture with removable covering for stops and handles.] [Molded, soft-plastic
covering for hot-water supply from wall to fixture with removable covering for stop
and handle.] [Shaped, cushioned-jacket plastic covering with self-sticking fastening
system for supply stops and risers to fixture.] [Shaped, cushioned-jacket plastic
covering with self-sticking fastening system for hot-water supply stop and riser to
fixture.] Include manufacturer's standard fasteners, straps, and adhesives. <INSERT
COLOR IF REQUIRED>
30. Drain Insulation Kit: [Molded, soft-plastic covering for drain piping from fixture to
wall.] [Shaped, cushioned-jacket plastic covering with self-sticking fastening system
for drain piping and trap.] Include manufacturer's standard fasteners, straps, and
adhesives. <INSERT COLOR IF REQUIRED>
31. Fixture Support: [Type I, exposed arm;] [Type II, concealed arm;] [Type III, hanger
plate;] vertically adjustable, lavatory, chair carrier with [steel-pipe] [heavy-duty,
rectangular-steel,] upright members; and feet. <INSERT OTHER>
32. Reinforcement: <INSERT SPECIFIC REQUIREMENTS, IF APPLICABLE>

B. Wheelchair Lavatories: <TXT>Provide same as specified for lavatory LAV [ ] except


lavatory minimum dimensions to be 508 mm by 686 mm front to rear, 737 mm minimum
clearance from bottom of front rim to floor, 864 mm front rim height above floor. Provide
ASME A112.18.1M copper alloy centerset faucets, gooseneck spout with aerator 125 mm

PLUMBING FIXTURES 15440 - Page 14/30


STD-SPC-DCA(A1)-ME-DCA REV A
<Project Title>

PROJECT STANDARD SPECIFICATION

above rim, 100 mm wrist action handles, perforated grid strainers with offset tailpiece, and
32 mm adjustable P-trap.

0.12 SHOWER SCHEDULE

A. [Accessible] Shower SH-[#]: Where plumbing fixtures of this designation are indicated,
provide products complying with the following:

1. Available Products: Subject to compliance with requirements, products that may be


incorporated into the Work include, but are not limited to, the following:
2. Products: Subject to compliance with requirements, provide one of the following:
3. Plastic Shower Enclosure:

a. <INSERT PRODUCT NAME;>

4. Antiscald Faucet:

a. <INSERT PRODUCT NAME;>

5. Mixing-Valve Faucet and Miscellaneous Fittings:

a. <INSERT PRODUCT NAME;>

6. Cabinet Shower Unit:

a. <INSERT PRODUCT NAME;>

7. Terrazzo Shower Receptor:

a. <INSERT PRODUCT NAME;>

8. Plastic Shower Receptor:

a. <INSERT PRODUCT NAME;>

9. Fixture Enclosure Color: <INSERT COLOR>


10. Fixture Enclosure: [Built in-place] [Acrylic plastic] [Fiberglass plastic] [Enameled
steel][ with slip-resistant bathing surface]. <INSERT OTHER>
11. Fixture Enclosure Dimensions: <INSERT SIZE>
12. Fixture Enclosure Drain: Integral corrosion-resistant metal with removable strainer
and DN50 bottom outlet. <INSERT OTHER>
13. Fixture Enclosure Grab Bar: [Factory fabricated.] [Field installed.] <INSERT
DESCRIPTION AND LOCATION>
14. Shower Base Receptor: [Included with enclosure.] [Precast terrazzo] [Acrylic plastic]
[Fiberglass plastic] [Acrylic or fiberglass plastic] with threshold matching
enclosure[ and slip-resistant bathing surface]. Include integral corrosion-resistant-
metal drain with removable strainer and DN50 bottom outlet.
15. Shower Base Receptor Color: [Included with enclosure.] <INSERT COLOR>
16. Shower Base Receptor Dimensions: <INSERT SIZE AND SHAPE>
17. Faucet Construction: Cast-brass, [dual, manual-control, mixing valve with
escutcheons.] [pressure-equalizing-control{ with high-temperature-limit control},]
[thermostatic-control, with high-temperature-limit control,] single-handle mixing
valve with check stops, and escutcheon.
18. Faucet Components: Include the following:
PLUMBING FIXTURES 15440 - Page 15/30
STD-SPC-DCA(A1)-ME-DCA REV A
<Project Title>

PROJECT STANDARD SPECIFICATION

a. Handle(s): [Dual, 3 or 4 arms.] [Single-lever, chrome-plated brass.] [Crystal.]


<INSERT OTHER>
b. Shower Head, Arm, and Flange: [Manufacturer's standard {with manual flow
control in head}.] <INSERT OTHER>
c. Shower Arm, Flow-Control Fitting: [0.1 L/s.] [0.13 L/s.] [0.16 L/s.] <INSERT
OTHER>
d. Hand Shower, Hose, and Brackets or Slide: [Manufacturer's standard.]
<INSERT OTHER>
e. Hose-Supply, Flow-Control Fitting: [0.1 L/s.] [0.13 L/s.] [0.16 L/s.] <INSERT
OTHER>

19. Supplies: [Copper tubing with ball, gate, or globe valve if check stops not included
with faucet.] <INSERT OTHER>
20. Drain: [Included with enclosure.] [Included with receptor.] [DN50, nickel-bronze-
strainer, floor drain.] <INSERT OTHER>
21. Trap: [DN50 drainage piping.] <INSERT OTHER>
22. Reinforcement: <INSERT SPECIFIC REQUIREMENTS, IF APPLICABLE; ADD
BASE SUPPORT IF REQUIRED>

0.13 BATHTUB SCHEDULE

A. [Accessible ]Bathtub BT-[#]: Where plumbing fixtures of this designation are indicated,
provide products complying with the following:

1. Available Products: Subject to compliance with requirements, products that may be


incorporated into the Work include, but are not limited to, the following:
2. Products: Subject to compliance with requirements, provide one of the following:
3. Enameled, Cast-Iron Bathtub:

a. <INSERT PRODUCT NAME;>

4. Enameled, Steel Bathtub:

a. <INSERT PRODUCT NAME;>

5. Plastic Bathtub:

a. <INSERT PRODUCT NAME;>

6. Antiscald Bathtub Faucet:

a. <INSERT PRODUCT NAME;>

7. Mixing-Valve Faucet and Miscellaneous Fittings:

a. <INSERT PRODUCT NAME;>

8. Plastic Fixture Material: [Acrylic] [Fiberglass] plastic.


9. Fixture Color: <INSERT COLOR>
10. Fixture Dimensions: <INSERT SIZE>
11. Bathing Surface: [Manufacturer's standard.] [Slip resistant.]
12. Faucet Construction: Cast-brass, [dual, manual-control, mixing valve with
escutcheons.] [pressure-equalizing-control{ with high-temperature-limit control},]

PLUMBING FIXTURES 15440 - Page 16/30


STD-SPC-DCA(A1)-ME-DCA REV A
<Project Title>

PROJECT STANDARD SPECIFICATION

[thermostatic-control, with high-temperature-limit control,] single-handle mixing


valve with check stops, and escutcheon.
13. Faucet Components: Include the following:

a. Handle(s): [Dual, 3 or 4 arms.] [Single-lever, chrome-plated brass.] [Crystal.]


