Answer All The Questions. Each Carries One Mark. 1

1. The document is a weekly test for an Electrical Engineering course containing 10 multiple choice questions about electrical technology topics like transformers, DC machines, and autotransformers. 2. The questions cover calculations of transformer ratings, electromagnetic torque in DC machines, principles of DC generators, components of DC generators, armature windings, autotransformer ratios, and power transfer methods in autotransformers. 3. The test is out of a total of 10 marks and requires students to choose the correct answer for each question.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
69 views3 pages

Answer All The Questions. Each Carries One Mark. 1

1. The document is a weekly test for an Electrical Engineering course containing 10 multiple choice questions about electrical technology topics like transformers, DC machines, and autotransformers. 2. The questions cover calculations of transformer ratings, electromagnetic torque in DC machines, principles of DC generators, components of DC generators, armature windings, autotransformer ratios, and power transfer methods in autotransformers. 3. The test is out of a total of 10 marks and requires students to choose the correct answer for each question.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Rajiv Gandhi University of Knowledge Technologies

Department of Electrical Engineering

Weekly Test -9

Date: 01-11-2014 Subject: Electrical technology Time: 30mins.

Course: EE1101 Max Marks: 10

Answer all the Questions. Each carries one mark.

1. A 1.5 kVA, 500 V/200 V two winding transformer is re-connected similar to an auto-
transformer as shown in Fig. 1. The rating of the auto-transformer thus formed is

Fig. 1
A. 15 kVA

B. 7.5 kVA

C. 6.5 kVA

D. 5.25 kVA

2. A 6 pole DC machine has a lap wound armature with 240 conductors. If the flux per pole is 0.25
mWb, speed of rotation is 500 rpm and the armature current is 90A, then the electro-magnetic
torque developed in the machine is

A. 0.14 Nm

B. 0.43 Nm

C. 0.5 Nm

D. 0.86 Nm
3. The DC Generator works on the application principle of

A. Fleming's Right Hand Rule

B. Fleming's Left Hand Rule

C. Thumb Rule

D. Amperes law

4. A commutator in a DC Generator can convert

a) ac to dc
b) dc to ac
c) Both (a) and (b)
d) None of these

5. A P- pole lap wound dc machine had an armature current Ia . The conductor current in the
armature winding is
a) Ia
b) Ia /P
c) Ia /2
d) P Ia

6. The number of parallel paths for a 4- pole wave winding will be


a) 4
b) 8
c) 2
d) 6

7. An autotransformer having a transformation ratio ( N2/N1) of 0.8 supplies a load of 3 KW. The
power transferred conductively from primary to secondary is
a) 0.6 KW
b) 2.4 KW
c) 1.5 KW
d) 0.27 KW

8. For same KVA rating, an auto transformer has …………… as compared to a conventional 2-
winding transformer
a) Higher efficiency
b) Lower core loss and voltage regulation
c) Smaller size
d) All of the above
9. A 4 pole DC machine has a wave wound armature with 300 conductors. If the flux per pole is
0.01Wb and it is driven at a speed of 1000 rev/min, then the Emf generated in the DC machine
is

a) 250 V
b) 150 V
c) 100 V
d) 200 V

10. In an Auto – Transformer, power is transferred from primary to secondary


a) Inductively
b) Conductively
c) Both (a) and (b)
d) Either (a) or (b)