<INSERT OTHER>
b. Tub Filler Spout: [Manufacturer's standard.] <INSERT OTHER>
c. Shower Diverter Valve: [Manufacturer's standard.] <INSERT OTHER>
d. Shower Head, Arm, and Flange: [Manufacturer's standard {with manual flow
control in head}.] <INSERT OTHER>
e. Shower Arm, Flow-Control Fitting: [0.1 L/s.] [0.13 L/s.] [0.16 L/s.] <INSERT
OTHER>
f. Hand Shower, Hose, and Brackets or Slide: [Manufacturer's standard.]
<INSERT OTHER>
g. Hose-Supply, Flow-Control Fitting: [0.1 L/s.] [0.13 L/s.] [0.16 L/s.] <INSERT
OTHER>

14. Supplies: [Copper tubing with ball, gate, or globe valve if check stops not included
with faucet.] <INSERT OTHER>
15. Supplies: DN15 copper tubing. <INSERT OTHER>
16. Waste and Overflow Fitting: DN40, [1.1 mm] [0.8 mm] wall thickness, tubular brass.
Include lever-operated, pop-up waste and overflow with universal-type outlet
connection on waste tee; and DN40, [1.1 mm] [0.8 mm] wall thickness, tubular
waste. <INSERT OTHER>
17. Trap: DN40 cast brass with [pipe] [1.1 mm wall thickness, tubular-brass] waste.
<INSERT OTHER>
18. P-Trap: [DN40] [DN50] drainage piping.
19. Reinforcement: <INSERT SPECIFIC REQUIREMENTS, IF APPLICABLE; ADD
BASE SUPPORT IF REQUIRED>

0.14 WHIRLPOOL BATHTUB SCHEDULE

A. [Accessible] Whirlpool Bathtub WP-[#]: Where plumbing fixtures of this designation are
indicated, provide products complying with the following:

1. Available Products: Subject to compliance with requirements, products that may be


incorporated into the Work include, but are not limited to, the following:
2. Products: Subject to compliance with requirements, provide one of the following:
3. Enameled, Cast-Iron Whirlpool Bathtub:

a. <INSERT PRODUCT NAME;>

4. Enameled, Steel Whirlpool Bathtub:

a. <INSERT PRODUCT NAME;>

5. Plastic Whirlpool Bathtub:

a. <INSERT PRODUCT NAME;>

6. Plastic Fixture Material: [Acrylic] [Fiberglass] plastic.


7. Fixture Color: <INSERT COLOR>
8. Fixture Dimensions: <INSERT SIZE>

PLUMBING FIXTURES 15440 - Page 17/30


STD-SPC-DCA(A1)-ME-DCA REV A
<Project Title>

PROJECT STANDARD SPECIFICATION

9. Bathing Surface: [Manufacturer's standard.] [Slip resistant.]


10. Faucet: Manufacturer's standard cast-brass, manual-control mixing valve with dual,
supply valves and escutcheons. Include tub filler spout, and air-control valve.
<INSERT OTHER>
11. Whirlpool Fittings: [Manufacturer's standard.] <INSERT OTHER>
12. Controls: [Manufacturer's standard.] <INSERT OTHER>
13. Pump: <INSERT CAPACITY AND ELECTRICAL CHARACTERISTICS>
14. Water Heater: <INSERT CAPACITY AND ELECTRICAL CHARACTERISTICS>
15. Supplies: DN15 copper tubing. <INSERT OTHER>
16. Waste and Overflow Fitting: DN40, [1.1 mm] [0.8 mm] wall thickness, tubular brass.
Include lever-operated, pop-up waste and overflow with universal-type outlet
connection on waste tee; and DN40, [1.1 mm] [0.8 mm] wall thickness, tubular
waste. <INSERT OTHER>
17. Trap: DN40 cast brass with [pipe] [1.1 mm wall thickness, tubular-brass] waste.
<INSERT OTHER>
18. P-Trap: [DN40] [DN50] drainage piping.
19. Reinforcement: <INSERT SPECIFIC REQUIREMENTS, IF APPLICABLE; ADD
BASE SUPPORT IF REQUIRED>

0.15 WASH FOUNTAIN SCHEDULE

A. [Accessible] Wash Fountain WF-[#]: Where plumbing fixtures of this designation are
indicated, provide products complying with the following:

1. Available Products: Subject to compliance with requirements, products that may be


incorporated into the Work include, but are not limited to, the following:
2. Products: Subject to compliance with requirements, provide one of the following:

a. <INSERT PRODUCT NAME>

3. Applicable Standards: <INSERT IF KNOWN>


4. Bowl Material: [Terrazzo.] [Stainless steel.] [Plastic.] <INSERT OTHER>
5. Fixture Color or Finish: <INSERT IF REQUIRED>
6. No. of Stations: [One.] [2.] [3.] [4.] [6.] [8.]
7. Shape and Dimensions: [914 to 965 mm,] [1370 mm,] [round.] [semicircular.]
[corner.] [In-line (side by side).] <INSERT OTHER>
8. Mounting: [Floor.] [Wall.]
9. Faucet{s}: Manufacturer's standard [manual] [sensor-actuated] mixing valve with
check stops or field-installed check valves.
10. Supplies: [DN10] [DN15] [DN20] [DN25] copper tubing with ball, gate, or globe
valves.
11. Drain: Manufacturer's standard grid drain with [DN32] [DN40] [DN50] tailpiece.
<INSERT OTHER>
12. Cast-Brass Trap: [DN32,] [DN40 by DN32,] [DN40,] [DN50,] cast-brass trap, with
slip-joint inlet[, cleanout,] [DN32,] [DN40,] [DN50,] pipe nipple to wall, and wall
flange.
13. Cast-Brass/Tubular Trap: [DN32 ,] [DN40 by DN32 ,] [DN40 ,] [DN50 ,] cast-brass
trap, with slip-joint inlet[, cleanout,] [DN32,] [DN40,] [DN50,] [1.1 mm] [0.8 mm]
wall thickness, tubular brass, waste to wall, and wall flange.
14. P-Trap: [DN50] drainage piping. <INSERT OTHER>
15. Fixture Support: [Manufacturer's standard mounting frame.] <INSERT OTHER>
16. Reinforcement: <INSERT SPECIFIC REQUIREMENTS, IF APPLICABLE>

PLUMBING FIXTURES 15440 - Page 18/30


STD-SPC-DCA(A1)-ME-DCA REV A
<Project Title>

PROJECT STANDARD SPECIFICATION

0.16 SINK SCHEDULE

A. [Accessible] Sink S-[#]: Where plumbing fixtures of this designation are indicated, provide
products complying with the following:

1. Available Products: Subject to compliance with requirements, products that may be


incorporated into the Work include, but are not limited to, the following:
2. Products: Subject to compliance with requirements, provide one of the following:
3. Stainless-Steel Sink:

a. <INSERT PRODUCT NAME>

4. Enameled, Cast-Iron Sink:

a. <INSERT PRODUCT NAME>

5. Enameled, Steel Sink:

a. <INSERT PRODUCT NAME>

6. Plastic Sink:

a. <INSERT PRODUCT NAME>

7. Faucet:

a. <INSERT PRODUCT NAME>

8. Laminar-Flow, Faucet-Spout Fitting:

a. <INSERT PRODUCT NAME>

9. Disposer:

a. <INSERT PRODUCT NAME>

10. Hot-Water Dispenser:

a. <INSERT PRODUCT NAME>

11. [Sediment] [Plaster] Interceptor:

a. <INSERT PRODUCT NAME>

12. Fitting Insulation Kit:


13. Fixture Color: [White.] <INSERT OTHER>
14. Fixture Dimensions: <INSERT NO. OF COMPARTMENTS AND SIZES>
15. Fixture Stainless-Steel Thickness: [2.0 mm.] [1.6 mm.] [1.3 mm.] [1.0 mm.]
[0.8 mm.]
16. Fixture Faucet-Hole Spacing: [One hole, centered.] [2 holes, 51 mm each side of
center.] [2 holes, 102 mm each side of center.] [3 holes, centered and 51 mm each
side of center.] [3 holes, centered and 102 mm each side of center.] [4 holes,
centered, 102 mm each side of center, and 203 mm to left of center.] [5 holes,
centered, 102 mm each side of center, and 203 mm each side of center.] <INSERT
OTHER>

PLUMBING FIXTURES 15440 - Page 19/30


STD-SPC-DCA(A1)-ME-DCA REV A
<Project Title>

PROJECT STANDARD SPECIFICATION

17. Fixture Mounting: [Counter.] [Counter, self-rimming.] [Wall hanging.] <INSERT


OTHER>
18. Faucet Construction: [Center set with inlets on 102 mm centers,] [Center set with
central inlets,] [Widespread with inlets on 203 mm centers,] [Single-inlet,] [and cast
brass.] [and cast-brass underbody and brass escutcheon.] [and nonmetal (plastic)
underbody and plastic or brass escutcheon.] <INSERT OTHER>
19. Faucet Mounting: [Centered on fixture deck.] [Counter, centered on fixture.]
[Centered on fixture backsplash.] <INSERT OTHER>
20. Faucet Components: Include the following:

a. Accessible-Fixture Operation: [Manual.] [Sensor actuation.] <INSERT


OTHER>
b. Handle[s]: [Dual lever.] [Dual, 3 or 4 arms.] [Dual, metal knobs.] [Dual,
crystal knobs.] [Single-lever toggle.] [Extended, single-lever toggle.] [Single,
push-pull and twist.] [Dual, 102 mm wrist blades.] [Dual, 152 mm wrist
blades.] <INSERT OTHER>
c. Spout: [Integral with body.] [Swing.] [Swing gooseneck.] [Fixed-position
gooseneck.]
d. Spout Length, Centerline of Inlets to Outlet: <INSERT IF OTHER THAN
MFR'S STANDARD>
e. Gooseneck Height and Offset, Centerline of Inlets to Outlet: <INSERT IF
OTHER THAN MFR'S STANDARD>
f. Spout Outlet: [Manufacturer's standard aerator.] [0.1 L/s laminar flow.] [0.13
L/s laminar flow.] <INSERT OTHER>
g. Spout-Outlet, Flow-Control Fitting: [0.1 L/s.] [0.13 L/s.] <INSERT OTHER>

21. Supply Inlets: [DN15, brass pipe or copper tubing.] <INSERT OTHER>
22. Supply Stops: Manufacturer's standard brass, angle or straight, compression, [loose-
key type,] [wheel-handle type,] same size as supply inlet and with outlet matching
supply riser. <INSERT OTHER>
23. Supply Shutoff Valves: DN15 gate, globe, or ball.
24. Supply Risers: [DN10 flexible with knob end.] [DN10 rigid with DN8 straight,
knob-end tailpiece.] [DN10 rigid with DN8 offset, knob-end tailpiece.] [DN15 copper
tubing.] <INSERT OTHER>
25. Supply, Flow-Control Restrictors: DN15, [0.032 L/s.] [0.06 L/s.] <INSERT
OTHER>
26. Drain[s]: [38 mm grid strainer with] [38 mm removable, stainless-steel strainer
bucket with] [89 mm grid strainer with] [89 mm removable, stainless-steel crumb
cup with] [89 mm removable, chrome-plated, brass crumb cup with] [DN40 tubular-
brass tailpiece.] [DN40 tubular stainless-steel tailpiece.] <INSERT OTHER>
27. Plaster Sink Drain: Grid strainer with [DN40,] [DN50,] 1.1 mm thick, tubular-brass
tailpiece. <INSERT OTHER>
28. Plaster Sink Waste: [DN40,] [DN50,] 1.1 mm thick, tubular-brass tailpiece.
<INSERT OTHER>
29. Continuous Waste: [DN40,] [1.1 mm thick, tubular brass with slip-joint inlet.] [0.8
mm thick, tubular brass with slip-joint inlet.] [tubular plastic with slip-joint inlet.]
<INSERT OTHER>
30. Tubular Trap: [DN40,] [1.1 mm wall thickness, tubular brass,] [0.8 mm wall
thickness, tubular brass,] [plastic tubular fittings,] with slip-joint inlet [, cleanout,]
and wall flange.
31. Cast-Brass Trap: [DN40,] [DN40 by DN32,] cast-brass trap, with slip-joint inlet,
[cleanout,] [DN32,] [DN40,] pipe nipple to wall, and wall flange.

PLUMBING FIXTURES 15440 - Page 20/30


STD-SPC-DCA(A1)-ME-DCA REV A
<Project Title>

PROJECT STANDARD SPECIFICATION

32. Cast-Brass/Tubular Trap: [DN32,] [DN40 by DN32,] cast-brass trap, with slip-joint
inlet, {cleanout,} [DN32] [DN40] tubular brass, waste to wall, and wall flange.
33. Indirect Waste: [DN40,] [DN50,] [1.1 mm thick,] [0.8 mm thick,] [tubular brass.]
[plastic tubular fittings.] [pipe.] <INSERT OTHER>
34. Interceptor: [Cast iron with interior and exterior, acid-resistant-enamel coating,]
[Stainless-steel] [plaster] [sediment] interceptor designed for floor mounting. Include
[DN40,] [DN50,] inlet and outlet; removable, corrosion-resistant screens or bucket;
and [DN40,] [DN50,] waste piping with wall flange.
35. Food-Waste Disposer: Household, continuous feed. Include 115 VAC, 29-rev/s
motor with overload protection and reset button; wall switch; corrosion-resistant
chamber with jam-resistant grinder or shredder; DN40 outlet; quick-mounting,
stainless-steel sink flange; antisplash guard; and combination cover/stopper.
<INSERT OTHER DESCRIPTION; BATCH-FEED TYPE IS ALSO AVAILABLE>

a. Model: [1/3 hp,] [1/2 hp,] [3/4 hp,] model with cutlery- or stainless-steel
grinder or [shredder.] [shredder and sound-insulated chamber.] [shredder,
sound-insulated chamber, and stainless-steel outer shell.] <INSERT OTHER>

36. Hot-Water Dispenser: Household. Include instant ON-OFF control; insulated,


corrosion-resistant-metal storage tank that is open to atmosphere; electric, 115 VAC
heating element; chrome-plated faucet or spout; removable strainer; thermostat
control for water temperature up to 88 deg. C; and thermal overload protection.
<INSERT OTHER, FAUCET MODEL IS AVAILABLE>

a. Model: [1.26 L ] [1.9 L ] minimum tank capacity, [500 W] [750 W] [1300 W]


minimum input, with [gooseneck spout, and lever operator.] [twist-knob spout
assembly.] <INSERT OTHER>

37. Supply Insulation Kit: [Molded, soft-plastic covering for supplies from wall to
fixture with removable covering for stops and handles.] [Molded, soft-plastic
covering for hot-water supply from wall to fixture with removable covering for stop
and handle.] [Shaped, cushioned-jacket plastic covering with self-sticking fastening
system for supply stops and risers to fixture.] [Shaped, cushioned-jacket plastic
covering with self-sticking fastening system for hot-water supply stop and riser to
fixture.] Include manufacturer's standard fasteners, straps, and adhesives. <INSERT
COLOR IF REQUIRED>
38. Drain Insulation Kit: [Molded, soft-plastic covering for drain piping from fixture to
wall.] [Shaped, cushioned-jacket plastic covering with self-sticking fastening system
for drain piping and trap.] Include manufacturer's standard fasteners, straps, and
adhesives. <INSERT COLOR IF REQUIRED>
39. Fixture Support: [Type I, exposed arm;] [Type II, hanger plate;] [Type III,
combination, exposed arm and hanger plate;] [Type IV, support plate;] vertically
adjustable, sink, chair carrier with [steel-pipe] [heavy-duty, rectangular-steel,] upright
members; and feet. <INSERT OTHER>
40. Reinforcement: <INSERT SPECIFIC REQUIREMENTS, IF APPLICABLE>

0.17 SERVICE SINK SCHEDULE

A. Service Sink SS-[#]: Where plumbing fixtures of this designation are indicated, provide
products complying with the following:

1. Available Products: Subject to compliance with requirements, products that may be


incorporated into the Work include, but are not limited to, the following:
PLUMBING FIXTURES 15440 - Page 21/30
STD-SPC-DCA(A1)-ME-DCA REV A
<Project Title>

PROJECT STANDARD SPECIFICATION

2. Products: Subject to compliance with requirements, provide one of the following:


3. Enameled, Cast-Iron, Wall-Mounting Service Sink:

a. <INSERT PRODUCT NAME>

4. Enameled, Cast-Iron, Floor-Mounting Service Sink:

a. <INSERT PRODUCT NAME>

5. Stainless-Steel Service Sink:

a. <INSERT PRODUCT NAME>

6. Faucet:

a. <INSERT PRODUCT NAME>

7. Fixture Stainless-Steel Thickness: [2.0 mm .] <INSERT OTHER>


8. Fixture Dimensions: <INSERT SIZE>
9. Mounting: [Trap standard and wall bracket.] [Floor.] <INSERT OTHER>
10. Rim Guard: [Manufacturer's standard.] [Chrome plated, brass.] [Coated wire.]
<INSERT OTHER>
11. Faucet: Widespread, cast brass with supplies on 203 mm centers. <INSERT
OTHER>
12. Faucet Mounting: [Fixture back.] [Wall, centered on fixture.]
13. Faucet Components: Include the following:

a. Finish: [Rough chrome.] [Polished chrome.] [Rough brass.]


b. Handles: [Dual lever or 4 arm.] <INSERT OTHER>
c. Supply Stops: [Integral, in shanks.] <INSERT OTHER>
d. Spout: [With integral vacuum breaker, pail hook, and hose-thread outlet.]
<INSERT OTHER>
e. Wall Brace: [Assembly with wall bracket and support to faucet spout.
<INSERT OTHER>
f. Hose: 762 mm minimum, flexible hose with stainless-steel hose wall bracket.

14. Trap Standard: [DN80 ] [DN50 ] with grid strainer, enameled interior, cleanout, floor
support, and pipe waste to wall. <INSERT OTHER>
15. Drain: [DN80 ] [DN50 ] with grid strainer. <INSERT OTHER>
16. P-Trap: [DN80 ] [DN50 ] drainage piping.
17. Supplies: DN15 copper tubing{ with ball, gate, or globe valve}. <INSERT
OTHER>
18. Reinforcement: [Provide for wall-mounting faucet{ and wall brace}.] <INSERT
SPECIFIC REQUIREMENTS, IF APPLICABLE>

0.18 MOP-SERVICE BASIN SCHEDULE

A. Mop-Service Basin MS-[#]: Where plumbing fixtures of this designation are indicated,
provide products complying with the following:

1. Available Products: Subject to compliance with requirements, products that may be


incorporated into the Work include, but are not limited to, the following:
2. Products: Subject to compliance with requirements, provide one of the following:

PLUMBING FIXTURES 15440 - Page 22/30


STD-SPC-DCA(A1)-ME-DCA REV A
<Project Title>

PROJECT STANDARD SPECIFICATION

3. Terrazzo Mop-Service Basin:

a. <INSERT PRODUCT NAME>

4. Plastic Mop-Service Basin:

a. <INSERT PRODUCT NAME>

5. Stainless-Steel, Mop-Service Basin:

a. <INSERT PRODUCT NAME>

6. Faucet:

a. <INSERT PRODUCT NAME>

7. Fixture Stainless-Steel Thickness: [2.0 mm .] <INSERT OTHER>


8. Fixture Dimensions: [610 by 914 mm ] [610 by 610 mm ] [152 mm ] [305 mm ].
<INSERT OTHER>
9. Mounting: [Floor.] <INSERT OTHER>
10. Rim Guard: [Manufacturer's standard.] [Chrome plated, brass.] [Coated wire.]
<INSERT OTHER>
11. Faucet: Widespread, cast brass with supplies on 203 mm centers. <INSERT
OTHER>
12. Faucet Mounting: [Wall, centered on fixture.] <INSERT OTHER>
13. Faucet Components: Include the following:

a. Finish: [Rough chrome.] [Polished chrome.] [Rough brass.]


b. Handles: [Dual lever or 4 arm.] <INSERT OTHER>
c. Supply Stops: [Integral, in shanks.] <INSERT OTHER>
d. Spout: [With integral vacuum breaker, pail hook, and hose-thread outlet.]
<INSERT OTHER>
e. Wall Brace: [Assembly with wall bracket and support to faucet spout.
<INSERT OTHER>
f. Hose: 762 mm minimum, flexible hose with stainless-steel hose wall bracket.

14. Drain: [DN80 ] [DN50 ] with grid strainer. <INSERT OTHER>


15. P-Trap: [DN80 ] [DN50 ] drainage piping.
16. Mop Rack: <INSERT DESCRIPTION>
17. Supplies: DN15 copper tubing [with ball, gate, or globe valve]. <INSERT OTHER>
18. Reinforcement: Provide for wall-mounting faucet[ and wall brace.] [, wall brace, and
hose-hook bracket.] <INSERT SPECIFIC REQUIREMENTS, IF APPLICABLE>

0.19 LAUNDRY TRAY SCHEDULE

A. Laundry Tray LT-[#]: Where plumbing fixtures of this designation are indicated, provide
products complying with the following:

1. Available Products: Subject to compliance with requirements, products that may be


incorporated into the Work include, but are not limited to, the following:
2. Products: Subject to compliance with requirements, provide one of the following:
3. Enameled, Cast-Iron Laundry Tray:

PLUMBING FIXTURES 15440 - Page 23/30


STD-SPC-DCA(A1)-ME-DCA REV A
<Project Title>

PROJECT STANDARD SPECIFICATION

a. <INSERT PRODUCT NAME>

4. Plastic Laundry Trays:

a. <INSERT PRODUCT NAME>

5. Fixture Dimensions: <INSERT NO. OF COMPARTMENTS AND SIZES>


6. Fixture Mounting: [Wall hanging.] [Floor stand.] [Counter.]
7. Faucet Construction: [Cast brass.] <INSERT OTHER>
8. Faucet Mounting: [Centered on back of fixture.] [Centered on fixture deck.] [Wall,
centered on fixture.] [Counter, centered on fixture.]
9. Faucet Components: Include the following:

a. Spout: [Swing.] <INSERT OTHER>


b. Handles: [Dual lever or 4 arm.] <INSERT OTHER>
c. Soap Dish: [Integral, mounted on faucet.] <INSERT OTHER>

10. Supply Inlets: [DN15, brass pipe or copper tubing.] <INSERT OTHER>
11. Supply Stops: Manufacturer's standard brass, angle or straight, compression, [loose-
key type,] [wheel-handle type,] same size as supply inlet and with outlet matching
supply riser. <INSERT OTHER>
12. Supply Shutoff Valves: DN15 gate, globe, or ball.
13. Supply Risers: [DN10 flexible with knob end.] [DN10 rigid with DN8 straight,
knob-end tailpiece.] [DN10 rigid with DN8 offset, knob-end tailpiece.] [DN15
copper tubing.] <INSERT OTHER>
14. Drain{s}: Manufacturer's standard grid drain with DN40 tubular-brass tailpiece.
<INSERT OTHER>
15. Continuous Waste: [DN40,] [1.1 mm thick, tubular brass with slip-joint inlet.] [0.8
mm thick, tubular brass with slip-joint inlet.] [tubular plastic with slip-joint inlet.]
<INSERT OTHER>
16. Tubular Trap: [DN40,] [1.1 mm wall thickness, tubular brass,] [0.8 mm wall
thickness, tubular brass,] [plastic tubular fittings,] with slip-joint inlet [, cleanout,]
and wall flange.
17. Cast-Brass Trap: DN40, cast-brass trap, with slip-joint inlet, [cleanout,] DN40, pipe
nipple to wall, and wall flange.
18. Cast-Brass/Tubular Trap: DN40, cast-brass trap, with slip-joint inlet, [cleanout,]
DN40 tubular brass, waste to wall, and wall flange.
19. Fixture Support: [Type I, exposed arm;] [Type II, hanger plate;] [Type III,
combination, exposed arm and hanger plate;] vertically adjustable, sink, chair carrier
with steel-pipe upright members and feet.] [Manufacturer's standard steel stand or
base unit.] <INSERT OTHER>
20. Reinforcement: [Provide for wall-mounting faucet.] <INSERT SPECIFIC
REQUIREMENTS, IF APPLICABLE>

0.20 SHAMPOO BOWL SCHEDULE

A. Shampoo Bowl SB-[#]: Where plumbing fixtures of this designation are indicated, provide
products complying with the following:

1. Available Products: Subject to compliance with requirements, products that may be


incorporated into the Work include, but are not limited to, the following:
2. Products: Subject to compliance with requirements, provide one of the following:
3. Shampoo Bowl:
PLUMBING FIXTURES 15440 - Page 24/30
STD-SPC-DCA(A1)-ME-DCA REV A
<Project Title>

PROJECT STANDARD SPECIFICATION

a. <INSERT PRODUCT NAME>

4. Hair Interceptor:

a. <INSERT PRODUCT NAME>

5. Fixture Material: [Enameled, cast iron.] [Plastic.]


6. Fixture Dimensions: <INSERT SIZE>
7. Fixture Mounting: [Wall hanging.] [Counter mounting.]
8. Faucet: Manufacturer's standard cast-brass, center-set type with diverter, hose, and
spray. <INSERT OTHER>
9. Faucet Mounting: [Fixture deck.] <INSERT OTHER>
10. Supply Inlets: [DN10,] [DN15,] brass pipe or copper tubing.
11. Supply Stops: Manufacturer's standard brass, angle or straight, compression, [loose-
key type,] [wheel-handle type,] same size as supply inlet and with outlet matching
supply riser. <INSERT OTHER>
12. Supply Risers: [DN10 flexible with knob end.] [DN10 rigid with DN8 straight,
knob-end tailpiece.] [DN10 rigid with DN8 offset, knob-end tailpiece.] <INSERT
OTHER>
13. Drain: [Manufacturer's standard grid drain with DN40 tailpiece.] <INSERT
OTHER>
14. Tubular Trap: [DN40,] [1.1 mm wall thickness, tubular brass,] [0.8 mm wall
thickness, tubular brass,] [plastic tubular fittings,] with slip-joint inlet{, cleanout,}
and wall flange.
15. Cast-Brass Trap: DN40, cast-brass trap, with slip-joint inlet, [cleanout,] DN40, pipe
nipple to wall, and wall flange.
16. Cast-Brass/Tubular Trap: DN40, cast-brass trap, with slip-joint inlet, {cleanout,}
DN40 [1.1 mm,] [0.8 mm,] wall thickness, tubular brass, waste to wall, and wall
flange.
17. Hair-Interceptor Trap: Chrome-plated, brass [or stainless-steel] housing with
removable brass or stainless-steel screen or bucket; DN40 slip-joint inlet; DN40
outlet; DN40 pipe nipple to wall; and wall flange.
18. Fixture Support: [Vertically adjustable, lavatory or sink, chair carrier with support
plate or device matching fixture mounting; steel-pipe upright members; and feet.]
<INSERT OTHER>
19. Reinforcement: <INSERT SPECIFIC REQUIREMENTS, IF APPLICABLE>

0.21 DRINKING FOUNTAIN SCHEDULE

A. [Accessible ]Drinking Fountain DF-[#]: Where plumbing fixtures of this designation are
indicated, provide products complying with the following:

1. Available Products: Subject to compliance with requirements, products that may be


incorporated into the Work include, but are not limited to, the following:
2. Products: Subject to compliance with requirements, provide one of the following:
3. Vitreous-China Drinking Fountain:

a. <INSERT PRODUCT NAME>

4. Stainless-Steel Drinking Fountain:

a. <INSERT PRODUCT NAME>

PLUMBING FIXTURES 15440 - Page 25/30


STD-SPC-DCA(A1)-ME-DCA REV A
<Project Title>

PROJECT STANDARD SPECIFICATION

5. Miscellaneous-Material Drinking Fountain:

a. <INSERT PRODUCT NAME>

6. Miscellaneous Fixture Material: [Plastic.] [Enameled steel.] [Masonry.] [Concrete.]


<INSERT OTHER>
7. Fixture Color: <INSERT COLOR>
8. Fixture Mounting: [Wall hanging.] [Pedestal.] <INSERT OTHER>
9. Supply: [DN10] [DN15] copper tubing with gate, globe, or ball valve.
10. Cast-Brass Trap: [DN32,] [DN40 by DN32,] cast-brass trap, with slip-joint inlet,
{cleanout,} [DN32,] [DN40,] pipe nipple to wall, and wall flange.
11. P-Trap: [DN50 drainage piping with DN40 riser to fixture drain.] <INSERT
OTHER>
12. Supply Insulation Kit: [Molded, soft-plastic covering for supply from wall to fixture
with removable covering for stop and handle.] [Shaped, cushioned-jacket plastic
covering with self-sticking fastening system for supply stop and riser to fixture.]
Include manufacturer's standard fasteners, straps, and adhesives. <INSERT COLOR
IF REQUIRED>
13. Drain Insulation Kit: [Molded, soft-plastic covering for drain piping from fixture to
wall.] [Shaped, cushioned-jacket plastic covering with self-sticking fastening system
for drain piping and trap.] Include manufacturer's standard fasteners, straps, and
adhesives. <INSERT COLOR IF REQUIRED>
14. Fixture Support: Type I, vertically adjustable, hanger-plate, water-cooler, chair
carrier with [steel-pipe] [heavy-duty, rectangular-steel,] upright members, bearing
plate, and feet. <INSERT OTHER>
15. Reinforcement: <INSERT SPECIFIC REQUIREMENTS, IF APPLICABLE>

0.22 ELECTRIC WATER COOLER SCHEDULE

A. [Accessible ]Electric Water Cooler EWC-[#]: Where plumbing fixtures of this designation
are indicated, provide products complying with the following:

1. Available Products: Subject to compliance with requirements, products that may be


incorporated into the Work include, but are not limited to, the following:
2. Products: Subject to compliance with requirements, provide one of the following:

a. <INSERT PRODUCT NAME>

3. Fixture Type: [Bubbler.] [Bilevel bubbler.] [Bubbler with hot-water faucet.] [Bottle.]
[Bubbler with remote chiller.] <INSERT OTHER>
4. No. of Bubblers or Stations: [One.] [2.] [3.] <INSERT OTHER>
5. Fixture Unit Capacity: <INSERT CAPACITY CHILLED WATER>
6. Fixture Cabinet Material: [Stainless steel.] [Enameled steel.] [Vinyl-covered steel.]
<INSERT OTHER>
7. Fixture Color or Finish: <INSERT COLOR OR FINISH>
8. Fixture Mounting: [Wall.] [Free standing.] [Semirecessed.] [Recessed.] <INSERT
OTHER>
9. Wall Grille: [Stainless steel.] [Enameled steel.] <INSERT SIZE>
10. Supply: DN10 copper tubing with gate, globe, or ball valve. <INSERT OTHER>
11. Water Filter: [Manufacturer's standard.] [Cartridge type for 254 mm cartridge with
stainless-steel or plastic housing, fittings, and mounting bracket. Include replaceable,
activated-carbon, wound-fiber, or pleated cartridge with 10-micron removal rating.]

PLUMBING FIXTURES 15440 - Page 26/30


STD-SPC-DCA(A1)-ME-DCA REV A
<Project Title>

PROJECT STANDARD SPECIFICATION

12. Cast-Brass Trap{s}: [DN32,] [DN40 by DN32,] cast-brass trap, with slip-joint inlet,
[cleanout,] [DN32,] [DN40,] pipe nipple to wall, and wall flange.
13. Supply Insulation Kit{s}: [Molded, soft-plastic covering for supply from wall to
fixture with removable covering for stop and handle.] [Shaped, cushioned-jacket
plastic covering with self-sticking fastening system for supply stop and riser to
fixture.] Include manufacturer's standard fasteners, straps, and adhesives. <INSERT
COLOR IF REQUIRED>
14. Drain Insulation Kit[s]: [Molded, soft-plastic covering for drain piping from fixture
to wall.] [Shaped, cushioned-jacket plastic covering with self-sticking fastening
system for drain piping and trap.] Include manufacturer's standard fasteners, straps,
and adhesives. <INSERT COLOR IF REQUIRED>
15. Fixture Support: [Type I,] [Type II, bilevel,] vertically adjustable, hanger-plate,
water-cooler, chair carrier with [steel-pipe] [heavy-duty, rectangular-steel,] upright
members, bearing plate[s], and feet. <INSERT OTHER>
16. Reinforcement: [Fabricate to enclose mounting box.] <INSERT SPECIFIC
REQUIREMENTS, IF APPLICABLE>

B. Wheelchair Electric similar to Water Cooler EWC[ ]) except cooler is provided with 686
mm minimum knee clearance from front bottom of unit to floor and 914 mm maximum
spout height above floor. Bubblers shall also be controlled by push levers, by push bars, or
touch pads one on each side or one on front and both sides of the cabinet

0.23 EMERGENCY EQUIPMENT SCHEDULE

A. [{Accessible }Emergency Eyewash EW-[#]:] [{Accessible }Emergency Shower ES-[#]:]


Where plumbing fixtures of this designation are indicated, provide products complying with
the following:

1. Available Products: Subject to compliance with requirements, products that may be


incorporated into the Work include, but are not limited to, the following:
2. Products: Subject to compliance with requirements, provide one of the following:

a. <INSERT PRODUCT NAME>

3. Material: <INSERT MATERIALS OR COATINGS OF MAJOR COMPONENTS>


4. Mounting: [Wall.] [Counter.] [Floor, with wall brace.] <INSERT OTHER>
5. Supply: [DN15] [DN25] [DN40] copper tubing. <INSERT OTHER>
6. Drain: <INSERT DESCRIPTION IF REQUIRED>
7. Trap: <INSERT DESCRIPTION IF REQUIRED>
8. Reinforcement: <INSERT SPECIFIC REQUIREMENTS, IF APPLICABLE>

0.24 EMPLOYER-FURNISHED [FIXTURE] [EQUIPMENT] SCHEDULE

A. [Accessible ]Employer-Furnished [Fixture] [Equipment] [#]: Where plumbing fixtures of


this designation are indicated, retain fixture in-place or relocate and reinstall as indicated,
and provide products complying with the following:

1. Available Products: Subject to compliance with requirements, products that may be


incorporated into the Work include, but are not limited to, the following:
2. Products: Subject to compliance with requirements, provide one of the following:
3. Flushometer Valve:

PLUMBING FIXTURES 15440 - Page 27/30


STD-SPC-DCA(A1)-ME-DCA REV A
<Project Title>

PROJECT STANDARD SPECIFICATION

a. <INSERT PRODUCT NAME>

4. Toilet Seat:

a. <INSERT PRODUCT NAME>

5. Faucet:

a. <INSERT PRODUCT NAME>

6. Laminar-Flow, Faucet-Spout Fitting:

a. <INSERT PRODUCT NAME>

7. Fitting Insulation Kit:

8. Flushometer Valve Construction: Cast-brass body, brass or copper pipe or tubing


inlet with wall flange and tailpiece with spud, screwdriver check stop, and vacuum
breaker.
9. Flushometer Valve Operation: [Diaphragm.] <INSERT OTHER>
10. Flushometer Valve Finish: [Rough brass.] [Polished, chrome-plated, exposed metal
parts.]
11. Flushometer Valve, Water Consumption: Factory set or field adjusted, 6 L
maximum per flushing cycle.
12. Flushometer valve components include the following:

a. Brass, lever-handle actuation.


b. Bacteria-control-coated, brass, lever-handle actuation.
c. Nonhold-open feature.
d. Wheel-handle stop.
e. Metal, push-button actuation.
f. Seat bumper on stop.
g. Hydraulic, push-button-actuation, flushing system.
h. Bedpan washer with diverter valve, spray head, and support.
i. Battery-powered, sensor-actuation, automatic flushing system.
j. Electric, hard-wired, sensor-actuation, automatic flushing system.
k. Tailpiece, trap-primer connection.

13. Supply Inlet: [DN15] [DN10] with wall flange.


14. Supply Stop: [Loose key.] [Wheel handle.] <INSERT OTHER>
15. Supply Riser: [DN15,] [DN10,] [flexible riser with collar end.] [rigid riser with
collar end.]
16. Toilet Seat: Solid-plastic, water-closet seat with bumpers and hardware, compatible
with water closet and as follows:

a. Color: [White.] [Black.] [Matching water closet.] <INSERT OTHER>


b. Class: [Commercial, Heavy Duty.] [Commercial, Standard.] [Residential.]
[Commercial, Extra-Heavy-Duty type, exceeding requirements of Commercial,
Standard class.]
c. Size: [Elongated.] [Round front.]
d. Pattern: [Open front without cover.] [Open front with cover.] [Closed front
with cover.]
e. Hinge Type: [Check (CK).] [Noncheck (NC).] [Self-sustaining check (SC).]
[Self-raising (SR).]

PLUMBING FIXTURES 15440 - Page 28/30


STD-SPC-DCA(A1)-ME-DCA REV A
<Project Title>

PROJECT STANDARD SPECIFICATION

17. Faucet Construction: [Center set with inlets on 102 mm centers,] [Center set with
central inlets,] [Widespread with inlets on 203 mm centers,] [Single-inlet,] [cast
brass,] [cast-brass underbody and brass escutcheon,] [nonmetal (plastic) underbody
and plastic or brass escutcheon,] [and with pop-up waste.] [and without pop-up
waste.] <INSERT OTHER>
18. Faucet Valve Operation: [Manual, ON-OFF.] [Manual, adjustable, self-closing,
metering.] [Electric, hard wired, sensor actuation, automatic.] <INSERT OTHER>
19. Faucet Mounting Position: [Centered on fixture deck.] [Counter, centered on fixture.]
[Centered on fixture backsplash.]
20. Faucet Components: Include the following:

a. Accessible-Fixture Operation: [Manual.] [Sensor actuation.] <INSERT


OTHER>
b. Handle{s}: [Dual lever.] [Dual, 3 or 4 arms.] [Dual, metal knobs.] [Dual,
crystal knobs.] [Dual, metering, self-closing, push buttons.] [Single-lever
toggle.] [Extended, single-lever toggle.] [Single, push-pull and twist.] [Dual,
102 mm wrist blade.] [Dual, 152 mm wrist blade.] <INSERT OTHER>
c. Spout: [Integral with body.] [Swing gooseneck.] [Fixed-position gooseneck.]
d. Spout Length, Centerline of Inlets to Outlet: <INSERT IF OTHER THAN
MFR'S STANDARD>
e. Gooseneck Height and Offset, Centerline of Inlets to Outlet: <INSERT IF
OTHER THAN MFR'S STANDARD>
f. Spout Outlet: [Manufacturer's standard aerator.] [0.032 L/s laminar flow.]
[0.047-L/s laminar flow.] <INSERT OTHER>
g. Spout-Outlet, Flow-Control Fitting: [0.032 L/s.] [0.047 L/s.] <INSERT
OTHER>

21. Supply Inlets: [DN10,] [DN15,] brass pipe or copper tubing.


22. Supply Stops: Manufacturer's standard brass, angle or straight, compression, [loose-
key type,] [wheel-handle type,] same size as supply inlet and with outlet matching
supply riser. <INSERT OTHER>
23. Supply Risers: [DN10 flexible with knob end.] [DN10 rigid with DN8 straight,
knob-end tailpiece.] [DN10 rigid with DN8 offset, knob-end tailpiece.] <INSERT
OTHER>
24. Supply, Flow-Control Restrictors: [DN10,] [DN15,] 0.032 L/s. <INSERT OTHER>
25. Drain: [Grid strainer with DN32 tailpiece.] [Grid strainer with DN32 offset waste.]
[Pop-up with DN32 tailpiece, included with faucet.] [Open with rubber stopper and
chain.] <INSERT OTHER>
26. Tubular Trap: [DN32,] [DN40 by DN32,] [DN40,] [1.1 mm wall thickness, tubular
brass,] [0.8 mm wall thickness, tubular brass,] [plastic tubular fittings,] with slip-joint
inlet, cleanout, and wall flange.
27. Cast-Brass Trap: [DN32,] [DN40 by DN32,] [DN40,] cast-brass trap, with slip-joint
inlet[, cleanout,] [DN32,] [DN40,] pipe nipple to wall, and wall flange.
28. Cast-Brass/Tubular Trap: [DN32,] [DN40 by DN32,] [DN40,] cast-brass trap, with
slip-joint inlet[, cleanout,] [DN32] [DN40] tubular brass, waste to wall, and wall
flange.
29. Hair-Interceptor Trap: Chrome-plated, brass [or stainless-steel] housing with
removable brass or stainless-steel screen or bucket; [DN32] [DN40] inlet and outlet,
pipe nipples to sink drain and wall; and wall flange.
30. Supply Insulation Kit: [Molded, soft-plastic covering for supplies from wall to
fixture with removable covering for stops and handles.] [Molded, soft-plastic
covering for hot-water supply from wall to fixture with removable covering for stop
and handle.] [Shaped, cushioned-jacket plastic covering with self-sticking fastening

PLUMBING FIXTURES 15440 - Page 29/30


STD-SPC-DCA(A1)-ME-DCA REV A
<Project Title>

PROJECT STANDARD SPECIFICATION

system for supply stops and risers to fixture.] [Shaped, cushioned-jacket plastic
covering with self-sticking fastening system for hot-water supply stop and riser to
fixture.] Include manufacturer's standard fasteners, straps, and adhesives. <INSERT
COLOR IF REQUIRED>
31. Drain Insulation Kit: [Molded, soft-plastic covering for drain piping from fixture to
wall.] [Shaped, cushioned-jacket plastic covering with self-sticking fastening system
for drain piping and trap.] Include manufacturer's standard fasteners, straps, and
adhesives. <INSERT COLOR IF REQUIRED>
32. Fixture Support: Vertically adjustable, cast-iron, [elevated-type,] water-closet carrier
with combination support and waste fitting assemblies and tiling frame or setting
gage. Include additional faceplate and coupling for water closet at wide pipe space.
Compact-type carrier for back-to-back water-closet installation is prohibited.
33. Fixture Support: [Vertically adjustable, chair carrier with support plate or device
matching fixture mounting; steel-pipe upright members; and feet.] <INSERT
OTHER>
34. Reinforcement: <INSERT SPECIFIC REQUIREMENTS, IF APPLICABLE>

END OF SECTION 15440

PLUMBING FIXTURES 15440 - Page 30/30